HomeMy WebLinkAboutNCG551602_Permit (Issuance)_20130919ARRA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Programs Pat McCrory Thomas A. Reeder John Skvarla, III Governor Director Secretary September 19, 2013 David Paletta, Owner 8201 S Crestwyck Court Raleigh, North Carolina 27615 Subject: Issuance of Certificate of Coverage NCG551602 and Authorization to Construct Under General Permit NCG550000 for Single -Family Residence located at 4178 Hwy 421 N, Vilas 28692 Watauga County Dear Mr. Paletta: General Permit Coverage. Upon application for discharge, DWR instructed you to apply for an individual NPDES permit due to legal issues preventing coverage under General Permit NCG550000. Having resolved these issues, DWR hereby forwards a Certificate of Coverage (COC) under the subject general permit. This permit is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated October 15, 2007 (or as subsequently amended). Your permit package includes: • A copy of the Certificate of Coverage (COC) for your treatment facility ▪ A copy of Plans and Specifications signed September 4, 2013 • A copy of General Wastewater Discharge Permit NCG550000 • A copy of a Technical Bulletin for General Wastewater Discharge Permit NCG550000 • Engineer's Certification form (to be completed and returned to DWR). According to your application, the existing subsurface septic -system will be replaced with a surface -discharge Septitech treatment system for a single-family residence (4 bedrooms, 120 gpd / bedroom). Your authorized consultant, Lash Engineering, notes that the Town of Boone provides the nearest sanitary sewer service, but that costs to connect are prohibitive due to the distance from the project [-2.7 miles (14, 256 feet) southeast]. Operation and Maintenance. As Permittee you are responsible to maintain all components in the approved treatment system, and the system will be held accountable to meet Surface Water - Quality Standards. Compliance includes following manufacturer's guidelines, conducting and documenting inspections, establishing sources for OEM spare parts and supplies, making necessary repairs, and documenting said maintenance for the duration of the permit. N. C. Division of Water Resources / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 Internet: h2o.enr.state.nc.us Phone: (919) 807-6300 fax: (919) 807-6495 DENR Customer Service Center: 1 800 623-7748 Upon DWR's request, the Permittee must provide records and demonstrate efforts to maintain the approved system. The Division recommends that the Permittee seek manufacture -certified training, or a qualified contractor service to regularly inspect and maintain the treatment system. This effluent discharges to State Surface Waters, Class C. Please note that if this stream classification changes, the Division may revisit this discharge and adjust the COC according to the stream's designated uses. This COC is not transferable except after written notice to the Division of Water Resources. The Division may modify, or revoke and reissue this COC. This permit does not affect your legal responsibility to obtain other permits required by the Division of Water Resources, the Division of Land Resources, the Coastal Area Management Act, or any other Federal or local government. If any parts, measurement frequencies or sampling requirements contained in this general permit are unacceptable, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this Certificate of Coverage (COC) shall be final and binding. Authorization to Construct (ATC) Permit. Compliance under this COC restricts discharge flow to 100%-domestic, not to exceed 1,000 gallons per day. Treated effluent shall be routed into a roadside ditch draining to Brushy Fork [Stream Segment 8-15-10], a waterbody currently classified C within Subbasin 04-02-01 of the Watauga River Basin. In accordance with the application and the attached approved plans and specifications, DWR hereby authorizes installation and operation of: • [existing] 1,000-gallon septic tank with inspection risers and effluent filter • 1,000-gallon Septitech treatment pod with inspection risers [Fralo Plastic Tank, 2-compartment RMT 1060] • UV disinfection unit (Smart UV, single bulb w/ alarm) • treatment system control panel • effluent piping and sample point • discharge to outfall, erosion -controlled (riprap) This system shall be installed at least 15 feet from the dwelling foundation, 50 feet from the property lines [hereby waved to 5 feet from the roadside right-of-way due to restrictive lot size], and 100 feet from water supply wells onsite or offsite [hereby waved to 65 feet down -gradient of existing well, do to restrictive lot size], as approved by DWR's Asheville Regional Office (ARO). The system shall be located and constructed above any designated 100-year flood line. Treatment -system cleanouts are required and should be installed between the septic tank and treatment -system transition points and elbows, as well as any transition points in the 4-inch gravity discharge line. All cleanouts must be housed in meter boxes below grade. All piping elbows must conform to the long -sweeping type. This ATC permit is issued in accordance with Part III, Paragraph 2 of NPDES General Permit NCG550000, and is subject to revocation unless wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in this General Permit. In the event that the facilities fail to perform satisfactorily, including creating nuisance conditions, the Permittee shall take immediate corrective action as may be required by this Division, such as the construction of additional or replacement wastewater treatment(s) or disposal facilities. Failure to • abide by the requirements of this A to C permit may subject the Permittee to an enforcement action by the Division of Water Resources in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The Permittee or responsible Engineer shall notify DWR's Asheville Regional Office (828-296- 4500) a minimum of three (3) working days in advance of operating the installed facilities. This will serve to provide DWR an opportunity to inspect facilities as built. Such notification to the Regional Office staff shall be made during normal office hours from 8:00 a.m. until 5:00 p.m. Monday through Friday, excluding State holidays. Upon completing construction and prior to operating this permitted facility, a North Carolina -registered engineer shall sign and submit to DWR the attached Engineer's Certification form certifying that the permitted facility has been installed in accordance with the NPDES Permit, the Certificate of Coverage, this Authorization to Construct, and the approved plans and specifications. Compliance with the above shall include a leakage test performed on the septic tank and the pump /dosing tank to insure that any exfiltration occurs at a rate not to exceed twenty (20) gallons per twenty-four (24) hour per 1,000 gallons of tank capacity. The Engineer's Certification shall serve as proof of compliance with this condition. Mail the completed Engineer's Certification to: DENR / DWR/ NPDES Program 1617 Mail Service Center Raleigh, NC 27699-1617 The Permittee shall maintain on site for the life of the treatment facility, a copy of the approved plans and specifications. NPDES Contact. If you have any questions concerning the requirements of this Certificate of Coverage or the Authorization to Construct permit, please contact Joe R. Corporon, L.G. at telephone 919-807-6394 or email joe.corporon@ncdenr.gov. Thomas A. Reeder Attachments: Engineer's Certification form hc: Central Files Asheville Regional Office, Attn: Jeff Menzel, Environmental Specialist NPDES General Permit Files ec: Lash Engineering, Attn: Mike Lash, P.E. [Mike@lashengineering.com] ARO Attn: Jeff Menzel/Chuck Cranford [This page intentionally left blank] STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES CERTIFICATE OF COVERAGE - NCG551602 Under GENERAL PERMIT NCG550000 TO DISCHARGE 100% DOMESTIC WASTEWATERS FROM A SINGLE-FAMILY RESIDENCE AND OTHER DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, David Paletta — Owner is hereby authorized to operate a wastewater treatment facility consisting of a, septic tank, Septitech POD treatment system with single -bulb ultraviolet (UV) disinfection, control panel and associated appurtenances, effluent discharge pipe with outfall rip -rap erosion protection; discharging treated 100% domestic wastewater from a facility located at Single -Family Residence 4178 Hwy 421 N., Vilas 28692 Watauga County to receiving waters designated as Brushy Fork [stream segment 8-15-10], a waterbody currently Classified C within Subbasin 04-02-01 of the Watauga River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit NCG550000 as attached. This certificate of coverage shall become effective September 19, 2013. