Loading...
HomeMy WebLinkAboutWV0800305_Application_20220322North Carolina Department of Environmental Quality (DEQ) — Division of Water Resources (DWR) Existing permit number (if applicable) VARIANCE APPLICATION FOR WELL CONSTRUCTION STANDARDS: WATER SUPPLY WELLS UNDER 15A NCAC 02C .0107 All water supply wells not considered "Private Drinking Water Wells" and including irrigation, industrial, and commercial wells. WELLS OTHER THAN WATER SUPPLY UNDER 15A NCAC 02C .0108 Including monitoring and recovery wells. PRIVATE DRINKING WATER WELLS UNDER 15A NCAC 02C .0300 Print clearly or type information. Illegible submittals will be returned as incomplete. DATE* March 16 , 2022 Issued Date: Exp. Date: Permit No. for new projects (to be completed by DWR/DPH) A. WELL OWNER(S) — For single family residences, list all persons appearing on property deed. For all others, list name of the business/government agency and person and title with delegated signature authority: Town of Wallace / Laurence Bergman Mailing Address: 316 E Murray St City: Wallace State: NC Zip Code: 28466 County: Pender Day Tele No.: 910 285 4136 Cell No.: 910-271-8955 EMAIL Address: lbergman(a wallacenc.gov Fax No.: B. PHYSICAL LOCATION OF WELL SITE Parcel Identification Number (PIN) of well site: 2395-83-7713-000L County: Pender Physical Address (if different than mailing address): 250 Henderson Field Rd. City: Wallace County: Pender Zip Code: 28466 C. WELL DRILLER INFORMATION (if known) Well Drilling Contractor's Name: Matthew English NC Well Drilling Contractor Certification No.: Company Name: E&B Water Well and Pump Service Contact Person: Matthew English City: Teachey State: NC Zip Code:28464 County: Duplin Day Tele No.: 910-284-5489 Cell No.: EMAIL Address: e.b.welldrilling.nc(lgmail.com Fax No.: GW-22V Variance Request Form Rev. 7-13-2020 Page 1 D. REASON FOR VARIANCE REQUEST - Include type of well(s) to be constructed; rule for which the variance is being requested; description of how the alternate construction will not endanger human health and welfare and the environment; and reason why construction and/or operation in accordance with the standards is not technically feasible and/or provides equal or better protection of the groundwate • (refences to attached documents are acceptable). The type of well to be constructed is a 4in non -potable irrigation well. The intent of this well is to allow crop spraying aircraft to fill with water at the airport as opposed to hauling in water The variance requested is to allow the well to be 50ft from two 10 000-gallon ASTs. These tanks are double wall tanks The condition and operation of these tanks are regulated and monitored by NCDOT on behalf of the federal government and follow strict NFPA and FAA guidelines. Historically, USTs have been on site but were removed several years ago. Upon removal, monitoring wells were located in numerous locations and were recently closed and sealed. The USTs and the monitoring wells are in proximity (500ft) from two drinking wells, one that supplies water to the airport buildings and no issues have ever been reported to the Town regarding contaminates in drinking water or monitoring wells. Additionally, the well will be located up hill from the ASTs. Also, our staff is regulaily trained to use and maintain these systems which greatly mitigate the risks of spills or contamination. Since the tanks were installed around 2006, no spills or misfuelling incidents have been reported. Attached is a map of the proposed well location and a letter from the Town Manager stating that they are aware of the proposed application and approve the overall project. E. ATTACHMENTS - Provide the following information as attachments to this application: A map showing general location of the property (including road names, NC State Route Number, distances, any key landmarks, etc.) sufficient for finding the well location. Detailed site map with scale showing location of proposed well relevant to septic system(s), building foundations, property lines, water bodies, potential sources of contamination, other wells, etc. Submit a copy of the local well permit application and site evaluation map (if applicable). Any other information relevant to the variance request such as a well construction diagram showing proposed well liner or atypical construction materials/methods. GW-22V Variance Request Form Rev. 7-13-2020 Page 2 (b) Wells Other than Water Supply under 15A NCAC 02C .0108. If these wells are to be constructed on property not owned by the well owner or applicant, please also attach and submit a completed Application to Construct a Monitoring or Recovery Well System (GW-22MR) found on our website at: http://deq.