HomeMy WebLinkAboutWQ0002284_Compliance Report_20220321Compliance Inspection Report
Permit: WQ0002284 Effective: 08/17/18
SOC: Effective:
County: Dare
Region: Washington
Expiration: 02/28/23
Expiration:
Contact Person: Ray E Hollowell Title: Manager
Owner : Outer Banks/Kinnakeet Associates LLC
Facility: Kinnakeet Shores WWTP
41105 Big Kinnakeet Dr
Avon NC 27915
Phone:
Directions to Facility:
On the outer banks, take NC Hwy 12 south of Rodanthe to Avon and take a right onto Big Kinnakeet Drive and follow to the gated
end of drive
System Classifications: SI, WW2,
Primary ORC: David Pharr Certification: 21101 Phone: 252-473-3461
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 03/02/2022 Entry Time 09:OOAM
Primary Inspector: Robert B Tankard
Secondary Inspector(s):
Robert E Bullock
Sarah AToppen
Reason for Inspection: Follow-up
Permit Inspection Type: Reclaimed Water
Facility Status: ❑ Compliant Not Compliant
Question Areas:
▪ Treatment Flow Measurement -Effluent
▪ Treatment Flow Measurement -Water
Use Records
▪ Treatment Filters
▪ Treatment Disinfection
▪ End Use -Reuse
(See attachment summary)
Exit Time: 11:15AM
Phone: 252-946-6481 Ext.233
Inspection Type: Compliance Evaluation
▪ Treatment Flow Measurement -Influent
▪ Treatment
▪ Treatment Activated Sludge
▪ Treatment Flow Measurement
▪ Standby Power
▪ Miscellaneous Questions
▪ Treatment Barscreen
▪ Treatment Clarifiers
▪ Treatment Return pumps
▪ Wells
Page 1 of 6
Permit: WQ0002284 Owner - Facility:Outer Banks/Kinnakeet Associates LLC
Inspection Date: 03/02/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Follow-up
Inspection Summary:
The facility was inspected on March 2, 2022, to verify any repairs that had been made to the facility since the last NOV. No
improvements were made. However, Ms. Michelle Pharr showed the inspectors a copy of a certified check with order for the
clarifier gear box assembly. Stated that the assembly should be in within the next month. The following violations still exist
at the facility:
*Both clarifiers are out of service.
*Tertiary filter is out of service.
*Anoxic mixing pumps need to be repaired.
*Return pumps need to repaired or replaced.
*Chlorine was present but was not being metered into the tertiary filter.
*Irrigation equipment needs repair. System is non -operational.
*Back-up generator needs to be replaced or repaired.
*Failure to submit site map.
*Failure to install monitoring wells.
*Solids need to be removed from the wwtp.
*Bypasses are being used to pump wastewater from the clarifier and tertiary filter to the UV channel.
SAMPLE RESULTS FROM 01/11/2022 SAMPLE INSPECTION FOR THE EFFLUENT:
BOD: 35 MG/L
MF COLIFORM: >1200 colonies/100 ML
NH3: 0.52 MG/L
TURBIDITY: 24 NTU
TSS: 32 MG/L
TURBIDITY METER READ 4.0 NTU ON 1/11/2022. THE TURBIDITY METER HAS BEEN SUSPECT FROM PREVIOUS
INSPECTIONS. DWR WILL REQUIRE METER CALIBRATION DOCUMENTATION FROM ATHIRD PARTY.
Page 2 of 6
Permit: WQ0002284 Owner - Facility:Outer Banks/Kinnakeet Associates LLC
Inspection Date: 03/02/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Follow-up
Type
Reuse (Quality)
Infiltration System
Lagoon Spray, LR
Activated Sludge Spray, LR
Single Family Spray, LR
Activated Sludge Spray, HR
Activated Sludge Drip, LR
Single Family Drip
Recycle/Reuse
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Yes No NA NE
IEI
IEI
IEI
IEI
•
Yes No NA NE
• ❑ ❑ ❑
Comment: CLARIFIERS, RETURN PUMPS, TRAVELLILNG BRIDGE FILTER, DISINFECTION, GENERATC
AND SPRAY IRRIGATION SYSTEM IS NOT FUNCTIONAL.
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Yes No NA NE
Yes No NA NE
Comment: OPERATOR STATED FLOW METER IS NOT WORKIG AND USING AVERAGE FLOWS FROM
2021. OPERATOR STATED THIS ON 01/11/2022 INSPECTION.
Page 3 of 6
Permit: WQ0002284 Owner - Facility:Outer Banks/Kinnakeet Associates LLC
Inspection Date: 03/02/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Follow-up
Standby Power
Is automatically activated standby power available?
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment: GENERATOR DOES NOT FUNCTION.
Treatment Barscreen
Is it free of excessive debris?
Is disposal of screenings in compliance?
Are the bars spaced properly?
Is the unit in good condition?
Comment:
Treatment Activated Sludge
Is the aeration mechanism operable?
