Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG500657_Permit (Issuance)_20110916
ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary September 16, 2011 Duke Energy Carolinas, LLC Attention: Allen Stowe 526 South Church Street, Interoffice — EC13K Charlotte, NC 28202 Subject: Certificate of Coverage NCG500657 General Permit NCG500000 Duke Energy Carolinas, LLC Franklin Hydroelectric Station Macon County Dear Mr. Stowe: In accordance with your application for discharge, the Division is forwarding herewith the subject Certificate of Coverage to discharge under the subject state-NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated July 17, 2007 (or as subsequently amended). The following information is included with your permit package: • A copy of the Certificate of Coverage for your treatment facility • A copy of General Wastewater Discharge Permit NCG500000 • A copy of a Technical Bulletin for General Wastewater Discharge Permit NCG500000 If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Guerra at telephone number 919/807-6387 or by email at bob.querra(ncdenr.gov. Sincerely, Coleen H. Sullins cc: Asheville Regional Office, Surface Water Protection NPDES General Permit Files Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63871 FAX: 919-807-64951 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer NorthCarolina Naturally Permit NCG500657 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY Certificate of Coverage NCG500657 General Permit NCG500000 TO DISCHARGE NON -CONTACT COOLING WATER, COOLING TOWER AND BOILER BLOWDOWN, CONDENSATE, EXEMPT STORMWATER, COOLING WATERS ASSOCIATED WITH HYDROELECTRIC OPERATIONS, AND SIMILAR WASTEWATERS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Duke Energy Carolinas, LLC is hereby authorized to discharge wastewater from a facility located at the Franklin Hydroelectric Station Macon County to the Little Tennessee River, a class C water in the Little Tennessee River Basin in accordance with effluent limitations, monitoring requirements and other conditions set forth in Parts I, II, III and IV of the General Permit NCG 500000, as attached. This permit shall become effective September 16, 2011. This Certificate of Coverage shall expire at midnight on July 31, 2012. Signed this day September 16, 2011. Fir feen H. Sullins., Director Division of Water Quality By Authority of the Environmental Management Commission Outfall 001 Duke Energy Corporation Franklin Hydroelectric Project WWTP Latitude: 35° 13' 1.1" N State Grid: Corbin Knob Longitude: 83°22' 15" W Permitted Flow: N/A Receiving Stream: Little Tennessee Drainage Basin: Little Tennessee River Stream Class: C Sub -Basin: 04-04-01 Facility Location not to scale AAR" NPDES Permit No. NCG500657 Macon County Date: August 31, 2011 NPDES STAFF REPORT AND RECOMMENDATIONS County Macon NPDES Permit No. NCG500657 PART I - GENERAL INFORMATION 1. Facility and Address: Franklin Hydroelectric Project Duke Energy Corporation Mail Code EC13K PO Box 1006 Charlotte, NC 28201-1006 2. Date of Investigation: June 15, 2011 3. Report Prepared By: Jeff Menzel 4. Persons Contacted and Telephone Number: Allen Stowe (704) 382-4309 5. Directions to Site: Slight right onto US-74 W/Great Smoky Mountains Expy (signs for US- 19/US-23/Clyde/Waynesville/Maggie Valley/Franklin/Murphy/Atlanta) Turn right onto Lake Emory Rd, Take the 1st right onto Jim Berry Rd Slight left onto Clyde Downs Rd 6. Discharge Point - Latitude: 35 13' 10.92"N Longitude: 83 22' 14.94"W Attached a USGS Map Extract and indicate treatment plant site and discharge point on map. USGS Quad No. 35083b3 or USGS Quad Name Corbin Knob 7. Size (land available for expansion and upgrading): N/A 8. Topography (relationship to flood plain included): Hydro dam located at the end of Lake Emory 9. Location of nearest dwelling: 68 Meters 10. Receiving stream or affected surface waters: Little Tennessee a. Classifications: "C" b. River Basin and Subbasin No.: 04-04-01 c. Describe receiving stream features and pertinent downstream uses: Little Tennessee provides habitat for the C:1Documents and Settings\Bob_GuerralLocal Settings\Temporary Internet Files\Content.Outlook\EE7F8SL11Franklin Hydro Staff Report.docx propagation of wildlife and opportunities for recreational activities PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. Type of wastewater: 100% Industrial a. Volume of Wastewater: MGD b. Types and quantities of industrial wastewater: non -contact cooling water c. Prevalent toxic constituents in wastewater: N/A d. Pretreatment Program (POTWs only) in development approved should be required not needed X 2. Production rates (industrial discharges only) in pounds N/A a. highest month in the last 12 months b. highest year in last 5 years 3. Description of industrial process (for industries only). The Franklin Project is located in Macon County, North Carolina, on the Little Tennessee River near the town of Franklin. The Project consists of a concrete gravity dam approximately 36-feet high and 460-feet long, a powerhouse containing two generating units with a total installed capacity of 1.04 MW, related electric power production components and facilities; and a reservoir approximately 4.6 miles in length. The Project has limited storage and no change to the facilities or operation of the Project is being requested. 