HomeMy WebLinkAboutNCG520013_Permit (Issuance)_19931209State of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes,Secretary
A. Preston Howard, Jr., P.E., Director
Mr. Charles Burnell, Jr.
Larco Construction
P. O. Box 16279
Winston-Salem, NC 27115-6279
Dear Mr. Burnell:
vati75411jr; r A
Admigiosw.m.07.0.0ftimajr
LD IE f—I I Ii
December 9, 1993
Subject: NPDES No. NCG520013
Nello Teer Co.-Pilcher and
Poindexter Sites
Yadkin County
In accordance with your request received November 18, 1993, the subject permit
modification. The only change in this permit is to indicate two (2) outfalls on the Certificate of
Coverage page of the subject General Permit. Enclosed please find the updated Certificate of
Coverage page for the subject permit. This page should be inserted into your current permit
and the old page discarded. This permit is issued . pursuant to the requirements of North
Carolina General Statute 143-215.1 and the Memorandum of Agreement between North
Carolina and the U. S. Environmental Protection Agency dated December 6, 1983.
If any parts, measurement frequencies or sampling requirements contained in this
permit are unacceptable to you, you have the right to an adjudicatory hearing upon written
request within thirty (30) days following receipt of this letter. This request must be in the
form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes,
and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North
Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding.
Please take notice that this permit is not transferable. Part II, E.4. addresses the
requirements to be followed in case of change in ownership or control of this discharge.
This permit does not affect the legal requirement to obtain other permits which may be
required by the Division of Environmental Management or permits required by the Division of
Land Resources, Coastal Area Management Act or any other Federal or Local governmental
permit that may be required.
If you have any questions concerning this permit, please contact Susan Robson at telephone
number 919/733-5083.
cc: Mr. Jim Patrick, EPA
Winston-Salem Regional Office
`Compliance
Central Files
Technical Support Branch
Kim Brantley
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES
DIVISION OF ENVIRONMENTAL MANAGEMENT
GENERAL PERMIT NO. NCG520000
CERTIFICATE OF COVERAGE NO. NCG520013
TO DISCHARGE SAND DREDGING WASTEWATER AND SIMILIAR WASTEWATERS UNDER THE
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
Nello Teel. Company
is hereby authorized to continue operation of a treatment system consisting of primary settling tanks for cyclone and
settling basins in series with the discharge of treated wastewater from two outfalls from a facility located at
the Pilcher and Poindexter Sites
NCSR 1716
Yadkin County
to receiving waters designated as the Yadkin River in the Yadkin/Pee-Dee River Basin
in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III
and IV of General Permit No. NCG520000 as attached.
This certificate of coverage shall become effective November 30, 1993
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day November 30, 1993
eston ` .f r., P.E., Director
Division of Environmental Management
By Authority of the Environmental Management Commission
State of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., P.E., Director
D. A. Lineberry
4130 N. Glenn Ave.
Winston-Salem, NC 27105
Av 9
41F
ff) Fi
October 29, 1993
Subject: General Permit No. NCG520000
Nello Teer Co. - Pilcher Facility
COC NCG520013
Yadkin County
Dear Mr. Lineberry:
In accordance with your application for discharge permit received on October 1, 1992, we are
forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general
permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the
Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated
December 6, 1983.
If any parts, measurement frequencies or sampling requirements contained in this permit are
unacceptable to you, you have the right to request an individual permit by submitting an individual permit
application. Unless such demand is made, this certificate of coverage shall be final and binding.
Please take notice that this certificate of coverage is not transferable except after notice to the Division
of Environmental Management. The Divsion of Environmental Management may require modification or
revocation and reissuance of the certificate of coverage.
This permit does not affect the legal requirements to obtain other permits which may be required by the
Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area
Management Act or any other Federal or Local governmental permit that may be required.
If you have any questions concerning this permit, please contact Ms. Susan Robson at telephone number
919/733-5083.
