Loading...
HomeMy WebLinkAboutWS0801067_Application_20220303GMA The Groundwater Experts March 3, 2022 Mr. Geoff Kegley Hydrogeologist North Carolina Division of Water Resources 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Groundwater Management Associates, Inc. 4300 Sapphire Court, Suite 100 Greenville, North Carolina 27834 Telephone: (252) 758-3310 www.omo-nc.com Apex and Greenville, NC Re: Water Supply Well Construction Permit Application, Bogue Banks Water Corporation, Emerald Isle, Carteret County, North Carolina Dear Mr. Kegley, Please find enclosed an application for a permit to construct one water -supply well (PW1D) for the Bogue Banks Water Corporation (BBWC), Carteret County, North Carolina. Groundwater Management Associates, Inc. (GMA) is working with BBWC to provide professional consulting services associated with the drilling, construction, and testing of one water supply well at 701 Emerald Drive, Emerald Isle, Carteret County, North Carolina. New water supply well PW1D is intended to be constructed as a replacement on the same property as the former/abandoned well PW1. New water supply well PW1D will be constructed in the Middle Castle Hayne Aquifer. The enclosed permit application includes the GW-22W form, BBWC 2020 Local Water Supply Plan, a diagram of the proposed well construction, a map detailing location and parcel information, and a copy of the Well Site Variance Approval letter issued by Heidi Cox with the NCDEQ Public Water Supply Section. The water supply well will be constructed of PVC and stainless -steel casing, and stainless -steel screens, and built according to the North Carolina Well Construction Standards (NCAC 02C). Casings will be properly grouted to prevent interconnection of the aquifers. Certified Well Contractor Magette Well and Pump Company (Magette) of Ahoskie, North Carolina will be contracted to perform the drilling operations, and Magette is ready to begin as soon as we have a well permit. Our plan is to have Magette begin drilling operations by April 1st, 2022, pending receipt of the well construction permit. Your help with meeting our proposed timetable would be appreciated. Mr. Kegley Page 2 We trust that the information provided herein is complete and will meet your requirements for issuing a well construction permit for replacement well PW1D. If you have any questions, please contact me at the address and phone number on our letterhead. Best regards, Groundwater Management Associates, Inc. Kelley A. Smith, P.G. Project Hydrogeologist Enclosures: Monitoring Well Permit Application Forms BBWC Local Water Supply Plan (2020) Proposed Well Construction Diagram Location and Parcel Map Carteret County Parcel Data Well Site Variance Approval Letter CC: Seola Hill-BBWC NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A WATER SUPPLY WELL OR WELL SYSTEM (Wells or Well Systems with a Design Capacity of 100,000 Gallons Per Day or Greater) PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct water supply wells. 1. Date: March 3, 2022 2. County: Carteret County FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE: 3. Applicant: Seola Hill - Bogue Banks Water Corp. (BBWC) Telephone: (252) 354-3307 Applicant's Mailing Address: 7412 Emerald Dr, Emerald Isle, NC 28594 Applicant's Email Address (if available): shill boguebankswater.com 4. Contact Person (if different than Applicant): Kelley A. Smith, PG (GMA) Telephone: (252) 758-3310 Contact Person's Mailing Address: 4300 Sapphire Ct., Suite 100, Greenville, NC 27858 Contac Person's Email Address (if available): kelley()gma-nc.com 5. Property Owner (if different than Applicant): BBWC (Applicant) Telephone: (252) 354-3307 Owner's Mailing Address: 7412 Emerald Dr, Emerald Isle, NC 28594 Owner's Email Address (if available): shill6d�boguebankswater.com 6. Property Physical Address (including PIN Number): 701 Emerald Drive (PIN: 632410456539000) City: Emerald Isle, NC 28594 County: Carteret Zip Code: 28594 7. Intended use of Well or Well System: Public Water Supply Well (Replacement to the former/abandoned PW1) (examples: irrigation, consumption, etc.) 8. Will the proposed water supply well or well system replace or be added to an