Loading...
HomeMy WebLinkAboutNCG500618_Correspondence_20100414HRP a Creating the Right Solutions Together April 14, 2010 Mr. Jim McKay NC DENR Division of Water Quality Surface Water Protection Section Point Source Branch 1617 Mail Service Center Raleigh, NC 27699-1617 are pe I_ APR 19 2010 QUALrrY POINT SOURivi BRANCH Re: Mack Molding Notification of New Discharge to be Covered by the NPDES General Permit # NCG500000 for Non -contact Cooling Water, Boiler Blowdown, Cooling Tower, Condensate and Hydroelectric Dams. HRP Job # MAC1047.WM Dear Mr. McKay: Pursuant to your request on March 5, 2010, this letter is being submitted to the NCDENR Division of Water Quality on behalf of Mack Molding Company, located at 149 Water Tank Road in Statesville, NC, in order to notify the division that the facility has installed a new air compressor which will discharge condensate to the ground. Mack Molding is currently covered by the General Permit #NCG500000 to discharge non -contact cooling water, cooling tower and boiler blowdown, condensate and similar wastewaters under the National Pollutant Discharge Elimination System (NPDES) under Certificate of Coverage #NCG500618. It is Mack Molding's understanding that due to their current coverage under the general permit, the air compressor condensate wastewater discharge will also be covered. The air compressor has been constructed with a PS PolySep Oil/Water Separator, which is designed to effectively separate emulsified compressor condensate to levels between 5-15 parts per million. The oil/water separator has been deemed by the manufacturer as a valuable benefit for ISO 140001 certified companies. For your reference, the PS PolySept Oil/Water Separator brochure and technical specifications guide has been included as an attachment to this letter. Mack Molding is aware of the semi-annual requirements for Oil and Grease monitoring as required under Part I A(1) of the General Permit, and has added the requirements to the preventative maintenance schedule. Mack Molding is also covered by the NPDES General Permit #NCG050000 for Stormwater Discharges Associated with Industrial Activity under Certification of Coverage #NCG050348. As such, Mack Molding is in the process of updating the site -specific Stormwater Pollution Prevention Plan (SPPP) to include the air compressor and its condensate discharge under the regular monthly inspection schedule. CONNECTICUT 197 Scott Swamp Road Farmington, CT 06032 800-246-9021 860-674-9570 FAX 860-674-9624 501 Kings Highway East Fairfield, CT 06825 203-610-8212 FAX 203-610-8102 FLORIDA 2435 US Highway 19 Suite 550 Holiday, FL 34691 727-942-2115 FAX 727-942-2113 INDIANA 7965 East 106th Street Suite 116 Fishers, IN 46038 317-570-4851 FAX 317-570-4852 NEW YORK 1 Fairchild Square Suite 110 Clifton Park, NY 12065 888-823-6427 518-877-7101 FAX 518-877-8561 SOUTH CAROLINA 1327 Miller Road Suite D Greenville, SC 29607 800-752-3922 864-289-0311 FAX 864-281-9846 www.hrpassociates.com H:1MVvlack Molding\Statesville, NC\MAC1047.WM NPDES Discharge Update 2010\NPDES Notification Cover Letter.doc Mr. Jim McKay NC DENR DWQ April 14, 2010 Page 2 Should you have any questions or concerns regarding this submittal, please do not hesitate to contact Mr. Frank Bumgarner of Mack Molding Company at (704) 878-4433 or myself at (864) 289-0311. Sincerely, HRP Associates, Inc. Shannon M. Cohen Project Scientist cc: Frank Bumgarner/Mack Molding Attachment H: M1Mack Molding1Statesviile, NCIMAC1047.WM NPDES Discharge Update 20101NPDES Notification Cover Letter.doc HRP f4o ,:e./ , r%n., Creating the Right Solutions Together The Ingersoll-Rand PS Polysep Oil/Water Seperator product offering is the most comprehensive environmental solution in the air compressor industry. The Problem with Other Oil/Water Separators Compressor oils that do not have good separation characteristics, known as emulsions, tend to foul up the carbon filters as well as the pre -adsorption and coalescing medias that are commonly installed in front of the carbon fdters.Those filters have to be replaced before their capacity is fully used.This is a result of oil binding off the pore area of the carbon where the condensate first comes in contact with the fdter.The jelled oil clogs the filter, which then prevents the volume of condensate from properly flowing through the filter.This premature failure of the carbon filters most often results in the system backing up on the floor. The IR Environmental Solution IR PolySep is designed