Loading...
HomeMy WebLinkAboutWQ0035929_Renewal Application_20220329Non -Discharge Branch Upload/Submittal Form NORTH CAROLINA EnWrvnmemfal Qualify Version 2 - Revised June 23, 2020 Initial Review Reviewer Thornburg, Nathaniel D Is this submittal an application? (Excluding additional information.)* Yes No Permit Number (IR) * WQ0035929 Applicant/Permittee Samuel F. and Jennifer D. Cherry Applicant/Permittee Address 226 Seaston Street Is the owner in BIMS? Yes No Is the facility in BIMS? Yes No Owner Type Individual Facility Name 3529 Christian Chapel Church Rd. SFR County Chatham Fee Category Single -Family Residence Fee Amount $0 Is this a complete application?* Yes No Signature Authority Signature Authority Title Signature Authority Email Document Type (if non -application) Email Notifications Does this need review by the hydrogeologist?* Yes No Regional Office CO Reviewer Admin Reviewer Complete App Date 03/29/2022 Below list any additional email address that need notification about a new project. Email Address Comments to be added to email notfication Comments for Admin Comments for RO Comments for Reviewer Comments for Applicant Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. Name* Sam Cherry Email Address* neverenoughguns@gmail.com Project Information Application/Document Type * New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Phone Number* 9194279494 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, NDAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. https://edocs.deq.nc.gov/Forms/NonDischarge_Monitoring_Report Permit Type: * Permit Number: * Applicant/Permittee * Wastewater Irrigation Other Wastewater Closed -Loop Recycle Single -Family Residence Wastewater Irrigation WQ0035929 Has Current Existing permit number Samuel F. and Jennifer D. Cherry Applicant/Permittee Address* 226 Seaston Street Facility Name* 3529 Christian Chapel Church Rd. SFR Please provide comments/notes on your current submittal below. Don't know how to combine file and email says to large. High -Rate Infiltration Reclaimed Water Residuals Other At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. * (Application Form, Engineering Plans, Specifications, Calculations, Etc.) Blueprint Scan - Samuel Cherry -1.pdf NC Permit 2.pdf NC Permit 4.pdf NC Permit 3.pdf NC Permit 1.pdf 49.01 MB 1000.9KB 1.04MB 1.4MB 1.1MB Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non - Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature fouttcf &Jy Submission Date 3/28/2022 / / / \ WOOD LINE WOOD LINE td, N PINE FOREST \\SOO, \ & TREATMENT SYSTEM PLAN 'i►7 ZONE 1 1945 LF ONE 3® 1978 LF 88'46 17" PROPOSED 2�2 POOL 20' X 40' 21,, N88'46'17"E 231.82' PROPOSED WELL D LINE r NC HWY 42 Vicinity Map (Not to Scale) PROPOSED 5—BEDROOM SURFACE DRIP IRRIGATION SYSTEM FOR THE 33.98 ACRE SAMUEL F. CHERRY PROPERTY LOCATED ON CHRISTIAN CHAPEL CHURCH ROAD IN SOUTHEASTERN CHATHAM COUNTY NOTES 1) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS. 2) PARCEL INFORMATION OBTAINED FROM CHATHAM COUNTY GIS. TWO FOOT CONTOURS FOR THE SUROUNDING AREA OBTAINED FROM NORTH CAROLINA DEPARTMENT OF TRANSPORTATION 3) THIS MAP DOES NOT REPRESENT A SURVEY. 4) SEE ATTACHED SOILS REPORT AND MAP FOR SOIL BORING AND KSAT LOCATIONS. SITE DATA TOTAL LOT AREA = 1,480,201 FT2 OR 33.98 AC. ZONE 1 EIGHT DRIPPER LINES TOTALING 1,945 LINEAR FT. MINIMUM 3' SPACING BETWEEN LINES. ZONE AREA = 8,771 FT2. ZONE 2 TEN DRIPPER LINES TOTALING 1,993 LINEAR FT. MINIMUM 3' SPACING BETWEEN LINES. ZONE AREA = 8,313 FT2. ZONE 3 NINE DRIPPER LINES TOTALING 1,978 LINEAR FT. MINIMUM 3' SPACING BETWEEN LINES. ZONE AREA = 8,583 FT2. ZONE 4 SEVEN DRIPPER LINES TOTALING 1,940 LINEAR FT. MINIMUM 3' SPACING BETWEEN LINES. ZONE AREA = 7,019 FT2. INDEX OF SHEETS SITE PLAN SITE LAYOUT SYSTEM DETAILS 2 3-7 100 GRAPHIC SCALE 0 50 100 200 APPROVED Noah Carolina Environmental Management Commission Division of Water Quality Date e l 3� ( 12__..� Permit # as' RECEIVEDIDENRIDWQ AUG 232012 Aquifer Protection Section s ,•'q S .?s % 400 ( IN FEET ) 1 inch = 100 ft. cia O V cu Bateman Civi a • 0 CU • N L a) w Ph: 919.577.1080 Fax: 919.577.1081 E 0 () 0 (0 E a) t0 E U > m r0 E a) i0 NCBELS Firm No. C-2378 Designed By: Drawn By: TMB TMB Checked By: BJK Scale: AS NOTED Date: 08/22/12 REVISED Project Number: 120147 SHEET 1 OF 7 NOTE: SEE ATTACHED SOIL MAP AND REPORT FOR SOIL BORING AND <SAT LOCATIO\S '23 \ KS) \ 2\\TRAND 20 \ \ \ CHECK VALVE WIRE FENCE 12"RETUFLUSH MANIFOLD GRAPHIC SCALE 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. TREATMENT SYSTEM SYSTEV LAYOLT 1" = 20' 103' (A, PRORQ D 0,S/0 X /0' PLY MANIFOLDS — AIR 3�EAK AND CLEANOUT SOIL AREA ZONE 1 ZONE 2 ZONE 3 ZONE 4 12" ZONE SUPPLY LINES UV DISINFECTION UNIT POWER SUPPLY DOSING PUMP E-Z TREAT SYSTEM SINGLE POD 2 "' FIELD FLUSH RETURN LINE 4,650 GALLON HELD DOSING TANK 1,200 GALLON RE-CIRCLULATIO TANK 2,065 GALLON SEPTIC TAN K e3 4 4 EFFLUENT FROM HOUSE w FLUSH RETURN LI SEPTIC TANK 4 ZONE E-Z SET HEADWORKS HYDRAULIC CONTROLLER POWER SUPPLY TO E-Z TREAT HEADWORKS POWER SUPPLY UV DISSINFECTION UNIT POWER SUPPLY FROM HOUSE POWER SUPPLY TO RE-CIRC PUMP APPROVED Nokth Carolina Environmental Management Commission Division of Water Quality Date Permit # v. 9-5) 3S sl OPERATION REGIME FOR 600 CPC) — 5 BEDROOM THE PRETREATMENT COMPONENT SHALL BE SET TO DOSE THE E-Z TREAT FILTER FOR 3 MINUTES AT 16 MINUTE INTERVALS DELIVERING A DOSE OF 2400 GALLONS/DAY OF SEPTIC TANK EFFLUENT. TREATED EFFLUENT LEAVING THE E-Z TREAT UNIT SHALL BE DIRECTED TO A FLOW SPLITTER (75% BACK TO THE E-Z TREAT RE-CIRC TANK, 25% FORWARD TO THE FIELD DOSING TANK). THE DRIP DISPERSAL SYSTEM SHALL BE CONTROLLED BY A MICROPROCESSOR WHICH ACTIVATE THE PUMP AND SEQUENCING OF THE APPROPRIATE FIELD SOLENOID VALVE, PRESET, VARIABLE, TIMER TO DELIVER 25 GALLONS TO EACH OF THE FOUR ZONES. SHALL BE REPEATED AT 4 HOUR INTERVALS PROVIDED THE DOSE ENABLE FLOAT IS A IF THE HIGH WATER ALARM FLOAT SWITCH IS ACTIVATED, THE SYSTEM WILL ENERGIZE AUDIBLE AND FLASHING ALARM. WILL AND RUN A THE CYCLE CTIVATED. TH E SPECIAL NOTES 1. THE CONTRACTOR MAY USE ANY STATE APPROVED TANK BUT SHALL INSURE THAT MINIMUM VOLUMES, I.A.W. CURRENT AND LOCAL HEALTH DEPARTMENT RULES ARE ACHIEVED. IF DIFFERENT PUMP TANKS ARE USED, THE CONTRACTOR SHALL CHECK THE FLOAT SEIIINGS TO INSURE THAT PUMPING VOLUMES ARE CONSISTENT WITH THE ORIGINAL DESIGN REQUIREMENTS. 