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day September 19, 2013. T ► • as Reeder, Director vision of Water Resources By Authority of the Environmental Management Commission Outfall 001 (flows west) David Paletta — Owner 4178 NC Hwy 421 N, Vilas 28692 State Grid/USGS Ouad: Drainage Basin: Receiving Stream: Stream Segment: Latitude: C12NW / Boone, NC Watauga River Basin Brushy Fork 8-15-10 36° 14' 09" N Sub -Basin: 04-02-01 HUC: 06010103 Stream Class: C Longitude: 81° 44' 32" W North Linville Creek Road General Permit COC NCG55 1602 Watauga County Fact Sheet NPDES New Permit Development - Complex Expedited FOR: Single -Family Residence Application / Permit History This is a new WWTP permit. The Applicant proposes to install wastewater treatment technology as alternative to conventional sandfilter; a Septitech treatment system [M400D-UV-fiberglass]. The application for discharge suggests that this system provides treatment comparable or better than a conventional sand filter system for100% -domestic discharges < 1,000 gallons per day (gpd). However, this treatment alternative is not specified in currently -active General Permit NCG550000 and is not permittable. Therefore, the Division will issue the Applicant an individual NPDES permit, NC0089362 SFR for a time period only until General Permit NCG55000 may specify alternative technology (in progress). n1 C�sS��a 2 ^~ Facility Information Applicant/Facility Name David Paletta - Single -Family Residence Applicant Address 8201 S. Crestwyck Court, Raleigh 27615 Facility Address 4721 NC Hwy 421 N, Vilas 28692 Permitted Flow 4-bedroom @120 gpd = 480 gpd Type of Waste 100% Domestic — sanitary sewer Facility / Permit Status Minor / NEW Basin / County Watauga River Basin / Watauga County Miscellaneous Receiving Stream Brushy Fork [8-15-10] Regional Office: Asheville Stream Classification C State Grid / USGS Topo Quad: C12NW / Boone, NC 303(d) Listed? Not listed Permit Writer: Joe R. Corporon, L.G. Subbasin 04-02-01 Date: July 22, 2013 Drainage Area (mil) . . , LAT: 36° 14' 09- LONG: 81° 44' 32" Summer 7Q 10 (cfs) 0.0 Winter 7Q10 (cfs) 0.0 30Q2 (cfs) 0.0 Average Flow (cfs) 0.0 IWC (%) 100 Effluent Limit Development — Permit Requirements and Dates This permit's expiration date is established to be consistent with neighboring individual NPDES permits within Subbasin 04-02-01 of the Watauga River Basin. Although the Division would not ordinarily permit a single-family residence as an individual NPDES permit, this temporary exception is issued pending renewal of General Permit NCG550000. When/if transferred to a Certificate of Coverage under NCG550000, its expiration will be re -dated to reflect renewal of the General Permit. This single-family residence (SFR) discharge is hereby assigned secondary permit limits and monitoring frequencies as: • BOD 5-day, (30 mg/L Monthly Average; 45 mg/L Daily Maximum); • Total Suspended Solids (30 mg/L Monthly Average; 45 mg/L Daily Maximum); • Fecal Coliform (200 m1/L and 400m1/L); • Total Residual Chlorine (TRC), not -to -exceed 50 ug/L [if used as backup to proposed UV disinfection; see permit Section A. (1.)] and • pH. The Permittee is governed by the permit and Authorization to Construct (ATC) based on DWQ's review and approval of plans and specifications submitted by a North Carolina -Certified Engineer. This permit requires response in the form of an Engineer's Certification, and the Permittee's regular operation, maintenance, and record -keeping in compliance with North Carolina surface water -quality Standards, as specified in the ATC. PROPOSED SCHEDULE FOR PERMIT ISSUANCE: Draft Permit to Public Notice: July 27, 2013 Permit Scheduled to Issue: September 23, 2013 STATE CONTACT: If you have any questions on any of the above information or on the attached permit, please contact Joe R. Corporon at (919) 807-6394. PERMIT WRITER: DATE: NORTH CAROLINA FORSYTH COUNTY AFFIDAVIT OF PUBLICATION Before the undersigned, a Notary Public of said County and State, duly commissioned, qualified, and authorized by law to administer oaths, personally appeared D.H. Stanfield, who being duly sworn, deposes and says: that he is Controller of the Winston-Salem Journal, engaged in the publishing of a newspaper known as the Winston-Salem Journal, published, issued and entered as second class mail in the City of Winston-Salem, in said County and State: that he is authorized to make this affidavit and sworn statement: that the notice or other legal advertisement, a true copy of which is attached hereto, was published in the Winston-Salem Journal on the following dates: August 2, 2013 and that the said newspaper in which such notice, paper document, or legal advertisement was published was, at the time of each and every such publication, a newspaper meeting all the requirements and qualifications of Section 1-597 of the General Statutes of North Carolina and was a qualified newspaper within the meaning of Section 1-597 of the General Statutes of North Carolina. This 2nd day of August, 2013 (signature df pe �ji' making affidavit) Sworn to and subscribed before me, this 2nd day of August, 2013 My Commission expires: September 28, 2015 KIMALEY JOHNSON NOTARY PUBLIC FORSYTH COUNTY STATE OF NORTH CARQQLI A MY COMMISSION EXPIRE ai1 ' :'-(T5C(&0` PUBLIC NOTICE North Carolina Environmental Management Commisslon/NPDES Unit 1617 Mail Service Center Raleigh NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit The North Carolina Environmental Management Commission proposes to issue a NPDES wastewa- ter discharge permit to the person(s) listed below. Written comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. The Director of the NC Division of Water Quality (DWQ) may hold a public hearing should there be a significant degree of public in- terest. Please mail comments and/or information requests to DWQ at the above address. Interested persons may visit the DWQ at 512 N. Salisbury Street, Raleigh, NC to review information on file. Additional information on NPDES permits and this notice may be found on our website: http://por tal.ncdenr.org/web/wq/swp/ps/npdes/calendar, or by calling (919) 807-6390. David P letta 201 Crest ch Court Raleigh) alitilfed o isc arge treated o-omestic wastewater from a single- family residence, 4178 Hwy 421 N, Vilas, Watauga County. WSJ: August 2, 2013 US 32rp1 SA' >42 B00/7E VICINITY MAP - NOT TO SCALE PROJECT: David Paletta Residence at: 4178 Hwy. 421N Vilas, NC 28692 DESCRIPTION: Direct Discharge Wastewater Treatment System for up to 4 Bedroom House Submittal: 6-07-13 SI' n�111111 LASH ENGINEERING Consulting Civil Engineer/Planner 1104 Cindy Carr Drive Matthe+vs, N.C. 28105 Phone: 704/847-3031 emati: mikeltDlashengineering.com Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1 104 Cindy Carr Drive Matthews, NC 28105 Phone: 704-847-3031 mikelaLashEngineering.com Lash Engineering, Inc. David Paletta Wastewater System Direct Discharge, NC.DWQ Application Submittal Table of Contents 1. Cover Sheet 2. Basic Site Plan 3. Paletta Transmittal 4. Paletta Request Letter 5. Engineer's Project Summary 6. Authorization from Mr.Paletta to begin process 7. Copy of Checks for Permit ($860.00) 8. Application 9. Setback Variance Letter 10. UV Light Letter 11. UV Light Specification (Cutsheet) 12. UV Light Headloss Calculation 13. Gould Pump (Cutsheet) 14. Town of Boone, Available Sewer — email 15. Boone Map of Public Sewer 16. Watershed Classification (email from State) 17. Lash Engineering as Authorized Designer (Septitech) 18.Appalachian District Health Dept.) for Repair of Existing System 19. Paletta USGS Topo Map Also: 3 Sets of Plans and original checks are included in this submittal. ra i NMI —JOf0 ` RIR / / / / An. ?JO'Rad 19. 09' N 62V, (5£ Renaa/i?g Ph3vdriy o Wallace R. Cook Boa of Rectvv's 1Gti9 ,' at Pope? 101 // // N /1?t.25r 1820' n \ 1 i N 2171152A1 1.55.9,1' tb 1 V LJO2p - _ S777 viezz �-; 42---- .\ 20� RAv- ofpo o/f ��-1--nYLii�e - - \ ...... \ /f,,,sr�"- \ _ T•-7 / / / / // / / /J�6os ice �a eta aek o0 4p P 2' air p�a 9e � ne 1 '3. s,�`ya David Paletta Residence at: 4178 Hwy. 421 N Vilas, NC 28692 `Awe Wallac Boat of. Of / •� allacf of AI mal TRANSMITTAL Date: June 5, 2013 LASH ENGINEERING Attention of: Joe Corporon Consulting Engineers -� Civil, Planning, Wastewater Company: NPDES-DWQ 1104 Cindy Carr Drive Matthews, NC 28105 From: Michael Lash, PE. Phone: 704-847-3031 mikel(c�lashenoineering.com Project: Dave Paletts - Wastewater Application • Special Instructions: AMA non MIN Please find enclosed for the initial review are the following: 1. 3 sets of plans 2. An Application Fee check for $660.00 (Individual Permit) and an additional of $200 for $860.00 total. 3. Email showing Approval by Septitech (Pretreat Manufacturer-TS II with UV and Denite). 4. 1 original set and 2 copies of the submittal package. Thank you for the assistance that you have provided with this project. If you have any questions, please call me at: 704-847-3031. Thanks, Michael Lash, Me Lash Engineering, Inc. Lash Engineering, Inc. CivilConsulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews, NC 28105 Phone: 704-847-3031 mikel@LashEngineering.com Project Summary for:• zQ� "SEAL " Paletta 4178 Hwy.#421 North r 428;no 1 Town of Vilas, NC. ''y40,�`�C#1140, 0i AEL W • 0\` The project is located at 4178 Hwy.