Loading...
HomeMy WebLinkAboutWS0500158_Application_20220303NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY — DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A WATER SUPPLY WELL OR WELL SYSTEM (Wells or Well Systems with a Design Capacity of 100,000 Gallons Per Day or Greater) PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct water supply wells. 1. Date: January 19, 2022 2. County: Wake 3. Applicant Ten Oaks Realty LLC PERMIT NO. FOR OFFICE USE ONLY ISSUED DATE: Telephone: 410-459-8401 Applicant's Mailing Address: P.O. Box 257, Fallston, Maryland 21047 Applicant's Email Address (if available): Fred a@tenoaksrealty.com 4. Contact Person (if different than Applicant): Paul S. Scott, Geo-Technology Associates, Inc. Telephone: 410-515-9446 Contact Person's Mailing Address: 3445 Box Hill Corp. Center Drive, Suite A, Abingdon, MD 21009 Contact Person's Email Address (if available): PScott@gtaeng.com 5. Property Owner (if different than Applicant): Patricia Lasater Duma & Debra L Flentje Telephone: 410-227-3031 Owner's Mailing Address: 7835 Valleyfield Drive, Springfield, VA 22153 Owner's Email Address (if available): 6. Property Physical Address (including PIN Number): 8736 Bells Lake Road Pin: 0679603162 City: Middle Creek County: Wake 7. Intended use of Well or Well System: Potable supply (examples: irrigation, consumption, etc.) Zip Code: 27539 8. Will the proposed water supply well or well system replace or be added to an existing well or well system? Yes (If yes, complete questions 7 and 8) (If no, complete question 7 and then skip to question 9) 9. Total design capacity of proposed well or well system in gallons per day (gpd): Estimated 80 gpm 10. If adding a well to an existing system, list the existing water supply wells in the existing system and their respective yields: Sawyers Mill Well #10 — 17 qpm (PWSS # 02-00225) , Well #4 — 65 qpm (PWSS # 00-00814), Well #8 — 31 gpm (PWSS # 01-01304) 11. Is this a public well or well system? Yes If yes, give Public Water ID Number: 43-92-216 If yes, give Project Engineer and contact information: Lindsay Mize, Aqua North Carolina, Inc. 919-653-6967 12. Well Contractor: Triad Drillers, Inc. Well Contractor Certification No.: 2461 Well Contractor Address: 8828 Kerrs Chapel Road, Elon, NC 27244 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter b. Estimated well depth c. Screen intervals d. Sand/gravel pack intervals e. Type of casing material and thickness f. Grout horizons g. Well Head completion details 2. No. of wells to be constructed in unconsolidated material: 0 3. No. of wells to be constructed in bedrock: 5 4. Total No. of wells to be constructed: 5 (add answers from 2 and 3) 5. Estimated beginning construction date: 3/21/2022 6. Estimated construction completion date: 4/1/2022 Continued on Reverse DocuSign Envelope ID: F9A30775-C100-4F10-B37F-F512789591 D1 ADDITIONAL INFORMATION Signre of Applicant or *Agent e ( Printed name of Applicant or *Agent 1 As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.106(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. 2. As required by 15A NCAC 02C .0105(g)(3), for wells screened in multiple zones or aquifers, provide representative data on the static water level, pH, specific conductance, and concentrations of sodium, potassium, calcium, magnesium, sulfate, chloride, and carbonates from each aquifer or zone from which water is proposed to be withdrawn. 