2. THE SYSTEM SHALL BE INSTALLED BY A CONTRACTOR COMPLETELY ACCEPTABLE AND CERTIFIED BY THE MANUFACTURER. THE INSTALLATION SHALL ALSO BE CERTIFIED BY A REPRESENTATIVE OF THE MANUFACTURER AND SHALL INDICATE THAT THE PRODUCT HAS BEEN CONSTRUCTED IN ACCORDANCE WITH ALL MANUFACTURER RECOMMENDATIONS AND REQUIREMENTS. 3. ALL PROPOSED FIELD CHANGES SHALL BE PRE -APPROVED BY THE ENGINEER AND NCDENR. B TR EATIV E\T SYST-IV LAN \OT TO SCALE RECEIVEDIDENRIDWQ AUG 2 3 are Aquifer Protection Semen ,`p+4go�U�,00 ,,,, CAR '4,, w QUO e i C rts O U A 3 Bateman Civi CU i CL • 0 V) • a) LU Fax: 919.577.1081 0 CO 0 r- L0 0) 0) a 0 to N 0 z 0) a) 0 0 ro 0 6-5 z 0 0 N E 0 0 E' 6 E NCBELS Firm No. C-2378 Designed By: TMB Drawn By: TMB Checked By: BJK Scale: AS NOTED Date: REVISED 08/22/12 Project Number: 120147 SHEET 2 OF 7 150" 144" 78" 72" 20" 96" Top View Access openings to receive Concrete Lids, Rings / Covers, Aluminum Hatches, or as required 2— Side knockouts to receive 4" pipe or as required Length to Width Ratio: 2 to 1 Air Vent 20" Outlet w/ State Approved Rubber Boots or as required INVERT IN 269.33' 69" 55" r 4" H-20'--I Q 150" 144" TOP OF TANK 270.5 12" air space 61" 4" Side View 144" Air Vent 20" --I State Approved Effluent Filter 3" —• „ NVERT OUT 269.17' 53" } 62" 56" PT — 213 96" BOTTOM OF TANK 264.75' 2065 GALLON SEPTIC TANK NOT TO SCALE 90" Access Openings to receive Concrete Lids, Rings / Covers, Aluminum Hatch, or as required Side Knockouts to receive 4" pipe or as required Date: 08-18-93 Non Traffic Rated Liquid Capacity 1,21 1 Gallons 19 gals. per inch Manufactured By: Blackwelder Tank Service, Inc. 121 Stanton Hill Rd Carthage NC 28327 Phone 919 718-5181 Fax 919-775-2229 Blackwelder tank .com STB — 278 — Mid Seam Approval Date: 8-14-97 Uquid Capacity 2065 Gallons Non Traffic Rated Reinforcement Schedule: If 3 Grade 60 Reber 4500 PSI Concrete w/ State Approved Structural Fiber 4 Yds. Est Weigh: 46.0001bs Manufactured By: Blackwelder Tank Service, Inc. 121 Stanton Hill Rd. Carthage NC 28327 Phone 919-718-5181 Fax 919-775-2929 b/ajelder tank. am 1" Butyl Rubber Sealant 5" in all Jts. 96" 132" 119" 6" setback to secure Top 99" 120" TOP 9 24" Access Openings to receive Ring / Covers, Aluminum Hatches, or as required 24" Risers if Required brought to grade by Contractor TOP OF TANK I 24" 270.5 24 NVERT IN 269 0' 93" 87" Inlet / Outlet State approved Rubber Boots or as required Riser Inlet Side View BOTTOM OF TANK 6" -' (INVERT OUT 269.17' 120" 261.75' 132" 89" 4650 GALLON FIELD DOSING TANK TOP OF TANK 20" a • 269.84' 24" INVERT IN 269.09' 60" 56" Reinforcing Schedule: # 3 Grade 60 Rebar 4500 PSI Concrete w/ State Approved Structural Fiber 2.5 yds. Est Weight 8,900 Ibs 96" 90" Inlet 0 Inlet Port Opening 4" State approved Rubber Boots. Outlet Port Opening 2" State approved Rubber Boots Plain View Outlet 4 • 4 BOTTOM OF TANK 264.42' 1200 GALLON RECIRCULATION TANK BY BLACKWELDER NOT TO SCALE NOT TO SCALE INVERT OUT 268.92' 54" ALL TANKS SELECTED HAVE APPROVAL FROM THE OF ENVIRONMENTAL HEALTH SPECIAL NOTES 1. THE CONTRACTOR MAY USE ANY STATE APPROVED TANK BUT SHALL INSURE THAT MINIMUM VOLUMES, I.A.W. CURRENT AND LOCAL HEALTH DEPARTMENT RULES ARE ACHIEVED. IF DIFFERENT PUMP TANKS ARE USED, THE CONTRACTOR SHALL CHECK THE FLOAT SWINGS TO INSURE THAT PUMPING VOLUMES ARE CONSISTENT WITH THE ORIGINAL DESIGN REQUIREMENTS. 2. THE SYSTEM SHALL BE INSTALLED BY A CONTRACTOR COMPLETELY ACCEPTABLE AND CERTIFIED BY THE MANUFACTURER. THE INSTALLATION SHALL ALSO BE CERTIFIED BY A REPRESENTATIVE OF THE MANUFACTURER AND SHALL INDICATE THAT THE PRODUCT HAS BEEN CONSTRUCTED IN ACCORDANCE WITH ALL MANUFACTURER RECOMMENDATIONS AND REQUIREMENTS. 3. ALL PROPOSED FIELD CHANGES SHALL BE PRE -APPROVED BY THE ENGINEER AND NCDENR. PT — 535 North Carolina Approval Date: September 29, 2006 Non Traffic Rated Specifications Liquid Capacity 4650 Gallons Gallons Per Inch 50 Reinforcing Schedule: See Engineer Drawing 4500 PSI Concrete w/ State Approved Structural Fiber Est. Total Weight 40.0001bs. Manufactured By: Blackwelder Tank Service, Inc 121 Stanton Hill Road Carthage NC 28327 Phone 919-718-5181 Fax 919-775-2229 3/4" RECIRC UNE FIN. GRADE ECK VALVE FROM PUMP NOTE FOR INSTALLATION MUST NORTH CAROLINA DEPARTMENT (DEH) FOR THE INTENDED USE • 11 1.11r,I. 11-il=ci ?If.�f.l �1. 