HomeMy WebLinkAboutWQ0031317_Compliance Evaluation Inspection_20220318DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Karen Williams Global Nuclear Fuel - Americas LLC PO Box 780 Wilmington, NC 28402-0780 NORTH CAROLINA Environmental Quality March 28, 2022 SUBJECT: Compliance Inspection Report GNF-A Wilmington -Castle Hayne WWTP Non -discharge Permit No. WQ0031317 New Hanover County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the GNF-A Wilmington -Castle Hayne WWTP on 3/18/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0031317. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. ATTACHMENTS Cc: Upload to Laser fiche Sincerely, E-T DocuSigned by: oµ 'T�n�l. �cOA, for 7F141E73B6F3456... Morella Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ DE Q��North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington. North Carolina 28405 .�� /`� 910.796.7215 DocuSign Envelope ID: 3BF32E40-AA5E-40A5-AB29-74COF65F6862 Compliance Inspection Report Permit: WQ0031317 Effective: 03/01/18 Expiration: 02/28/23 Owner: Global Nuclear Fuel - Americas LLC SOC: Effective: Expiration: Facility: GNF-A Wilmington -Castle Hayne WWTP County: New Hanover 3901 Castle Hayne Rd Region: Wilmington NC Hwy 133 Wilmington NC 28402 Contact Person: David Anderson Title: Facilities Manager Phone: 843-735-9086 Directions to Facility: Take US-117N/N College Rd to 1-40W, Continue on 1-40. Take exit 17 from 1-1 40W/US-1 7S, turn R onto NC-133N/Castle Hayne Road System Classifications: WW2, Primary ORC: Michael Wayne Phipps Certification: 986536 Phone: 910-675-6029 Secondary ORC(s): On -Site Representative(s): On -site representative Related Permits: Karen Williams 910-547-2758 NC0001228 Global Nuclear Fuel - Americas LLC - GNF-A Wilmington -Castle Hayne WWTP Inspection Date: 03/18/2022 Entry Time 08:30AM Exit Time: 09:30AM Primary Inspector: Helen I Perez Docusignetd�by: Phone: 910-796-7387 Secondary Inspector(s): � r� 1 D645B4A39694BE_ Docusigned by: 3/28/2022 Reason for Inspection: Routine E7011,11E73B6F3456_ T°A, Inspection Type: Compliance Evaluation Permit Inspection Type: Reclaimed Water Facility Status: 0 Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Water Use Records Treatment Filters Treatment Sludge Storage/Treatment Treatment Return pumps (See attachment summary) Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Treatment Barscreen Record Keeping Treatment Disinfection End Use -Reuse Treatment Activated Sludge Treatment Flow Measurement Standby Power Page 1 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Global Nuclear Fuel -Americas (GNF-A) WWTF was conducted on March 18, 2022. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Non -Discharge Permit WQ0031317. Karen Williams, Sr Fixed Facilities Specialist, and operating staff were present during the inspection, along with Doug Dowden and Amir Adaryani from the DWR Central Office for renewal review. This 75,000 GPD facility treats the domestic wastewater from the industrial site through a Membrane Bioreactor (MBR) system to reclaim standards for the conjuctive use of site cooling towers. The effluent can be discharged to Outfall 002 of NPDES Permit NC0001228 if the demand for conjuctive reclaim use decreases or reclaim standards are not met. This outfall discharges to the Northeast Cape Fear River. Currently, the plant treats approximately 15,000-16,000 gpd. All reclaimed water piping, valves, storage tanks and outlets are labeled and color -coded purple as required. A detailed placard of reclaim information and use is posted at the treatment plant and reclaim use sites for notification to employees. A review of files since last inspection in February 2020 shows a daily TSS limit exceedance in July 2021 and a daily ammonia exceedance in February 2022. Flow did not get discharged to the outfall in either event. The permit expires on February 28, 2023. A renewal application submittal will be required no later that six months prior to expiration. The GNF-A facility is compliant with the Non -Discharge Permit W00031317. Please review the comment sections of the inspection report for more details. Page 2 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-40A5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Infiltration System Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Activated Sludge Drip, LR Single Family Drip Recycle/Reuse Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Comment: No comment. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Treatment Flow Measurement -Effluent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: The effluent flowmeter was calibrated on 06/29/2021 Standby Power Is automatically activated standby power available? Carotek. Yes No NA NE ■❑❑❑ ■❑❑❑ Yes No NA NE ❑❑■❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE Yes No NA NE ■❑❑❑ ❑❑❑■ ■❑❑❑ ■❑❑❑ ■❑❑❑ Yes No NA NE ❑❑■❑ Page 3 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Comment: The facility has access to dual power sources, the Sutton Plant and the Castle Havne feed and power can be switched when one fails. A hook-up for a portable generator and a transfer switch is also available if needed. Treatment Barscreen Yes No NA NE Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? ❑ ❑ 0 ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Influent flows throuqh a mechanical screw screen followed by a 2 mm fine screen. Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? 