HomeMy WebLinkAboutNCG500596_Permit (Issuance)_20120808ATA
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Charles Wakild, P.E. Dee Freeman
Governor Director Secretary
August 8, 2012
Mr. Richard Shaver
Shaver Wood Products, Inc.
14440 Statesville Blvd
Cleveland, NC 27013
Subject: Renewal of coverage / General Permit NCG500000
Shaver Wood Products
Certificate of Coverage NCG500596
Rowan County
Dear Permittee:
The Division is renewing Certificate of Coverage (CoC) NCG500596 to discharge under NPDES
General Permit NCG500000. This CoC is issued pursuant to the requirements of North Carolina General
Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental
Protection agency dated October 15, 2007 [or as subsequently amended].
If any parts, measurement frequencies or sampling requirements contained in this General Permit
are unacceptable to you, you have the right to request an individual permit by submitting an individual
permit application. Unless such demand is made, the certificate of coverage shall be final and binding.
Please take notice that this Certificate of Coverage is not transferable except after notice to the
Division. The Division may require modification or revocation and reissuance of the certificate of coverage.
Contact the Mooresville Regional Office prior to any sale or transfer of the permitted facility.
Regional Office staff will assist you in documenting the transfer of this CoC.
This permit does not affect the legal requirements to obtain other permits which may be required by
the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area
Management Act or any other Federal or Local governmental permit that may be required.
If you have any questions concerning the requirements of the General Permit, please contact John
Hennessy [919 807-6377 or john.hennessy@ncdenr.gov].
Sincerely,
Original signed by John Hennessy
for Charles Wakild, P.E.
cc: Mooresville Regional Office / Surface Water Protection
NPDES file
1617 Mail Service Center, Raleigh, North Carolina 27699-1617
512 North Salisbury Street, Raleigh, North Carolina 27604
Phone: 919 807-6300 / FAX 919 807-6489 / Internet: www.ncwaterquality.org
An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper
NorthCarolina
Natural!,
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
GENERAL PERMIT NCG500000
CERTIFICATE OF COVERAGE NCG500596
TO DISCHARGE NON -CONTACT COOLING WATER, COOLING TOWER AND BOILER
BLOWDOWN, CONDENSATE AND SIMILAR WASTEWATERS UNDER THE
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and
the Federal Water Pollution Control Act, as amended,
Shaver Wood Products, Inc.
is hereby authorized to discharge Boiler Blowdown & Condensate from a facility located at
Shaver Wood Products
14440 Statesville Blvd
Cleveland
Rowan County
to receiving waters designated as an unnamed tributary to Fourth Creek in subbasin 03-
07-06 of the Yadkin -Pee Dee River Basin in accordance with the effluent limitations,
monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof.
This Certificate of Coverage shall become effective August 8, 2012.
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day August 8, 2012
Original signed by John Hennessy
for Charles Wakild, Director
Division of Water Quality
By Authority of the Environmental Management Commission
NCDENR
North Carolina Department of Environment and Natural R
Division of Water Quality
Beverly Eaves Perdue Charles Wakild, P.E.
