Loading...
HomeMy WebLinkAbout210004_Inspection_20220118facility Nwnber D viSion of WaterResources 0 Division of Soil and Water Conservation 0 Other Agency Type of Visit: ® Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: ® Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: Farm Name: Owner Name: Mailing Address: Physical Address: Arrival Time: Departure Time: Owner Email: County:�,r,,v` , Region: /0 Phone: 9/9 — — sly Facility Contact: ( e %� i Tide: Phone: .),5"01 - 19 - 9Air Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Integrator: Certification Number: /77. f Certification Number: Latitude: Longitude: Swine Design Current Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Design Current Wet Poultry Capacity Pop. Layer Non -Layer Design Current Dry Poultry Capacity Pop. Layers Non -Layers Pullets Turkeys Turkey Poults Other Cattle Design Current Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑No ❑NA ❑NE ❑Yes ❑No ❑NA ❑NE ❑Yes ❑No ❑NA ❑NE ❑ Yes No NA ❑NE ❑ Yes ❑No ❑NA El NE ❑ Yes ❑No ❑NA ❑NE Page 1 of 3 5/12/2020 Continued , Number: ,/ - © it Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? a. If yes, is waste level into the structural freeboard? Date of Inspection: / -/f 22-- Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): ID Yes [ No ❑NA ❑NE ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes [J No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmen 1 threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes o ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes N,o ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes [t%, No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, Setbacks, or compliance alternatives that need ❑ Yes FZ(No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ['No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): ❑ Yes E<No ❑ NA ❑ NE 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ,No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes 4o El NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes le ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes 12(o ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? El Yes [ i No ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes No ❑ NA El NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes 11 No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑ Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes [] No ❑ NA ❑ NE El Waste Application El Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield El 120 Minute Inspections El Monthly and 1" Rainfall Inspectio ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes No ❑ NA ❑ NE Page 2 of 3 5/12/2020 Continued Facility Number: 4 / - Date of Inspection: C.� 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: ❑ Yes ❑ Yes mN ❑ Failure to develop a POA for sludge levels 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? Yes Yes Yes �No ❑NA ❑NE ❑NA El NE dNo ❑ NA ❑ NE Ef No ❑ NA ❑ NE 7No ❑NA ❑NE ❑ NA ❑ NE ❑ NA ❑ NE [No ❑ NA ❑ NE ❑ NA ❑ NE El NA ❑NE ❑ NA ❑ NE d # tz # 410400 0 EVL y.Y tS ansvaexs a idloxacT4ftion4keG4nitnen VOtilkovirags offiloW t4.:06tarlain-,ttua ons (use edditio ai s ar3 sec y 1l -)s- /r de citir/e azto-zzL.4„tt.„.61eL44.eed..- dlidOpit9 0011 bgIer Onine cto. rl f / , dzcolie,AwAiwg_IO/011')72,,) boa-/ — �� � _ // yiev n , Reviewer/Inspector Name: Reviewer/Inspector Signature: Page 3 of 3 Aar/ e " ` jn /y,r,(14 �?Y Phone: ,ate-74,3-- 0,;307 Date: / - J ' a-a- 5/12/2020