Loading...
HomeMy WebLinkAboutNC0076775_Staff Report_19940113NPDES DOCIMENT !;CANNIN`i COVER SHEET NPDES Permit: NC0076775 Falls Powerhouse Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Staff Report Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: January 13, 1994 This document isa printed on reuiee paper - ignore a,uy content on the e w e aide ti cukteu M e To: Permits and Engineering Unw Water Quality Section Attention: Sean Goris NMi8 1994 EcH ;di P r-ip,0 ,,r P rb j e c t: No wit + ;,�:;, •,.: t, Date: January 13, 1994 NPDES STAFF REPORT AND RECOMMENDATIONS County: Stanly NPDES Permit No.: NC0076775 MRO No.: 94-7 PART I - GENERAL INFORMATION 1. Facility and Address: Falls Powerhouse c/o Yadkin, Inc. Post Office Box 576 Badin, N.C. 28009 2. Date of Investigation: April 16, 1992 3. Report Prepared By: Michael L. Parker, Environ. Engr. II 4. Person Contacted and Telephone Number: Mr. David Jones, (704)422-5627. 5. Directions to Site: From the jct. of Hwy. 740 and SR 1719 (Falls Road) in the Town of Badin, travel east on SR 1719 to the end of the road (the road changes to SR 1727). The Falls Powerhouse is located at the end of SR 1727. 6. Discharge Point(s), List for all discharge Points: Latitude: 35° 23' 44" Longitude: 80° 04' 34" Attach a USGS Map Extract and indicate treatment plant site and discharge point on map. USGS Quad No.: E 18 NE 7. Size (land available for expansion and upgrading): There is little, if any, area available for the construction of wastewater treatment facilities. 8. Topography (relationship to flood plain included): The Powerhouse is located on the main segment of the Yadkin River; however, the hydroelectric generation facilities are not subject to flooding. 9. Location of Nearest Dwelling: The nearest dwelling is at least 1000 feet from the Powerhouse site. Page Two 10. Receiving Stream or Affected Surface Waters: Yadkin River a. Classification: WS-IV and B b. River Basin and Subbasin No.: Yadkin 03-07-08 c. Describe receiving stream features and pertinent downstream uses: The Yadkin River is used for primary and secondary recreation and electricity generation. There are no known water intakes several miles below this Powerhouse. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater: (MGD) Outfalls: 001 & 003 002 & 004 005 007 0.432 0.0432 0.4752 0.00072 b. Current permitted capacity: N/A c. Actual treatment capacity: N/A d. Description of existing or substantially constructed treatment works: There are no existing treatment works nor are any proposed. For domestic wastewater disposal, employees have an on -site subsurface disposal system. e. Possible toxic impacts to surface waters: None. There are no biocides added to the cooling water at this facility. d. Pretreatment Program (POTWs only): N/A 2. Residuals handling and disposal scheme: There are no residuals generated. 3. Treatment Plant Classification: This facility does not meet the minimum criteria for a class I rating. 4. SIC Code(s): 4911 Wastewater Code(s): Primary: 48 Secondary: N/A 8. MTU Code(s): N/A PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grants Funds (municipals only)? No Page Three 2. Special monitoring requests: None at this time. 3. Additional effluent limits requests: None at this time. 4. Air Quality and/or Groundwater concerns or hazardous materials utilized at this facility that may impact water quality, air quality or groundwater? No AQ or GW concerns nor are hazardous materials utilized at this facility. PART IV - EVALUATION AND RECOMMENDATIONS The applicant, Yadkin, Inc. (a subsidiary of ALCOA), operates a powerhouse (dam) on the Yadkin River known as Falls Powerhouse, which generates hydroelectric power used in ALCOA's aluminum manufacturing process. Complex electrical generation machinery exists at this facility that requires cooling water during operation. There have been no changes and/or modifications to this facility since the Permit was last issued (12/23/92). It is recommended that an NPDES Permit be renewed as requested. Signature of Report Preparer Date /2( Water Quality Regi•oral Supervisor Date • v (.0 ''-'4:::111(.11%nn411W '---111111."‘A11\1111LIN- SCALE 0.-** • (MORROW MOUNTNN) 011:74 \"-MregailliegMffilirtiPr." oaks 2'30' MI. TO INC. 24 ANO 27