4. Type of treatment (specify whether proposed or existing): N/A 5. Sludge handling and disposal scheme: N/A 6. Treatment plant classification: C:\Documents and Settings\Bob_GuerralLocal Settings\Temporary Internet Files\Content.OutlooklEE7F8SL11Franklin Hydro Staff Report.docx PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grants Funds (municipals only)? N/A 2. Special monitoring requests: None 3. Additional effluent limits requests: 4. Other: PART IV - EVALUATION AND RECOMMENDATIONS The Asheville Regional Office recommends issuance of NPDES Permit Number NCG5 to Duke Energy Carolinas Franklin Hydro Project. Signature of Report Preparer Water Quality Regional Supervisor C:\Documents and Settings\Bob_Guerra\Local Settings\Temporary Internet Files\Content.Outlook\EE7F8SL11Franklin Hydro Staff Report.docx MkDuke Energy® July 15, 2011 Mr. Robert Guerra State of North Carolina Department of Environment and Natural Resources Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: Duke Energy Carolinas, LLC — NPDES Permit Application Renewal of NPDES General Permit - #NCG500000 Franklin Hydroelectric Plant Dear Mr. Guerra: CORPORATE EHS SERVICES Duke Energy 526 South Church St. Charlotte, NC 28202 Mailing Address: EC13K / PO Box 1006 Charlotte, NC 28201-1006 Please find enclosed in triplicate, the amended Notice of Renewal Intent for the Franklin hydroelectric facility. Also included is a check (#1000062670) in the amount of $100.00. Duke Energy Carolinas, LLC requests notification that this application is complete. Thank you in advance for your assistance on this matter. Should you have questions regarding this application, please contact me at (704) 382-4309. Sincerely, Allen Stowe Water Management Attachments cc w/: Mr. Keith Haynes — NC DENR Asheville R.O. www.duke-energy.com AfrA NCDENR •10MrH CO CIIM Cti%M71..[q/1 V>' rHVnCCvVrvr aft, N,11:14 Rr•„s,xrf� Division of Water Quality / Water Quality Section National Pollutant Discharge Elimination System /ao NCG500000 FOR AGENCY USE ONLY Date Received Year Month Day Ad it 07 / Q Certificate of Coverage NICIGIS 4517 rol Check it Amount t'a RG 7 a /[%O.Oc) Permit Assigned to Qn/ Cuter NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG500000: Non -contact cooling water, boiler blowdown, cooling tower blowdown, condensate, and similar point source discharges (Please print or type) 1) Mailing address' of owner/operator: Company Name Owner Name Street Address City Telephone No. Duke Energy Carolinas, LLC Allen Stowe - Water Management 526 South Church Street, Interoffice - EC13K Charlotte (704) 382-4309 * Address to which all permit correspondence will be mailed 2) Location of facility producing discharge: Facility Name Facility Contact Street Address City County Telephone No. Franklin Hydroelectric Station State N.C. Fax: (704) ZIP Code 28202 382-1681 Gary Morgan 564 Clyde Downs Road Franklin Macon State N.C. ZIP Code 28734 828 369-4605 Fax: N/A 3) Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). Take Highway 74 to Exit 81. Travel Highway 23/441 to Franklin, turn right on Clyde Downs Road, Franklin Hydro will be on the left approximately 0.3 miles down Clyde Downs Road. (A copy of a county map or USGS quad sheet with facility clearly located on the map is required to be submitted with this application) 4) This NPDES permit application applies to which of the following : IR New or Proposed ❑ Modification Please describe the modification: ❑ Renewal Please specify existing permit number and original issue date: 5) Does this facility have any other NPDES permits? .cM©E}duD JUL 1 9 2011 • . - w •t POINT SOURCE BRANCH IR No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 6) What is the nature of the business applying for this permit? Electric Generation Page 1 of 4 04/05 NCG500000 N.O.I. 7) Description of Discharge: a) Is the discharge directly to the receiving water? 8 Yes ❑ No If no, submit a site map with the pathway to the potential receiving waters clearly marked. This includes tracing the pathway of the storm sewer to the discharge point, if the storm sewer is the only viable means of discharge. b) Number of discharge points (ditches, pipes, channels, etc. that convey wastewater from the property): 1 c) What type of wastewater is discharged? Indicate which discharge points, if more than one. 8 Non -contact cooling water Discharge point(s) #: 001 ❑ Boiler Blowdown Discharge point(s) #: ❑ Cooling Tower Blowdown Discharge point(s) #: ❑ Condensate Discharge point(s) #: ❑ Other Discharge point(s) #: (Please describe "Other") d) Volume of discharge per each discharge point (in GPD): #1: 4.74E +8 #2: #3: #4 e) Please describe the type of process (i.e., compressor, NC unit, chiller, boiler, etc.) the wastewater is being discharged from, per each separate discharge point (if applicable, use separate sheet): Hydroelectric generator 8) Please check the type of chemical added to the wastewater for treatment , per each separate discharge point (if applicable, use separate sheet): ❑ Biocides Name: Manuf.: ❑ Corrosion inhibitors Name: Manuf.: ❑ Chlorine Name: Manuf.: ❑ Algaecide Name: Manuf.: ❑ Other Name: Manuf.: B None 9) If any box in item (8) above, other than none, was checked, a completed Biocide 101 Form and manufacturers' information on the additive is required to be submitted with the application for the Division's review. 