5/4 TREX BOARD TYPICAL OPTIONAL 2" VENT-4( CARBON FILTER (IF REQ. PER LOCAL CODE) E—Z TREAT POD FILTER SYSTEM SUPPLY UNE UNE 3° ALL AROUND SELECT BACKFILL FREE OF DEBRIS (6" INCHES) :N.11 11lI= = F=N.GE II=1= =11=MG GRADE T� TANKS REQUIRE A 6" THICK STONE BEDDING (TYP) ,0 n 3/4" BALL — VALVE (TYP.) SPRAY NOZZLE CYR) 30" RISER — SEE GEN. NOTES VALVE 1 1/2" UNE TO FILTER POD 4" PVC END CAP NOTE: Do NOT GLUE ONTO RISER PIPE DRILL 1/4" VENT HOLE IN CAP 4" PVC RISER PIPE — EXTEND ABOVE BOTTOM OF TANK UD INVERT IN 4" TO FINAL DISPOSAL TANK 269.09' ALL TANKS REQUIRE A 6" THICK STONE BASE (rYP) PRESSURE GAUGE --1" BALL VALVE u OPTIONAL 2" VENT & CARBON FILTER (IF REQ. PER LOCAL CODE) CONTROL PANEL 0". E—Z SET RISER WITH COVER (SEE NOTES) T aver TYP L 1 1/2" gz =RECIRC /--E—Z SET BYPASS Vr°LVE RECIRCULATION TANK VOLUME = 1200 411 E-Z SET RISER WITH COVER OPTIONAL 2" VENT & CARBON FILTER (IF REQ. PER L CODE) SEE TANK CHART 4" 24"4 E—Z SET RISER WITH COVER (TYP) 3/4" RECIRC ALL TANKS REQUIRE A 6" THICK STONE BASE (TYP. #57 WASHED OR EQUAL) OPTIONAL 2" VENT & CARBO FILTER (IF REQ. PER LOCAL CODE) 30"0 E—Z SET RISER WITH COVER. SEE NOTES ZOF1 I FR TURBINE PUMP (OR EQUAL) E—Z TREAT SYSTEM ASSEMBLY NOT TO SCALE APPROVED North Carolina Environmental Mmagernent Commission Division of Water Quality Date CP) (3 Di l Z - Permit # UOC9- 6U 3 S 9 2 a � INVERT OUT 268.92' EE PIPE PENETRATIONS NOTE (1YP) ANTI —SIPHON HOLE (1YP) LIGHT CONTROL PANEL (LOCATED WITHIN 10—FEET OF TANKS) cci 0. E rco V �> W 1,, ar rr,. r�r co +amE a) ca cJ) a) C co C1.. • Ph: 919.577.1080 Fax: 919.577.1081 v N co c E a3 111 -14 co g. w I I 0 ,ter LLI _0>- Qa. c0 rG+ W 1 z w Et 0 h ch U a z LL W m 0 z Designed By: TMB Drawn By: TMB Checked By: BJK Scale: AS NOTED Date: REVISED 08/08/12 Project Number: 120147 4„. /47/41, t to Fr NOTE: DESIGN FINISHED GRADE TO SHED WATER AWAY FROM TANKS MINIMUM 2' OF SOIL COVER FINISHED GRADE 272.5 ///////////, //ie /Jl .4//' 4/,�// .• ..11! !//III //Jl ////rI//' a - • 11111, SANITARY TEE ON INLET PRECAST CONCRETE TANK (MATERIAL STRENGTH > 3500 PSI) r1/7// /7/1/ ZTLET • INVERT OUT 269.17' taa `C4 :� �'i74`�4'� ChR t�♦ C t +♦ C1''ri t♦ r'Y• r4 ♦ rt t t +'• . NOTE 1. TANK DIMENSIONS VARY BY MANUFACTURER. SEPTIC TANK SCHEMATIC NOT TO SCALE GRAVITY SEWER AND FORCEMAIN TESTING SPECIFICATIONS DEFLECTION TESTING THE DEFLECTION TEST SHALL CONSIST OF MEASURING THE PIPE FOR VERTICAL RING DEFLECTION. MAXIMUM RING DEFLECTION OF THE PIPELINE UNDER LOAD SHALL BE LIMITED TO 5 PERCENT OF THE INTERNAL PIPE DIAMETER. ALL PIPE EXCEEDING THIS DEFLECTION SHALL BE CONSIDERED TO HAVE REACHED THE LIMIT OF ITS SERVICEABILITY AND SHALL BE RELAID OR REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S SOLE EXPENSE. THE DEFLECTION TESTING SHALL BE ACCOMPLISHED BY PULLING A MANDREL, SPHERE, PIN -TYPE "GO/NO GO" DEVICE THROUGH THE PIPELNE. THE DIAMETER OF THE MANDREL, SPHERE, "GO/NO GO" DEVICE SHALL BE 95 PERCENT OF THE UNDEFLECTED INSIDE DIAMETER OF THE FLEXIBLE PIPE. PRESSURE AND LEAK TESTING GENERAL 1. PRIOR TO TESTING ANY SEGMENT OF FORCE MAIN, CARE SHALL BE TAKEN TO PREVENT THE PIPE FROM MOVING WHILE UNDER PRESSURE. 2. TEMPORARY TAPS AND AIR RELEASES SHALL BE PERMISSIBLE TO FACILITATE TESTING. 3. WATER USED FOR TESTING FORCE MAIN INSTALLATIONS SHALL EITHER BE DISPOSED IN A NEARBY SANITARY SEWER, AS AUTHORIZED BY THE LOCAL SEWER AUTHORITY, OR IN ANOTHER LOCATION IN ACCORDANCE WITH STATE AND FEDERAL LAWS AND REGULATIONS. 4. ALL TESTING SHALL BE PERFORMED IN THE PRESENCE OF THE APPLICANT, THE PE, OR OTHER AUTHORIZED REPRESENTATIVE. 5. THE RESULTS OF ALL TESTING SHALL BE MAINTAINED BY THE APPLICANT AS PART OF THE CONSTRUCTION RECORD DOCUMENTATION. PRESSURE TESTING 1. A HYDROSTATIC PRESSURE TEST SHALL BE PERFORMED ON EACH SEGMENT OF INSTALLED FORCE MAIN. 2. THE TEST SHALL BE PERFORMED AFTER THE FORCE MAIN HAS BEEN BACKFILLED AND AT LEAST SEVEN DAYS FOLLOWING THE POURING OF THE LAST THRUST BLOCK. 3. THE FOLLOWING PROCEDURES SHALL BE FOLLOWED IN PERFORMING HYDROSTATIC PRESSURE TESTS ON FORCE MAINS: A. THE FORCE MAIN SEGMENT SHALL BE CAREFULLY FILLED WITH WATER AT A VELOCITY OF APPROXIMATELY THE FORCE MAIN SHALL BE TAKEN DURING THIS PROCESS. ONCE FULL OF WATER, THE FORCE MAIN SEGMENT SHALL BE PRESSURIZED AND ALLOWED TO STABILIZE AT A TEST PRESSURE OF 5 POUNDS PER SQUARE INCH. B. THIS PRESSURE SHALL BE MAINTAINED FOR AT LEAST ONE MINUTE PER 100 FEET OF LINE. Of2ENCO 4` BKITUBE EFFLUENT FLIER MODEL # FTPSO436-28-NC WNW r ICI ram MINE THE CAUSE OF TEST FAILURE IS DETERMINED, ALL NECESSARY REPAIRS ARE MADE, AND REPEATING THE 9.1T1EpR§iaic* TEWAIyNTIbAvI-i5EFNykC DSm4 N n EJ 1E PUMP STATION OR A TEMPORARY CONNECTION MADE IN THE FORCE MAIN. APPROPRIATE MEASURES NECESSARY TO ELIMINATE ALL AIR FROM LEAKAGE TESTING 1. A LEAKAGE TEST SHALL BE PERFORMED ON EACH SEGMENT OF INSTALLED FORCE MAIN AT THE HYDROSTATIC PRESSURE TEST DESCRIBED ABOVE. 2. LEAKAGE SHALL BE DEFINED AS THE QUANTITY OF WATER REQUIRED TO MAINTAIN A PRESSURE WITHIN FIVE POUNDS PER SQUARE INCH OF THE SPECIFIED TEST PRESSURE AFTER THE PIPE HAS BEEN FILLED MTHIFW I SWEEN-PRO§SLW girkgtiziOVWELkiliNTAINED, THE CONTRCTOR IS RESPONSIBLE FOR ASSURING THAT 3. LEAKAGE SHALL BE MEASURED WITH A CALIBRATED TEST METER AND SHALL NOT EXCEED THE AMOUNT GIVEN BY THE FOLLOWING FORMULA: L - ND JP ; T D= 7,400 P ALLOWABLE LEAKAGE (GALLONS PER HOUR) NUMBER OF JOINTS IN LENGTH OF PIPE SEGMENT TESTED NOMINAL DIAMETER OF PIPE SEGMENT TESTED (INCHES) TEST PRESSURE (POUNDS PER SQUARE INCH) ALL VISIBLE LEAKS SHALL BE REPAIRED REGARDLESS OF THE AMOUNT OF LEAKAGE. IF LEAKAGE EXCEEDS THIS RATE, THE CONTRACTOR IS RESPONSIBLE FOR ASSURING THAT THE CAUSE OF TEST FAILURE IS DETERMINED, ALL NECESSARY REPAIRS ARE MADE, AND REPEATING THE TEST UNTIL THE FORCE MAIN SEGMENT PASSES. INVERT IN 269.09' OPTIONAL 2" VENT & CARBO FILTER (IF REQ. PER LOCAL CODE) r 611110.111 HIGH LEVEL=269.171,.