#421 North, NC close to the town Or'ilas, NC. in Watauga County. There is one home existing for this system. The existing 3 bedroom home is owned by Dave Paletta. There is a house on the right side of this residence that shares the use of the water well. This is shown on the plan. A direct discharge system for the wastewater effluent was proposed because of the failure of the existing system (many years old) and the lack of adequate available soils either on or offsite. The Watershed Classification for this Area is "C", Brushy Fork. The system will consist of a new 1,000 gal septic tank, a new Septitech PreTreat unit, and an Ultraviolet disinfection unit inside the Septitech unit to sterilize the effluent before it is discharged into the lake. The Septitech effluent pump is adequate for this discharge. There is no need for a pump tank. A copy of the Health Department's findings is included in this application. They have determined that there are no available onsite soils. The neighbor (with better (but not good soil) is unwilling to grant an easement. The local Health Department has granted a Repair Permit so that a system can be permitted and put into service. The Health Department (Alan McKinney) has indicated that his preference is a diredt discharge. After reviewing the site, I feel that this is the appropriate decision. Karen Wallace (Regional Soil Scientist) has also indicated her preference for a direct discharge. The proposed system will be designed for 4 bedrooms each at 120 gallons per day. This will give a total flow of 480 gallons per day. The system will utilize a proposed 1,000 gallon septic tank and a proposed Septitech unit (M400D-UV- fibreglass) with a UV light for the removal of pathogens. A cleanout is also proposed at the exit of the effluent pipe to assist with cleaning. The UV light is located on the discharge side of the Septitech unit so the treated effluent is passing through the light. The UV light is the last stage the effluent passes prior to being . discharged. The head losses of the effluent passing through the UV light are very minor (negligible). I have included these calculations. Should the UV light fail to operate, a voltage signal is sent to the control panel and the system is shut down until the light is operational. This protects the side ditch against the possibility of treated effluent that has not had the pathogens killed from entering the ditch system. The system utilizes a Septitech Control Panel that has been designed to work for this unit. The panel is housed within a NEMA 4X enclosure that is setup for the floats, pumps and internal monitoring of the system. A programmable micro -logic controller (PLC) activates the recirculation and discharge pumps through a program that self -adjusts these operations based on actual wastewater flow into the ,., processor (as monitored by the PLC). The processor constantly evaluates the water usage and meters out the effluent discharge to the disposal area at the appropriate interval to assure proper effluent treatment. M, The proposed septic tank is made of precast concrete and the proposed Septitech unit is made of fiberglass. Floatation of the tank is not a factor as the unit is being installed in Paletta's front yard approximately 6' above the highway. FIR MI rar► Iral SR emoi In Ile Lash Engineering, Inc. June 7, 2013 - Joe Corporon NPDES Permitting Program Division of Water Quality •, Raleigh, NC. 27699-1617 Re: Paletta Property, Watauga County Letter of Authorization Gentlemen: Lash Engineering, Inc. Civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews, NC 28105 Phone: 704-847-3031 mikel@LashEngineering.com w• I have engaged Michael Lash, PE. With Lash Engineering, Inc. to assist me in preparing and filing a National Pollution Discharge Elimination System application for the above captioned "" single family lot. This letter will serve to certify that I have designated him as my authorized representative for this application. Very truly yours, c-RGLizEL, we David Paletta MEM NMI NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit INCOO 'X't/ l/ 2, If you are completing this form in computer use the TAB key or the up - down arrows to moue from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address David Paletta Paletta WWTP 8201 S. Crestwyck Court Raleigh NC 27615 (919) 491-5643 (N/A) dp2nc@yahoo.com 2. Location of facility producing discharge: Check here if same address as above El Street Address or State Road 4178 Highway 421 N City State / Zip Code County 3. Operator Information: Vilas NC 28692 Watauga Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address David Paletta 8201 S. Crestwyck Court Raleigh NC 27615 (919) 491-5643 (N/A) dp2nc@yahoo.com 1 of 3 Form-D 11/12 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: ,.� Facility Generating Wastewater(check all that apply): Industrial 0 Number of Employees FM Commercial 0 Number of Employees Residential ® Number of Homes School 0 Number of Students/Staff lzgl Other ❑ Explain: 1 Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): Residential 100% - Up to 4 Bedroom House at 480gpd pal Number of persons served: 4 bedrooms 5. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 1 Is the outfall equipped with a diffuser? 0 Yes ® No 7. Name of receiving stream(s) (NEW applicants: Provide a map showing the exact location of each outfall): Side Ditch of Hwy. #321 / 421 8. Frequency of Discharge: ® Continuous ❑ Intermittent ram, If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. An existing 1,000 gallon septic tank is capable of handling 480 gallons per day. The Septitech Unit will be installed with the Ultra Violet disinfectant light and a pump capable of handling the 7 feet of pressure head needed for direct discharge to the side ditch. The Septitech Unit is designated as an M400D-UV. 2 of 3 Form-D 11 /12 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.00048 (480 gpd) MGD Annual Average daily flow 0.1752 (480*365/1,000,000) MGD (for the previous 3 years) Maximum daily flow 0.00048 (480 gpd) MGD (for the previous 3 years) 11. Is this facility located on Indian country? �, ❑ Yes ® No 011111, 12. Effluent Data - TS II Treatment NEW APPLICANTS: Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the past 36 months for parameters currently in your permit. Mark other parameters "N/A". Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) 10 mg/L Fecal Coliform 400 colonies/ 100m1 Total Suspended Solids 10 mg/L Temperature (Summer) N/A Temperature (Winter) N/A pH N/A 13. List all permits, construction approvals and/or applications: Type Permit Number Type Hazardous Waste (RCRA) N/A UIC (SDWA) N/A NPDES N/A PSD (CAA) N/A Non -attainment program (CAA) N/A 14. APPLICANT CERTIFICATION Permit Number NESHAPS (CAA) N/A Ocean Dumping (MPRSA) N/A Dredge or fill (Section 404 or CWA) N/A Other N/A I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. 7) RV/ D PRL.'✓ ( A Owner Printed name of Person Signing Title ` n Vc Q.M �/ al. 6ky(i3 Signature of Applicant Date North Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form-D 11/12 Lash Engineering, Inc. • June 7, 2013 • Joe Corporon NPDES Permitting Program Division of Water Quality • Raleigh, NC. 27699-1617 Re: Paletta Property Setback Requirements Lash Engineering, Inc. civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews, NC 28105 Phone: 704-847-3031 mikel@LashEngineering.com • This site is located along Highway 421N, approximately 1.2 miles west of Boone, NC in Watauga County. The existing house has an ancient septic system that has failed and through the years there were lot lines established that placed the existing disposal system off property. The lot goes uphill from the • highway. The land above the house (away from the highway) is fill dirt. The soil below the house (toward the highway) is very poor. The owner has not been able to obtain an easement from the neighbor to put a septic system in to the west of the property. The land to the east of the property is mostly fill dirt, • except near the highway. • NM • • • En There is an existing ditch along the highway in front of the property; with a NC.DOT maintainable right of way to the top of side ditch. We included a 5' property line offset from this line. Alan McKinney and Karen Wallace have both reviewed the site and have requested that a direct discharge permit be requested. He has indicated his support for the water well setback to be reduced to 50' so that the system can be placed on the property in close proximity to the side ditch outfall. It appears from our site visit that a direct discharge system is the best option. 1 have located the new wastewater system in the front yard; outside of the right of way and the requested setback from the existing water well. The effluent will be pumped uphill and discharged directly into the existing grassed ditch where it will travel roughly 100' before being collected into the existing driveway culvert and conveyed to an existing storm drainage drop inlet and routed to a ditch across the highway. If I can be of any further service, please do not hesitate to call. Sincerely, Michael Lash, PE. PM • L Lash Engineering, Inc. June 5, 2013 Joe Corporon NPDES Permitting Program Division of Water Quality Raleigh, NC. 27699-1617 - Re: Paletta Property UV Light Analysis Lash Engineering, Inc. civil/Consulting/Wastewater/Planning 1104 Cindy Carr Drive Matthews, NC 28105 Phone: 704-847-3031 mikel@LashEngineering.com UV lights of a low flow nature are typically a low pressure type, short wave, mercury vapor discharge tube that produces ultraviolet wavelengths lethal to microorganisms. The low pressure allows the units to run with less power and thereby generating less heat for longer life of the bulbs. The Emperor Aquatics UV "High Output" Light has been specified for this project. The spectrum of UV light that is lethal is called UV-C. This includes a wavelength range within 240- 280 nm. A wavelength around 254 to 264 is considered ideal. This lamp is set to 254 nm. Different microorganisms are extinguished at different doses. The larger "pests" take longer. Fecal Coliforms are extinguished at near 6600 µWs/cm. This lamp has a range up to 30,000 µWs/cm. Although there is a wide spectrum of bacteria, viruses and protozoa, most of the "pests" are extinguished between 2,000 and 20,000. Having a range up to 30,000 µWs/cm, assures that the