Loading...
HomeMy WebLinkAboutNCG500635_Permit (Issuance)_20061122V\I A 7-F9 p© A („,;.:DLIUCk NCDENR p Robert L. Greene INGENCO Wholesale Power, LLC 2250 Dabney Road Richmond, VA 23060 Dear Ms. Greene: Michael F. Easley Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality November 22, 2006 Subject: General Permit No. NCG500000 Certificate of Coverage NCG500635 INGENCO Wholesale Power, LLC Craven County In accordance with your application for discharge, the Division is forwarding herewith the subject Certificate of Coverage to discharge under the subject state-NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated May 9, 1994 (or as subsequently amended). The following information is included with your permit package: • A copy of the Certificate of Coverage for your treatment facility • A copy of General Cooling Water Discharge Permit NCG500000 • A copy of a Technical Bulletin for General Cooling Water Discharge Permit NCG500000 If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. Please provide rip rap or other protection at the point of discharge to prevent erosion. If you have any questions concerning this permit, please contact Sergei Chemikov at telephone number 919/733- 5083, extension 594. cc: Central Files NPDES General Permit Files Washington Regional Office, Water Quality N. C. Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 Internet: h2o.enr.state.nc.us Alan Klimek, P.E. Phone: (919) 733-5083 fax: (919) 733-0719 DENR Customer Service Center: 1 800 623-7748 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG500000 CERTIFICATE OF COVERAGE No. NCG500635 TO DISCHARGE NON -CONTACT COOLING WATER, COOLING TOWER AND BOILER BLOWDOWN, CONDENSATE AND SIMILAR WASTEWATERS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, INGENCO Wholesale Power, LLC is hereby authorized to discharge non -contact cooling water from a facility located at INGENCO Wholesale Power, LLC 7500 Old US Highway 70 New Bern, North Carolina Craven County to receiving waters designated as unnamed tributary to Batchelor's Creek, a Class C SW NSW waters in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage shall become effective November 22, 2006. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day November 22, 2006. Alan Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission TopoZone - USGS Jasper (NC) Topo Map Page 1 of 1 `--Discharge +okoil# tour r . 0 1 2 3 4 5 km 0 1 2 3 4 5 mi UTM 18 295682E 3894920N (NAD27) USGS Jasper (NC) Quadrangle Projection is UTM Zone 18 NAD83 Datum M* M=-9.678 G=-1.293 http://www.topozone.com/print.asp?lat=35.17827&lon=-77.24369&s=250&size=1&u=4&layer=DRG250... 9/1/2006 To: NPDES Permitting Unit Surface Water Protection Section Attention: Sergei Chemikov, Ph.D. Date: 11/13/06 NPDES STAFF REPORT AND RECOMMENDATION County: Craven Permit No. COC#NCG500635. PART I - GENERAL INFORMATION 1. Facility and Address: Facility: INGENCO Wholesale Power, LLC 7500 Old US Highway 70 West New Bern, NC 28562 Mailing: INGENCO c/o Mr. Robert L. Greene 2250 Dabney Road Richmond, VA 23060 2. Date of Investigation: 9/8/06 (A regular stormwater inspection was conducted at the Craven Landfill where this facility is located. The fuel facility was observed at that time.) 3. Report Prepared by: Pat Durrett 4. Persons Contacted and Telephone Number: Robert L. Greene (804)521-3500 ext:3557 5. Directions to Site: From Kinston take US 70 East approximately 22.7 miles to the Tuscarora Rhems Road ramp. Turn left at the top of the ramp and proceed north on the Tuscarora Rhems Road approximately 1 mile to Old US 70 West. Turn left onto Old US 70 West and proceed for approximately 1 mile t the entrance of the Craven County Landfill on the right. 6. Discharge Point, List for all discharge points: Latitude: Longitude: U.S.G.S. Quad No: U.S.G.S. Quad Name: Jasper, NC 7. Topography (relationship to flood plain included): This site is approximately 50-55 feet AMSL, with elevations increasing over landfill cells. 8. Location of nearest dwelling: Approximately. 9. Receiving stream or affected surface waters: UT to Batchelor's Creek a. Classification: Class "C" "Sw" "NSW" Waters in the Neuse River Basin b. River Basin and Subbasin No.: Neuse NEU 03 04 08 c. Describe receiving stream features and pertinent downstream uses: This is a tributary that collects stormwater runoff from silvaculture land. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted: .00576 MGD b. What is the current permitted flow limit? N/A MGD, .Note: c. Actual treatment capacity of the current facility? N/A MGD is listed d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: None. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Existing facilities consist of: The facility intends to discharge non - contact cooling tower blow down from two cooling towers at a rate of approximately two gallons per minute for a combined daily volume of about 5760 gpd. No treatment chemicals will be used. f. Please provide a description of proposedwastewater treatment facilities: N/A g. Possible toxic impacts to surface waters: none h. Pretreatment Program (POTWs only): Not needed. 2. Residuals handling and utilization/disposal scheme: N/A. 3. The compliance history for this facility within the past permit cycle is as follows: This is a new permit 4. Treatment plant classification: Class 0 5. SIC Code(s): 4952 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies (municipals only) involved? N/A 2. Special monitoring or limitations (including toxicity) requests: None 3. Important SOC, JOC or Compliance Schedule dates: N/A 4. Alternative Analysis Evaluation: Discharge appears to be the most feasible alternative. 5. Other Special Items: None PART IV - EVALUATION AND RECOMMENDATIONS The facility is going to be discharging non -contact cooling water into a drainage ditch which travels a very long distance until it reaches the tributary of Bachelor's creek. It should not cause any impact to the area. The permittee may want to provide a shielded outfall to prevent excessive erosion and turbidity issues. Prior to the use of any chemicals or biocides, the permittee must submit a completed Biocide 101 form and the manufacturers' information for review. It is recommended a permit be issued to the INGENCO Wholesale Power, LLC in accordance with the Neuse river basinwide plan. d e //43/0 Signature of Report Preparer Date ALLiatvr 11/175Jf Water Quality Regional Supervisor Date cc: WaRO NPDES Permit File Central Files 4b'r41:4 r. X Bite Canal! Vole 71.6%^:cry 'm 1 Map (g) z•,-elkirtaar •••• .21..111 11;4.00- itirn1l. • . - {Jill illtdE Ow* 14,o *in ma. we:kirk -.4r •-• -Ir. (3) Page 1 of 1 http://gismaps.cravencounty.com/output/craven_GISMAPS 1928338412647.png 9/20/2006 -To Kins46n ALTERNATIVES ANALYSIS General The discharge to be permitted is the non -contact cooling tower blow down water. The two cooling towers are the facility will discharge at a rate of approximately two gallons per minute for a combined daily volume of about 5760 gallons per day. No cooling tower treatment chemicals (anti-scalants, biocides, etc) will be used. The site for the project is located on the Central Regional Solid Waste Management Authority landfill site and will use existing drainage features to convey the wastewater to Bachelors Creek. The existing soils on the site include Ra — Rains fine sandy loam and GoA — Goldsboro loamy fine sand. Both of these soils have severe wetness conditions and a high water table. 1. Connection to Municipal or Regional Sewer Collection System The project site is located on the property of the Craven County Landfill in western Craven County. There are no existing or planned sewer collection systems within a 5 mile radius of the project site. The unavailability of an existing or planned system discounts this alternative. 2. Subsurface Disposal Infiltration systems were evaluated as an alternative but due to soil characteristics including severe wetness and a seasonal high water table between 1.5 and 5' below the surface, this was not considered a reasonable alternative. There is a small area on the landfill site currently used for on -site septic systems. This area is not large enough for this volume of disposal and would not allow any future expansion on the landfill site. The only alternative would be to find an offsite area and construct an infiltration system. 