0 ❑ ❑ ❑ Comment: From the 2 EQ tanks, wastewater flows through 2 anoxic tanks with nitrate recycle return, followed by 4 aeration basins with fine bubble diffusers. Each aeration basin has DO monitoring. DO was recorded at 2.96 mg/I in the third aeration basin. Mix liquor is typically 9500-10,000 mg/I. Treatment Return pumps Yes No NA NE Are they in place? 0 ❑ ❑ ❑ Are they operational? 0 ❑ ❑ ❑ Comment: No comment. Treatment Filters Is the filter media present? Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and filter media? Does backwashing frequency appear adequate? • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ Page 4 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Comment: The facility has 2 Membrane Bioreactor (MBR) units, each with 2 chambers consisting of 2 cassettes with 8 filtration modules per cassette. The 70,000 gallon units alternate after a set amount of filter/back pulse cycles. The MBR unis are cleaned annually with a chlorine and citric acid cleaning system. Treatment Sludge Storage/Treatment Yes No NA NE Is the aeration operational? 0 ❑ ❑ ❑ Is the aeration pattern even? ❑ ❑ ❑ If required, are Sanitary "Ts" present in tankage? ❑ ❑ ❑ ❑ Comment: Waste activated sludge is pumped to a series of 6 digesters. Solids from the digesters are treated, approximately once a week, with lime before and after it is processed through a filter press. Solids are then transfered to a covered storage area for further drying, bagged and sent to Envirocare Waste Disposal in Utah. Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (-30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑❑■❑ ■❑❑❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ ■❑❑❑ ❑❑❑■ ❑❑■❑ ❑❑■❑ ❑❑■❑ Comment: Disinfection consists of 2 UV units with 4 lamps each. Effluent is stored in a 20,000 qallon tank with a liquid chlorine infection pump to provide chlorine residual in the reclaimed utilization system. Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Page 5 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are flow rates less than of permitted flow? 0 ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ 0 ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ 0 ❑ Are all samples analyzed for all required parameters? ❑ ❑ 0 ❑ Are there any 2L GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ❑ ❑ 0 ❑ Is effluent sampled for same parameters as GW? ❑ ❑ 0 ❑ Do effluent concentrations exceed GW standards? ❑ ❑ 0 ❑ Are annual soil reports available? ❑ ❑ 0 ❑ # Are PAN records required? ❑ ❑ 0 ❑ # Did last soil report indicate a need for lime? ❑ ❑ 0 ❑ If so, has it been applied? ❑ ❑ 0 ❑ Are operational logs present? 0 ❑ ❑ ❑ Are lab sheets available for review? 0 ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ 0 ❑ Are Operational and Maintenance records present? 0 ❑ ❑ ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0 ❑ No treatment units bypassed since last inspection? 0 ❑ ❑ ❑ Comment: A daily check list is used by staff to document operations of the plant and a work order system is used for maintenance. Calibrations records and bench sheets for field parameters were complete and analyzed under the Field Certification # 166. Field instrumentation was calibrated and verified by Envirochem on 2/3/2022. All other required parameters are analyzed by Envirochem, Certification #94. End Use -Reuse Is the acreage in the permit being utilized? Does the acreage specified in the permit correspond to the measured acreage at the site? Are all essential units provided in duplicate? Is an automatically activated standby power source available? Is the equalization capacity adequate? Is aerated flow equalization present? Has the turbidity meter been calibrated in the last 12 months? Does the turbidity meter have recording capabilities? Is all flow diverted at the appropriate times? Is all upset wastewater diverted from reuse storage unit? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ Page 6 of 7 DocuSign Envelope ID: 3BF32E40-AA5E-4OA5-AB29-74COF65F6862 Permit: WQ0031317 Owner - Facility: Global Nuclear Fuel - Americas LLC Inspection Date: 03/18/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is all upset wastewater treated, retreated, or disposed of acceptably? 0 ❑ ❑ ❑ Is upset wastewater treated prior to discharge to irrigation storage? ❑ ❑ 0 ❑ Is public access restricted from irrigation area during active site use? ❑ ❑ 0 ❑ If golf course, is a sign posted in plain sight on the club house? ❑ ❑ 0 ❑ Is the cover crop acceptable? ❑ ❑ 0 ❑ Are buffers adequate? ❑ ❑ 0 ❑ Is the site free of ponding/runoff? ❑ ❑ 0 ❑ Is the acreage in the permit being utilized? ❑ ❑ 0 ❑ Is the application equipment acceptable? ❑ ❑ 0 ❑ Is the application area free of limiting slopes? ❑ ❑ 0 ❑ How close is the closest water supply well? ❑ ❑ 0 ❑ Are any supply wells within the CB? ❑ ❑ 0 ❑ Are any supply wells within 250' of the CB? ❑ ❑ 0 ❑ Is municipal water available in the area? ❑ ❑ 0 ❑ Are GW monitoring wells required? ❑ ❑ 0 ❑ Are GW monitoring wells located properly w/ respect to RB and CB? ❑ ❑ 0 ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ 0 ❑ Comment: The turbidity meter was calibrated on 03/17/2022 and is calibrated on a quarterly schedule by facility maintenance staff. Reclaimed effluent is stored in the 20,000 gallon tank and used for facility cooling towers. The flow can be discharged to Outfall 002 of NPDES Permit NC0001228 if the demand for coniuctive reclaim use decreases or reclaim standards are not met. This outfall discharges to the Northeast Cape Fear River. Page 7 of 7