existing well or well system? Yes, replace PW1 (If yes, complete questions 7 and 8) (If no, complete question 7 and then skip to question 9) 9. Total design capacity of proposed well or well system in gallons per day (gpd): 576,000 GPD 10. If adding a well to an existing system, list the existing water supply wells in the existing system and their respective yields: See attached BBWC Local Water Supply Plan (2020) W 12 Is this a public well or well system? Yes If yes, give Public Water ID Number: 04-16-028 If yes, give Project Engineer and contact information: John Wise, PE, Groundwater Management Associates (919) 363-6310 Well Contractor: Magette Well & Pump Co. Certification No.: 2299 Well Contractor Address: 2342 US 13 S, Ahoskie, NC 27910 PROPOSED WELL CONSTRUCTION INFORMATION As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter b. Estimated well depth C. Screen intervals d. Sand/gravel pack intervals e. Type of casing material and thickness f. Grout horizons g. Well Head completion details 2. No. of wells to be constructed in unconsolidated material: 3. No. of wells to be constructed in bedrock: 4. Total No. of wells to be constructed: (add answers from 2 and 3) 5. Estimated beginning construction date: 6. Estimated construction completion date: Continued on Reverse ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well orwell system. b. All existing wells, identified by type of use, within 500 feet of the proposed well orwell system. C. The proposed well orwell system. d. Any test borings within 500 feetof proposed well orwell system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical orfuel storage areas, animal feedlots as defined in G.S. 143-215.1013(5), landfills, orotherwaste disposal areas)within 500 feet of the proposed well or well system. As required by 15A NCAC 02C .0105(g)(3), for wells screened in multiple zones or aquifers, provide representative data on the static water level, pH, specific conductance, and concentrations of sodium, potassium, calcium, magnesium, sulfate, chloride, and carbonates from each aquifer or zone from which water is proposed to be withdrawn. Attach any water use permits (if required). [e.g. Central Coastal Plain Capacity Use Area Permit is required in 15 eastern NC counties by NC Division of Water Resources, visit: http://www.ncwater.org] SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and coed itions of the Water Supply Well Construction Permitas regulated underthe Well Construction Standards (Title 15A of the North Carolina Administrative Cpde, Subchapter2C) and accepts full responsibilityforcom pliance with these rules Executive Director — Bogue Banks Water Corp. Signature of Applicantor *Agent Title of Applicant or *Agent Seola Hill `If signing asAgent, attach authorization agreementstating Printed name of Applicantor "Agent that you have the authority to act as the Agent. If the property is owned by someone otherthan the applicant, the property owner hereby consents to allow the applicantto construct water supplywellsas outlined in this Water Supply Well Construction Perm itapplication and thatit shall be the responsibil ityof the applicantto ensure that the water supplywell(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter2C). Signature of Property Owner (if differentthan Applicant) Printed name of Property Owner (if differentthan Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office Raleigh Regional Office Wilmington Regional Office 2090 U.S. Highway 70 3800 Barrett Drive 127 Cardinal Drive Extension Swannanoa, NC 28778 Raleigh, NC 27609 Wilmington, NC 28405 Phone: (828) 296-4500 Phone: (919) 791-4200 Phone: (910) 796-7215 Fax: (828) 299-7043 Fax: (919) 571-4718 Fax: (910) 350-2004 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910)433-3300 Fax: (910)486-0707 Mooresville Regional, Office 610 East CenterAvenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 GW-22W Rev.3-1-2016 3/3/22, 12:53 PM DWR:: Local Water Supply Planning Bogue Banks Water Corp 2020 The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR. 1. System Information Contact Information Water System Name: Bogue Banks Water Corp Mailing Address: P.O. Box 4009 Emerald Isle, NC 28594 Contact Person: Phone: Secondary Contact Mailing Address: Distribution System Polyvinyl Chloride Polyvinyl Chloride Polyvinyl Chloride Polyvinyl Chloride Polyvinyl Chloride Seola Hill 252-354-3307 Telia Galloway PO Box 4009 Emerald Isle, NC 28594 Line Type ariy691 5 Bfffyk-] Ownership: Non -Profit Title: Executive Director Cell/Mobile: 252-515-6353 Phone: 252-354-3307 Cell/Mobile: 252-515-6353 Size Range (Inches) 2 3 6 8 12 Complete Estimated % of lines 10.00 % 5.00 % 62.00 % 20.00 % 3.00 % What are the estimated total miles of distribution system lines? 