�)-�' 4" PVC CROSS DOSE ENABLE=266.88' WEIGHTED MERCURY FLOAT SWITCHES (2) ZOELLER TURBINE PUMP (OR EQUAL) RE -CIRCULATION TANK SCHEMATIC NOT TO SCALE ALARM LIGHT \--CONTROL PANEL (LOCATED WITHIN 10-FEET OF TANKS) FIPNS -ED GRADE 272.5 DIRECT BURY CABLE TO PANEL //////////// CHECK VALVE' ffffff////ffff LL,UUNNIIIOON r TO RECIRCULATING FILTE ` J//////�//// FROM SPUTTER VALVE ANTI --SIPHON HOLE (TYP) rrr r 07 ram MOM INVERT IN 269A' 4,47.1 60' 3000 GAL STORAGE OOMTROL PANELSEE DETAL / RAN SENSOR SEE DETAIL'v 1H E COH1RI PANEL SHALL HAVE AUOMLE AND VISUAL HIGH-WATER ALARMS. THE CONTROL PANEL ALARMS sHA L BE EMETRNAL TO ANY STRUCTURE. THE CONTROL PANEL SHALL BE HOUSED M A ff6MA 4X WEATHE7MROOF HOUSING. THECONTROL PANEL SHALL BE MOUNTED ON A POST WITHIN FIVE (5) FEET OF THE ACCESS RISER, LAG FLOAT TAMER OVERRIDE ENABLE.-266.42' 255.42' 3' Hill{ WATER ALARM LEVEL --MAT HIGH LEVEL - PIMP ON - 265.0` LOW LEVEL - PIMP OFF--- 2640 REDUNDANT PUMP I T'-'-263.92' 000LRNG JACKET & PIMP SUPPORT HOUSING PRONDED BY PUNAP MANUFACTURER NOTES 1.i TANK DIMENSIONS VARY BY MANUFACTURER. 2. DRAWDOWN WILL VARY WITH TANK DIMENSIONS. DRAWDOWN SHOWN BASED ON 600 GALLONS AT 50 GALLONS PER INCH 3. NO ELECTRICAL SPLICES SHALL BE MADE INSIDE THE PUMP TANK. 4 ALL HARDWARE INSIDE THE PUMP TANK SHALL BE OF STAINLESS STEEL. OPENING AROUND WIRES MUST rBE MADE VAPOR TIGHT MINIMUM 2' OF SOIL COVER INVERT OUT 269.17' ZOELLER FLOAT CTYP.) MODEL # 5033-0009 SUE PUMP PUMP TANK SCHEMATIC NOT TO SCALE NOTES 1. THE TANKS WILL NOT BE INSTALLED IN THE WATER TABLE. 2. ALL TANKS SHALL BE LEAK TESTED SUCH THAT EXFILTRATION OCCURS AT A RATE WHICH DOES NOT EXCEED TEN GALLONS PER TWENTY-FOUR HOURS PER 1,000 GALLONS OF TANK CAPACITY. 3. ALL TANKS SHALL REST ON A BED OF #57 WASHED GRAVEL. THE MINIMUM THICKNESS OF THE GRAVEL BED IS 6 INCHES. 4. ALL TANKS MUST BE APPROVED FOR USE BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL HEALTH (DEH). 5. THE SOIL BEARING CAPACITY OF THE SOIL BENEATH THE PUMP TANK SHALL BE CHECKED PRIOR TO TANK INSTALLATION AND SHALL HAVE A A SOIL BEARING CAPACITY OF AT LEAST 3000 PSF. 6. PIPE PENETRATIONS IN THE PUMP TANK AND SEPTIC TANK ARE TO BE SEALED WITH PRESS -BOOT TYPE SEALS. E- tiTREAT ILE.ADVORKS RRgT e �fff// „rimy �: S BDUT O Tiwrlr r *41 ram 310016 7. INVERTS SHOWN ARE APPROXIMATE. THE INSTALLER SHALL FIELD CONFIRM PRIOR TO CONSTRUCTION. 8. ALL HARDWARE INSTALLED INSIDE OF TANKS SHALL BE OF STAINLESS STEEL. 9. ELEVATIONS SHOWN ARE BASED ON THE SANCTUARY FINISHED FLOOR ELEVATION (FFE), WITH THE PLUMBING INVERT OUT BEING 4' BELOW FFE. THE INSTALLER SHALL VERIFY THE INVERT OUT ELEVATION AND MAKE ANY NECESSARY ADJUSTMENTS OPERATION AND MAINTENANCE ONCE PER MONTH 1. RECORD CYCLE COUNTERS AND RUN TIMER 2. CHECK SLUDGE LEVELS IN BOTH PUMP TANK AND SEPTIC TANK. SLUDGE TO BE REMOVED AS NECESSARY. 3. CHECK MANHOLES. CLEAN AS NECESSARY. 4. CHECK EFFLUENT FILTERS. CLEAN AS NECESSARY. ANNUALLY 1. FLUSH GRAVITY SEWER. 2. PUMP SLUDGE FROM SEPTIC TANK AND PUMP TANK. 3. EXERCISE ALL VALVES. 4. CLEAN MANIFOLD TAPS. 5. CHECK MANIFOLD HEAD PRESSURE. RESET AS NECESSARY. 6. CHECK PUMP TANK DRAW DOWN. APPROVED Noah Carolina Environmental M,. nagement Commission Division of Water Quality 41 Date ti3 C9-<.v 3 Sc a i Permit #31) j 2� '-13- 2C(a 0 E �ROIP >44 a) �IRw co ra 4.0 00 0 ai rn 0 CO 0 10 C7) a.. 0 N z c EL: co Z 0 0 N ti N Ea 0 Z rf) J 0 z SYSTEM DETAILS Drawn By: Checked By: Date: TMB BJK REVISED 0803/12 ect Number: 120147 SHEET d (IF 7 11" RETURN LINE TO "MI HEADWORKS UNIT I- SUP PVC TEE • • . / -L-- / RETURN MANIFOLD *" SLIP PVC TEE ..•.•.' • END OF SUPPLY UNE CLEANOUT & BOX MANIFOLD DRIPPER UNE CONNECTION (TYP.) " • , • . • • . • • • • • • • • • • • . • , . • • • • • • • . • • . • . L AIR VENT AND CHECK VALVE ED IN PROTECTIVE BOX (TYP.) —L_ ci11" SCH 40 PVC FIELD FLUSH RETURN UNE PVC SUPPLY UNE FROM HYURAUUC UNIT GEOFLOW LOCKSUP ADAPTER LTSUP-600 (ryP.) GLUE INTO 3/4 INCH PVC EMITTER TUBING LAID ON EXISTING GRADE UNDER 4-0 IN. OF MULCH WELL PACKED EARTHEN DAM 3 FT. MIN. GEOFLOW LOCKSUP COUPUNG LTC-600 (TYP.) BLANK GEOFLOW DRIPPER LINE FOR FIELDS IN WHICH LINES MAKE MULTIPLE PASSES THROUGH FIELD WITH SUPPLY AND RETURN UNES IN SAME TRENCH GEOFLOW LOCKSUP ADAPTER LTSUP-600 (TYP.) GLUE INTO 3/4 INCH PVC EMITTER TUBING LAD ON EXISTING GRADE UNDER 4-6 IN. OF MULCH BLANK GEOFLOW DRIPPER UNE FOR FIELDS IN WHICH LINES MAKE SINGLE PASSES THROUGH FIELD WITH SUPPLY AND RETURN LINES IN SEPARATE TRENCHES MANIFOLD —DRIP LINE CONNECTION NOT TO SCALE 0— TUBING W/0.53 GPH LABYRINTH DAITTIMS 0 2.0' 0.C. — GEOFLOW WASTEFLOW PC RETURN MANIFOLD PIPE t" SUP PVC TEE GEOFLOW LOCKSUP COUPUNG LTC-600 (TYP.) NOTE: TOTAL # OF LINES SHALL MATCH PLAN ED NOTE: SEE ley FOR CORRECT ORIENTATION OF EACH IRRIGATION ZONE. SELECT 1 24" MIN. BURY 24" MIN. BURY MANIFOLD TRENCH 24" WIDTH MIN. 0 LOOPED LATERAL — MAKES MULTIPLE PASSES ACROSS DRAINFIELD 0 0 01 0 STRAIGHT LATERALS — MAKE SINGLE PASSES ACROSS DRAINFIELD MANIFOLD TRENCH 24 WIDTH MIN. FI FCT BACKFI EMITTER T1 MING 4"— 6" TYPICAL DAM HEIGHT \‘*----‘"---12- BEYOND MANIFOLD TRENCH TO DRIPPERUNE CONNECTION 8" TUBING STAPLES 0 25' 0.C. NOTE PIPE LAYOUT SHALL VARY PER SYSTEM DESIGN FOR FIELDS IN WHICH UNES MAKE MULTIPLE PASSES THROUGH FIELD WITH SUPPLY AND RETURN UNES IN SAME TRENCH FILITITFR TUBING 6" TYPICAL DAM HEIGHT BEYOND MANIFOLD TRENCH TO DRIPPERUNE CONNECTION 8" TUBING STAPLES 0 25' 0.C. NOTE PIPE LAYOUT SHALL VARY PER STsiLM DESIGN FOR FIELDS IN WHICH UNES MAKE SINGLE PASSES THROUGH Flan WITH SUPPLY AND RETURN LINES IN SEPARATE TRENCHES SUPPLY/RETURN SECTION NOT TO SCALE DISTRIBUTION FIELD SCHEMATIC WITH CONNECTION DETAILS NOT TO SCALE OW LOCKSUP COUPUNG LTC-600 (TYP.) BLANK GEOFLOW DRIPPER LINE LOOP CONNECTION GEOFLOW LOCKSUP COUPUNG LTC-600 MP.) WELL PACKED EARTHEN DAMS BLANK GEOFLOW DRIPPER UNE GEOFLOW LOCKSUP ADAPTER LTSUP-600 (Tyr.) GLUE INTO 3/4 INCH PVC 1i" COUPUNG bli" SCH 40 PVC z 12"W x 181. MEILN BOX, WITH 6" EVENT1ON AND COVER —*AMETEK" 4 190106 & 190110 OR EQUAL X''AIR RELEASE VALVE AND CLEANOUT 1" THREAD DIAMETER li" TO 1" REDUCER 1i"SCH 40 PVC TEE r11" PVC SWING CH CK VALVE (SOLVENT WELD ENDS) 411411010111141141014.,4101411144:111N11#41044111( 04tillkyArAtrilltrAgeivAili .1441111-4.001401141Villi al -WOW MIIMIP.