germicidal action is most effective across this wide range. For this application, fecal coliforms are • most important, which have a dose requirement of about 6600 µWs/cm. This is well within range. The glass plays an important function in the effectiveness of the lamp in that the glass can absorb the UV-C wavelength. The hard quartz glass is most effective and is utilized in the "high output" unit. An additional coating "L" is added to the glass that adds resistance to "solarization" so that the bulb remains highly effective for longer periods. The Emperor Smart HQ UV Light has been submitted for review because of its ability to be installed ,., in the vertical or horizontal position. It clearly has the UV qualifications to be effective. The requirements for vertical placement are spelled out in the installation guidelines with a warning to insure the power head is above the water line. The power unit cannot be submerged. This note has been added to the plans. This unit is acceptable for use in this application and is accepted for use on this project. Sincerely, Michael Lash, PE. Sofa,;. Wir.tewater Prablemi with 'Trani) kw ULTRAVIOLET DISIFECTION SYSTEM System Description SeptiTech has made a recent change in the preferred manufacturer of ultraviolet (UV) disinfection system for use in systems that require disinfection prior to discharge. The reason for the recent change is that the manufacturer of the UV unit previously used (Siemens Sunlight Systems UV) has been discontinued by the manufacturer and is no longer available. Therefore, SeptiTech has chose to use the Emperor Aquatics Smart High Output UV Sterilizer model 025050/50. This unit is rated at the following specifications: Water Flow Rate: Ouput: Operating pressure: Voltage: No. Lamps / Watts: 1,560 —1,980 gph (26 — 33 gpm) 30,000 µWs/cm2 20 psi 120 VAC @ 60Hz 1 lamp @ 50 watts The UV unit is rated for 26-33 gpm at 20 psi operating pressure. SeptiTech will provide a flow restrictor and pressure regulator on the discharge of the pump in order to ensure that the operating parameters and not exceeded during operation. A technical cut sheet, installation guide and operation and maintenance manual from the manufacturer have been provided as part of this memo. Control and Alarm The operation of the UV unit is the same as it was previously for the Siemens Sunlight Systems product. The control panel is outfitted to provide power to the UV unit along with a current sensor. Power to the UV unit is on all the time as long as power to the control panel is provided. The current sensor is used to detect that current is being drawn from the UV bulb. If the bulb was to fail to operate, current would no longer flow to the bulb, and an alarm would be triggered at the control panel as the current sensor would no longer detect current flow. RIR Frictional Losses Frictional losses through the UV unit are minimal since the UV chamber is larger than the discharge piping used with the discharge assembly. The UV unit has 2-inch inlets and a 5-inch chamber. Based on calculations using factors from Cameron Hydraulic Data handbook, the total frictional head loss assuming a flow rate of 30 gpm is 0.00856 ft (assumed to be negligible). Head loss calculations are attached. ATTACHMENT A: Technical Cut Sheet ATTACHMENT B: Installation and Operation & Maintenance Manual ATTACHMENT C: Friction Loss Calculations Fog NMI WO Section Three UV Equipment Applications: Fish Culture Live Seafood Holding Systems o Aquarium/Exhibits • ItAarnmal/Reptile/Avian Bathing Pools Water Features Fllnctic:irs: , Clarification (Waterborne Algae Control) • Harmful Pathogen Disinfectant Ozone Destruction SiiRTllVPerlormanco Pcv0,71, /r1q&i -i rlt.l lit, 4�"'.!1'Ef�S?i: ? s^,:iar(=h Pt Aquacultu e SMART UV...The Professional's Choice! More animal husbandry and aquatic professionals choose SMART UVs over competing UV brands because of our substantiated performance information, effective product design and overall quality. With over thirty models to choose from, Emperor Aquatics, Inc. has the right SMART UV to fit your application. Size —Our SMART UV design always considers the lamp's UV C output and length, while most competitors ignore these critical performance factors. This ▪ explains why, in most cases, our equipment is physically larger. RON AMP YA�..I( 11 Iiiir. {. ,;itrlr• ft 111 I.iili( \ .'�i:,l • )icln h G+ h .l i, ,':Hu.v.;tn ijai 1 .'ii: ;F 91t1<'t • Models shown with '" optional mounting damps SWARTINSterilizer s T ° Sterilizer SWING UV Sterilizer Lamp Position — Our lamps are always positioned entirely between the inlet and outlet water ports, utilizing the lamp's full arc length to its maximum potential. Lamp Life — Long -Lasting GPH/T5 (Low-Pressure/Standard-Output) & T5 (Low Pressure/High-Output) UV lamps offer 9,000 hours of continual operation equals >80% efficiency at end of lamp life. These lamps use a specially coated "L" type hard quartz glass that extends the life of the lamp while preventing the build-up of nitrogen by-products (scaling) on the lamp's outer surface (Scaling diminishes UV C transmit- tance). These nitrogen by-products are a problem commonly associated with ozone producing "VH" type glass UV lamps. Water Flow Rates — SMART UV flow rates represent the equipment's true capacity, which considers the lamp's UV-C output, lamp length, exposure chamber's inside diameter, and UV transmissibility for specified UV dosages as per our specification charts. j$1,1I!,t ! ,•1oJi I iFLI 1 t `\•' It IlA!.';J..IV iii;f ,,11 1 , 1;;litn .ff� �;r: . bit„jl ,Ia. Y.:.y,'i(l1 [ul, 1:�. If V,,�" 1 , la1(ij i' t;+tto(•I .SiU1e! lf�d:;. 1:-:' ' 1 (iadjaj ,lei+ I t^iel i11 1-r.:Ii. ,.1[.t •-7PL Iil �1r1±<! _ : 'rN I1,. ,; 1 I-. i '::y.i .a1.::.i l _ .•.lei, t h ,t, I;l i a't-! 2F NMI www.erperaraquarics,com 14 *1 NMI Section I hree SMANTUVLite rL Models for Small Ponds, Aquariums, Model No. /Watts Maximum Maximum Pond Size Aquarium Size and Research Applications Water Flow Rate Water Flow Rate No. Algae & Bacteria Protozoa • UV-C Lamps 30,000 pWs/cm2 - 180,000 pWs/cm2 Input Output Dim. /Watt Suggested/Maximum Suggested/Maximum Watts Watts (Inches) Inlet /Outlet Input Voltage 02218/18 02225/25 02240/40 02280/80 1,100 Gal. 1,700 Gal. 2,900 Gal. 5,900 Gal. 60 Gal. 90 Gal. - 160 Gal. 330 Gal. 1/18 • 1/25 1/40 2/40 219 GPH/356 GPH 332 GPH/554 GPH 589 GPH/983 GPH 1,178 GPH/1,967 GPH 37 GPH/60 GPH 18 55 GPH/92 GPH 25 98 GPH/164 GPH 40 196 GPH/328 GPH 80 5 21,75"x 2.5" 1.5' Union 120VAC 50/60Hz 8 • 29,75" x 2.5" 1.5" Union 120VAC 50/60Hz 14 44.75" Z2.5" ---1.5" Union 120VAC 50/60Hz 28 44.75"x 14" 1.5" Union 120VAC 50/60Hz it} Indicates popular models Also Available with Quara Sleeve Wipers SINIMMISterilizer :t" rliairiet*r Housing, Models -for Moderately Sized Ponds, Aquariums, and Exhibit/Research Applications Model No. /Watts 02025/25 02040/40 02065/65 02080/80 02130/130 FM. PIM PM. Maximum Maximum Pond Size Aquarium Size Water Flow Rate _.. - Water Flow Rate _ No. Algae & Bacteria Protozoa - - UV-C Lamps 30,000 pWs/cm.2 - • 180,000 pWs/cm2 Input Output Dim, /Watt Suggested/Maximum Suggested/Maximum Watts Watts (Inches) 2,400 Gal. 130 Gal. 1.25 472 GPH/788 GPH 79 GPH/131 GPH 25 8 29- x 35' 4,700 Gal. 260 Gal. 1/40 943 GPH/1,574 GPH 157 GPH/262 GPH _ _ 40 14 43.75"x 35" 8,600.Gal.-- - 480 Gal. 1/65 1,710 GPH/2,855 GPH 285 GPH/476 GPH '65 - • . 25 705" x 35' --9:400 Gal. 530 Gal. 2/40 1,885 GPH/3,148 GPH 314 GPH/525 GPH 80 28. 44.5 Lx.15.5" 17,100 Gal. 960 Gal. 2/65 3,420 GPH/5,711 GPH 570 GPH/952 GPH 130 50 71.5" x15.5- 15" Union g.t- Indicates popular models Also Avallable with Quartz Sleeve Wipers SKIBT110 UVSterillzer Models for Large Ornamental Ponds, Water Features, and Exhibit/Research/Aquaculture Applications Model No. /Watts 025050/50 025080/80 025120/120 025150/150 Maximum Maximum Pond Size Aquarium Size 5,900 Gal. 10,800 Gal. 13,800 Gal. 19,100 Gal. 330 Gal. 600 Gal. 770 Gal. 1,060 Gal. No. Lamps /Watt Water Flow Rate Algae & Bacteria 30,000 pWs/cm2 Suggested/Maximum 1/50 1,560 GPH/1,980 GPH 1/80 2,700 GPH/3,600 GPH 1/120 3,840 GPH/4,600 GPH 1/150 5,040 GPH/6,360 GPH Water Flow Rate Protozoa UV-C 180,000 pWs/cm2 Input Output Dim. Suggested/Maximum Watts Watts (Inches) 260 GPH/330 GPH 450 GPH/600 GPH 640 GPH/767 GPH 840 GPH/1,060 GPH 50 80 120 150 16 26 36 47 28" x5.75" 43" x 5.75" 56" x 5.75" 70" x 5.75" 0 Indicates popular models Also Available with Quartz Sleeve Wipers SMITH') AIL eti Sterilizer' .cf.,E1 Models for Large Ornamental Ponds, Water Features, and Exhibit/Research/Aquaculture Applications Model No. /Watts Maximum Maximum Pond Size Aquarium Size • No. Lamps /Watt Water Flow Rate Algae & Bacteria 30,000 pWs/cm2 Suggested/Maximum Water Flow Rate Protozoa UV-C 180,000 pWs/cm2 Input Output Dim. Suggested/Maximum Watts Watts (Inches Adapter Fittings are not included Inlet /Outlet Input Voltage 1.5" Union 120VAC 50/60Hz 13° Union 120VAC 50/60Hz 13" Union 120VAC 50/60Hz 1.5" Union 120VAC 50/60Hz 120VAC 50/60Hz All models Include Adapter Fittings Inlet /Outlet 2'Union 2" Union 2" Union 2" Union Input Voltage 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz Adapter Fittings are not include Inlet /Outlet Amps Max Load @ 120/230 VAC 0250100/100 0250160/160 0250240/240 0250300/300 7,700 Gal. 16,200 Gal. 21,800 Gal. 36,000 Gal. 430 Gal. 900 Gal. 1,210 Gal. 2,000 Gal. 2/50 2,040 GPH/2,580 GPH 2/80. 