to effectively separate emulsified compressor condensate, as well as oils that have better separation characteristics, to levels between 5-15 PPM or without premature element failure and backup spillages.These systems are designed to cover compressor ranges from 0,14-127 m3/min, and work effectively with Polyglycols Mineral Oils, PA0s, Polysol Esters & Diesters. Benefits • Non -corrosive materials • No electricity • Expandable system • CE Certified • Permanently adsorbs oils • Only two moving parts • Valuable for ISO 14001 certified companies • Extended filter life Technical Specifications Guide • Low maintenance costs • Helps protect and maintain the environment 1ludel PS-030 CPN 38041596 Max. int/min .85 Max. Kw 6 Adsurbtiun Module Volume (Lit.) 3.8 Air line NPT N/A Condensate Inlet NPT 1/2" Oil Outlet NPT 3/4" ►Vater Replacement Outlet Adsorption NPT Modules 3/4" 38041604 Dimensions LxWxH (nun) 292x292x699 Weight )Kg) 7 PS-060 42528455 1.70 11 7.6 N/A 1/2" 3/4" 3/4" 42528505 292x292x699 11 PS-125 38339040 3.54 22 19 N/A 1/2" 3/4" 3/4" 38339057 724x495x560 45 PS-250 42528463 7.07 37 57 1/4" 1/2" 3/4" 3/4" 42528513 1130x495x960 64 PS-560 42528471 15.85 90 113 1/4" 1/2" 3/4" 3/4" 42528521 1130x495x960 64 PS-1125 42528489 31.86 220 208 1/4" 1/2" 3/4" 3/4" 42528539 1130x495x960 64 POLYSEP ACCESSORIES Row Divider 22204432 Note: This component balances Toad between multiple PolySep units. maximizing element life and opthnlzing operation PolySep installation Kit .1233m73 Note: Kit includes (2) 4-way I/4" Manifolds. (2) ur x 318- Reducing Bushings and (8) 1/1- Plugs 9.5 Lit Oil Container 38339081 Note: 9.5111. 011 Container comes standard with PS-125. Needs to be purrhased separate with all other models. $0)Ingersolliand PS PolySep Oil!Water Separator 1 Diffuser Chamber 2 Main Reservoir 3 Oil Weir 4 Pick -Up Tube 5 Float 6 Ball Valve 7 Pump 8 Filter Module 9 Discharge Operation The condensate enters the diffuser chamber (I) when it is depressurized. The oily condensate then enters a main reservoir (2) where gravity separation occurs. Any oil that floats to the surface is skimmed off through an adjustable oil weir (3). The conden- sate then moves to a separate chamber through a pick-up tube (1). As the condensate accumulates in the next chamber, a float (5) rises with the level of condensate. The float is connected to a ball valve (6) by a lever arm. The increased level of condensate causes the float to rise and open the ball valve. As the valve opens, the air -operated pump (7) is allowed to push the condensate out to the filter module (8). If the level of condensate con- tinues to rise, the float also rises and further opens the ball valve. Cleaned water discharged (9) from the filter module can be disposed of directly into the facility's sanitary sewer. This system assures maximum contact time for the filter module. The PolySep system only requires compressed air to operate the diaphragm pump and is only used when the level of condensate rises enough to operate the pump. This system is reliable because there are only two moving parts. The PolySep filter modules are available in six separate sizes. The same delivery system is used for three larger filter modules. Thus, an expanded sytem may only require a larger filter module. Once spent, there are no mess bags to dispose of. The containers are totally self-contained and easily tranported by use of a forklift handle located at the top. More Than Air. Solutions. Online solutions: http://www.air.irco.com Water discharged from the PolySep condensate separation system is not intended or approved for human consumption. Installation of PolySep condensate separation system must be in accordance with all local and national regulations. Check with local municipality to determine permissible oil content in effluent. Regular monitoring of outlet water is required to ensure that permitted limits are not being exceeded. Nothing contained on these pages Is Intended to extend any warranty or representation.. expressed or implied, regarding the product described herein. Any such warranties or other aeons and conditions of safe of products shall be in accordance with Ingersoll-Rand's standard terms and conditions of sale for such products. which are available upon request. Product improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change without notice or obligation. Ingersopiland. Ingersoll-Rand Swan Lane. Handley Green. WN2 9EZ England 0 2005 Ingersoll-Rand Company CPN: 88323720 Printed in Spain