-riSWIWA. "b..1.,444011.11044411. amoe- iive- VW,' API* 4,14011.1**11Weritilke : • 24" x 24" x #57 WASHED STONE AIR RELEASE CHECK VALVE AND BOX NOT TO SCALE END CLEANOUT GATE VALVE SIZE THE SAME AS MANIFOLD PIPING 11"SCH 40 PVC TO FLUSH RETURN MAIN AND ULTIMATELY TO SEPTIC TANK APPROVED No, th Carolina Environmental Mmagement Commission Division of Water Quality Date Permit # U31)--C30 359 VALVE BOX WITH COVER /7-- lialar,iii7,4,044011 :111: till4"4141,Voir 414444360,41 Agife At ,iftr-'4, 4 I, r :4:11.:.141: b•-•in imo4 mew 43(404111,91,14ii w..likorirrif..4rAttiketriosb 701070 **4. A:4101*;;A:re;•• 4•04:411414;:1;•.:4471:4111—.1:711, ::•?:.1$241)90.0.41$4.111•4t4411 644)**1,114tow • 11144414 ob(SCHP14°SIZEiVC:AIPEA: MANIFOLD) P40.41i4"440441-0 • 411;10 111; tir04.411.4.411.6 SCH 40 PVC 45 BEND (TYP) SUPPLY OR RETURN MANIFOLD END MANIFOLD CLEANOUT NOT TO SCALE 12" x 12" x 4" #67 WASHED STONE oosiepoop•sh, eis s "?.49 et• • .etot 440,41;1000-° 0 u a) 0 E w 41 c to 0 41 G) tn 1— cu w 'EA LLJ 1'.. to) oi N. co o. co so a> 6)". 13 0 co c 1 >.' (7) z 2 E rt. co c E 0 cs, a) co c? C.: 0) LU CD 0 0 z o 0 re QQ 0 IAI z I 0 0 _j z U.: 8 a. 0 LU z < co 0 ui 0 0 2 Designed By: Drawn By: Checked By: TMB TMB BJK Scale: AS NOTED Date: REVISED 07/10/12 Project Number. 120147 111111111111111111011111111111M1M SHEET L--1' ALL AROUND — BACKFILL FREE OF DEBRIS (12" INCHES) VALVE BOX 12" FINISH GRADE o E— l/ 1" PVC COUPLING PVC MAINLINE FILTER AND FIELD FLUSH LINE 1" PVC COUPLING BRICK SUPPORTS (ONE AT EACH CORNER) 1 CU. FT. PEA GRAVEL SUMP IN FROM DOSING TANK b OUT TO SEPTIC TANK b VORTEX FILTER —'- FILTER FLUSH VALVE IPS FLEX PVC SCH 40 UNION--- SCH 4 VORTEX FILTER FILTER FLUSH VALVE IPS FLEX PVC — UNION 36" MINIMUM AIR VENT PRESSURE GAUGE FIELD FLUSH VALVE SECTION VIEW SCH 40 UNION 11 PRESSURE GAUGE AIR VENT \ FIELD FLUSH VALVE 4 ZONE HEADWORKS — AUTOMATIC NOT TO SCALE ODER/\TING �EGI vE The E—Z Treat treatment system is controlled by an Ohio simplex control panel which doses the filter media for 3 minutes every 16 minutes. Field dosing will be controlled with a E—Z Treat one —zone Controller. The Controller will activate the pump and associated contra) valves to dose the irrigation zones every 4.0 hours. If less than 600 gallons are available, the low level float will inactivate the pump. If the high water level "alarm " float is activated, the system will begin its operation of delivering the pre —determined dose volume and shall also energize the audible and flashing alarm fixtures. Once energized, the flashing and audible alarm units may only reset manually. When properly maintained and utilized, the E—Z Treat treatment system should meet the following effluent characteristics: CBOD5: TSS: Fecal Coliform: TN: 15 mg/L 15 mg/L 200 cfu/100 ml 50% Reduction Should the effluent fail to meet these expectations, contact the system operator, and E—Z Sst Company, Inc. immediately. ITEM FREQUENCY Septic Tanks 3-6 months PumpTank Septic Lines, Force Mains Distribution Fields 12 months weekly 3-6 months 12 months 6-12 months 2-4 weeks 3-6 months AI\TENA\ EXISTING GRADE IN FROM DRIP FIELD FOB DRIP IRRIGATION SYSTEM 0 0 24" MINIMUM FLOW METER ZONE VALVE The Controller will also control the periodic backwashing of the filters and flushing operation of the sub —field lateral network. Filter backwashing shall occur at the end of each dose cycle or by recognition of a pre—set elapsed time since last system flush. System lateral flushing shall occur when the microprocessor senses recognition of a pre—set elapsed time since last system flush (in this case, at least 50 cycles) and after a power outage. The system shall be configured to allow for manual initiation of backwashing filters or sub —field system flushing. For this system, the flushing time shall equal the zone dose time of approximately 8.3 minutes and shall occur every 8 days (1% of the pump run time in each zone). The controller may log and record, for later retrieval or transmission, the times of operating cycles, gallons dosed by zone, and any alarm condition. The main pump control panel shall include, but not be limited to an " auto / manual " system control switch, stop /start switch for each pump, and individual pump run lights. The main pump control panel shall be a NEMA 4x enclosure. All supporting control units, if not housed within the main pump control panel, shall be in a seperate NEMA 4x enclosure. CE SCHEDULE TASK Check for solids accumulation, blockages, baffle damage, in/exfiltration, and pump septage Pump out accumulated solids if necessary Check pumps, controls, alarms, and elapsed time meters Check for solids accumulation and in/exfiltration Pump out accumulated solids, if necessary Check for exposed pipe and leakage Mow vegetative cover if applicable Check for erosion and ponding of effluent quarterly semi—annually annually Remove filter covers and inspect for accumulation of debris. Check differential pressure gauge before and after filter flushing (D.P. should return to origional operating D.P.). Check pumps for abnormal vibration and test the alarm functions Remove and lubricate 0—rings on filter canister, replace if damaged, and clean filter at hydraulic tubing feed. Remove filter disc rings and replace, clean used rings in mild acid solution, and store for next annual replacement. Dig alongside dripperline ( one per field ) and remove small section with emitter, repair with " RAM " couplings and new tubing, and inspect removed tubing for excess slime buildup. Flush dripperlines with chemical solution as recommended by " Waste Water Systems, Inc. " as needed. b 0 - 013Ld dial 01 I 111 ..P 0 m r 0 1 NOTES: 1. ULTRAVIOLET LIGHT PURIFIER MODEL EZ-UV 1000 BY E-Z SET COMPANY. 