4,320 GPH/5,400 GPH 2/120 5,820 GPH/7,260 GPH 2/150 9,600 GPH/12,000 GPH 340 GPH/430 GPH 720 GPH/900 GPFI 970 GPH/1,210 GPH 1,600 GPH/2,000 GPH 100 160 240 300 26 37'' x 11° 3" Union 52 54" x 11" 3" Union 70 66" x 11° 3" Union 110 80° x11" 3" Union 1.15/0.5 1.15/05 1.15/05 1.85/0.85 Water Flow Rates are based on: 90% UV Transmissibility Suggested = UV Lamp @ 80% efficiency (after 9,000 hours of continuous operation) Maximum = UV Lamp Power @ 100% efficienq (new condition) Input Voltage on all models = 120/230VAC 50/60Hz Aquarium & Fond Sizing is based on: Maximum Aquarium = single pass/1 hour @ "Maximum" flow rate for Protozoa Maximum Pond = single pass/3 hours @ "Maximum" flow rate for Algae & Bacteria 0015 wwW.rArtirleror;4t1t ia 1 irs.corri EMPEROR AQUATICS, wo• Sterilizers NM PIM 1111.111 NMI NMI OPERATING AND SERVICE INSTRUCTIONS ITEM #02934-INS-SMARTUV iv : �' ` H■i<�h Out ut T. U Sterilizer- .. ,y � TUiSterilizer Tillhire- 1000 EMPEROR AQUATICS, INC:" www.emperoraquatics.com Mil MINN Hi Out ut SMART�lite ISMRT�Sterifizer /SMART ISteriiizer OPERATING AND SERVICE INSTRUCTIONS Congratulations on the purchase of your new SMART UV, we want you to be safe and successful with our equipment so please, read our instructions prior to installing and operating this equipment! Section One: SAFETY RULES FOR ALL SMART UV MODELS - pg. 1- 2 Section Two: UV STERILIZATION FEATURES AND SPECIFICATIONS - pg. 2 - 5 Section Three: WHAT IS ULTRAVIOLET STERILIZATION - pg. 6 Section Four: PRE -INSTALLATION INSPECTION - pg. 6 - 8 ., Section Five: QUARTZ SLEEVE/UV LAMP INSPECTION - pg. 9 - 11 Section Six: THE QUARTZ SLEEVE ASSEMBLY - pg. 11 - 13 • Section Ten: UV LAMP INSTALLATION- pg. 16 - 17 Section Seven: MOUNTING YOUR SMART UV - pg. 13 - 14 Section Eight: MANDATORY SMART UV WATER TESTING - pg. 14 - 15 Section Nine: ELECTRICAL REQUIREMENTS - pg. 15 - 16 IMPOR'I,ANT! Must Read! till Section Eleven: QUARTZ SLEEVE WIPERS - pg. 17 - 19 Section Twelve: SMART UV INSTALLATION/OPERATION - pg. 20 - 25 Section Thirteen: SMART UV WINTERIZING - pg. 26 Section Fourteen: SMART UV MAINTENANCE - pg. 26 - 27 Section Fifteen: SMART UV REPLACEMENT PARTS - pg. 28 - 31 Section Sixteen: TROUBLESHOOTING - pg. 32 Section Seventeen: CONTACT INFO - pg. 32 active tlghdrq lfype SY�111 Sclencel Warranty - pg. 33 Other Emperor Aquatics, Inc. Products - pg. 34 - 35 For pond calculating measurements and essential water quality parameters please visit us at: www.emperoraquatics.com Section One: SAFETY RULES FOR ALL SMART UV MODELS Ing R IMPORTANT SAFETY INSTRUCTIONS PLEASE READ PRIOR TO INSTALLATION AND OPERATION WARNING TO GUARD AGAINST INJURY. BASIC SAFETY PRECAUTIONS SHOULD BE OBSERVED. INCLUDING THE FOLLOWING: Water and electricity can be a dangerous combination. Help us ensure your safety PLEASE READ AND FOLLOW ALL SAFETY INSTRUCTIONS. DANGER: WARNING -Ultraviolet light is damaging to your eyes and skin! fowl Do not handle or stare at an operating UV Tamp. Note that the UV Tight rays are invisible to the human eye and precautions should be taken to prevent UV energy from entering the eyes. 1.1 IMPORTANT: READ AND OBSERVE ALL IMPORTANT NOTICES AND LABELS ON THE UNIT. IMPORTANT: For Your Safety - The quartz sleeve and or the UV Tamp in this product may have been broken or damaged during transit! It is therefore ESSENTIAL that the unit be CAREFULLY INSPECTED BEFORE CONNECTING TO ELECTRIC POWER (See Section Five) WARNING: Do NOT exceed 20 PSI (Pounds Per Square Inch) DANGER: To avoid possible electric shock, special care should be taken since water is employed in the use of this aquarium and pond equipment. For each of the following situations, do not attempt repairs yourself. Call EMPEROR AQUATICS, Inc. customer service department at 610-970-0440 Ext. 0 for services or discard the appliance. DANGER: If the unit falls into the water, DO NOT REACH FOR ITT First unplug it and then retrieve it. If the internal electrical components of the unit get wet, unplug the unit immediately. DANGER: If the unit shows any sign of water leakage, immediately unplug it from 1.1 the power source. IMPORTANT: Carefully examine the unit after installation. It should not be plugged in if there is water on any part not intended to be wet. DANGER: Do not operate this unit if it has a damaged cord or plug, if it is mal- functioning, or if it has been dropped or damaged in any manner. 1 IMPORTANT: Close supervision is necessary when any appliance is used by or near children, and our equipment is no exception. IMPORTANT: Always unplug the unit from an electrical outlet when not in use, before servicing, cleaning or removing parts. Never yank the cord to pull the plug from the outlet. Grasp the plug and pull to disconnect. - IMPORTANT: SMART UVs are designed for low-pressure water applications with or without aquatic livestock. DO NOT use the EMPEROR AQUATICS, Inc. SMART UV for any application other than its intended use. The use of attachments not recommended or sold by Emperor Aquatics Inc. may cause unsafe conditions and possibly void any warranty. IMPORTANT: This unit must be wired in conjunction with a properly grounded, ground fault interrupter circuit (GFI). Only (3) three wire grounded cables suitable for outdoor use should be used to connect this unit. If joining cables for outdoor use, a suitable watertight cable connector must be used. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance's rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. (If in doubt consult a qualified electrician) Section Two: UV STERILIZATION FEATURES AND SPECIFICATIONS Our GPH T 5 and T-6 low pressure mercury vapor germicidal lamps, convert approximately 40% of their electrical input watts into UV-C output watts within the germicidal action spectrum (meaning 40% of electricity used is converted into use- ful germicidal UV light), the highest UV-C output conversion among all UV lamps. SMART UV FEATURES • UL listed for indoor and outdoor use, fresh and salt water use. • Long lasting GPH/T5 and GPH/T6 UV lamps (9,000 hours to 80% efficiency). • Protective Quartz Sleeve (maximizes UV lamp output and safety) • Watertight Design • Easy -to -Remove Power Assembly • Remote Power Supply • UV Resistant High Density Plastic UV Housing (Lifetime warranty against UV degradation) i� C n7 K `a: pti y a • Utilizes the UV Tamp to its maximum potential SMART UV (maximum UV exposure) Specifications Charts • Non -UV Transmitting Clear Lamp Viewing Ports (See pages 3, 4, and 5) 1 1 1 1 1 1 itfteg 01 SMART High -Output UV Sterilizer Models HihQutut SUsteriiizor MART � Model No. /Watts 025050/50 025080/80 025120/120 025150/150 025050-W/50 025080-W/80 025120-W/120 025150-W/150 Maximum Maximum Pond Size Aquarium Size 5,900 Gal. 10,800 Gal. 13,800 Gal_ 19,000 Gal. 5,900 Gal. 10,800 Gal. 13,800 Gal. 19,000 Gal. 500 Gal. 900 Gal. 1,200 Gal. 1,600 Gal. 500 Gal. 900 Gal. 1,200 Gal. 1,600 Gal. Water Flow Rate No. Algae & Bacteria Lamps 30,000 pWs/cm2 /Watt Suggested/Maximum Water Flow Rate Protozoa 90,000 pWs/cm Suggested/Maximum UV-C Input Output Dim. Inlet Watts Watts (Inches) /Outlet Input Voltage 1/50 1/80 1/120 1/150 1/50 1/80 1/120 1/150 1,560 GPH/1,980 GPH 2,700 GPH/3,600 GPH 3,840 GPH/4,600 GPH 5,040 GPH/6,360 GPH 1,560 GPH/1,980 GPH 2,700 GPH/3,600 GPH 3,840 GPH/4,600 GPH 5,040 GPH/6,360 GPH 540 GPH/720 GPH 900GPH/1,200 GPH 1,260 GPH/1,560 GPH 1,680 GPH/2,100 GPH 540 GPH/720 GPH 900 GPH/1,200 GPH 1,260 GPH/1,560 GPH 1,680 GPH/2,100 GPH 50 80 120 150 50 80 120 150 16 26 36 47 16 26 36 47 28" x 5.75" 43" x 5.75" 56" x 5.75" 70" x 5.75" 28" x 5.75" 43" x 5.75" 56" x 5.75" 70" x 5.75" 2" Union 2" Union 2" Union 2" Union 2" Union 2" Union 2" Union 2°' Union 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz 120VAC 50/60Hz WARNING: Do NOT exceed 20 PSI (Pounds Per Square Inch) Note: PVC Adapter Kits not included (but available separately) "Suggested" Water Flow Rates are based on UV Lamp End of Useful Lamp Life, 9,000 hrs. @ 80% output. Maximum Water Flow Rates are based on New Lamp Condition. All water flow rates incorporate a 90% UV transmittance factor, considering "Green Water" conditions. EMPEROR AQUATICS, INC. SMART HO UV filEi.ZP.IZERS EXPLODED PARTS VIEW DIAGRAM FOR MODEL #'s 025050, 025080, 025120, & 025150 UV STERILIZERS & FOR MODEL #'s 025050-W, 025080-W, 025120-W, & 025150-W UV STERILIZERS �1 JJ--- r 1. UV Lamp 2. 4-Pin Lamp Connector 3. Black Power Supply Jamb Nut 4. Gray Power Supply Adapter 5. Power Supply Cord 6. Power Supply Module Assembly 7. Black Retaining Nut 8. Power Supply Gasket 9. Clear Quartz Sleeve Retaining Module 10. 0-Ring for Clear Quartz Sleeve Retaining Module 11. Quartz Sleeve 0-Ring 12. Quartz Sleeve Gasket SMART I-10 UV UV Lamp Quartz Sleeve Watts/Model No. Part No. Part No. Ei 071 ■(6) L• 13. White Quartz Sleeve Gasket/O-Ring Retaining Nut 14. Quartz Sleeve 15. UV Sterilizer Housing 16. Water Inlet/Outlet Union 0-Ring 17. Water Inlet/Outlet Union Socket Half 18. Water Inlet/Outlet Union Retaining Nut 19. Quartz Sleeve Wiper Module (w/ wiper only) 20. C-Clips (w/ wiper only) 21. Quartz Sleeve Wiper Rod (w/ wiper only) 22. Wiper Rod Handle Stop Nut (w/ wiper only) 23. Wiper Rod Handle (w/ wiper only) ■ Pcwer Supply Part No. Lamp Connector Part No. Gasket Service Kit Part No. 50 Watt/025050 80 Watt/025080 120 Watt/025120 150 Watt/025150 20050 20080 200120 200150 20325 20340 203120 20365 20105/20250-1 20105/202120.1 20105/202120-1 202150-1 20077 20077 20077 20077 20375 20375 20375 20375 NOTE:ClearQuartz Sleeve Retaining Module 20603,White Quartz Sleeve Retaining Nut 20079, both fit all SMART UV Sterilizer Models a5 well as all SMART NO IN Sterilizers. 