Is the aeration basin thoroughly mixed?
Is the aeration equipment easily accessed?
Is Dissolved Oxygen adequate?
Are Settleometer results acceptable?
Is activated sludge an acceptable color?
Comment:
Treatment Clarifiers
Are the weirs level?
Are the weirs free of solids and algae?
Is the scum removal system operational?
Is the scum removal system accessible?
Is the sludge blanket at an acceptable level?
Is the effluent from the clarifier free of excessive solids?
Yes No NA NE
❑• ❑ ❑
❑•❑ ❑
❑•❑ ❑
❑ • ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ ❑•
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
•
❑ ❑ ❑•
•
•
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
❑•❑ ❑
❑•❑ ❑
• ❑ ❑ ❑
▪ •
▪ •
Comment: CLARIFIER DOES NOT FUNCTION. SOLIDS ARE THICK WITHIN THE CLARIFIER. THERE
WERE TWO BYPASSES SET UP WITHIN THE CLARIFIER WHICH WENT DIERECTLY TO THE
UV CHANNEL. THIS FLOW BYPASSED THE TERTIARY FILTER AND CHLORINE
DISINFECTION SYSTEM. OPERATOR HAD PUT CHLORINE TABLETS IN EFFLUENT
CHANNEL BUT DID NOT MEET THE DETENTION TIME.
Treatment Return pumps
Are they in place?
Are they operational?
Yes No NA NE
• ❑ ❑ ❑
❑•❑ ❑
Comment: OPERATOR STATED THEY DO NOT FUNCTION. THEREFORE SOLIDS ARE BUILDING UP IN
THE THE CLARIFIER. SEVERAL PUMPS WERE MISSING FROM THE PIPING.
Page 4 of 6
Permit: WQ0002284 Owner - Facility:Outer Banks/Kinnakeet Associates LLC
Inspection Date: 03/02/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Follow-up
Treatment Filters
Is the filter media present?
Is the filter media the correct size and type?
Is the air scour operational?
Is the scouring acceptable?
Is the clear well free of excessive solids?
Is the mud well free of excessive solids and filter media?
Does backwashing frequency appear adequate?
Comment: TRAVELLING BRIDGE FILTER IS NOT FUNCTIONAL AND IS BEING BYPASSED.
Treatment Disinfection
Is the system working?
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
Is the system properly maintained?
If gas, does the cylinder storage appear safe?
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
If tablets, are tablets present?
Are the tablets the proper size and type?
Is contact chamber free of sludge, solids, and growth?
If UV, are extra UV bulbs available?
If UV, is the UV intensity adequate?
# Is it a dual feed system?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
Comment: DISINFECTION IS BEING BYPASSED. SYSTEM IS DESIGNED FOR CHLORINE TO BE
INJECTED UPSTREAM OF THE FILTER. FILTER IS BEING B YPASSED. OPERATOR IS
PLACING TABLETS IN EFFLUENT CHANNEL. DOES NOT MEET RETENTION TIME!
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ ❑•
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑
End Use -Reuse
Is the acreage in the permit being utilized?
Does the acreage specified in the permit correspond to the measured acreage at the site?
Are all essential units provided in duplicate?
Is an automatically activated standby power source available?
Is the equalization capacity adequate?
Is aerated flow equalization present?
Yes No NA NE
❑ ❑ ❑ •
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Yes No NA NE
❑ • ❑ ❑
❑ • ❑ ❑
• ❑ ❑ ❑
Page 5 of 6
Permit: WQ0002284 Owner - Facility:Outer Banks/Kinnakeet Associates LLC
Inspection Date: 03/02/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Follow-up
Has the turbidity meter been calibrated in the last 12 months?
Does the turbidity meter have recording capabilities?
Is all flow diverted at the appropriate times?
Is all upset wastewater diverted from reuse storage unit?
Is all upset wastewater treated, retreated, or disposed of acceptably?
Is upset wastewater treated prior to discharge to irrigation storage?
Is public access restricted from irrigation area during active site use?
If golf course, is a sign posted in plain sight on the club house?
Is the cover crop acceptable?
Are buffers adequate?
Is the site free of ponding/runoff?
Is the acreage in the permit being utilized?
Is the application equipment acceptable?
Is the application area free of limiting slopes?
How close is the closest water supply well?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
Is municipal water available in the area?
Are GW monitoring wells required?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Comment: SPRAY IRRIGATION IS NOT FUNCTIONAL. ALL WASTEWATER IS SENT TO THE
INFILTRATION/IRRIGATION POIND WHEHER IT MEETS REUSE OR NOT. TURBIDITY METE
DOES NOT WORK AND NOT SURE IF THE VALVES CAN BE AUTOMATICALLY TURNED
WHEN FECAL COLIFORM DOES NOT MEET LIMITS.
❑ ❑ ❑ •
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
❑ ❑ ❑ •
El El El El
• ❑ ❑ ❑
❑ • ❑ ❑
❑ • ❑ ❑