84 Miles How many feet of distribution lines were replaced during 2020? 0 Feet How many feet of new water mains were added during 2020? 370 Feet How many meters were replaced in 2020? 1,009 How old are the oldest meters in this system? 15 Year(s) How many meters for outdoor water use, such as irrigation, are not billed for sewer services? 64 What is this system's finished water storage capacity? 1.5000 Million Gallons Has water pressure been inadequate in any part of the system since last update? Line breaks that were repaired quickly should not be included. No No public sewer is available. Only privately owned and run neighborhood systems. Programs Does this system have a program to work or flush hydrants? Yes, As Needed Does this system have a valve exercise program? Yes, Annually Does this system have a cross -connection program? Yes Does this system have a program to replace meters? Yes Does this system have a plumbing retrofit program? No Does this system have an active water conservation public education program? Yes Does this system have a leak detection program? No https://www.ncwater.org/WUDC/app/LWSP/report.php?pwsid=04-16-028&year=2020 1/5 3/3/22, 12:53 PM DWR :: Local Water Supply Planning Water Conservation What type of rate structure is used? Increasing Block How much reclaimed water does this system use? 0.0000 MGD For how many connections? 0 Does this system have an interconnection with another system capable of providing water in an emergency? Yes 2. Water Use Information aervice Area Sub-Basin(s) % of Service Population County(s) White Oak River (17-1) 100 % Carteret What was the year-round population served in 2020? 4,995 What was the seasonal population and months served in 2020? (if applicable) 30,000 ( Jun Jul Aug Sep ) Has this system acquired another system since last report? No Water Use by Type Type of Use Metered Metered Non -Metered Connections Average Use (MGD) Connections Residential 6,533 1.2330 0 Commercial 130 0.2890 0 Industrial 0 0.0000 0 Institutional 0 0.0000 0 How much water was used for system processes (backwash, line cleaning, flushing, etc.)? 0.3370 MGD Water Sales Average Purchaser PWSID Daily Sold (MGD) Town of Pine Knoll 04-16- 0.0000 Shores 031 3. Water Supply Sources Monthly Withdrawals & Purchases Average Daily Max Day Use (MGD) Use (MGD) % of Service Population 100 % Non -Metered Estimated Use (MGD) 0.0000 0.0000 0.0000 0.0000 Contract Required to Pipe Days comply with Size(s) Used water MGD Expiration Recurring use restrictions? (Inches) 0 0.5000 Yes Yes 6 Average Daily Use (MGD) Jan 1.0768 1.8250 May 2.2803 Feb 1.0101 1.2860 Jun 2.2931 Mar 1.1491 1.4930 Jul 3.2290 Apr 1.4565 1.8090 Aug 2.8725 lir Ground Water Sources Average Daily Withdrawal Name or (MGD) Max Day Withdrawal Number (MGD) MGD Days Used 1 0.0241 114 0.0650 10 0.2119 238 0.7730 11 0.1652 128 0.7700 12 0.6470 206 1.1380 2 0.0779 141 0.3540 3A 0.2637 146 0.9270 4A 0.4570 239 0.7680 https://www. ncwater.org/W U DC/app/LWSP/report. php?pwsid=04-16-028&year=2020 Use Type Emergency Max Day Average Daily Max Day Use (MGD) Use (MGD) Use (MGD) 3.2460 Sep 2.4573 3.8160 3.3545 Oct 2.0074 2.4380 4.7750 Nov 1.4142 2.2280 3.8390 Dec 1.1551 1.5270 12-Hour CUA Year Supply Reduction Offline Use Type (MGD) 0.2160 CUAO Regular 0.9360 CUAO 0.9360 CUAO 1.7280 CUAO 0.4464 CUAO 1.2816 CUAO 0.9994 CUAO 2/5 3/3/22, 12:53 PM DWR :: Local Water Supply Planning 5A 0.6028 237 1.0430 1.5826 CUAO 6 0.0721 127 0.3270 0.4464 CUAO 7A 0.2054 253 0.7620 1.2240 CUAO 8 0.4528 229 0.6380 0.5760 CUAO 9 0.0915 118 0.3880 0.4464 CUAO Ground Water Sources (continued) Casing Depth Screen Depth (Feet)(Feet) Name or Number Well Depth (Feet) Well Diameter (Inches) Pump Intake Depth (Feet) Metered? Top Bottom 1 283 240 283 4 110 Yes 10 293 214 288 12 100 11 218 98 208 12 91 12 246 166 209 10 156 2 228 175 205 10 140 3A 245 180 240 10 160 4A 220 167 219 10 158 5A 205 155 200 10 130 6 226 192 222 10 140 7A 287 242 282 10 160 8 192 160 192 17 130 9 200 182 200 10 110 Are ground water levels monitored? Yes, Monthly Does this system have a wellhead protection program? Yes Water Purchases From Other Systems Average Contract Required to comply with Pipe Daily Seller PWSID Days water Use Size(s) Purchased Used use (Inches) Type (MGD) MGD MGD Expiration Recurring restrictions? Town of Pine Knoll 04-16- 0.0000 0 0.5000 Yes Yes 6 Emergency Shores 031 Water Treatment Plants Plant Name PermittedCapacity (MGDRO Is Raw Water Metered? Is Finished Water Ouput Metered? Source Plant 1.5000 Yes Yes Castle Hayne Aquifer Well 1 0.2160 Yes Yes Castle Hayne Aquifer Well 10 0.9360 Yes Yes Castle Hayne Aquifer Well 2&9 Common Header 0.8920 Yes Yes Castle Hayne Aquifer Well 3A 1.2810 Yes Yes Castle Hayne Aquifer Well 6&11 1.3820 Yes Yes Castle Hayne Aquifer Well 7A 1.2240 Yes Yes Castle Hayne Aquifer Did average daily water production exceed 80% of approved plant capacity for five consecutive days during 2020? No If yes, was any water conservation implemented? Did average daily water production exceed 90% of approved plant capacity for five consecutive days during 2020? No If yes, was any water conservation implemented? Are peak day demands expected to exceed the water treatment plant capacity in the next 10 years? No 4. Wastewater Information Monthly Discharges Average Daily Average Daily Average Daily Discharge (MGD) Discharge (MGD) Discharge (MGD) https://www. ncwater.org/W U DC/app/LWSP/report. php?pwsid=04-16-028&year=2020 3/5 3/3/22, 12:53 PM DWR :: Local Water Supply Planning Jan 0.2320 May 0.4140 Sep 0.4660 Feb 0.2300 Jun 0.4530 Oct 0.4280 Mar 0.2300 Jul 0.4340 Nov 0.2370 Apr 0.2320 Aug 0.4560 Dec 0.2300 Bogue Banks Water Corp's 2020 Monthly Discharges i o 1 w Avg Daily LD aU CL c 0 LD 4 p I y'* How many sewer connections does this system have? 0 How many water service connections with septic systems does this system have? 6,200 Are there plans to build or expand wastewater treatment facilities in the next 10 years? Yes We are planning to build a 2nd Reverse Osmosis Treatment Plant in the next 5 years as soon as we can get additional wells and a permitted discharge site. Wastewater Permits Permit Permitted Design Average Annual Maximum Day Receiving Number Capacity Capacity Daily Discharge Discharge Stream Receiving Basin (MGD) (MGD) (MGD) (MGD) NC0083089 0.6000 0.4800 0.3360 Bogue Sound White Oak River (17- 1) 5. Planning Projections Year -Round Population Seasonal Population Residential Commercial Industrial Institutional System Process Unaccounted-for Future Supply Sources Source Name Bogue Banks Water Corporation Demand v/s Percent of Supply 2020 2030 2040 2050 2060 2070 4,995 5,050 5,100 5,150 5,200 5,250 30,000 31,000 32,000 33,000 34,000 35,000 1.2330 1.2400 1.2500 1.2600 1.2700 1.2800 0.2890 0.2900 0.3000 0.3100 0.3200 0.3300 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.3370 0.3400 0.3400 0.3450 0.3450 0.3500 0.0120 0.0900 0.0900 0.0900 0.0925 0.0925 PWSID Source Type Additional Supply Year Online Year Offline Type 04-16-028 Ground 1.0000 2022 Regular 2020 2030 2040 2050 2060 2070 Surface Water Supply 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Ground Water Supply 5.7600 5.7600 5.7600 5.7600 5.7600 5.7600 https://www.ncwater.org/WUDC/app/LWSP/report.php?pwsid=04-16-028&year=2020 4/5 3/3/22, 12:53 PM Purchases Future Supplies Total Available Supply (MGD) Service Area Demand Sales Future Sales Total Demand (MGD) Demand as Percent of Supply lir DWR:: Local Water Supply Planning 0.0000 0.0000 0.0000 1.0000 1.0000 5.7600 6.7600 6.7600 1.8710 1.9600 1.9800 0.0000 0.0000 0.0000 0.0000 0.0000 1.8710 1.9600 1.9800 32% 29% 29% 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 6.7600 6.7600 6.7600 2.0050 2.0275 2.0525 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 2.0050 2.0275 2.0525 30% 30% 30% The purpose of the above