Sincerely,
Original Signed By
Coleen H. Sullins
A. Preston Howard, Jr., P. E.
cc: Fran McPherson
Winston-Salem Regional Office
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES
DIVISION OF ENVIRONMENTAL MANAGEMENT
GENERAL PERMIT NO. NCG520000
CERTIFICATE OF COVERAGE NO. NCG520013
TO DISCHARGE SAND DREDGING WASTEWATER AND SIMILIAR WASTEWATERS UNDER THE
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
Nello Teer Company
is hereby authorized to continue operation of a treatment system consisting of primary settling tanks for cyclone and
settling basins in series with the discharge of treated wastewater from a facility located at
Pilcher Facility
NCSR 1716
Yadkin County
to receiving waters designated as the Yadkin River in the Yadkin/Pee-Dee River Basin
in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III
and IV of General Permit No. NCG520000 as attached.
This certificate of coverage shall become effective October 29,1993
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day October 29,1993
Original Signed By
Coleen H. Sullins
A. Preston Howard, Jr., P.E., Director
Division of Environmental Management
By Authority of the Environmental Management Commission
Nello L. Teer Co.
Larco Construction Company
Pilcher Site
Lat 36° 03' 22"
Long 80° 30' 33"
USGS Quad No: C16SE
USGS Quad Name: Farmington
r• ;r xr .;tr4.: „}.:.3:;:F �•;�.f" : ad'-:f,:'•.'Y " . w; -,: 'i• +: ; 1'��� '"�5.:
f «` •'t%�e�:';: - M1�iq�}3i:;r:'i�} . «�:i-�:•'' � - • ::' :": '{.' . .. .. '' , .t. ..:i�s.i- ? •�E:.: , :•�......;.d ;�}�...Y.'y'�%5:..�.
cc:
Permits and Engineering
Technical Support Branch
Yadkin County Health Dept.
Central Files
WSRO
To: Permits and Engineering Unit
Water Quality Section
Date: July 27, 1993
03-0''1-0 a
1AP\Li,-� �� J (f -
NPDES STAFF REPORT AND RECOMMENDATION
County Yadkin
NCG 5zoot3
Permit No. NCG0200-37
PART I - GENERAL INFORMATION
1. Facility and Address: Nello L. Teer Co.
Larco Construction Division
4130 N. Glenn Ave.
Winston-Salem, NC 27105
2. Date of Investigation: July 22, 1993
3. Report Prepared by: Corey Basinger
Environmental Engineer
4. Persons Contacted and Telephone Number: D. A. Lineberry, VP
(919) 767-3500
5. Directions to Site: From WSRO, take Hwy 421 west. Travel
across the Yadkin River and take the first exit and continue
south on Baltimore Road. Go to SR 1001 and turn right and
continue to Farmington Road (SR 1716). Turn left on
Farmington Rd. and travel 1.3 miles, and the entrance is on
the left.
6. Discharge Point(s), List for all discharge points:
Latitude: 36° 03' 22" Longitude: 80° 30' 33"
U.S.G.S. Quad No. C16SE U.S.G.S. Quad Name Farmington
7. Site size and expansion area consistent with application?
Ample area is available at the site for expansion of
treatment systems.
8. Topography (relationship to flood plain included): The site
is adjacent to the Yadkin River and is in the flood plain.
PLOTTED
9. Location of nearest dwelling: No dwellings exist within
1000 feet of the site.
10. Receiving stream or affected surface waters:
Yadkin River
a. Classification: WS III
b. River Basin and Subbasin No.: 03-07-02
c. Describe receiving stream features and pertinent
downstream uses: The river flows downstream through
agricultural land for miles.
Part II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS
1. a. Volume of Wastewater to be permitted: 2100 GPM per
discharge (Ultimate Design Capacity)
b. What is the current permitted capacity of the Waste
Water Treatment facility? same as above
c. Actual treatment capacity of the current facility
(current design capacity)? same as above
d. Please provide a description of existing or
substantially constructed wastewater treatment
facilities; The system consists of primary settling
tanks for cyclone and settling basins in series.
e. Possible toxic impacts to surface waters: none
2. Residuals handling and utilization/disposal scheme:
a. Disposal/utilization scheme (Specify): Settled solids
removed from the settling basin twice per year and are
sold to landscapers as topsoil.
3. Treatment plant classification (attach completed rating
sheet). Less than 5 points - not classified.