2. PROVIDE DUAL GFI RECEPTACLE FOR UNIT AND HEAT TAPE. FIELD ROUTE 2-# 12,1-# 12G,#N 3/4" PVC CONDUIT TO 20 VOLT SINGLE PHASE 20 AMP BREAKER AT HOUSE. 3. ORIENTATION PER SITE REQUIREMENTS. 4. INSTALL 1 /2" BALL VALVE FOR SAMPLING DOWNSTREAM OF U.V. UNIT. 5. PROVIDE MIN. 5' OF 2" SCH. 40 PVC ON INLET AND OUTLET U.V. UNIT. 2" x 1-1/4" REDUCER 4" CONCRE I E SLAB WIRING HARNESS ATTACHMENT TO LAMPS -� TOP VIEW FLOW DIVERSION PLATE c \\ \ \\ \\ \\ \\ 1/4 \\& \2 `�\�\\1 b 2" x 1-1/4" REDUCER //>//j�\`�'/jam//i`f`� //s. , /,</k 30" DIA. E—Z SET RISER PRIMARY LAMP 48" 1/2" BALL VALVE —\ War 111 DISCONNECT UNION (TYP.) 2" 1-1/4" x 1-1/4" REDUCER --- CONTROL WITH ALARM 6" MIN. 35" RISER CAST INTO SLAB -2"x2"x1/2" REDUCING TEE DISCONNECT UNION (TYP.) 100% BACKUP LAMP 4 A 4• ICTIO V=W UV WASTEWATER DISINFECTION UNIT NOT TO SCALE /4 2" x 1-1/4" REDUCER 3000PSI POURED CONCRETE PAD WITH FIBERMESH (4'x4' MIN. x 6" THICK) APPROVED Not th Carolina Environmental M.enagement Commission Division of Water Quality Date ( 3 a— 20 Perr,t# 2% •.• ac ♦ qN oPy *'enti111ua0`,� 1_, t3 .;0/ >m• c R5 a, 0 u a) a 1.4 co E w 0ct cit CO 0- 0 v t- cn tij s a) w Ph: 919.577.1080 Fax: 919.577.1081 E U a) NCBELS Firm No. C-2378 0 z < 0 LL Q fi W0 � z J z U--�0 C9 < W = 0� ZQ <[_ o CO W 0 Tz 00 2 Designed By: TMB rawn By TM Checked By: BJK Scale: AS NOTED Date: REVISED 07/10/12 Project Number 120147 SHEET 6 OF 7 HUNTER RAIN SENSOR MODEL: MINI—CLIK—HV LIQUID—TITE CONDUIT WEATHER—PROOF CONNECTOR ATTACH DIRECTLY TO CONTROL PANEL — — — HUNTER MINI—CLIK—HV RAIN SENSOR NOT TO SCALE / / / ATTACH LEADS TO TERMINALS X1 AND X2 IN THE CONTROL PANEL ELECTRICAL NOTES 1. TWO DIFFERENT PANELS SHALL CONTROL THE IRRIGATION SYSI LM AT CHRISTIAN CHAPEL CHURCH RD. ONE WILL CONTROL PRETREATMENT AND ONE SHALL CONTROL FINAL DISPOSAL. 2. EACH PANEL SHALL BE APPROXIMATELY 12 INCHES WIDE X 14 INCHES HIGH AND SHALL BE NEMA 4X, UL RATED ENCLOSURE. THE PANELS SHALL BE SUPPLIED TO THE BUILDER BY THE SYSTEM DISTRIBUTOR. 3. PANELS SHALL BE MOUNTED BY THE ELECTRICIAN AS CLOSE TO THE TANKS AS POS.IBLE, IN THE APPROXIMATE AREAS AS SHOWN ON THE PLANS AT A MINIMUM HEIGHT OF 24 INCHES ABOVE FINISHED GRADE. 4. THE BUILDER'S ELECTRICIAN SHALL MAKE THE INTERNAL PANEL CONNECTIONS OF THE PUMP AND CONTROL CORDS. EACH CONTROL PANEL SHALL CONTAIN A WIRING SCHEMATIC IDENTIFYING ALL TERMINAL CONNECTIONS. THE SYSTEM INSTALLER SHALL BUNDLE AND MARK EACH CORD WITH THE APPROPRIATE IDENTIFICATION AND SECURE IN THE ACCESS RISER AT THE VARIOUS PUMP POINTS. 5. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 2.30 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 6. THE PRETREATMENT CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 10 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM/CONTROL SIDE OF THE PANEL. 7. THE FINAL DISPOSAL CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 20 AMPS, 230 VOLTS, SINGLE PHASE SUPPLIED FOR THE PUMP. 8. THE FINAL DISPOSAL CONTROL PANEL REQUIRES A DEDICATED CIRCUIT OF 10 AMPS, 115 VOLTS SUPPLIED FOR THE ALARM/CONTROL SIDE OF THE PANEL. 9. A MINIMUM CONDUIT SIZE OF 1i INCH SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICIAN AS A CONNECTION BETWEEN EACH CONTROL PANEL AND THEIR RESPECTIVE TERMINATION POINTS IN THE TANK AREA. 10. ALL OPEN CONDUIT ENDS SHALL HAVE REMOVABLE CLAY —TYPE DUCT SEAL EMBEDDED IN ORDER TO PREVENT GASES AND MOISTURE FROM ENTERING THE CONTROL PANELS. DO NOT USE PERMANENT SILICONE OR EXPANDABLE FOAM PRODUCTS. 11. ALL PUMP AND FLOAT CONTROL CORDS SHALL BE SUPPLIED WITH EITHER 30 FT. OR 50 FT. LEADS. THIS WILL HELP KEEP SPLICES TO A MINIMUM, WHICH AND SHOULD BE AVOIDED IF POSSIBLE. IF A SPLICE MUST BE MADE, IT MUST BE MADE ABOVE GRADE IN A NEMA 4X JUNCTION BOX. NO SPLICES SHALL BE MADE IN ANY TANK. 12. ALARMS SHALL BE AUDIBLE AND VISUAL. ALARMS SHALL ACTIVATE THE WIRELESS AUTO DIALER 13. ELECTRICIAN SHALL VERIFY EQUIPMENT REQUIREMENTS PRIOR TO INSTALLATION. NOTE: 1) SEE ATTACHED SPECIFICATION SHEETS FOR PANEL DETAILS 2) THE CONTROL PANEL ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. 3) PANELS BUILT FOR E—Z SET COMPANY BY: rHIO ELECTRIC CONTROL, INC. oEc 2395 ROCK ROAD Ashland, Ohio 44805 0040111110 VOLTAGE; 115/23QV PUMP 114/2 2M-TV LI �►---�i i �n a---- rm zwiErnitiorr mum. afflismo wt>r sncsm I f -. •i •�li® 1' .AUTO ILIV-1/4 5111 URA IliFLA faliimLIMUTOR HURT IOW OME�MO PRERE1CTIIJN I 1.4 SR ti 12 0 +9WWIRT REMOTE ALARM 0 M 7 i male Yr01U lL1E7i AND SPSIEM EL191 'M&WS WITT ■E 14011110117 CLOSED • iY.0 i•.ere iri'V O 0, Y u t?.4-u.i1��,iOn XX= Mill= ■ ■ ■ mom rime min pay gragarii PHASE: 1 HERTZ: 50 HP:1/3 FLJk16 ENCLOSURE TYPE: 4X SHORT CIRCUIT CURRENT: 5KA RMS SYMMETRICAL 24W MANOLIUM E-Z SET 1700 DAVITS mum ROCK! KODN'r. NC 27003 TITLE; PAGES: SHED I OF DATE: 10-08 REV. DATE CONTROL PANEL WIRING SCHEMATIC CT\ E-Z TREAT DRIP CONTROL PANEL NOT TO SCALE DWG: EZ1—SIM—ALIT 10 (o (m) GROUND CB1 0 ° 0 Q 1u u M1 BLWER OCK 0 r � (r�fFIJSES yl 0 0 PUMP 1 =000 (O (0) GROUND ROT PUMP RUN a) MN L a 8 OFF AUTO ALARM 8 OFF TEST LS2 Het LEVEL LEI ww ems. ENCLOSURE 14X12 SONALERT NOTE: 1) SEE ATTACHED SPECIFICATION SHEETS FOR PANEL DETAILS 2) THE CONTROL PANEL ALARMS SHALL BE EXTERNAL TO ANY STRUCTURE. 