10) Is there any type of treatment being provided to the wastewater before discharge (i.e., retention ponds, settling ponds, etc.)? ❑ Yes B No If yes, please include design specifics (i.e., design volume, retention time, surface area, etc.) with submittal package. Existing treatment facilities should be described in detail. Design criteria and operational data (including calculations) should be provided to ensure that the facility can comply with the requirements of the General Permit. The treatment shall be sufficient to meet the limits set by the general permits. Note: Construction of any wastewater treatment facilities requires submission of three (3) sets of plans and specifications along with the application. Design of treatment facilities must comply with the requirements of 15A NCAC 2H .0138. If construction applies to this discharge, include the three sets of plans and specifications with this application. Page 2 of 4 04/05 NCG500000 N.O.I. 11) Discharge Frequency: a) The discharge is: B Continuous 0 Intermittent 0 Seasonalo i) If the discharge is intermittent, describe when the discharge will occur: NIA ii) If seasonal check the month(s) the discharge occurs: 0 Jan. 0 Feb. 0 Mar. 0 Apr. 0 May 0 Jun. 0 Jul. 0 Aug. ❑ Sept. 0 Oct. 0 Nov. 0 Dec. b) How many days per week is there a discharge? 7 c) Please check the days discharge occurs: 8 Sat. 8 Sun. B Mon. 8 Tue. 8 Wed. B Thu. 8 Fri. 12) Pollutants: Please list any known pollutants that are present in the discharge, per each separate discharge point (if applicable, use separate sheet): 13) Receiving waters: a) What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility wastewater discharges end up in? If the site wastewater discharges to a separate storm sewer system (4S), name the operator of the 4S (e.g. City of Raleigh). Little Tennessee River b) Stream Classification: Class C 14) Alternatives to Direct Discharge: Address the feasibility of implementing each of the following non -discharge alternatives a) Connection to a Municipal or Regional Sewer Collection System Not Available b) Subsurface disposal (including nitrification field, infiltration gallery, injection wells, etc.) Too much flow c) Spray irrigation Not justifiable, no significant thermal gradient or pollutant load The alternatives to discharge analysis should include boring logs and/or other information indicating that a subsurface system is neither feasible nor practical as well as written confirmation indicating that connection to a POTW is not an option. It should also include a present value of costs analysis as outlined in the Division's "Guidance For the Evaluation of Wastewater Disposal Alternatives'. 15) Additional Application Requirements: For new or proposed discharges, the following information must be included in triplicate with this application or it will be returned as incomplete. a) 7.5 minute series USGS topographic map (or a photocopied portion thereof) with discharge location clearly indicated. b) Site map, if the discharge is not directly to a stream, the pathway to the receiving stream must be clearly indicated. This includes tracing the pathway of a storm sewer to its discharge point. c) If this application is being submitted by a consulting engineer (or engineering firm), include documentation from the applicant showing that the engineer (Or firm) submitting the application has been designated an authorized Representative of the applicant. d) Final plans for the treatment system (if applicable). The plans must be signed and sealed by a North Carolina registered Professional Engineer and stamped "Final Design -Not released for construction". Page 3 of 4 04/05 NCG500000 N.D.I. e) Final specifications for all major treatment components (if applicable). The specifications must be signed and sealed by a North Carolina registered Professional Engineer and shall include a narrative description of the treatment system to be constructed. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Carol S.Goolsby Title: Vice President, Hydro Fleet 7//5/....24:)// (Signature of Applic t) (Date Signed) North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Mail three (3) copies of the entire package to: NPDES Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Final Checklist This application will be returned as incomplete unless all of the following items have been included: B Check for $100 made payable to NCDENR 8 3 copies of county map or USGS quad sheet with location of facility clearly marked on map 8 3 copies of this completed application and all supporting documents ❑ 3 sets of plans and specifications signed and sealed by a North Carolina P.E. B Thorough responses to items 1-7 on this application B Alternatives analysis including present value of costs for all alternatives Note The submission of this document does not guarantee the issuance of an NPDES permit Page 4 of 4 04/05 {t atau+Ia Discharge Location: 001 35°13'11" N 83°22'14.75" W NOTE' 1) USGS 7.5 Minute Series Topographic Quadrangles: Corbin Knob and Franklin (NC) [Source: ftp•J/ftp.nconemap.com/outgoing/raster/drg/) Drawn By: Chad Hearn Project Manager: Bill Miller Client: Duke Energy Date: 06/23/2011 SCALE 0 500 1.000 2,000 Feet DISCHARGE LOCATION MAP NPDES General Permit NCG500000 NOI DUKE ENERGY FRANKLIN HYDRO STATION MACON COUNTY, NORTH CAROLINA 35°12'30" N FIGURE 1 f