4. SIC Code(s): 1442
Primary 43 Secondary
Main Treatment Unit Code: 5 0 0 x 0
PART III - OTHER PERTINENT INFORMATION
1. Is this facility being constructed with Construction Grant
Funds or are any public monies involved. (municipals only)?
N/A
NPDES Permit Staff Report
2. Special monitoring or limitations (including toxicity)
requests: Recommended that no monitoring be required.
PART IV - EVALUATION AND RECOMMENDATIONS
This staff report is in reference to Nello L. Teer Co.,
which has been assigned Permit No. NCG020037. The particular
site in question is the Pilcher Site (see map). Nello L. Teer
Co. Larco Construction Division, has filed a Notice of Intent
Requesting Coverage Under the Mining Activities General NPDES
Permit NCG020000. The Pilcher Site is a sand dredging operation
located on the Yadkin River.
This office has no objection to granting this request.
Environme tal Engin"er
27,/4.y /993
/ Date
W--7?
Water Quality Region 1 Supervisor Date
i
aTtil 'IMES
111111414;14600 0
Ir•
C.
c •1
c•
:
•
ELLO L. TEEM COMPANY
A Member of THE BEAZER GROUP
P.O. BOX 1131 DURHAM, N.C. U.S.A. 27702
OFFICE TEL: (919) 682-8191 • TELEX: 6711650 • FAX: 688-4898
•
September 30, 1992
Hs. Coleen Sullins
NC Dept. of Environment, Health
and Natural Resources
Water Quality Section
P. 0. Box 29535
Raleigh, NC 27626-0535
Dear Hs. Sullins:
RECEIVE
N.C.Dept. at
JUN 2F, 1943
Winston Sat_:.
RegiOfla= Office
Please find enclosed a Notice of Intent Requesting Coverage
Under the Mining Activities General NPDES Permit NCG020000 for
Larco Construction's Pilcher Pit. Also enclosed with this
application is a copy of the mining permit for this site and a
check in the amount of $400.00.
If you should have any questions, please do not hesitate to
call.
SSE/dg
Enclosures
cc: File
Sincerely,
Steven S. Edgerton, P.G.
ASSIGNED TO......-.Z...7114.21
D U E DATE %-
FOUNDED 1909
•
fr.)
MA"
FOR AGENCY USE ONLY
1TE RECEIVED
IlLICICANWSAMOME
VENOM
�4:i113�i ��'jo �
(J[�V MA
0
MONTH
111110101111
DAY
Azoot50
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
NOTICE OF INTENT REQUESTING COVERAGE UNDER THE
MINING ACTIVITIES GENERAL NPDES PERMIT NCG020000
Complete this Notice of Intent (NOI) and mall to the following address
North Carolina Division of Environmental Management
Water Quality Section, NPDES Group,
P.O. Box 29535
Raleigh, North Carolina, 27626-0535
The NOI must be accompanied with a general permit filing fee of $400.00. The check should be
made out to the North Carolina Department of Environment, Health, and Natural Resources.
Facility Owner/Operator Information;
Name: Nello L. Teer Co. Larco Construction Division
Address: 4130 N. Glenn Ave.
Cfy:
Zip•
27105 Phone:( 919) 767-3500
Facility Location Information
Name: Larco Construction Pilcher Pit
Address: Farmington Road
State: N` gyp:
City: .
Yadkin Phonef919 ) 767-3500
Winston-Salem,
County:
State: North Carolina
Physical Location Information:
(Street address, state road number, distance and
attach a copy of a county map or USGS quad with the
SR 1716, approx. 1.3 miles south of
direction from roadway intersection, aii.d
location of the facility marked on the map.)
SR 1001. Yadkin County NC
[Agency use only: Latitude Longitude 1
NOI 02 PAGE 1
a•
/4
l
. Type of minerals mined at this facility:.
River sand
Standard Industrial Classification (SIC CODE): 14 (for activity for which the facility is
primarily engaged)
This is an x existing facility or a _ proposed facility.