3) PANELS BUILT FOR E—Z SET COMPANY BY: HIO ELECTRIC CONTROL, INC. VLF✓ 2395 ROCK ROAD Ashland, Ohio 44805 J 13i MEM mtnYs =LER my IL O.o xfi ' FRENN TERMINAL XZ �--FRINII TEMPI& XI - NOTES: 1. 230V-10 OPERA —MN USE T1 AND T2 TO PUMP. 2. 115V-10 OPERATION USE T1 AND N TO PUMP. 3. MAX. HP FOR 115V-10. PUMP 1HP. 4. MAX. HP FOR 230V-10 PUMP 2 HP. VOLTAGE HP/FLA: 11SV�123tit+ 00 2/12 � TYPE: 4X PHASE. 1 SHORT CIRCUIT cUl ENT: SOCA l S snAkenRICAL 240V MAXIMUM E—Z SET 1700 DAVIS STREET ROCKY MOUNT. NC 27803 TITLE RECIRCULATION PUMP PAGES: SHEEP _ OP 10-08: - REV DATE CONTROL PANEL WIRING SCHEMATIC Des., NO.: RCS1220E E—Z TREAT PRETREATMENT CONTROL PANEL NOT TO SCALE APPROVED Noah Carolina Environmental Management Commission Division of Water Quality Date c724 2---, fe Permit # (O 6—(5D 3S ) 141444441/11444 CARD( '" pro t c>i* co E t V ail► ern Li) tiJ co elma 03 ua ai 0) ra LL 0 co of rn .^C CNI 0 Z rn 0. (Pi 5 j5 c 0 Z a CV 8 5 0 c as E N m .0 O c 0 z < a 0 rt U -'"0i-- Lu ce 0 0 0 J z LC ILI 8 U 1 dd�^W V 2 0 0 r*ed By: TM NCBELS Firm No. C-2378 Drawn By: TMB Checked By: BJK Scale: AS NOTED Date: REVISED 07/10/12 Project Number. 120147 SHEET 7 OF 7 Permittee: Samuel F. Cherry, Jennifer D. Cherry (i.e., all deeded property owners) The Permittee agrees to operate and maintain the single-family residence wastewater treatment and irrigation system as follows: 1. Inspect the septic tank annually, and pump out solids as needed. 2. Inspect and clean the septic tank effluent filter annually. (Li applicable) 3. Inspect the tablet chlorinator weekly. Add wastewater grade chlorine tablets (e.g., calcium hypochlorite) as needed. Swimming pool grade chlorine tablets are not acceptable. (if applicable) 4. Inspect the ultraviolet disinfection unit weekly. Clean or replace the lamps and quartz sleeves as needed. (if applicable) 5. Inspect all storage tanks, pumps, and alarms monthly. Remove the floating scum layer in all pump/storage tanks when pumping the septic tank solids out. 6. Inspect the spray irrigation system monthly to verify: proper operation of the spray heads; that there are no leaks; that vegetative growth does not obstruct the spray heads: that the irrigated wastewater is not ponding in or - running off the designated irrigation area: and that there are no objectionable odors. (if applicable) 7. Inspect the drip irrigation system monthly to verify: proper operation of the drip lines; that there are no leaks; that vegetative growth does not obstruct the drip emitters: that the irrigated wastewater is not ponding in or running off the designated irrigation area; and that there are no objectionable odors. (if applicable) 8. Maintain a set of Division-approved engineering plans and specifications. 9. Pay the required annual fee. 10. Request renewal of this permit on Division-approved forms no later than 180 days prior to expiration. 11. Sign and provide a Change of Ownership application to any future owner of the single-family residence wastewater treatment and irrigation system for their completion and submission to the Division of Water Resources. I-We understand the above requirements and agree to these terms as part of the issued permit. _ -�� tI Ak 2.ot2_ Signature: Date: 1 / b Z Signature: �' �'Y.--''��...., 1��--�^-^--�, Date: c,. Signature: Date: Signature: Date: All deeded property owners shall sign this Operation and Maintenance Agreement ATTACHMENT G—CIVIL PENALTIES AND OUTSTANDING VIOLATIONS Does the Permittee have any existing civil penalties or outstanding violations'? ❑❑ Yes(civil penalties)—Submit payment for the civil penalty,or proof of remission request. ❑❑ Yes (violations)—Submit a copy of your response to the Notice of Violation. ❑❑ N'o—Skip Attachment G. ATTACHMENT H—SETBACK WAIVERS Does the existing permit include setback waivers'? ❑❑ Yes—Pursuant to 15A NCAC 02T .0606(c).provide setbacks waivers that have been written, notarized,signed by all parties involved, and recorded with the county Register of Deeds. Waivers inolying the compliance boundary shall be in accordance with 15A NCAC 02L .0107. ®❑ No—Skip Attachment H. APPLICANT'S CERTIFICATION I J Caw tt�C,. ' f attest that this application (Signature authority's name as noted in Section 1. Item 3) has been reviewed by me and is accurate and complete to the best of mr know ledge. I understand that if all required parts of this application package are not completed, and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. I further certify pursuant to 15A NCAC 02T .0120(b), that the applicant, or any parent, subsidiary. or other affiliate of the applicant has: not been convicted of environmental crimes under: not previously abandoned a wastewater treatment facility without properly closing the facility; not paid a civil penalty: not been compliant with any compliance schedule in a permit. settlement agreement,or order: not paid an annual fee. Note: The Applicant's Certification shall be signed pursuant to l5A NCAC 02T .0106(b). An alternate person may be delegated Os the signing official if a letter is provided pursuant to 15A