Govemor Director
b to)
AUG 2 8 2012
- -vATER fiGATY
otiam -tikwyJRCE:i LIRANCH
Dee Freeman
Secretary
x •a iuE OF RENEWAL INTENT
Application for renewal of existing coverage under General Permit NCG500000
Existing Certificate of Coverage (CoC): NCG500 596
(Please print or type) p ( EIWE
s* of f i' owner/o erator: -
1) Mailing address* facility p
Pi'rJuct3Company Name ,'k ucr (L)nevi) Jy AUG 0 6 2012
Owner Name QrJit rei 5Ac,UP
POINT bunt Gt BRANCH
Street Address to -es 0,.//e, 6/act
City riate 1a,1 d State /1/C ZIP Code a2. 701,3
Telephone Number 7Ca I-1 ,2 7 5 ' %2 (1/ Fax: 70') 7 R - 93 D `/
Email address 6c1 p j ; m /Oo (& b e/t w -t% - net
* Address to which all permit correspondence should be mailed
2) Location of facility producing discharge:
Facility Name c.5A a ve ( /a,On cl Pr a c Uc-tS C_,
Facility Contact (.4 Cho cl S/1 ver
Street Address /'1'-1 W O S tq -tesoi //l Q/t.S
City e J e t'/ o n d State A/ C. ZIP Code .270/3
DENR-WATER QUALITY
County 12.0 u) 414
Telephone Number -70 L( 2 763 - 9a S / Fax: 70' / a 78- 93 D L/
Email address ,St op j ,' m br) e. •begSo to fib , n P
3) Description of Discharge:
a) Is the discharge directly to the receiving stream? O Yes CYNo
(If no, submit a site map with the pathway to the potential receiving waters clearly marked. This includes tracing the pathway of the
storm sewer to the discharge point, if the storm sewer is the only viable means of discharge.)
b) Number of discharge outfalls (ditches, pipes, channels, etc. that convey wastewater from the property):
u)osfie -ter 8 511 orinoci te r
c) What type of wastewater is discharged? Indicate which discharge points, if more than one.
O Non -contact cooling water Outfall(s) #:
(Boiler Blowdown
Outfall (s) #: I Mrcq Y
NCG500000 renewal application
❑ Cooling Tower Blowdown Outfall (s) #:
iCondensate Outfall (s) #: / Area D-
❑ Other Outfall (s) #:
(Please describe "Other")
d) Volume of discharge per each discharge point (in GPD):
#001: #002: #003: #004
C Ste q te-1, ed pc),
4) Please check the type of chemical [s] added to the wastewater for treatment, per each separate discharge
point (if applicable, use separate sheet):
0 Chlorine 0 Biocides /Corrosion inhibitors 0 Algaecide 0 Other
0 None
5) If any box in item (4) above [other than None] was checked, a completed Biocide 101 Form and
manufacturers' information on the additive must be submitted to the following address for approval:
NC DENR / DWQ / Environmental Sciences Section
Aquatic Toxicology Unit
1621 Mail Service Center
Raleigh, NC 27699-1621
6) Is there any type of treatment beg provided to the wastewater before discharge (i.e., retention ponds,
settling ponds, etc.)? 0 Yes No
(If yes, please include design specifics (i.e., design volume, retention time, surface area, etc.) with submittal package. Existing
treatment facilities should be described in detail. )
7) Discharge Frequency:
a) The discharge is: 0 Continuous
ig Intermittent 0 Seasonal*
i) If the discharge is intermittent, describe when the discharge will occur: Da ; l y a #
t)c ,L4 5 fi, mes
ii) *Check the month(s) the dischargeurs: Galan EebIlar. [(Apr I6May C9'dun iJul
dAug. IiSept. [ Oct. ftrNov. i?J Dec.
b) How many days per week is there a discharge? 7 c) Please check the days discharge occurs: [Aat. [fSun. E—/ Mon. ofTue. EiWed. CiThu. ahri.
Additional Application Requirements:
The following information must be included in duplicate [original + 1 copy] with this application or it will
be returned as incomplete.
> Site map. If the discharge is not directly tEi a Stream, the. pathway to the receiving iiwarn naus •
be clearly indicated. This includes tracing the pathway of a storm sewer to its discharge point.
imi oL i ation ictr r e presetitati l es. ii tt; appiicaeion will be submitted by a consulting
engineer (or engineering firm), include documentation from the Permittee showing that the
NCG500000 renewal application
consultant submitting the application has been designated an Authorized Representative of the
applicant.
Certification
I certify that I am familiar with the information contained in this application and that to the best of my
knowledge and belief such information is true, complete, and accurate.
Printed Name of Person Signing: Lt.) e �G d 310 ix
Title: li r c2 - P(Idr,i-
') 66.6a / �O /9o Ieq
(Signature of Applicant) I ( to Signed)
North Carolina General Statute 143-215.6 b (i) provides that:
Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document
fled or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Artide, or who
falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under
Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by
a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine
of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.)