chart is to show a general indication of how the long-term per capita water demand changes over time. The per capita water demand may actually be different than indicated due to seasonal populations and the accuracy of data submitted. Water systems that have calculated long-term per capita water demand based on a methodology that produces different results may submit their information in the notes field. Your long-term water demand is 247 gallons per capita per day. What demand management practices do you plan to implement to reduce the per capita water demand (i.e. conduct regular water audits, implement a plumbing retrofit program, employ practices such as rainwater harvesting or reclaimed water)? If these practices are covered elsewhere in your plan, indicate where the practices are discussed here. Are there other demand management practices you will implement to reduce your future supply needs? What supplies other than the ones listed in future supplies are being considered to meet your future supply needs? How does the water system intend to implement the demand management and supply planning components above? Additional Information Has this system participated in regional water supply or water use planning? No What major water supply reports or studies were used for planning? Please describe any other needs or issues regarding your water supply sources, any water system deficiencies or needed improvements (storage, treatment, etc.) or your ability to meet present and future water needs. Include both quantity and quality considerations, as well as financial, technical, managerial, permitting, and compliance issues: The Division of Water Resources (DWR) provides the data contained within this Local Water Supply Plan (LWSP) as a courtesy and service to our customers. DWR staff does not field verify data. Neither DWR, nor any other party involved in the preparation of this LWSP attests that the data is completely free of errors and omissions. Furthermore, data users are cautioned that LWSPs labeled PROVISIONAL have yet to be reviewed by DWR staff. Subsequent review may result in significant revision. Questions regarding the accuracy or limitations of usage of this data should be directed to the water system and/or DWR. https://www.ncwater.org/WUDC/app/LWSP/report.php?pwsid=04-16-028&year=2020 5/5 i i M 04 N 0 0 N / PRODUCTION WELL PW1D 1 Y4" 304/304L SS WATER LEVEL DROP TUBE STICKUP 2.0' 012" CASING LAND SURFACE 36"0 BORE HOLE NEAT CEMENT GROUT (0'-80' BLS) 1 80 30"0 BLACK STEEL SURFACE CASING 1 +' CENTRALIZERS @ 38', 88', 138', 188', 238' 288', 338', 388', 438', 561' ' 1 CEMENT GROUT (0'-415' BLS) ' 22"0 BORE HOLE 1 14"0 SDR17 PVC I 350' CERTA—LOK CASING (0'-350' BLS) I 354' 415' 1 440' I ' 560' 565' 570' 14"X12"PVC TO 1 SS SPLINE ADAPTER (350'-351' BLS) 304/304L SS ELBOW FOR DROP TUBE @ 354' BLS 1 12"0 SCH40S SS 304/304L CASING ' (351'-440' BLS) BENTONITE SEAL ; 1 (415'-420' BLS) 1 12"0 50—SLOT SS SCREEN (440'-560' BLS) #3 GRAVEL PACK (420'-570' BLS) i I , 12"0 SCH10S CELLAR/TAILPIECE (560'-565) LEGEND VERTICAL SCALE GMA SCALE IN FEET 0 25 50 GROUNDWATER MANAGEMENT ASSOCIATES, INC. File: DRAWINGS/24313 PRODUCTION WELL PW1D Date: 2/23/22 Project No. 24313 BOGUE BANKS WATER CORPORATION, EMERALD ISLE, NC Figure: x Tax Parcel Information: Carteret County, N . C . Owner: BOGUE BANKS WATER CORP Current PIN: 632410456539000 Site Address: 0 Mailing Address: EMERALD ISLE NC 28594 Legal Description: CORNER 7TH ST & EMERALD DR r Y 1' _� �';;-t+�_ -�'-_~ �s•�•.�' Yr 'S 'ti Prior PIN:13034BO203 City Limits: EMERALD ISLE ` ;y ,� l ti _ x st .,y'"� w• „�. = _- :ti �,`� ti' � . •"�I L _�} IttIC-�- _ ' - �f - r'15 .'�}5 ��5 SID..4 .•l_..-.� -- i S+'-Y,,� l]+4.Y •rtYf: ti�'• tY � l • {µ� � 45 Y ~ 'X .11 „y t4��, Rescue District: _=;° }- _ - - 4 y 51I�ts= �'I�ltii�kti _ p- _ P. . �__ _ _ ! t,., x, 5i 4~� Y. Y ~'tiI14 '4�' j 'I Fire District: ti ' y' +,yet'' + tii''�- �.c:A__ �r-�+s',,.'