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-appl ications Submit one copy of the completed vai iance application to the Division of Water Resources Regional Office seiving the area in which the well will be located: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5043 Telephone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Telephone: (704) 663-1699 Fax: (704) 663-6040 WINSTON-SALEM RALEIGH ASHEVILLE • • • RESVILL Raleigh Regional Office 1628 Mail Service Center Raleigh, NC 27699-1628 Telephone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Telephone: (252) 946-6481 Fax: (252) 975-3716 FAYETTEVILLE • WASHINGTON Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Telephone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Rd. Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22V Variance Request Form Rev. 7-13-2020 Page 4 F. SIGNATURE(S) Signature(s) of WeII/Property Owner(s) leAntiret.) C . * +vs/vs) ''vwr- N�sN Print or Type WeII/Property Own P • on Respons e for We onstruction Typically, well driller) \\.edv` 5 mm-e--) Print or ype Same of Persoesponsible for Well Construction (Typically, the well driller) Signature of County Environmental Health Specialist (for Private Water Wells) Print or Type Full Name and Title of County Environmental Health Specialist (for Private Water Wells) Per 15A NCAC 02C . 0118 the Secretary of the Division of Water Resources or the Division of Public Health may require submittal of information deemed necessary to make a decision on the variance, may impose conditions as part of the decision, and shall respond in writing to the request within 30 days of receipt of the variance request. A variance applicant who is dissatisfied with the decision of the Director inlay coininence a contested case by, filing a petition as described in G.S. 150B-23 within 60 days after receipt of the decision. G. SUBMITTAL INSTRUCTIONS (1) For the following types of water supply wells only: (a) Private Drinking Water Wells under 15A NCAC 02C .0300 (b) Irrigation Wells underl5A NCAC .02C .0107 with a designed capacity of less than 100,000 gallons per day and located on the same property as an on -site wastewater system permitted by a local health department. Prior to submittal of the variance for these types of wells, please contact your regional environmental health specialist by visiting: http://ehs.ncpublichealth.com/contacts.htm Submit one copy of the completed variance application to: North Carolina Department of Health and Human Services Division of Public Health — Environmental Health Section On -Site Water Protection Branch 1632 Mail Service Center Raleigh, North Carolina 27699-1632 (2) For the following types of wells only: (a) All Water Supply Wells under 15A NCAC 02C .0107 other than the ones listed under (1) above GW-22V Variance Request Form Rev. 7-13-2020 Page 3 T'own of WaCCace 316 EAST MURRAY STREET • WALLACE, NORTH CAROLINA 28466 • PHONE: 910-285-4136 MAYOR Charles C. Farrior, Jr. TOWN MANAGER Laurence C. Bergman March 16, 2022 To Whom it May Concern, TOWN COUNCIL Warren Hepler, Mayor Pro -Tern Wannetta Carlton William Jeffrey Carter Frank Brinkley Jason Wells TOWN CLERK Jackie Nicholson TAX ADMISTRATOR Chris Martin FINANCE DIRECTOR Shameshia Fennell TOWN ATTORNEY Anna Heath As the Town Manager of the Town of Wallace, I am aware of the well project at 250 Henderson Field Road at the Airport and authorize Gage King, the Airport Manager to submit the variance application on the behalf of the Town. The Town of Wallace supports the project assuming all environmental and regulatory demands are met. The completion of this project will allow our airport to better serve our community and local businesses. Sincerely, Laurence Bergman Town Manager Ma&ant... progrmiv¢... pro8pgrou8 FAX: 910-285-5135 • EMAIL: mail@wallacenc.gov • WEB: http://www.wallacenc.gov The Town of Wallace is an equal opportunity provider and employer. A < e-7 ) V • r 4/0 rinkine,11 • • Proposed Well Location (,50ft nom ASTs) Google Earth