This Notice of Renewal Intent does NOT require a separate fee.
The permitted facility already pays an annual fee for coverage under NCG500000.
Mail the original and one copy of the entire package to:
Mr. Charles H. Weaver
NC DENR / DWQ / NPDES
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Shaver Wood Products, Inc.
NOI NCG500000
Page 1
3) Description of Discharge
d) Volume of Discharge
1) Boiler is used to supply stream to two dry kilns. It is manually blown down
once per day for eight seconds. Maximum volume of discharge is estimated
to be 35-gallons. The boiler is not operated unless the kilns are operating.
2) Two dry kilns are typically charged and operated ten times per year. The
batch cycle is typically 7 days. The kilns occasionally produce condensate
when softwood is dried. The condensate from both kilns discharges to the
ground surface. The condensate is most likely to occur at the beginning of the
batch cycle. Condensate volume estimate is 1 — 10-gallons/hour worst. case
maximum.
4) Corrosion Inhibitors
Material Safety Data Sheets for the four corrosion inhibitors used. by Shaver are
included in attachment A. The chemicals used are manufactured by Anderson
Chemical company, Inc. of Macon, Georgia.
ANCO-OX 1040
ANCOTREAT 1190
ANCOTREAT 1200
ANCOSTREAM 2000
According to Anderson Chemical Company, Inc., the ANCOSTREAM 2000 is a
steam corrosion inhibitor. The active ingredient in the chemical (morpholine)
should be volatized in the boiler and should not be present in the blow down in
significant quantities.
7) Discharge Frequency
a) i) Boiler -eight second manual blowdown every 24 hours which typically occurs
approximately 70 times per year
Dry kilns -discharge presence dependent on type of wood dried
b) Boiler -eight second manual blowdown every 24 hours which typically occurs
approximately 70 times per year
Dry kilns -discharge presence dependent on type of wood dried
Shaver Wood Products, Inc.
NOI NCG500000
Page 2
14) Alternatives to Direct Discharge
a) Connection to a Regional Sewer Collection System
The sanitary sewer system from the Town of Cleveland does not extend to the
site. Should sanitary sewer become available, connection to the system may be
possible with appropriate notification and permitting.
b) Subsurface disposal (including nitrification field, infiltration gallery, injection
wells, spray irrigation, etc.)
The office building on site is currently the only building served by a subsurface
disposal system treating sanitary waste. Connecting the boiler blow down and
kiln condensate to the existing subsurface system would be difficult due to the
piping distances required and heavy vehicular and equipment traffic on the site.
The boiler blowdown and kiln condensate currently discharge to the ground
surface. Due to the relatively flat nature of the site, the wastewaters typically
infiltrate the ground surface. It is possible during a rain event that the
wastewaters could be conveyed by sheet flow to a drainage swale in the western
portion of the site. The swale intersects an intermittent stream in the wooded
area west of the site.
SOC PRIORITY PROJECT: No
To: NPDES Unit
Water Quality Section
Attention: Charles Weaver
?;! JUL 31 2007
Date: July 25, 2007 I i
NPDES STAFF REPORT AND RECOMMEND
County: Rowan
NPDES Permit No.: NCG500596
PART I - GENERAL INFORMATION
1. Facility and address: Shaver Wood Products
14440 Statesville Boulevard
Cleveland, NC 27013
DENR - `ii?l::R QUALITY
IONSoI„T so:; u E i3:;.\.!C4
2. Date of investigation: July 24, 2007
3. Report prepared by: Michael L. Parker, Environmental Engineer II
4. Person contacted and telephone number: Chad Shaver, (704) 278-9304
5. Directions to site: From the jct. of Knox Farm Road and Hwy. 70 (Statesville Boulevard)
in western Rowan County, travel east on Hwy. 70 1.4 miles. Shaver Wood Products
will be located on the left side of Hwy. 70.