. y''1 �ti}��I_ - Tax District: 1556 .ti y� , Xx 'S r ti '4 N—m- 1 ti t Township: WHITE OAK :��_:�•--� ~tip; � �:�ti�, l _� { } - Use: MUNICIPAL EXEMP 1,''y'ykft NBHD: 560041 Land Value: Y - Bldg Htd Sq Ft: Bldg Value: Bldg Tot Sq Ft: o �'•"'�`�' Y + Other Value: Year Built: Total Value: Noise Level: Sale Price: AICUZ Zone: Deeded Acres: 0.309 GIS Acres: 0.302 - Plat Ref: 8 / 70 Roll Type: E N WE Deed Ref: 314 / 6o Deed Date: o Bedrooms: Bathrooms: i in=4i3 ft Printed March=2011 The information displayed by this website is prepared for the inventory of real property found within this jurisdiction and is compiled from recorded deeds, plats, and other public records and data. Users of this information are hereby notified that the aforementioned public primary information sources should be consulted for verification ofthe information contained on this site. Carteret County assumes no legal responsibility for the information contained on this site. Carteret County does not guarantee that the data and map services will be availableto users vdthout interruption or error. Furthermore, Carteret County may modify or remove map services and access methods at will. 3/3/22, 12:54 PM Carteret County, NC Property Record Card Carteret County Property Data Parcel Number: 632410456539000 Inquiry Date: 3/3/2022 DISCLAIMER: For confirmation of the number of buildings on each parcel, please contact the Carteret County Tax Office. Property Info Building Info PARCEL NUMBER: 632410456539000 BATHS: OWNER: BOGUE BANKS WATER CORP BEDROOMS: PHYSICAL ADDRESS 0 CONDITION: MAILING ADDRESS: PO BOX 4009 EXTERIOR WALLS: EMERALD ISLE NC 4009 28594 LEGAL DESCRIPTION: CORNER 7TH ST & EMERALD DR FLOOR FINISH: DEED REF: 314-60 FOUNDATION: PLAT REFERENCE: 8-70 HEAT: NEIGHBORHOOD: 560041 ROOF COVER: SALE DATE: ROOF STRUCTURE: SALE PRICE: $0 SQUARE FOOTAGE: ACREAGE: 0.309 YEAR BUILT: LAND VALUE: $259,173 BUILDING VALUE: $0 EXTRA FEATURE VALUE: $5,133 PARCEL VALUE: $264,306 Sketches Photos https://arcgisweb.carteretcountync.gov/PropertyRecordCard/PropertyDetails.aspx?pin=632410456539000 1/1 ROY COOPER Governor JOHN NICHOLSON In terim Secretary S. DANIEL SMITH Director Mr. Chris Carroll Bogue Banks Water Corp PO Box 4009 Emerald Isle, North Carolina 28594 Dear Mr. Chris Carroll: NORTH CAROLINA Environmental Quality June 29, 2021 RE: Variance Request; Well Sites Bogue Banks Water Corp. Water System No. NCO416028 Carteret County The Public Water Supply Section received a variance request on May 12, 2021 from Mr. Seola Hill, Executive Director of Bogue Banks Water Corporation requesting a variance per 15A NCAC 18C .0203(a)(5) for smaller well lots and reduced separation distances to buildings and surface water for a replacement well located at the existing well 1 and seven (7) additional lots to locate three additional wells at the above referenced water system. The proposed sites were investigated by Mr. Joshua Pack, Engineer II, from the Public Water Supply (PWS) Section. On June 17, 2021, a meeting to address questions about the request was held between Public Water Supply Staff (Joshua Pack, Heidi Cox, and Rebecca Sadosky) and Mr. Seola Hill. The documentation provided by the water system states that they are unable to locate a suitable vacant lot within the service area. They state "It is impracticable to find a qualifying lot given the geography of the island, size and availability of lots, and prices demanded. We have several existing older well sites with smaller dimensions that have been safely in use for many years." During the July 171h meeting, Mr. Hill indicated that the Bogue Banks Water System has an emergency interconnection with the Town of Pine Knoll Shores, but water from the Town of Pine Knoll Shores is not available for regular use during the time frame because it is needed to meet their own periods of peak demand. After reviewing the variance request and meeting with Mr. Hill, we understand existing Well 1 is experiencing saltwater intrusion believed to be from a crack in the casing that has not been located and therefore cannot be repaired. The system has requested approval of a smaller well lot and reduced separation distances in accordance with 15A NCAC 18C .0203(a)(5) and proposes to drill a new well approximately 15 feet west of existing Well 1, located at 701 Emerald Drive. The proposed well location for D_E Q--%� North Carolina Department of Environmental Quallty I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington, North