If proposed, date operation is to begin
Discharges are to Yadkin River
(name of receiving waters or, if to a separate
storm sewer system, name of the separate storm sewer system)
A. Does this facility have any NPDES Permits? des _no If yes, NPDES No. Nc0067890
B. Are vehicle maintenance activities occurring on site? _ yes Xno
C. Are mine dewatering discharges occurring? _ yes x no
D. Are discharges of overflows from process wastewater treatment systems occurring? _yes x no
If yes, complete the following on the wastewater treatment system:
1. Please describe the type of process used to treat and/or recycle the process
wastewater. Give design specifics (Le. design volume, retention time, surface area,
etc.). Existing treatment facilities should be described in detail and design criteria or
operational data should be provided (including calculations) to ensure that the facility
can comply with requirements of the General Permit.
NOTE: Construction of any wastewater treatment facilities require submission of three (3)
sets of plans and specifications along with their application. Design of treatment
facilities must comply with requirements 15A NCAC 2H .0138. If. constrUction of
wastewater treatment facilities applies to the discharge of process wastewater,
include three sets of plans and specifications with this application.
2. Does this facility employ chemical additives to flooulate suspended solids? _yes x no
If yes, please state the name, manufacturer and the quantity of average daily usage of
the chemical additive.
3. Does this facility overflow only during rainfall events exceeding the 10-year, 24-hour
rainfall event? ,_,yes x no
E. Does this facility employ any best management practices for stormwater control? _„yes gno
If yes, please describe
NOI 02 PAGE 2
I
Number of discharge points
Mine Dewatering ___; Stormwater
Process Wastewater Overflows ___;
Please provide short. narrative description of discharges The sand and gravel from the
river is pumped to a screen where the sand and stone -is separated from the
water medium and then the water is returned to the river through a pond.
•
I hereby request coverage under the referenced General Permit. I understand that coverage
under this permit will constitute the permit requirements for the discharge(s) and is
enforceable in the same manner as an individual permit.
I agree to abide by the following as a part of coverage under this General Permit:
1. I agree to abide by the approved Mining Permit for this mining activity. (A copy of the valid mining
permit must be attached to this request.
2. I agree to not discharge arty sanitary wastewater from this mining activity except under the
provisions of another NPDES permit specifically issued therefore.
3. I agree that bulk storage of petroleum products and other chemicals shall have adequate protection so
as to contain all spills on the site.
4. I agree that solid wastes will be disposed of in accordance with N.C. statutes and rules goveming
solid waste disposal.
5. I agree that maintenance activities for vehicles and heavy equipment will be performed so as to not
result in contamination of the surface or ground waters. •
I agree to abide by the provisions as listed above and recognize that the provisions are to be considered
as enforceable requirements of the General Permit.
I certify that I am familiar with the information contained in the application and that to the best of my
knowledge and belief such information is true, complete, and accurate.
- a,L�c ,A 9/30/92
signature
D. A. Lineberry
date
Vice President' •
name of person signing above (printed or typed) title
North Carolina General Statute 143-215.6B (i) provides that: Any person who knowingly
makes any false statement, representation, or certification In any application, record, report,
plan or other document filed or required to be maintained under Article 21 or regulations of the
Environmental Management Commission implementing that Article, or who falsifies, tampers
with or knowingly renders inaccurate any recording or monitoring device or method required to
be operated or maintained under Article 21 or regulations of the Environmental Management
Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine
not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C.
Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not
more than 5 years, or both, for similar offense.)
NOI 02 PAGE 3
cc: Permits and Engineering
Technical Support Branch
County Health Dept. FEB '' 71992
Central Files
WSRO , ;BRANCH
Date February 5, 1992
NPDES STAFF REPORT AND RECOMMENDATIONS
County Yadkin
NPDES Permit No. e-8-6-7-8-9-O
PART I - GENERAL INFORMATION - Renewal/Permit Modification
1. Facility and Address:
Larco Construction, Inc.
P. 0. Box 16296
Winston-Salem, N.C. 27115
2. Date of Investigation: 01-29-92
0�- O"I-0-
3. Report Prepared by: David Russell, Environr
Specialist, WSRO
4. Persons Contacted and Telephone Number:
Roger Sizemore, Plant Superintendent and Charles Burnell,
Jr. Vice President Larco Construction (Division of Nello
Teer Co.) (919) 767-3500
5. Directions to Site:
From Winston-Salem travel Hwy 421 West. Cross the Yadkin
River and take the first exit and travel south on Baltimore
Road. Go to SR 1001 and turn right and travel to Farmington
Rd. (SR 1716) turn left and go 1.3 mile, the entrance is on
the left.
