HomeMy WebLinkAboutWQ0031317_Compliance Evaluation Inspection_20220318DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
Karen Williams
Global Nuclear Fuel - Americas LLC
PO Box 780
Wilmington, NC 28402-0780
NORTH CAROLINA
Environmental Quality
March 28, 2022
SUBJECT: Compliance Inspection Report
GNF-A Wilmington -Castle Hayne WWTP
Non -discharge Permit No. WQ0031317
New Hanover County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the GNF-A Wilmington -Castle
Hayne WWTP on 3/18/2022. This inspection was conducted to verify that the facility is operating in
compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0031317. The
findings and comments noted during this inspection are provided in the enclosed copy of the inspection
report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
ATTACHMENTS
Cc: Upload to Laser fiche
Sincerely,
E-T
DocuSigned by:
oµ 'T�n�l. �cOA, for
7F141E73B6F3456...
Morella Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
DE Q��North Carolina Department of Environmental Quality I Division of Water Resources
Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington. North Carolina 28405
.�� /`� 910.796.7215
DocuSign Envelope ID: 3BF32E40-AA5E-40A5-AB29-74COF65F6862
Compliance Inspection Report
Permit: WQ0031317 Effective: 03/01/18 Expiration: 02/28/23 Owner: Global Nuclear Fuel - Americas LLC
SOC: Effective: Expiration: Facility: GNF-A Wilmington -Castle Hayne WWTP
County: New Hanover 3901 Castle Hayne Rd
Region: Wilmington NC Hwy 133
Wilmington NC 28402
Contact Person: David Anderson Title: Facilities Manager Phone: 843-735-9086
Directions to Facility:
Take US-117N/N College Rd to 1-40W, Continue on 1-40. Take exit 17 from 1-1 40W/US-1 7S, turn R onto NC-133N/Castle Hayne
Road
System Classifications: WW2,
Primary ORC: Michael Wayne Phipps Certification: 986536 Phone: 910-675-6029
Secondary ORC(s):
On -Site Representative(s):
On -site representative
Related Permits:
Karen Williams
910-547-2758
NC0001228 Global Nuclear Fuel - Americas LLC - GNF-A Wilmington -Castle Hayne
WWTP
Inspection Date: 03/18/2022 Entry Time 08:30AM Exit Time: 09:30AM
Primary Inspector: Helen I Perez Docusignetd�by: Phone: 910-796-7387
Secondary Inspector(s): � r�
1 D645B4A39694BE_
Docusigned by: 3/28/2022
Reason for Inspection: Routine E7011,11E73B6F3456_
T°A, Inspection Type: Compliance Evaluation
Permit Inspection Type: Reclaimed Water
Facility Status: 0 Compliant ❑ Not Compliant
Question Areas:
Treatment Flow Measurement -Effluent
Treatment Flow Measurement -Water
Use Records
Treatment Filters
Treatment Sludge Storage/Treatment
Treatment Return pumps
(See attachment summary)
Treatment Flow Measurement -Influent Miscellaneous Questions
Treatment Treatment Barscreen
Record Keeping
Treatment Disinfection
End Use -Reuse
Treatment Activated Sludge
Treatment Flow Measurement
Standby Power
Page 1 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
A routine compliance inspection of the Global Nuclear Fuel -Americas (GNF-A) WWTF was conducted on March 18, 2022.
The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations
specified in Non -Discharge Permit WQ0031317. Karen Williams, Sr Fixed Facilities Specialist, and operating staff were
present during the inspection, along with Doug Dowden and Amir Adaryani from the DWR Central Office for renewal review.
This 75,000 GPD facility treats the domestic wastewater from the industrial site through a Membrane Bioreactor (MBR)
system to reclaim standards for the conjuctive use of site cooling towers. The effluent can be discharged to Outfall 002 of
NPDES Permit NC0001228 if the demand for conjuctive reclaim use decreases or reclaim standards are not met. This outfall
discharges to the Northeast Cape Fear River. Currently, the plant treats approximately 15,000-16,000 gpd.
All reclaimed water piping, valves, storage tanks and outlets are labeled and color -coded purple as required. A detailed
placard of reclaim information and use is posted at the treatment plant and reclaim use sites for notification to employees.