3. Spray Irrigation The adjacent landowners have been contacted about spray irrigation to be used on crops and due to the type of crop (mostly pine trees), the amount of discharge, soil type and the depth of the seasonal high water table, spray irrigation does not appear to be a viable option for the immediate adjacent areas. The closest area for possible spray irrigation disposal appears to be a farm approximately 1.5 miles away. However using exiting roadways and easements the distance is approximately 3.5 miles. 4. Wastewater Reuse Wastewater flow off -site will be minimized by installation of a 4,000 gallon tank located and maintained on site. Accumulated wastewater will be used by Landfill personnel for dust control when practicable and consistent with needs of the landfill. Excess wastewater will be discharged off -site. LAYOUT Page 1 of 1 INGENCO - Soils • Schools • Geodetic Monuments,tv Road Centerlines ▪ Parcel hooks Railroad Parcels Soils ■ ■ ■ ■ AaA AMA Ag Ao AuB Ba BrB CnB CrB CT DA De DO ExA GoA Gr GuA Kr KuB La Lc Le LF Ln Ly Mc MM Mu N *A HaB NuB On Pa PO Pt Ra CRAVEN COUNTY NORTH CAROLINA 0 1 1000 ft October 5, 2006 6:13:44 AM Craven County does not warrant the information shown on this map and should be used only for tax assessment purposes. Map made on October 5, 2006 at 5:24:42 PM http://gismaps.cravencounty.com/maps/map print.asp?pid=&minX=2525048.05491639&minY=521847.... 10/5/2006 PRESENT VALUE OF COSTS ANALYSIS 1. Infiltration - Off site. CAPITAL COSTS Land Costs Equipment Costs Installation Costs Design Costs $6,000.00 $22,000.00 $12,000.00 $8,000.00 TOTAL $48,000.00 RECCURING COSTS O & M $1,800.00 Permit and Compliance Fees $400.00 Utility Costs $1,500.00 TOTAL $3,700.00 PV = $48,127.00 2. Spray Irrigation - Closest Adjacent Farm Land CAPITAL COSTS Land Costs Equipment Costs Installation Costs Design Costs RECCURING COSTS $3,000.00 $120,000.00 $12,000.00 $10,000.00 TOTAL $145,000.00 O&M $6,000.00 Permit and Compliance Fees $500.00 Utility Costs $2,400.00 PV = TOTAL $8,900.00 $145,306.00 3. Wastewater Reuse - Landfill CAPITAL COSTS Land Costs $0.00 Equipment Costs $8,000.00 Installation Costs $3,000.00 Design Costs $1,500.00 TOTAL $12,500.00 RECCURING COSTS O&M $1,000.00 Permit and Compliance Fees $0.00 Utility Costs $800.00 TOTAL $1,800.00 PV = $12,561.00 PV = Present Value of costs Life of the Facility = 20 years r = current EPA discount rate = 6.0% TopoZone - USGS Jasper (NC) Topo Map Page 1 of 1 `53 Tenmiie ForJt 39' ::# i '`ZONAL 0 3 6 9 12 15 km 0 2 4 6 8 UTM 18 302642E 3893549N (NAD27) USGS Jasper (NC) Quadrangle Projection is UTM Zone 18 NAD83 Datum 10 mi - ta. Britt h1=-9.728 G=-1.249 http://www.topozone.com/print.asp?lat=35.16731 &lon=-77.16698&s=500&size=1&u=4&layer=DRG250... 9/18/2006 1NGENCO Distributed Energy October 26, 2006 Dr. Sergei Chernikov NPDES Permit Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Re: COC# NCG500635 Dear Dr. Chernikov The Local Government Review Form for Craven County concerning our application is attached. A Local Government Review Form was also submitted to the City of New Bern, and received on 10/10/06. At this time we have not received a reply from the City of New Bern. If you have any questions regarding this application, please contact me at (804) 521-3557 or by email at rgreene@ingenco.com. ingenco.com. Sincerely, Robert L. Greene, Ph. D. Environmental Compliance Manager 2250 Dabney Road Richmond, VA 23230 1804.521.3500 1804.521.3583 fax (l) 1NGENCO Distributed Energy October 9, 2006 NPDES Permit Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 p@CROW[E OCT 1 1 200E DENR - WATER QUALITY POINT SOURCE BRANCH Attached are three copies of a Notice of Intent for discharge of cooling tower blow down under NCG500000 and a check for $80 to cover the permit application fee. This application is for the INGENCO Wholesale Power facility to be constructed at the Tuscarora Landfill located at 7500 Old US Highway 70 West, New Bern, NC. If you have any questions regarding this application, please contact me at (804) 521-3557 or by email at rgreene@ingenco.com. ingenco.com. Sincerely, GG ale€16 obert L. Greene Environmental Compliance Manager 2250 Dabney Road Richmond, VA 23230 1804.521.3500 1804.521.3583 fax