6. Discharge point(s), list for all discharge points: -
Latitude: 35 ° 45' 03"
Longitude: 80° 44' 30"
Attach a USGS Map Extract and indicate treatment plant site and discharge point on map.
USGS Quad No.: D16SW
7. Site size and expansion area consistent with application: Yes. There is ample are for
WWTP construction, if necessary.
8. Topography (relationship to flood plain included): The site is relatively flat and is far
removed from any flood plain.
9. Location of nearest dwelling: Approx. 500± feet from the point of discharge.
Page Two
10. Receiving stream or affected surface waters: UT to Fourth Creek
a. Classification: C
b. River Basin and Subbasin No.: Yadkin 030706
c. Describe receiving stream features and pertinent downstream uses: The nearest
water body is several hundred feet from where the boiler blow down and kiln
condensate discharges. Based on the amount of discharge produced from the
boiler and kiln, it is highly unlikely that either discharge will ever reach the
receiving stream, even during periods of heavy rainfall. There are no known
downstream users.
PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS
1. a. Volume of wastewater: 35 gpd (Design Capacity)
b. What is the current permitted capacity: N/A
c. Actual treatment capacity of current facility (current design capacity): 35 gpd.
d. Date(s) and construction activities allowed by previous ATCs issued in the
previous two years: There have been no ATCs issued to this facility in the past
two years.
e. Description of existing or substantially constructed WWT facilities: There are no
existing WWT facilities
f. Description of proposed WWT facilities: There are no WWT facilities proposed at
this time.
g•
Possible toxic impacts to surface waters: There are no toxic impacts expected as
it is extremely unlikely that neither discharge will ever reach surface waters.
Corrosion inhibitors are added to the boiler blow down waste stream.
h. Pretreatment Program (POTWs only): Not Needed.
2. Residual handling and utilization/disposal scheme: There are no residuals generated.
3. Treatment plant classification: N/A
4. SIC Code(s):
Wastewater Code(s): 16, 14 MTU Code(s): N/A
PART III - OTHER PERTINENT INFORMATION
1. Is this facility being constructed with Construction Grant Funds or are any public monies
involved (municipals only)? No public monies were used in the construction of this
facility.
Page Three
2. Special monitoring or limitations (including toxicity) requests: Based on observations
made during the site investigation, monitoring of the condensate from the wood drying
process should not be a requirement of the renewed permit. There is no evidence to
suggest that any contaminants would be expected to bei found in the kiln condensate
should any condensate be generated. Secondly, The amount of condensate water will
likely never amount to more than a gallon or two based on current production. And
lastly, it would be physically impossible for the condensate water to reach surface waters
given the distance between the point of discharge and the nearest receiving waters. For
these reason, monitoring of the condensate outfall should not be included in the permit.
3. Important SOC/JOC or Compliance Schedule dates: N/A
4. Alternative analysis evaluation
a. Spray Irrigation: There is sufficient area available for surface irrigation, however,
it would be cost prohibitive given the small amount of wastewater generated to
construct a surface irrigation treatment system.
b. Connect to regional sewer system: None presently available to the site.
c. Subsurface: The applicant has the option of discharging the boiler blow down and
kiln condensate wastewater into a subsurface treatment system.
d. Other disposal options: None that we are aware.
PART IV - EVALUATION AND RECOMMENDATIONS
The applicant requests renewal of the subject permit for the discharge of boiler blow
down and kiln condensate wastewater. Given the proximity of the receiving waters to the
existing points of discharge, there is little, if any chance that any wastewater generated at this
facility will ever reach surface waters, even during periods of heavy rainfall. All wastewater
produced at this facility is discharged onto the ground and is absorbed with a few feet from
where the discharge occurs. Storm water outfalls are covered under a separate NPDES permit
NCG210352.
Pending a final technical review by the NPDES Unit, it is recommended that the subject
General Permit be renewed.
Signature of Report Preparer
/ 4
Water Quality Regional Supervisor
e
Date