A review of files since last inspection in February 2020 shows a daily TSS limit exceedance in July 2021 and a daily
ammonia exceedance in February 2022. Flow did not get discharged to the outfall in either event. The permit expires on
February 28, 2023. A renewal application submittal will be required no later that six months prior to expiration.
The GNF-A facility is compliant with the Non -Discharge Permit W00031317. Please review the comment sections of the
inspection report for more details.
Page 2 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-40A5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Type
Reuse (Quality)
Infiltration System
Lagoon Spray, LR
Single Family Spray, LR
Activated Sludge Spray, LR
Activated Sludge Spray, HR
Activated Sludge Drip, LR
Single Family Drip
Recycle/Reuse
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Comment: No comment.
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment: The effluent flowmeter was calibrated on 06/29/2021
Standby Power
Is automatically activated standby power available?
Carotek.
Yes No NA NE
■❑❑❑
■❑❑❑
Yes No NA NE
❑❑■❑
❑ ❑ ❑
❑ ❑ ❑
Yes No NA NE
Yes No NA NE
■❑❑❑
❑❑❑■
■❑❑❑
■❑❑❑
■❑❑❑
Yes No NA NE
❑❑■❑
Page 3 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment: The facility has access to dual power sources, the Sutton Plant and the Castle Havne feed
and power can be switched when one fails. A hook-up for a portable generator and a transfer
switch is also available if needed.
Treatment Barscreen Yes No NA NE
Is it free of excessive debris? 0 ❑ ❑ ❑
Is disposal of screenings in compliance? 0 ❑ ❑ ❑
Are the bars spaced properly? ❑ ❑ 0 ❑
Is the unit in good condition? 0 ❑ ❑ ❑
Comment: Influent flows throuqh a mechanical screw screen followed by a 2 mm fine screen.
Treatment Activated Sludge Yes No NA NE
Is the aeration mechanism operable? 0 ❑ ❑ ❑
Is the aeration basin thoroughly mixed? ❑ ❑ ❑
Is the aeration equipment easily accessed? ❑ ❑ ❑
Is Dissolved Oxygen adequate? ❑ ❑ ❑
Are Settleometer results acceptable? ❑ ❑ ❑
Is activated sludge an acceptable color? 0 ❑ ❑ ❑
Comment: From the 2 EQ tanks, wastewater flows through 2 anoxic tanks with nitrate recycle return,
followed by 4 aeration basins with fine bubble diffusers. Each aeration basin has DO
monitoring. DO was recorded at 2.96 mg/I in the third aeration basin. Mix liquor is typically
9500-10,000 mg/I.
Treatment Return pumps Yes No NA NE
Are they in place? 0 ❑ ❑ ❑
Are they operational? 0 ❑ ❑ ❑
Comment: No comment.
Treatment Filters
Is the filter media present?
Is the filter media the correct size and type?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids?
Is the mud well free of excessive solids and filter media?
Does backwashing frequency appear adequate?
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑❑■❑
❑❑■❑
❑❑■❑
Page 4 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Comment: The facility has 2 Membrane Bioreactor (MBR) units, each with 2 chambers consisting of 2
cassettes with 8 filtration modules per cassette. The 70,000 gallon units alternate after a set
amount of filter/back pulse cycles. The MBR unis are cleaned annually with a chlorine and citric
acid cleaning system.
Treatment Sludge Storage/Treatment Yes No NA NE
Is the aeration operational? 0 ❑ ❑ ❑
Is the aeration pattern even? ❑ ❑ ❑
If required, are Sanitary "Ts" present in tankage? ❑ ❑ ❑ ❑
Comment: Waste activated sludge is pumped to a series of 6 digesters. Solids from the digesters are
treated, approximately once a week, with lime before and after it is processed through a filter
press. Solids are then transfered to a covered storage area for further drying, bagged and
sent to Envirocare Waste Disposal in Utah.
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (-30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
❑❑■❑
■❑❑❑
❑❑■❑
❑❑■❑
❑❑■❑
❑❑■❑
❑❑■❑
❑❑■❑
■❑❑❑
❑❑❑■
❑❑■❑
❑❑■❑
❑❑■❑
Comment: Disinfection consists of 2 UV units with 4 lamps each. Effluent is stored in a 20,000 qallon tank
with a liquid chlorine infection pump to provide chlorine residual in the reclaimed utilization
system.