NCAC 02T .0106(c). Pursuant to § 143-215.6A and § 143-215.6B. any person who knowingly makes any false statement, representation.or certification in any application package shall be guilty of a Class 2 misdemeagot;whit may include a fine not to exceed S10.000 as well as civil penalties up to S25.000 per violation. Signature: . ...0 Date: .3" 25 THE COMPLETED APPLICATION AND ATTACHMENTS SHALL BE SUBMITTED AS A SINGLE PDF FILE VIA: Email: Laserfiche Upload: ton-Discharge.Reports(fncdenr.gov https:'/edocs.deq.nc.gov/Forms/NonDischarge-Branch- Submittal-Form-Ver2 FORM: SFRWWIS-R 02-21 Page 4 of 4 ATTACHMENT A—SITE MAP \Vas the facility originally pemmitted or had a major modification issued after September 1,2006? ®❑ Yes—Pursuant to 15A NCAC 02T .0105(d). submit a site map pursuant to the requirements in 15A NCAC 02T .0604(d). These requirements are: ❑ A scaled map of the site with topographic contour inters als not exceeding 10 feet or 25 percent of total site relief and showing all facility-related structures and fences within the wastess ater treatment.storage, and irrigation areas. ❑ Soil mapping units shown on all irrigation sites. ❑ The location of all wells (including usage and construction details if available), streams (ephemeral, intermittent, and perennial). springs, lakes, ponds, and other surface drainage features within 500 feet of all wastewater treatment, storage, and irrigation sites. ❑ Delineation of the compliance and review boundaries per 15A NCAC 02L .0107 and.0108,and 15A NCAC 02T .0601. ❑ Setbacks as required by 15A NCAC 02T .0606. ❑ Site property boundaries within 500 feet of all wastewater treatment, storage, and irrigation sites. ❑ All habitable residences or places of public assembly within 500 feet of all treatment, storage,and irrigation sites. ❑❑No—Skip Attachment A. ATTACHMENT B—SIGNATURE AUTHORITY DELEGATION Does the signature authority in Section I,Item 3 meet the requirements pursuant to 15A NCAC 02T .0106(b)? ❑ ®❑Yes—Skip Attachment B. ❑No—Submit a delegation letter pursuant to 15A NCAC 02T .0106(c) authorizing the signature authority to sign. ATTACHMENT C—FLOW REDUCTION Does the existing permit include an approved flow reduction? ❑❑ Yes—Submit a copy of the flow reduction approval letter. as well as the measured monthly average amount of wastewater floss contributed per unit for the 12 months prior to permit renewal If any of these monthly averages are within 20% of the approved flow reduction value, the Permittee shall provide a reevaluation of the reduced flow value pursuant to the requirements in 15A NCAC 02T.0114(1). ®❑ No—Skip Attachment C. ATTACHMENT D—EASEMENT,ENCROACHMENT,AND LEASE AGREEMENTS Does the Permittee own all of the land associated with the wastewater collection, treatment,conveyance,and irrigation system? ®❑ Yes—Skip Attachment D. ❑❑ No — Pursuant to l5A NCAC 02T .0116(e). provide a copy of all casements, lease agreements, and encroachment agreements allowing the Permittee to operate and maintain the waste\\ater collection, treatment, conveyance, and irrigation system on property not owned by the Permittee. ATTACHMENT E—AFFILIATIONS Are the Pennittee's affiliations of record correct? Check affiliations. ®❑ Yes—Skip Attachment E. ❑❑ No—Provide the corrected affiliations and their contact information. ATTACHMENT F—COMPLIANCE SCHEDULES Does the existing permit include any Compliance Schedules? (See Section I of the most recently issued permit) ®❑ Yes—Submit documentation that the compliance schedules has e been met. ❑❑ No—Skip Attachment F. FORM: SFRWWIS-R 02-21 Page 3 of 4 State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02T .0600—SINGLE:-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEM—RENEWAL FORM: SFRWWIS-R 02-21 Pursuant to 15A NCAC 02T .0107 1 , if the application does not include all required information and the necessary supporting documentation, the application shall be returned. The application and attachments shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .0600, and Division Policies. For more information, visit the Water Quality Permitting Section's Non-Discharge Branch website. The Applicant shall submit an electronic copy of the application and attachments uploaded as a single Portable Document Format(PDF) tile to https://edocs.deq.nc.gov/Forms/NonDischarge- Branch-Submittal-Form-Vert,or emailed to Non-Discharge.Reportsrancdenr.gov if less than 20 megabytes(MB). SECTION I—APPLICANT INFORMATION 1. Applicant: Samuel Franklin Cherry 2. Permit No.:WQ0035929 3. Signature authority: Samuel Franklin Cherry Title: Land Owner 4. Mailing address: 226 Seastonc Street City: Raleigh State: NC Zip: 27603- 5. Contact person: Mr. Sam Cherry Email: net erenoughgunsgmail.com Primary phone number: (919) 7-0 Select Secondary phone number: (919)427-9494 Select 6. Secondary Contact person: Jen Cherry Email:jencherry2 crgmail.com Primary phone number: (919) 796.-9123 Select Secondary phone number: ( ) - Select SECTION II FACILITY INFORMATION 1. Physical address: 3529 Christian Chapel Church Road County: Chatham City: Moncure State: NC Zip: 27559- SECTION III-BILLING INFORMATION 1. Billing address: 226 Seastone St City: Raleigh State: NC Zip: 27603- 2. Verify the Applicant does not have any overdue annual fees: https: deq.nc.got about divisions water-resources water-resources-permits tyq-epayments Pursuant to 15A NCAC 02T .0120(c),permits for renewing facilities shall not be granted if the Applicant or any affiliation has an unpaid annual fee. FORM: SFRW\\IS-R 02-21 Page 1 of 4