3. Attach any water use permits (if required). [e.g. Central Coastal Plain Capacity Use Area Permit is required in 15 eastern NC counties by NC Division of Water Resources, visit: http://www.ncwater.org] SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of the Water Supply Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules Jjt144, c z /'C401 /Pi g4 s- (M„ Title of Applicant or *Ager * If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct water supply wells as outlined in this Water Supply Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the water supply well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). DocuSigned by: Feb 22, 2022 1 7:21 AM Para L. Flentje Agperty Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mali Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9897 Wrlif$441* 11 IEIF 1 noon GW-22W Rev. 3-1-2016 ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality March 2, 2022 Dear Ms. Patricia Duma and Ms. Debra Lasater Flentje 7835 Valleyfield Dr. Springfield, VA 22153-4117 Re: Preliminary Well Site Approval Sawyer's Mill S/D Water System No.: NC4392216 Wake County Dear Ms. Patricia Duma and Debra L. Flentje Lasater: On January 26, 2022 Tripp Pearce and I met with Paul S. Scott, Wayne Barefoot and Joshua Robertson and conducted a preliminary investigation of the proposed well sites listed below. The proposed wells have been assigned Water System Facility (WSF) Identification Numbers and Sampling Point Codes as indicated below. WSF ID No. Sampling Point Code Description of Well Site Preliminary Latitude and Longitude SW11 RW11 100' radius around the proposed well location is West of RW12 and is located East of Sawyer's Mill Drive, at preliminary coordinates. 35°38'44.3"N 78°44'32.0"W SW12 RW12 100' radius around the proposed well location is West of RW13 and is located West of Northern Falls Road, at preliminary coordinates. 35°38'44.7"N 78°44'34.1"W SW13 RW13 100' radius around the proposed well location located in the southeast corner of the property adjacent to Bells Lake Road, at preliminary coordinates. 35°38'44.6"N 78°44'32.0"W SW14 RW14 100' radius around the proposed well location is southwest of RW15 and is located West of Northern Falls Road, at preliminary coordinates. 35°38'50.8"N 78°44'35.1"W SW15 RW15 100' radius around the proposed well location located in the northeast corner of the property adjacent to Bells Lake Road, at preliminary coordinates. 35°38'55.1"N 78°44'29.8"W NOR DE _ oepa,tme�ll41 Ernl,pnmenial9ualih North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 3800 Barrett Drive I Raleigh, North Carolina 27609 919,791.4200 Dear Ms. Patricia Duma and Ms. Debra Lasater Flentje March 2, 2022 Page 2 This letter is provided by the Public Water Supply (PWS) Section, in accordance with Rule .0305(b) of the Rules Governing Public Water Systems (15A NCAC 18C), to provide permission to drill wells at the listed sites in order to establish the quality and quantity of water and the suitability of the wells as sources for a public water system. In addition, this "preliminary well site approval" is to acknowledge that according to the information and documentation provided, we understand that the proposed wells are located on lots so that the area within 100 feet of the wells is owned or controlled by the person supplying the water and that the supplier of water will protect the well lots from potential sources of pollution and construct landscape features for drainage and diversion of pollution as required in 15A NCAC 18C .0203(a)(1). We understand that while one or more of the proposed well sites do not currently satisfy the minimum horizontal separation distances summarized in the table below, they must meet those requirements as specified in 15A NCAC 18C .0203(a)(2) for the wells to be utilized as a source for a public water system. Following the determination of well suitability, compliance with 15A NCAC 18C .0203(a)(2) would require, but is not limited to, the removal of any existing surface water such as the existing onsite ponds or other potential sources of pollution (e.g., existing wells, subsurface sanitary disposal systems, etc.) and appropriate remediation of the site. Existing