31 1 1 1 1 1 l 1 1 1 1 1 1 1 CAMERON UYDHAULIC DATA A hate&dy n e3ei'elnce on the subject of hydraulics, and steam Edited by C. C. Heald Eighteenth Edition Third Printing Price $30.00 1). Ingersoll -Dresser Pumps Liberty Corner, NJ 07938 Visit rnu• wet -mite at www.idpump.cout 1 MEI MEN IOW Note: Fittings are standard with full openings. Fitting L0 Nominal pipe size 1/2 3/4 1 1'/4 11/2 2 2/2-3 4 6 8-10 12-16 18-24 K value Butterfly Valve .-J.UL,- irir . 0.86 0.81 0.77 0.68 0.63 0.35 0.30 Plug Valve straightway 18 0.49 0.45 0.41 0.40 . 0.38 0.34 0.32 0.31 0.27 0.25 0.23 0.22 Plug Valve 3-way thru-flo 30 0.61 0.75 0.69 , 0.66 0.63 0.57 0.54 0.51 0.45 0.42 0.39 0.30 a Jag Plug Valve branch-llo 90 2.43 2.25 2.07 1.98 1.89 1.71 1.62 1.53 1.35 1.26 1.17 1.08 I 1111. l•' Standard elbow 1-1;-1 1 90' 30 0.81 0.75 0.69 0.66 0.63 0.57 0.54 0.51 0.45 0.42 0.39 0.36 ' 45° 16 0.43 0.40 0.37 0.35 0.34 0.30 0.29 0.27 0.24 0.22 0.21 0.19 long radius 16 0.43 040 0.37 0.35 0.34 0.30 0.29 0.27 0.24 0.22 0.21 0.19 Calculated from data in Crane Co., Technical Paper No. 410. Note: Fittings are standard with full openings. Fitting Type of bend L/0 Nominal pipe size 72 3/41 1'/4 15'2 2 27z-3 4 6 8-10 12-16 18-24 K value Close Return 50 1.35 1.25 1.15 1.10 1.05 0.95 0.90 ti 0.65 0.75 0.70 0.65 0.60 Standard Tee J I Ihru flo 20 0.54 0.50 0.46 0.44 0.42 .38 . 6 0.34 0.30 0.28 0.26 0.24 Ihru branch 60 1 52 1 50 1.36 1.32 1.26 1.14 .08 1.02 0.90 0.84 0.78 0.72 eniii.iinssi 90' Bends. Pipe bends, flanged elbows, butt welded elbows _ _ i I (----- d ,�:10;j �I r/d = 1 20 0.54 0.50 0.46 0.44 0.4 0.38 0.36 0.34 0.30 0.28 0.26 0.24 r/d = 2 12 0.32 0.30 0.28 0.26 0.25 0.23 0.22 0.20 0.18 0.17 0.16 0.14 r/d = 3 12 0.32 0.30 0.28 0.26 0.25 0.23 0.22 0.20 0.18 0.17 0.16 0-14 rid 4 14 0.38 0.35 0.32 0.31 0.29 0.27 0.25 0.24 0.21 0.20 0.18 0.17 rid = 6 17 0.46 0.43 0.39 0.37 0.36 0,32 0.31 0.29 0.26 0.24 0.22 0.20 rid 6 24 0.65 0.60 0.55 0.53 0.50 0.46 0.43 0.41 0.30 0.34 0.31 0.29 r/d - 10 30 0.81 0.75 0.69 0.66 0.63 0.57 0.54 0.51 0.45 0.42 0.39 0.36 rid = 12 34 0.92 0.65 0.78 0.75 0.71 0.65 0.61 0.58 0.51 0.48 0.44 0.41 r/d - 14 38 1.03 0.95 0.87 0.84 0.80 0.72 0.68 0.65 0.57 0.53 0.49 0.46 r/d = 16 42 1.13 1.05 0.97 0.92 0.88 0.80 0.76 0.71 0.63 0.59 0.55 0.50 r/d - 18 46 1.24 1.15 1,06 1.01 0.97 0.87 0.83 0.78 0.69 0.64 0,60 0.55 r/d = 20 50 1.35 1.25 1.15 1.10 1.05 0.95 0.90 0.85 0.75 0.70 0.65 0.60 Mitre Bends a = 0° 2 0.05 0.05 0.05 0.04 0.04 0.04 0.04 0.03 0.03 0.03 0.03 0.02 Calculated from data in Crane Co. Technical Paper No. 410. re 3 3 T C7 0 1t1 7 N 0 c 2 d II A aI< 03 03LIEIS!S91:1 f0 NI' raulic Data r Steel Pipe itinued) emi iedule 160-steel -.438' inside dia msr y If MIMI Ve- locity head ft Head loss It per 100 ft 91 .007 .074 4 .017 .154 .8 .030 .258 '3 .046 .387 17 .067 .540 .2 .091 .691 '7 .119 .885 1 .150 1.10 n1A 16 .185 1.34 10 .224 1.61 w 15 .267 1.89 19 .313 2.20 34 .363 2.53 IB .417 2.89 53 .475 3.28 38 .536 3.86 22 .601 4.09 57 .669 4.53 )1 .742 5.00 - 50 .897 6.00 30 1.07 7.09 99 1.25 8.27 68 1.45 9.55 37 1.67 10.9 06 1.90 12.4 75 2.14 13.9 44 2.40 15.5 13 2.68 17.3 82 2.97 19.1 52 3.27 21.0 21 3.59 22.9 90 3.92 25.0 59 4.27 27.2 28 4.64 29.5 00 5.61 35.5 74 6.67 42.1 46 7.83 49.2 19 9.08 57.0 92 10.4 65.2 .65 11.7 74.1 a .38 13.4 83.4 10 15.0 93.A .83 16.7 104 .56 18.5 115 .02 22.4 139 'oo condition of interior equirements of each safety factor of 15 to MIN 157 VIM Friction Friction of Water *New Steel Pipe (Continued) (Based on Darcy's Formula) 5 Inch Standard wt steel-sch 40 Extra strong steel-sch 80 Schedule 160-steel 5.047- ins' a dia 4.813' inside dia 4.313' inside dia Flow Head Head Head U S gal Velocity Velocity 1085 Velocity Velocity loss Velocity Velocity loss per ft per head per ft per head ft per ft per head ft per min sec It 00..ft��,��� sec ft 100 ft sec ft 100 ft 30 .451 OOpgg O AO to _II .53 .00 .030 .659 .007 .051 40 .641 ;•�re d$lj .71 .01 .051 .878 .012 .086 50 .802 .060 .88 .01 .075 1.10 .019 .128 60 .962 .083 • 1.06 .02 .105 1.32 .027 .178 70 1.12 .110 1.23 .02 .130 1.54 .037 .236 80 1.28 .026 .140 1.41 .03 .176 1.76 .048 .301 90 1.44 .032 .173 1.59 .04 .218 1.98 .061 .373 100 1.60 .040 .210 1.76 .05 .265 2.20 .075 .453 120 1.92 .058 .293 2.11 .07 .370 2.64 .109 .612 140 2.25 .078 .389 2.47 .09 .491 3.07 .147 .816 160 2.57 .102 .480 2.82 .12 .607 3.51 .192 1.05 180 2.B9 .129 .598 3.17 .16 .757 3.95 .243 1.31 200 3.21 .160 .728 3.52 .19 .922 4.39 .299 1.60 220 3.53 .193 .670 3.88 .23 1.10 4.83 .352 1.91 240 3.85 .230 1.03 4.23 .26 1.30 5.27 .431 2.25 260 4.17 .270 1.19 4.58 .33 1.51 5.71 .506 2.63 280 4.49 .313 1.37 4.94 .38 1.74 6.15 .587 3.02 300 4.81 .360 1,56 5.29 .43 1.99 6.59 .674 3.45 320 5.13 .409 1.77 5.64 .49 2.25 7.03 .766 3.91 340 5.45 .462 1.98 5.99 .56 2.52 7.47 .865 4.39 360 5.77 .516 2.21 V V V 0 01 V A O J W D7O NOUI .63 2.81 7.91 .970 4.90 380 6.09 .577 2.45 .70 3.12 8.35 1.08 5.43 400 6.41 .639 2.71 .77 3.44 8.78 1.20 6.00 420 6.74 .705 2.97 .85 3.78 9.22 1.32 6.59 440 7.06 .774 3.25 .94 4.13 9.66 1.45 7.21 460 7.38 .846 3.54 8.11 1.02 4.50 10.10 1.58 7.85 480 7.70 .921 3.84 8.46 1.11 4.08 10.5.1 1.73 8.53 500 8.02 .999 4.15 8.82 1.21 5.28 10.98 1.87 9.23 550 8.132 1.21 4.99 9.70 1.46 6.35 12.08 2.26 11.1 600 9.62 1.44 5.90 10.6 1.7 7.51 13.18 2.70 13.1 650 10.4 1.69 6.89 11. 5 - v N NNN0)t7 8.77 14.27 3.16 15.4 700 11.2 1.96 7.95 12.3 10.1 15.37 3.67 17.8 750 12.0 2.25 9.09 13.2 11.6 16.47 4.21 20.3 800 12.8 2.56 10.3 14.1 13.1 17.57 4.79 23.0 850 13.6 2.89 11.6 15.0 14.8 18.67 5.41 25.9 900 v NO N0) O N tC I� Oi 3.24 13.0 15.9 3.9 16.5 19.76 t01001t0O O 0 V O tD tD A 01 fJ 29.0 950 3.61 14.4 16.7 4.3 18.4 20.86 32.3 1000 4.00 15.9 17.6 4.8 20.3 21.96 36.7 1100 4.84 19.2 19.4 5.8 24.5 24.16 43.0 1200 5.76 22.7 21.1 6.9 29.0 26.35 51.0 1300 20.8 6.7526.6 22.9 8.2 34.0 28.55 12.65 59.8 1400 22.5 7.83 30.7 24.7 9.5 39.3 30.74 14.67 692 1500 24.1 8.99 35.2 26.4 10.8 45.0 32.94 16.84 79.2 1600 25.7 10.2 40.0 28.2 12.4 51.1 35.14 19.16 90.0 1700 27.3 11.6 45.1 30.0 14.0 57.6 37.33 21.63 101 ' Cast Iron not commercially available In this size. Note: No allowance has been made for age, difference in diameter, or any abnormal condition of interior surface. Any factor of safety must be estimated from the local conditions and the requirements of each particular installation. It is recommended that for most commercial design purposes a safety factor of 15 to 20% be added to the values in the tables -see page 3-5. 3-21 ;1 r F. F1C> L o5 $. 4-A Lc:: , T 1,-14` u ( )V f LA.) t ti'•J -T 1--Et9 .Y p..e.._a $ cJ C=' . tiLaGteI (6L 4.JtirbT'tcar.�`� 4 i....) /\l r.l Rv144r!\/ ( 4i151-)r) OF r r Sr; /9 lr 14, r ,L',47-7AM -4%.r i' Z T?! e.T. /�',[• //1fs�-%v,� $E6'J 11E. 4-/ G /r H % ..Q�/fir 41,4 1 14265 / itiii II two REIM (/ Lc( T Pu v' ..z ? f C /5 7'71' 4J5t Y•��rv+sl� i'� i +cam is t i f 7' e J // UV L(GH 1- Et" F-vcz_o+� 4 (�GT7 L. d �eP-1,,n `:r • Ii �-' ) �► S.7� e.)Ait�5 ,sue 134FAt• e Ea c.t =? k = 1, l 4. , ly ,./ e), 07.: 1-11 1 )"...!4,4 e).---e"(1/ z> 2 TE:S.-5-T•4;').494), k - ''9/i 2 ( (oo / - 6,00056 FL , `r fr+ �= K r S / �!G � cr, , 44Z— - ITT OM NMI Min MISR PEW Goulds Pumps LS P03/LS P07 LSPO3AV LSPO7 GOULDS PUMPS Goulds Pumps is a brand of ITT Residential and Commercial Water. www.goulds.com Engineered for life Wastewater Submersible Sump Pumps FEATURES • Corrosion -resistant construction. • Stainless Steel motor casing and fasteners. ■ Glass -filled thermoplastic impeller and casing. ■ Upper and lower heavy duty ball bearing construction. ■ Motor is permanently lubricated for extended service life and is powered for continuous operation. All ratings are within the working limits of the motor. • Hard coated 400 series stainless steel shaft for improved corrosion resistance. • Float switch is adjustable for various liquid levels. Easily removed for direct pump operation or switch replacement. ■ Complete unit is lightweight, portable and easy to service. ■ Available in manual and automatic ver- sions. See next page for specific order numbers. ■ A double labyrinth lip seal system pro- tects the motor. It consists of three lip seals and a V-ring in addition to an im- peller counterblade system which keeps solid particles away from the seal unit. Inn ITT APPLICATIONS Specially designed for the following uses: • Basement draining • Water transfer • Dewatering SPECIFICATIONS • Discharge size: 11" NPT. • Capacities: to 57 GPM. • Maximum head: 34 feet TDH. • Max. solids: 3/s" spherical • Temperature: 104°F (40°C) maximum liquid temperature. • Maximum pump submergence is 10 ft. for LSP03; 16 ft. for LSP07. MOTOR • Single phase, 3450 RPM, 60 Hz • LSP03, 1/3 HP 115 V, 2.9 maximum amps. • LSP07, 3/4 HP 115 V (7.1 amps) or 230 V (3.5 amps). • Built-in thermal overload protection with automatic reset. • Permanent -split -capacitor type. MODEL INFORMATION GOULDS PUMPS Wastewater • Class B insulation. • Stainless steel shaft. • Air filled design. • Power cord length: LSP03; 10 feet standard, 20 feet optional, LSP07; 20 feet. FLOAT SWITCH OPTIONS • Models are available with a float switch. Several op- tions for automatic operation. • "AV" models are supplied with a vertical float switch. • "A" models are supplied with a built in float switch. • "AT" models are supplied with a piggy -back replace- able float switch. AGENCY LISTING SA= C US Canadian Standards Assodation File #LR114251 Underwriters Laboratories Re #83318 Goulds Pumps is ISO 9001 Registered. Order No. HP Volts Amps Minimum Circuit Breaker Phase Float switch Style Cord Length Discharge Connection Min. On Level Min. off Level Minimum Basin Diameter Maximum Solids Size Shipping Weight Ibs/kg 11/5 L5P0311 ya 115 2.9 10 1 Plug / No Switch 10, 1 /2' Manual Manual 9" 3/a" LSP0311A Built -In Wide Angle 11" 5" 12" LSP0311AT Piggyback Wide Angle 11" 5" 12" ISP0311 AV Piggyback Vertical 8.5" 2° 12" LSP0311 F Plug / No Switch 20' Manual Manual 9" LSP0311AF Built -In Wide Angle 11" 5" 12" LSP0311ATF Piggyback Wide Angle 11" 5° 12° LSP0711 F 3A 115 7.1 10 1 Plug / No Switch 20' 1' ' Manual Manual 9" Y" 15 / 6.8 LSP0711AF Built -In Wide Angle 12.5" 6.5" 12" LSP0711 ATF Piggyback Wide Angle 12.5" 6.5" 12" LSP0712F 230 3.5 Plug / No Switch Manual Manual 9" LSP0712AF Built -In Wide Angle 12.5" 6.5" 12" LSP0712ATF Piggyback Wide Angle 12.5" 6.5" 12" - 4? ITT FEET 35 LSPO7 30 25 Q 20 LSPO3 15 0 f- 10 5 00 COMPONENTS 10 20 30 CAPACITY Item No. Description 1 Casing 2 Impeller 3 Suction strainer 4 Shaft seal with cover 5 Motor 6 Ball Bearing 7 Capacitor 8 0-ring 3 GOULDS PUMPS Wastewater MODEL: LSP03, LSPO7 SIZE: 3/8" SOLIDS MAX. RPM: 3450 HP: '/3and3/4 40 50 GPM AM - ITT am lin DIMENSIONS Wastewater (All dimensions are in inches and weights in Ibs. Do not use for construction purposes.) F H LSPO3 93/4 75h LSP07 11'/+ 9% LSPO3AV 93/4 75/8 POWER CORD: 16/3 SJTW WITH THREE PRONG GROUNDING PLUG 6'A" DIA. 1 2' 1'/" NPT DISCHARGE F nn n n nnn GOULDS PUMPS Goulds Pumps and the ITT Engineered Blocks Symbol are registered trademarks and tradenames of ITT Corporation. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BLSPO3 August, 2006 © 2006 ITT Corporation Engineered for life O LSPO3AV nnnnnnnni H F 12" r. EMI OM Town of Boone Department of Public Utilities June 11, 2013 To Whom It May Concern: This is in regard to the availability of public water and sanitary sewer services to property located in the Vilas NC community. Water and sanitary sewer services are not accessible to this area and the Town of Boone has no plans to expand its services there. I have included a map depicting our current system for your reference. If I can be of any further assistance please feel free to contact me at 828-268-6250 or .. josh.eller(a)townofboone.net GNI aft NO Sincerely, t4- Josh Eller Utilities Service Technician Cc; Mr. Greg Young, Town Manager Mr. Rick Miller, Director of Public Utilities foNvn of Boone Department of Public Utilities P.O. Box 192 Boone. NC 28607 \TE ti5 b (✓'F !vl � p -eS Legend 'tiCcnterlines oft... Wastewater Gravity Main tiWater Main l�! xivF, Prepared by l‘,ah Eller 6/11/13 Boone Water & Sewer 0 6001,200 2,400 3,600 4,800 Feet 1 1 1 RE: Paletta Residence mailbox:///C:/Users/Owner/AppData/Roaming/Thunderbird/Pro... MEW Subject: RE: Paletta Residence From: "Mcnees, Jamie" <jamie.mcnees@ncdenr.gov> Date: 6/10/2013 8:02 AM To: "Michael Lash, PE." <mikel@lashengineering.com> Hi Mike, Sorry, I was out of the office on Friday too. Its Brushy Fork and class C. Let me know if you need any more help! Jamie Jamie McNees Environmental Specialist Classifications & Standards Unit NC DENR Division of Water Quality Tel: (919) 807.6421 FAX: (919) 807.6497 www.ncwaterquality.org/CSU E-mail correspondence to and from this address may be subject to the NC Public Records Law and may be disclosed to third parties. From: Michael Lash, PE.[mailto:mikel@lashengineering.com] Sent: Friday, June 07, 2013 10:47 AM To: Mcnees, Jamie Subject: Paletta Residence Jamie, sent this to Adriene and it came back that she is on vacation again. I was hoping that you could look it up for me. I've included a USGS map and the coordinates are below. Here is the Northing and Easting. 36° 14' 08.71" N 81° 44' 23.58" W Thanks for your help, Mike L (_ash E igireering, Inc. Michael Lash, PE. 704-847-3031 mikes@iashengineering.com No virus found in this message. Checked by AVG - www.avg.com 1 of 2 6/11/2013 1:56 PM Tim Barbee Driller Service, Inc. — Hickory 1800 Highland Ave NE Hickory, NC 28601 March 3, 2009 Dear Mr. Barbee: I am writing this letter to inform you that Michael Lash. P.E of Lash Engineering. Inc is certified to design treatment and disposal systems using the SeptiTech, LLC line of pretreatment processors. Regards, Joshua Cobb, P.E. Design Engineer 70 Commercial Street, Suite 3 Lewiston, Me 04240 (207) 333-6940 MI MCI Fax (888) 747-7074 palettalaw@bellsouth.net www.paletta.org DAVID R. PALETTA Phone ATTORNEY AT LAW (919) 491-5643 8201 S. Crestwyck Court Raleigh, North Carolina 27615-3212 via email only to tonya.hartsog@apphealth.com November 23, 2012 '°`' Appalachian District Health Department 126 Poplar Grove Connector Boone, NC 28607 MI Re: 4178 Hwy 421 N, Vilas, NC ,., Application for a repair permit MI Dear Sir or Madam: I own a rental house at 4178 Hwy 421 N, Vilas, NC. The septic system is having some issues. I am exploring my repair options. I have enclosed an application for a repair permit. My authorized agent is pm Bobby Plemons (828) 406-0000. If you have any questions, please feel free to contact me via email or cell phone �+ (919) 491.5643. Ion PEI ruhl MI Sincerely yours, 'a.41;c0R 94.------ David R. Paletta Attorney at Law DRP/gh APPALACHIAN DISTRICT HEALTH DEPARTMENT ASHE COUNTY P.O. BOX 208 JEFFERSON, NC 28640 (336) 846-1039 (fax) (336) 246-3356 ALLEGHANY COUNTY P.O. BOX 309 SPARTA, NC 28675 (336) 372-7793(fax) (336) 372- 8813 WATAUGA COUNTY 126 POPLAR GROVE CONNECTOR BOONE, NC 28607 (828) 264-4997 (fax) (828) 264-4995 APPLICATION FOR WELL AND ON -SITE WASTEWATER PERMITS SECTION I INITIAL THE APPROPRIATE LINE(S) FOR WHAT THIS APPLICATION IS FOR: NEW WELL CONSTRUCTION PERMIT I WELL ABANDONMENT or CAMERA INSPECTION WELL CAMERA INSPECTION ✓ I REPAIR ( Well RELOCATION OF SEPTIC TANK NAME CHANGE SECTION 2 Owner of Property I aV;C( jPajp 0.) i.LSte e Phone: - Mailing Address: gaol S. evesiwiCk C. tWeicsht NC- 91'6/ Applicant: JGw «Q ?a.k It a.. l uS-te e Phone: Date Received: Health Department Use Only 1 ANEW SEPTIC SYSTEM (Improvement Permit) AUTIIORIZA'TION to CONSTRUCT (Septic permit required to get a building permit) l COMPLIANCE INSPECTION (for proposed construction location only) RENEWAL OF PERMIT ( Septic- non -expired only) (Well - -Expired / Non -expired ) I. ---[EXPANSION OF AN EXISITNG SEPTIC SYSTEM CHANGE OF EXISTING PERMIT ( Well / Septic) ( Limited / Comprehensive ) NMI (CI 19\ (Home) LI 9 I - 56 1/3 (Cell) Email: dpriC�yQ. 0O GOIY� (Home) (Cell) Mailing Address: fS0.�e BEmail: Agent: e,6(j Pt2 MO AS 1 I'll( A*L'(e W0.terwo ckS �▪ ** see page 3 Mailing Address: ? 0 . Box S'( I , C3(0 RocK , ti`( C, 9.8 60 5 Email: bo66y Oet41.o A 0 /1 INFORMATION ON THE PROPERTY TO BE EVALUATED 9Ma;(. [oM DETAILED Directions to Propcny: RA:01'125S IS I{ 1 1 t{ w.( 411 tit. VW(a s tikieS+ - l.eS oew•- I05 6'c€. Go esas V— cS* Chcistat+l C.kt; rand) iacus Y f k &u -4x. Ret9 61,t`c.k. kauSQ 6A. CtS k t. Phone: (828\(Home) L(0(p- 0000 (Cell) ▪ Property Size:. 6vS oCCQS Parcel ID/ PIN: 1.9Q - a S- OSa3 -OC) 0 County of Property: W0.tug0. ^ Subdivision Name: Lot #: Section: Date Platted** **Date property recorded with the county as it currently exists. YES I ✓NO Is any part of the property in the 100 flood plain? YES NO Are there any drinking water supplies within 100 feet of this property? (If yes show them on the site plan.) YES V.1 NO Is this property subject to watershed restrictions? SECTION 3 STRUCTURE INFORMATION DES 1BE THE EXISTING OR PROPOSED STRUCTURE: HOUSE I MOBILE HOME GARAGE APARTMENT BUSINESS / OTHER ] APARTMENTS /TOWNHOMES i CONSTRUCTION DESCRIBED BELOW Iv YES 1 INO Basement YES NO Water Fixtures in Basement Number of Bedrooms: 3 ^ Special Fixtures: Circle all that apply: Garbage Disposal, Oversized Tubs, Multi -head showers, Multiple Master Bathrooms or Kitchens Special Fixture Description: NA Business / Other Description: N Number of Employees: NA Square footage of Commercial Building: Hours of Operation: Compliance Inspection (for proposed construction only): Describe the proposed construction and show the location of any existing structures, proposed additions, excavation or other - improvements ton the property on the site plan. a Describe: IV - If you have an existing septic system, what year was it installed and under whose name was it permitted? SECTION 4 SECTION TO REOUEST AN ON -SITE WASTEWATER SYSTEM 'TYPE: Please Indicate Desired System Type(s) (Systems can be ranked in order ofyour preference): ' Any System Type 0 Accepted 0 Alternative 0 Conventional 0 Innovative ❑Other n SECTION 5 WATER SUPPLY INFORMATION (SHOW LOCATION ON SITE PLAN) NO Is water provided by a public water supply? Name of water supply system: (ryes then please skip to Section 8. ram Well will be used for: min Pal The following information applies to a: LIProposed Well Private Well Existing Spring (skip to section 8) x Shared Well Other Includes: Business, Restaurant, Daycare, Migrant housing, etc. Description: Existing Well Year the well was drilled: =Proposed Spring (skip to section 8) =Other (Describe below) CeSj eltee If different than the property described above, property the drinking water supply is located on. LOT #: Parcel ID #: Directions to the Water Supply: W tU. nett ( to base...m ir* door SHARED WELL INFORMATION What is number of the existing and/or possible future connections to this well? ( If more than one (1) connection, list the connections by Lot # and / or Parcel ID #: SECTION b WELL SITING INFORMATION N R ES NO Is there or are you proposing to place a fuel tank(s) on the property? (Not including propane or natural gas tanks) YES NO Is there a fuel tank(s) on the adjacent properties? YES NO Are there any easements, or right of