HomeMy WebLinkAboutSW3220302_Supplement-EZ Form_20220308SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1
Project Name
Denver Defense
2
Project Area ac
4.494
3
Coastal Wetland Area ac
N/A
4
Surface Water Area ac
N/A
5
Is this promect High or Low Density?
High
6
Does this project use an off -site SCM?
No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided feet
0
8
Will the vegetated setback remain vegetated?
N/A
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ?
N/A
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
1
17
1 Rainwater Harvesting RWH
18
1 Green Roof
19
Level Spreader -Filter Strip LS-FS
20
1 Disconnected Impervious Surface DIS
21
ITreatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
25
Bayfliter
26
Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Jay Henson, Principal
28
Organization:
HensonFole
29
Street address:
121 Gilead Rd.
30
City, State, Zip:
Huntersvill, NC, 28078
31
Phone numbers :
704-875-1615
32
Email:
jay@hensonfoley.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that
the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
C AR0C/4//i
O'C,•_
~�N 7009�'
*:
tr 3 t. 7A-
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
1
3
Does this project have low density areas?
No
4
If so number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
AREA INFORMATION
Entire Site
1
4
Type of SCM
sand filter
sand filter
5
Total draina a area s ft
119602
119602
6
Onsite draina e area s ft
117333
117333
7
Offsite draina a areas ft
2269
2269
8
Total BUA in project (sq ft)
103998 sf
103998 sf
9permitting)
New BUA on subdivided lots (subject to
s ft
N/A
N/A
10permitting)
New BUA not on subdivided lots (subject to
sf
70025 sf
70025 sf
11
JOffsite BUA (sq ft
N/A
N/A
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft
50847 sf
50847 sf
Sidewalk (sq ft
1974 sf
1974 sf
Roof (sq ft
17203 sf
17203 sf
Roadway s ft
Future (sq ft
Other, please specify in the comment box
below (sq ft
13
New infiltrating permeable pavement on
subdivided lots (sq ft
N/A
N/A
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
N/A
N/A
15permitting)
Existing BUA that will remain (not subject to
s ft
33973 sf
33973 sf
16
lExisting BUA that is already permitted (sq ft
50545 sf
50545 sf
17
Existing BUA that will be removed (sq ft
16572 sf
16572 sf
18
Percent BUA
53%
53%
19
Design storm inches
1.0 in
1.0 in
20
Design volume of SCM cu ft
4611 cf
4611 cf
21
Calculation method for design volume
ISimple RV method
Simple RV method
ADDITIONAL INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
With site conditions it was found impossible to get all new BUA to BMP. As
a comprimise, some existing BUA would be taken to bmp and that the final
BUA number to BMP was greater than proposed BUA.
SAND FILTER
ERAL MDC IMM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
NG
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other
engineered side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
10- ear storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
desi n volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Drawdown Orifice
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
151
Is there an O&M Plan that complies with General MDC (12)?
Yes
161
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensedprofessional?
Yes
SAND FILTER
MDC FROM 02H .1056
18
SHWT elevation (fmsl)
PROVIDED AT
LATER DATE
19
Type of sand filter (open or closed)
Open
20
If closed, will the filter will be pre -cast or pour -in -place?
21
If closed, top of grate elevation (fmsl)
22
Is this sand filter designed to attenuate peak flows?
Yes
Sediment Chamber
23
Volume that can be retained in the sediment chamber (cubic feet)
1000 cf
24
Will there be a permanent pool in the sediment chamber?
No
25
Bottom of the sediment chamber (fmsl)
842.00
26
Area of the sediment chamber (square feet)
500 sf
27
Physical depth of the sediment chamber (inches)
24 in
28
Ponding depth in the sediment chamber, above any permanent
pool (inches)
24 in
29
Elevation of top of weir between chambers (fmsl)
844
I Sand Chamber
30 Volume that can be retained in the sand chamber (cubic feet)
311 Bottom of the sand chamber (fmsl)
32 Area of the sand chamber (square feet)
33 Physical depth of the sand chamber (inches)
34 Ponding depth in the sand chamber, above the sand surface
(inches)
12384 cf
841.50
510 sf
18 in
48 in
35
Elevation of the bypass device (fmsl)
845.5
36
Type of bypass device
SPILLWAY
37
Mechanism for distributing flow over the sand surface
RIP -RAP BERM
38
Sand specification for sand chamber
ASTM C33
39
Depth above underdrain pipe (inches)
24 in
40
Will the media be maintained to drain at least two inches per hour at
the sand surface?
Yes
41
Is at least one clean -out pipe provided at the low point of each
underdrain line?
Yes
42
Will clean -out pipes be capped?
Yes
ADDITIONAL
INFORMATION
43
Please use this space to provide any additional information about
the sand filter(s):
Sand Filter 3 10:43 AM 2/24/2022