6. Discharge Point(s) - List for all discharge points
001
Latitude: 36° 03' 22"
Longitude: 80° 30' 33"
002
Latitude: 36° 04' 07"
Longitude: 80° 30' 36"
Attach a USGS Map Extract and indicated treatment
plant site and discharge point on map.
USGS Quad No. C16SE or
USGS Quad Name Farmington
7. Size (land available for expansion and upgrading):
Ample area is available at both sites for expansion of
treatment systems.
8. Topography (relationship to flood plain included):
Both sites are adjacent to the Yadkin River and are in the
flood plain.RakVil
P255 D
ti
r
9. Location of nearest dwelling: None within 1000 feet of
either site.
10. Receiving stream or affected surface waters: Yadkin River
a. Classification: WS III
b. River Basin and Subbasin No.: YAD 02
c. Describe receiving stream features and pertinent
downstream uses: The river flows through agricultural
land for miles downstream.
PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS
1. Type of wastewater: % Domestic
100% Industrial
a. Volume of Wastewater: 2100 GPM per discharge
(Design Capacity)
b. Types and quantities of industrial wastewater:
Water generated from pumping sand from the river.
c. Prevalent toxic constituents in wastewater:
None.
d. Pretreatment Program (POTWs only):
in development
should be required
approved
not needed
2. Production rates (industrial discharges only) in
pounds per day: Pilcher Site production - 50,000 to 60,000
tons/year of sand.
a. Highest month in the last 12 months: lbs/day
b. highest year in last 5 years: lbs/day
3. Description of industrial process (for industries only)
and applicable CFR Part and Subpart: Sand pumping with a
floating movable dredge.
4. Type of treatment (specify whether proposed or
existing): Primary settling tanks for cyclone and the two
settling basins in series.
5. Sludge handling and disposal scheme: Settled solids removed
from settling basin twice per year and are sold to
landscapers as topsoil.
6. Treatment plant classification: (attach completed rating
sheet) Less than 5 points - not classified.
7. SIC Code(s) 1442
Wastewater Code(s) Primary 43 Secondary
Main Treatment Unit Code: 5 0 0 0
PART III - OTHER PERTINENT INFORMATION
1. Is this facility being constructed with Construction
Grants Funds (municipals only)?
2. Special monitoring requests: Recommended no monitoring be
required.
3. Additional effluent limits requests:
4. Other:
PART IV - EVALUATION AND RECOMMENDATIONS
This staff report is for a renewal request for Permit No.
NC0067890 (Pilcher Site) but to include a modification to the
permit. The company submitted an application (NC0081582) in
December 1991, for another sand dredging site on the Yadkin
River. The new proposed site (Poindexter Site) is located
upstream, but adjacent to the Pilcher Site.
The company plans to continue to use the screening plant
located on the Pilcher Site. A single dredge would work the
Pilcher Site but the dredge could also be.moved to the Poindexter
Site and the sand slurry pumped approximately 2500 feet to the
Pilcher Site for screening and stockpiling. This plan of
operation would be used provided sand production is adequate from
these sites and the company's other sites.
However, should the need arise, the permit should allow for
both the Pilcher Site and the Poindexter Site to be operated at
the same time. If and when that happens, both sites would screen
and stockpile sand and both sites would have settling ponds. The
discharge flow from a single site would never exceed the pumping
rate (2100 gpm) of a single dredge.
It is recommended that the existing permit NC0067890 be
reissued, but modified to include the Poindexter Site located
just upstream. The Pilcher Site would be Discharge 001 and the
Poindexter Site Discharge 002.
Gl° 61'21 ‘/92
Signature of report prepa r
Water Quality Regiohal Supervisor
Date
•
In
t
LMco CoNslie4411oA►i
(D;v. 1' a ilo T7P,
111 Pi'IckQ 2
,741: ,
:.s resaNd42)c Tea Si/J2 ooZ
1:61C.*:, /6 SE t in; n AA)
•
• v
POTS DAM
860 000
FEET
W
5`
3993
T992
3991
3990