wells within 100 feet of a proposed well must be abandoned in accordance with 15A NCAC 02C. Distance (in feet) Potential Source of Pollution 100 • • • • • From any sanitary sewage disposal system, sewer, or sewer pipe (unless sewer is constructed of water main materials and joints, in which the sewer pipe shall be at least 50 feet from the well. From buildings, mobile homes, permanent structures, animal houses or lots, cultivated areas to which chemicals are applied. From surface water. From a chemical or petroleum fuel underground storage tank with secondary containment. From any other potential source of pollution not listed in this table. 200 • From a subsurface sanitary sewage treatment and disposal system designed for 3,000 or more gallons of wastewater a day, unless your well water source is a confined aquifer. 300 • From any cemetery or burial ground. 500 • • • • From a septage disposal site. From a chemical or petroleum fuel underground storage tank without secondary containment. From the boundary of a ground water contamination area. From a sanitary landfill or non -permitted non -hazardous solid waste disposal site. 1,000 • From a hazardous waste disposal site or in any location which conflicts with the North Carolina Hazardous Waste Management Rules cited in NCAC 13A. GCSE . ilrAHounn OBpaNnenl el Environmental Quality North Carolina Department of Environmental Quality 1 Division of Water Resources Raleigh Regional Office 3800 Barrett Drive 1 Raleigh, North Carolina 27609 919.79t.4200 Dear Ms. Patricia Duma and Ms. Debra Lasater Flentje March 2, 2022 Page 3 We also understand that the owner will ensure that the lots are graded or sloped so that surface water is diverted away from the wellheads and that the wells shall not have greater than a 1 percent chance of flooding in accordance with 15A NCAC 18C .0203(a)(4). PWS Section "Authorization to Construct" and "Final Approval" Subsequent to well drilling and evaluating water quality and quantity (e.g., collecting and analyzing samples and performing a 24-hour well drawdown test) the owner must submit an "Application for Approval of Engineering Plans and Specifications For Water Supply Systems" to document proposed well completion (e.g., selected pump, wellhead and well house details) and associated transmission lines, treatment and/or storage facilities and other critical information about the public water system. In accordance with 15A NCAC 18C .0305(a) no construction shall be undertaken until the PWS Section issues an "Authorization to Construct" letter. In addition, in accordance with 15A NCAC 18C .0309(a) the new wells and all associated treatment, storage or transmission/distributions lines shall not be placed into service until the PWS Section has issued a "Final Approval." These steps are described in the Engineering Planning and Development Guidance Document available at https://files.nc.gov/ncdeq/Water%20Resources/files/pws/planreview/EPD Guidance Jul y2019.pdf Be aware that plans, specifications and reports for the new wells must be certified by a Professional Engineer. Therefore, it is recommended that a Professional Engineer or Licensed Geologist (or their designated representative) experienced in the construction of water supply wells, conduct on -site monitoring of well construction. At a minimum, certain critical phases of well construction such as installation and grouting of casing should be monitored. In many situations it may be necessary to go beyond the minimum requirements in order to protect the public health and ground water resources. Other Agency Approvals Required This PWS Section "preliminary well site approval" letter does not address other agency applicable rules and requirements pertaining to well construction and registration. Local county well construction rules and