Record Keeping Yes No NA NE
Is a copy of current permit available? ❑ ❑ ❑
Are monitoring reports present: NDMR? ❑ ❑ ❑
NDAR? ❑ ❑ ❑
Are flow rates less than of permitted flow? ❑ ❑ ❑
Page 5 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Are flow rates less than of permitted flow?
0
❑ ❑ ❑
Are application rates adhered to?
❑
❑ 0 ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
❑
❑ 0 ❑
Are all samples analyzed for all required parameters?
❑
❑ 0 ❑
Are there any 2L GW quality violations?
❑
❑ 0 ❑
Is GW-59A certification form completed for facility?
❑
❑ 0 ❑
Is effluent sampled for same parameters as GW?
❑
❑ 0 ❑
Do effluent concentrations exceed GW standards?
❑
❑ 0 ❑
Are annual soil reports available?
❑
❑ 0 ❑
# Are PAN records required?
❑
❑ 0 ❑
# Did last soil report indicate a need for lime?
❑
❑ 0 ❑
If so, has it been applied?
❑
❑ 0 ❑
Are operational logs present?
0
❑ ❑ ❑
Are lab sheets available for review?
0
❑ ❑ ❑
Do lab sheets support data reported on NDMR?
❑
❑ ❑
Do lab sheets support data reported on GW-59s?
❑
❑ 0 ❑
Are Operational and Maintenance records present?
0
❑ ❑ ❑
Were Operational and Maintenance records complete?
0
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
0
❑ ❑ ❑
Is a copy of the SOC readily available?
❑
❑ 0 ❑
No treatment units bypassed since last inspection? 0 ❑ ❑ ❑
Comment: A daily check list is used by staff to document operations of the plant and a work order system
is used for maintenance. Calibrations records and bench sheets for field parameters were
complete and analyzed under the Field Certification # 166. Field instrumentation was calibrated
and verified by Envirochem on 2/3/2022. All other required parameters are analyzed by
Envirochem, Certification #94.
End Use -Reuse
Is the acreage in the permit being utilized?
Does the acreage specified in the permit correspond to the measured acreage at the site?
Are all essential units provided in duplicate?
Is an automatically activated standby power source available?
Is the equalization capacity adequate?
Is aerated flow equalization present?
Has the turbidity meter been calibrated in the last 12 months?
Does the turbidity meter have recording capabilities?
Is all flow diverted at the appropriate times?
Is all upset wastewater diverted from reuse storage unit?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
■❑❑❑
■❑❑❑
■❑❑❑
■❑❑❑
■❑❑❑
■❑❑❑
Page 6 of 7
DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862
Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC
Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Is all upset wastewater treated, retreated, or disposed of acceptably?
0
❑ ❑ ❑
Is upset wastewater treated prior to discharge to irrigation storage?
❑
❑ 0 ❑
Is public access restricted from irrigation area during active site use?
❑
❑ 0 ❑
If golf course, is a sign posted in plain sight on the club house?
❑
❑ 0 ❑
Is the cover crop acceptable?
❑
❑ 0 ❑
Are buffers adequate?
❑
❑ 0 ❑
Is the site free of ponding/runoff?
❑
❑ 0 ❑
Is the acreage in the permit being utilized?
❑
❑ 0 ❑
Is the application equipment acceptable?
❑
❑ 0 ❑
Is the application area free of limiting slopes?
❑
❑ 0 ❑
How close is the closest water supply well?
❑
❑ 0 ❑
Are any supply wells within the CB?
❑
❑ 0 ❑
Are any supply wells within 250' of the CB?
❑
❑ 0 ❑
Is municipal water available in the area?
❑
❑ 0 ❑
Are GW monitoring wells required?
❑
❑ 0 ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
❑
❑ 0 ❑
Are GW monitoring wells properly constructed, including screened interval?
❑
❑ 0 ❑
Comment: The turbidity meter was calibrated on 03/17/2022 and is calibrated on a
quarterly schedule by
facility maintenance staff. Reclaimed effluent is stored in the 20,000 gallon tank and used for
facility cooling towers. The flow can be discharged to Outfall 002 of NPDES Permit NC0001228
if the demand for coniuctive reclaim use decreases or reclaim standards are not met. This
outfall discharges to the Northeast Cape Fear River.
Page 7 of 7