ways recorded on this property? If yes describe and attach a copy of the easement and / or right of way documentation to this application: If you have an existing septic system, what year was it installed and under whose name was it permitted? SECTION 7 WELL ABANDONMENT or WELL CAMERA INSPECTION iv A Year the well was drilled: Depth of the existing well: Casing depth of the existing well: Describe why the well is being abandoned: Is there any contamination of the water in the well? ES L ✓ .EYES ES YES ES NO Property corners clearly and correctly identified NO Plat attached NO Proposed structures staked onsite NO Proposed well site staked 1 I NO Holes dug Permit Expiration Improvement (IP) 5years Construction Authorization (CA) (not to exceed the IP) 5 years Well Construction 5 years Compliance Inspections 1 year TO COMPLETE THE APPLICATION DRAW A DIAGRAM OF THE PROPOSED CONSTRUCTION ON THE SITE PLAN PAGE PROVIDED. Applicant must notify this department if this site is subject to approval by other public agencies (other than the planning and inspection department) or wastewater other than sewage will be generated. THIS APPLICATION AND FEES PAID WILL BE VALID FOR A PERIOD OF TWELVE MONTHS FROM DATE OF RECEIPT. AFTER 12 MONTHS THE APPLICATION IS VOID AND THE APPLICATION FEE IS NON-REFUNDABLE. ALL HEALTH DEPARTMENT PERMITS ARE SUBJECT TO SUSPENSION OR REVOCATION IF THE SITE PLAN OR THE INTENDED USE CHANGES. �! I CERTIFY THAT THE INFORMATION ON THIS APPLICATION IS TRUE AND CORRECT AND WILL NOT BE ALTERED WITHOUT PRIOR HEALTH DEPARTMENT APPR AL. �uxn cQ a, lela !caste it (a3I� a_SIGNATURE OF APPLICANT OR AUTHORIZED AGENT DATE 2 rmi MEI Mgt ASHE COUNTY P.O. BOX 208 JEFFERSON, NC 28640 (336) 846-1039 (fax) (336) 246-3356 APPALACHIAN DISTRICT HEALTH DEPARTMENT ALLEGHANY COUNTY WATAUGA COUNTY P.O. BOX 309 SPARTA, NC 28675 (336) 372-7793(fax) (336) 372- 8813 126 POPLAR GROVE CONNECTOR BOONE, NC 28607 (828) 264-4997 (fax) (828) 264-4995 PROPERTY TO BE EVALUATED MUST FILL OUT COMPLETELY Owner of Property: J0.1 t CC a(e Gh, 1 ('CU. tee Parcel ID / PIN #: 199 (` a s-- 0 8 a 3 - 000 Fa'' Subdivision Name: Pal Lot #: Section #: PROPERTY OWNER'S AUTHORIZATION FOR APPLICANT (Potential Buyer) 1, (name of property owner), being the owner or the legal pir' representative of the business which owns the property specifically described above, do hereby authorize (name of applicant) or their legal representative to pursue permits issued by the Appalachian District Health Department. 1 understand that this authorization ''o" includes but is not limited to: (1) Applying for Health Department permits, (2) Preparing the site for on -site soil evaluations, (3) Accomplishing other necessary actions as required by the Appalachian District Health Department (i.e backhoe pits, surveying, clearing the lot of underbrush), (4) Locating or gaining knowledge A'' of all pertinent fuel storage tanks, wells, springs, septic systems, etc... F, MR This authorization will be in effect until a written notice of revocation is received by this office from the owner, or until one year from date of signature by owner. (Owner's signature) (Date) m APPLICANT'S A UTHORIZA TION FOR AN AGENT TO ACT AS THEIR LEGAL REPRESENTA TI VE ,(-N j I, I ‘i ice1 rat et(. < \4 Q. (name), beingthe applicant for an Improvement Permit / ( ) PP P ,�, Author{{'z�ation for Wastewater System Construction and/or a Well permit do hereby authorize 'Boob QeewAoLkS (name)to act as an agent on my' g behalf to do the following: (1) Apply for Health D!partment permits, (2) Prepare the site for on -site soil evaluations,(3)Accomplish other necessary P m, actions as required by the Appalachian District Health Department (i.e. backhoe pits, surveying, clearing the lot of underbrush), (4) Locate or gain knowledge of all pertinent fuel storage, wells, springs, septic systems, etc... MI I understand that I or my legal representative must sign for all permits issued by the Health Department. This authorization will be in effect until a written notice of revocation is received by this office from the applicant. O. t1� cv tjakltA. TC-Ltstee. 143Ice. (Applicant's signature) (Date) (Authorized agent's signature) (Date) 3 MIN MIN MIR ASHE COUNTY P.O. BOX 208 JEFFERSON, NC 28640 (336) 846-1039 (fax) (336) 246-3356 APPALACHIAN DISTRICT HEALTH ALLEGHANY COUNTY P.O. BOX 309 SPARTA, NC 28675 (336) 372-7793(fax) (336) 372- 8813 DEPARTMENT WATAUGA COUNTY 126 POPLAR GROVE CONNECTOR BOONE, NC 28607 (828) 264-4997 (fax) (828) 264-4995 SITE PLAN I (MEASUREMENTS MUST BE ACCURATE. NAME: �Jo�vi� ?4Ie fa Tustee SEE EXAMPLE) DATE: !(-3-ta `118 RWy L(21 rt. \i (as, Nc Arc 1/ JO' Roo' 29 09' N 620/:52- .3/. 92' A/ 2/ 2/ 75 9.3 4,c_cs yd S 7777:510 /06.0/" shy ��c 4 • Stamps: -0- STATE OF NORTH CAROLINA COUNTY OF WATAUGA This Deed, made this FILED JaRnn Townsend Register of Deeds, Watauga Co,NC Recording Fee: $22.00 NC Real Estate TX: $.00 20101229000113170 NWD Bk:BR1550 Pg:803 12/29/2010 01:45:01 Pf1 112 It= II 11111111111111 NON -WARRANTY DEED day of December, 2010, by and between Andrew David Paletta (unmarried), 554 Dogwood Road, Boone, NC 28607 (hereinafter called "Grantor") and David R. Paletta, as Trustee for The David R. Paletta Living Trust dated December 5, 2000, 213 Landsbury Drive, Durham, NC 27707 (hereinafter called "Grantee") The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and shall include singular, plural, masculine, feminine, or neuter as required by context. WITNESSETH: The Grantor, for and in consideration of the sum of Ten Dollars and other good and valuable consideration paid by Grantee, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell, and convey unto the Grantee, all right, title and interest in that certain lot or tract of land situated in Watauga County, North Carolina, and more particularly described as follows: Prepared by: David R. Paletta, Attorney, 213 Landsbury Drive, Durham, NC 27707 Return to: GRANTEE PE anglign 8R1550 804 212 Being a .605 acre tract of land on the North side of Hwy 421 North, bounded by Wallace Cook on the West, North and East, and said road on the South, North being relative to NC Grid, and being more particularly described as follows: BEGINNING on a point in Hwy 421 North, the point located N 52-13 E 32.80' from NCGS Monument "Lovill" N-915675.41 E-1192028.24, thence from the BEGINNING and ,,,p, with said road N 70-30-19 W 151.01' to a point; thence leaving said road and with the center of 20' right of way N 14-43-05 E 18.20' to a point at the edge of pavement; thence continuing with the center of said right of way N 21-21-15 E 135.93' to a point; thence with a curve to the right having a radius of 29.09', an irn arc of 41.30 and a chord of N 62-01-45 E 37.92' to a point; thence S 77-17-40 E 106.01' to a point; thence leaving said road and with a new line S 14-26-10 W passing a 5/8" rebar at 10.00' and then another 5/8" rebar at 135.03' and then 50.02' for a total of 195.23' to the point and place of beginning, as shown on plat # 05002 dated January 7, 2005 by Hencle J. Matheson PLSL-2561. The property conveyed herein does not include the primary residence of the Grantor. TO HAVE AND TO HOLD the aforesaid lot or tract of land and all privileges and appurtenances thereunto belonging to the Grantee in fee simple. The Grantor makes no warranty, express or implied, as to title to the property herein above described. IN WITNESS WHEREOF, the Grantor has hereunto set her hand and seal, the day and year first above written. OJceIc(Seal) Andrew David Paletta (Seal) STATE OF NORTH CAROLINA COUNTY OF WATAUGA I, a Notary Public of said County and State, do hereby certify that Andrew David Paletta, Grantor, personally appeared before me this day and acknowledged the execution of the foregoing instrument. WITNESS my hand and official stamp or seal, this the day of December, 2010. 1.M4CLL3C (Notary Seal) otaryblic My commission expires: 1,),7ja01 *** Notary Seal must be placed within Margins *** **NOTE -SQUARE ACCESS FOR CONCRETE RISER OR OPTIONAL PLASTIC 20' ROUND RISER CAST -IN 107' 102' 55' 50' • ti VENT L 15•J �1-- 4' TOP VIEW r 17' *NOTEI ALL MEASUREMENTS ON TOP VIEW ARE TO WIDEST DIMENSIONS NO BOOTS ON- SIDE INLETS, USE CONCRETE KNOCKOUTS 65' INLET 54' TO BOTTOM OF 3' INLET 54' TO BOTTOM OF 4 INLET 105' 100' 31' 52' TO BOTTOM OF 4' OUTLET 52 1/2' TO BOTTOM OF 3' OUTLET 2i' 3' OR 4' OUTLET BOOTS ON OUTLET END ONLY OUTLET SHOAF PRECAST SEPTIC INC. MODEL: MS 1000 STB NON p p C NON TRAFFIC 1000 Gallon Septic Tank 4130 WEST US HWY 64 LEXINGTON, NC 27295 PHONE (336) 787-5826 FAX (336) 787-2826 W W W.SHOAFPRECAST.COM SHOAF-1000 NON TRAFFIC RATED STB-760 NON TRAFFIC LIQUID CAPACITY-1039 US GALLONS/9 i' AIRSPACE TANK HEIGHT-66' BOTTOM OF TANK TO CENTER OF INLET-56' BOTTOM OF TANK TO CENTER OF OUTLET-54' LENGTH TO WIDTH RATIO-2 TO 1 SIZE OF INLET & OUTLET-3' OR 4' PIPE TYPE OF INLET & OUTLET-POLYLOCK OR EQUAL <MEETS ASTM C-923) CONCRETE PSI-4000J TANK WEIGHT-8,500 LBS. REINFORCING PER STATE CODE *NOTE - TEE NOT SUPPLIED SCALE - N.T.S. STATE APPROVAL # SHOAF-1000 STB-760 1' BUTYL RUBBER MASTIC SEALANT CONTINUOUS IN JOINT [ [ f 1 [ [ [ [ [ f 1 1 f 1 1 1 1 1 1 0 0 0 '. M 2 0 O O .-1 1.0 M TOPO! map printed on 05/23/13 from "Untitled.tpo" 81°45.000' W 81°44.000' W �► e. Lwifti ii1JBv Laphic; 020d5 ele-Att0 Rel. 8/200 81°46.000' W 81°45.000' W 81°44.000' W 0 S 1 WGS84 81°43.000' W 36°15.000' N 36°14.000' N WGS84 81°43.000' W MN* TN NATIONAL GEOGRAPHIC MILES 100000 -. 0 1000 2000 2000 4000 5120 FEET .5 0 1000 KIOMETEE1S 0 Mf!FOS 05/23/13