ordinances may include additional requirements. Well construction must meet the standards specified in the Well Construction Standards (15A NCAC 2C). Be aware that these rules require a permit to be obtained from the Water Quality Regional Operations Section of the Division of Water Resources before the well is constructed if it is anticipated that the new well will be part of a water system with a design capacity of 100,000 gallons per day or greater. In addition, these rules require that wells be constructed by a properly certified well driller. For more information, call 919-707- 3668 or go to: GCSE . ilrAHounn OopaNnenl el Environmental Quality North Carolina Department of Environmental Quality 1 Division of Water Resources Raleigh Regional Office 3800 Barrett Drive 1 Raleigh, North Carolina 27609 919.79t.4200 Dear Ms. Patricia Duma and Ms. Debra Lasater Flentje March 2, 2022 Page 4 https://deq.nc.gov/about/divisions/water-resources/water-resources- permits /wastewater -branch ground-water-protection/well-program#largecapwell Sincerely, Catherine Hadidon Assistant Regional Engineer Public Water Supply Section Raleigh Regional Office Cc: Central Files - Public Water Supply Section Regional Files - Public Water Supply Section Paul S. Scott, P.G (email) AQUA North Carolina (email) Wake County Health Department Fred Sheckells, Ten Oaks Communities, LLC oapammem ��`��` e[ En.[mnmemn[ quao� NORTN North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive j Raleigh, North Carolina 27609 919.791.4200 \\PSMC-DATA\gta\Shared\Project Files\2021\35211800x1 - Bells Lake Road\GWW\CAD\Plot\35211800x1 Potential WLP.dwg SOURCE: PLAN ADAPTED FROM AERIAL PHOTOGRAPHY OF WAKE COUNTY, NORTH CAROLINA, PRODUCED AND MAINTAINED BY GOGGLE LEGEND APPROXIMATE SUBJECT PROPERTY APPROXIMATE PROPOSED TEST WELL LOCATION APPROXIMATE LOCATION OF STRUCTURE ASSUMED TO BE SERVICED BY ONSITE WASTEWATER DISPOSAL (SEE NOTE) APPROXIMATE EXISTING RESIDENTIAL WELL LOCATION (SEE NOTE) NOTE: LOCATIONS OF OFF -SITE RESIDENTIAL WELLS AND STRUCTURES SERVICED BY SEPTIC SYSTEMS ARE APPROXIMATE, AND ARE BASED ON LOCATIONS PROVIDED ON THE WAKE COUNTY AND RALEIGH GIS iMAPS ONLINE INTERACTIVE MAPPING APPLICATION 0' 25' 50' 100' 200' SCALE: 1" 100' .--".••,--sm' GEO-TECHNOLOGY ASSOCIATES, INC. GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS 3445-A BOX HILL CORPORATE CENTER DRIVE ABINGDON, MARYLAND 21009 410-515-9446 FAX: 410-515-4895 WWW.GTAENG.COM 0 2019 GEO-TECHNOLOGY ASSOCIATES, INC. PROPOSED TEST WELL LOCATION PLAN - AERIAL BELLS LAKE ROAD WAKE COUNTY, NORTH CAROLINA DATE REVISIONS JOB NO: 35211800 SCALE: 1"=100' DATE: MARCH 2022 DRAWN BY: GMM DESIGN BY: REVIEW BY: PSS SHEET: OF \\PSMC-DATA\gta\Shared\Project Files\2021\35211800x1 - Bells Lake Road\GWW\CAD\Plot\35211800x1 Potential WLP.dwg SOURCE: PLAN ADAPTED FROM ENTITLED "WELL LAYOUT" PREPARED BY MORRIS & RITCHIE ASSOCIATES AND DATED FEBRUARY 22, 2022 LEGEND APPROXIMATE SUBJECT PROPERTY APPROXIMATE PROPOSED TEST WELL LOCATION APPROXIMATE LOCATION OF STRUCTURE ASSUMED TO BE SERVICED BY ONSITE WASTEWATER DISPOSAL (SEE NOTE) APPROXIMATE EXISTING RESIDENTIAL WELL LOCATION (SEE NOTE) NOTE: LOCATIONS OF OFF -SITE RESIDENTIAL WELLS AND STRUCTURES SERVICED BY SEPTIC SYSTEMS ARE APPROXIMATE, AND ARE BASED ON LOCATIONS PROVIDED ON THE WAKE COUNTY AND RALEIGH GIS iMAPS ONLINE INTERACTIVE MAPPING APPLICATION 0' 20' 40' 80' 160' SCALE: 1"=80' GEO-TECHNOLOGY ASSOCIATES, INC. GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS 3445-A BOX HILL CORPORATE CENTER DRIVE ABINGDON, MARYLAND 21009 410-515-9446 FAX: 410-515-4895 WWW.GTAENG.COM 0 2019 GEO-TECHNOLOGY ASSOCIATES, INC. PROPOSED TEST WELL LOCATION PLAN BELLS LAKE ROAD WAKE COUNTY, NORTH CAROLINA DATE REVISIONS JOB NO: 35211800 SCALE: 1 "=80' DATE: MARCH 2022 DRAWN BY: GMM DESIGN BY: REVIEW BY: PSS SHEET: OF