HomeMy WebLinkAboutWQ0013398_Monitoring - 02-2021_20210407FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page
Permit No.: WQ0013398
Facility Name: Sandpiper Bay WWTF
County: Brunswick
Month: February
Year: 2021
PPI: 001
F=low Measuring Point: ❑ Influent I]' Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent 0 Effluent ❑ Groundwater Lowering ❑ Surface Water
Parameter Code P
50050
00310
00600
00665
50060
31616
00610
00625
00620
00400
00530
00076
ca
�
U F
O
N
c
U
O
U
OC
Z
N
m 0
B
'
QC
EF
V
t
U
OW
Qd
F-
Y Z�
Z
CL
'tOoI
m a Um
F
24-hr
hrs
GPD
mg/L
m /L
m /L
m /L
#/100 mL
mg/L
mg/L
mg/L
su
m /L
NTU
1
07:00
4
59,000
0.5
6.9
1
2
0700
4
61,000
0.5
6.9
1
3
0700
4
52,000
0.5
6.9
1
4
0700
4
57,000
0.5
6.9
1
5
07.00
4
59,000
v'
0.5
6.9
1
,.
6
07:00
4
61,000
0.5
6.9
1
71
07:00
4
59,000
0.5
6.9
1
81
07:00
4
61,000
0.5
6.9
t
9
07:00
4
57,000
0.5
6.9
1
10
0700
4
61,000
< 2
27.4
3 94
0.5
0.2
>0.5
27.3
69
3.3
1
11
07 00
4
59,000
0.5
6.9
1
12
0700
4
61,000
Q.5
6.9
i
13
07:00
4
52,000
0.5
6.9
1
141
07:00
4
57,000
0.5
69
151
07:00
4
71,000
0.5
6.9
1
161
07,00
1 4
6t.000
0.5
6.9
1
171
07:00
1 4
66,000
0.5
6.9
1
181
07:00
4
61.000
0.5
6.9
t
191
0700
4
57,000
0.5
6.9
1
201
07:00
4
61,000
05
6.9
1
211
07:00
4
61,000
0.5
6.9
1
22
07:00
4
52,000
05
6.9
23
07:00
4
61,000
0.5
6.9
_
1
24
07:00
4
61,000
<2 ~
26.2
0 57
0.5
<1
<0.2
<0 5
262
6.9
<2.5
1
_
25
07:00
4
57,000
0.5
6.9
1
26
07:00
4
57,000
0.5
6.9
1
271
07:00
4
52,000
0.5
6.9
1
�'
281
07 00
4
61 000
0.5
6.9
1
29
30
F`
31
Average:
59,179
0.00
26.80
2.26
0.50
1,00
0.10
0.00
26.75
1.65
1.00
Daily Maximum:
71,000
2,00
27,40
3.94
0.50
1,00
0.20
0,50
27.30
6 90
3,30
1 00
Daily Minimum:
52,000
2.00
2620
0,57
0.50
1.00
0,20
0.50
26.20
6.90
2.50
1,00
Sampling Type:
Recorder
Composite
Composite
Composite
Grab
Grab
Composite
Composite
Composite
Grab
Composite
Recorder
Monthly Avg. Limit:
150,000
10
14
4
Daily Limit:
15
25
6
6 to 9
10
10
Sample Frequency:
Continous
2 X Month
2 X Month
2 X Month
5 X week
2 X Month
2 X Month
2 X Month
2 X Month
5 X week
2 X Month
Continous
Certified Laboratories
Name: Sunny Wright Name: s_nvironmental Chemist / Wilimington NC
Name: Name:
Does all monitoring data and s ampling frequencies meet the requirements in Attachment A of your permit? Compliant _X_ Not Compliant _
If the facility is non -compliant, pleas, � explain in the spa below the reason(s) the facility was not in compliance. Provide in your explanation the date(!) of the non-compliance
and describe the corrw.-tive action(s) takem Attach additional sheets if n
C
Opera or in Responsible 1:harge (ORC) Certi `ication iPermittee
Certification
ORC: Sunny Wright 7
Permittee:
Certification No.: 28813
Signing Official: Timothy Tilma
Grade: II Phone Number 910-81 10-4178
Has the ORC ( hanged since the previous NDPIR? No
Signing Official's Title: General Manager
Phon umber: 917 084 Permit Exp 6/20/20i�j
Signature Date
Sig re Date
By this signat ire, I certify that thi ; report is accurrat i to best of my
I certify, under penalty of law, that this document and all attachments were prepared under racy
know ledge
direction or supervision in accordance with a system designed to assure that all qualified pers')nnel
properly gathereJ and evaluated the information submitted.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617