Loading...
HomeMy WebLinkAboutNC0035041_Compliance Evaluation Inspection_20220328ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality March 28, 2022 Mr. Tony Konsul Carolina Water Service, Inc. of NC, LLC Post Office Box 240908 Charlotte, NC 28224 SUBJECT: Compliance Evaluation Inspection Hemby Acres WWTP NPDES Permit #NC0035041 Union County, NC Mr. Konsul: On March 24, 2022, Roberto Scheller of this Office conducted an inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to ensure compliance with permit requirements and conditions. At time of inspection, the subject facility appeared to be well maintained and operated. We wish to thank your operating staff for their assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact Roberto Scheller, of the Mooresville Regional Office, at 704-663-1699 or roberto.scheller@ncdenr.gov. Enclosure: Inspection Report Cc: LaserFiche NORTH CAROLINA DE mo.m.m or Environmental w.i� Sincerely, ,—DocuSigned by: `—A14CC681 AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11611 Mail Service Center I Raleigh, North Carolina 27699-1611 919.707.9000 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL I 21IIIIII NPDES yr/mo/day Inspection 3 I NC0035041 111 121 22/03/24 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 70I3 I 711 1 72 I N I 73I 1 74 71 I I 1 I I I I I I I80 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES Dermit Number) Hemby Acres WWTP 7803 Idlewild Rd Indian Trail NC 28079 Entry Time/Date 10:26AM 22/03/24 Permit Effective Date 19/02/01 Exit Time/Date 11:58AM 22/03/24 Permit Expiration Date 23/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Thomas C Capps/ORC/704-361-5067/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Richard Haver,PO Box 240908 Charlotte NC 282240908/Area Manager/704-525-7990/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signatur Roberto Scheller s 4911r§t31f(s) Agency/Office/Phone and Fax Numbers V Date 3/28/2022 DWR/MRO WQ/707-235-2204/ 91C2A007838943E... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: 3/28/2022 Page# 1 "-A14CC681AF27425... 31 NPDES yr/mo/day N C0035041 111 121 22/03/24 I17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On March 24, 2022 a Compliance Evaluation Inspection (CEI) was conducted at HembyAcers WWTP. Permit for this facility (NC0035041) became active February 1, 2019 and expires October 31, 2023. Discharge from treatment facility is via permitted Outfall #001 into the North Fork of Crooked Creek, which is classified as Class C waters in the Yadkin Pee -Dee River Basin. 12-Month review of compliance history for the period February 2021 through January 2022, found no reported permit limit violations. The permitted facility is a 0.3 MGD WWTP consisting of Influent Pump Station, Micro Screen (Bar Screen), 2-Aeration Basins, 2-Secondary Clarifiers, 2-Tertiary Filters, Liquid Chlorine (Sodium Hypochlorite), Liquid De -chlorination (Sodium Bi-Sulfite), Post Aeration, Continuous Flow Measurement, and Back-up Generator. At time of inspection effluent was clear with no visible suspended solids. Page# 2 Permit: NC0035041 Inspection Date: 03/24/2022 Owner- Facility: Hemby Acres WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? El El • El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: Permit effective February 1, 2019 and expires on October 31, 2023. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Records were current and readily available for review. Laboratory Are field parameters performed by certified personnel or laboratory? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE Page# 3 Permit: NC0035041 Inspection Date: 03/24/2022 Owner- Facility: Hemby Acres WWTP Inspection Type: Compliance Evaluation Laboratory Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ❑ Comment: Facility use contract lab K&W Laboratory, Certification # 559, and on -site Field Lab Certification #5228. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Bar screen had been replaced with Micro Screen. Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Surface Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? • ❑ ❑ ❑ Are the diffusers operational? ❑ ❑ • ❑ Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ • Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ ❑ ❑ • Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 4 Permit: NC0035041 Inspection Date: 03/24/2022 Owner- Facility: Hemby Acres WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Comment: At time of inspection effluent from secondary clarifers was clear with few visible suspended solids. Sludge blanket was at 16 to 18 inches. Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Comment: Disinfection -Liquid Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: De -chlorination Type of system ? Yes No NA NE Down flow • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE Liquid Page# 5 Permit: NC0035041 Inspection Date: 03/24/2022 Owner- Facility: Hemby Acres WWTP Inspection Type: Compliance Evaluation De -chlorination Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Are the tablets the proper size and type? Comment: Sodium Bi-Sulfite is used for de -chlorination. Are tablet de -chlorinators operational? Number of tubes in use? Comment: Yes No NA NE ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ El El Is sample collected below all treatment units? • El El El Is proper volume collected? • El ❑ ❑ Is the tubing clean? ■ El El El # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • El El El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El El representative)? Comment: At time of inspection effluent sampler was recorded at 4 degrees Celsius. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Flow meter was calibrated last on December 13, 2021 by B.W. Allen Co. At time of inspection Flow meter was recording 284.7 GPM. Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Yes No NA NE Page# 6 Permit: NC0035041 Inspection Date: 03/24/2022 Owner- Facility: Hemby Acres WWTP Inspection Type: Compliance Evaluation Standby Power Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Generator maintained by Kraft Power, Inc. Yes No NA NE • ❑ ❑ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MODE Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Process control include 30-minute Settleable Solids Test and Percent Solids Test. Aerobic Digester Yes No NA NE Is the capacity adequate? • ❑ El El Is the mixing adequate? • ❑ ❑ ❑ Is the site free of excessive foaming in the tank? • El El El # Is the odor acceptable? • ❑ El El # Is tankage available for properly waste sludge? • El El El Comment: Page# 7