Carolina 28405 N a urq 910.796.7215 replacement of Well 1 will not be in compliance with 15A NCAC 18C .0203(a)(1) or 15A NCAC 18C .0203(a)(2)(D). The existing Well 1 site, as shown on Attachment 1(Map from Variance Request Letter), is approved for a replacement well. We also understand that an additional one or two wells are needed to blend with the existing wells pumping to the existing Reverse Osmosis Plant (Facility name: TREATMENT_PLT_WELLS 4A,5A,8,12 and Facility ID: PRO) to lower the overall chloride levels entering the plant, thereby lowering the pressures, and extending the life of the treatment system. The existing RO plant produces 37% of the water in the summer and 90% in the winter for Bogue Banks Water Corp. Without additional wells, the system states it will have to spend millions of dollars to redo this plant to handle the higher chlorides and resulting elevated pressure. Four sites were proposed in the variance request letter, but the system has since stated that only 1 or 2 are needed. Therefore, we are approving the two proposed sites located at Emerald Landing & Highway 58 and Emerald Landing & Crew Drive in accordance with 15A NCAC 18C .0203(a)(5) and shown on Attachment 2 & 3(Maps from Variance Request Letter). In addition, the water system stated that an additional well site is needed to supply a proposed RO plant that is being constructed to help mitigate intermittent problems with TTHMs in the eastern end of the service area. Three sites were proposed in the variance request letter, but the system stated that one new well site is needed to supply the proposed new RO Plant. The system stated that the variances were needed for the same reasons as stated in the second paragraph above. Therefore, the proposed site located at 7101-7109 Emerald Landing is approved in accordance with 15A NCAC 18C .0203(a)(5) and as shown on Attachment 4(Map from Variance Request Letter). The documentation provided supports that it is impracticable, taking into consideration feasibility and cost, for this water system to locate well sites that meet the requirements of 15ANCAC 18C .0203(a)(1), 15A NCAC 18C .0203(a)(2)(D), 15A NCAC 18C .0203(a)(2)(E) or another approved source of water. The new wells are necessary to continue to meet the existing demands of the current customers during peak summer day demand. In accordance with 15A NCAC 18C .0203(a)(5), the four well lots as described above are approved for new wells to replace existing Well 1 located at 701 Emerald Drive, to supplement blending of the water pumping to the existing RO Plant, and to supply a proposed new RO plant to assist in compliance with TTHMs. Note, the approval of the above four sites for proposed wells is valid until June 25, 2023. If plan approval and authorization to construct are not issued by the PWS Section as specified in 15A NCAC 18C .0301-.0309 by June 29, 2023, the variance granted in this letter is void and the water system will need to submit a new variance request. D E QJ� North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington. North Carolina 28405 v T;�GAFOi 910.796.7215 This PWS Section "Variance Request approval' letter does not address other agency applicable rules and requirements pertaining to well construction and registration. Local county well construction rules and ordinances may include additional requirements. Well construction must meet the standards specified in the Well Construction Standards (15A NCAC 2C). Be aware that these rules require a permit to be obtained from the Water Quality Regional Operations Section of the Division of Water Resources before the wells are constructed if it is anticipated that the new wells will be part of a water system with a design capacity of 100,000 gallons per day or greater. In addition, these rules require that the wells be constructed by a properly certified well driller. For more information contact the Water Quality Regional Operations Section at 919-807-6300 or https://deg.nc.gov/about/divisions/water-resources/water-resources- permits/wastewater-branch/ground-water-protection/well-prop am. If the wells are located in the Central Coastal Plain Capacity Use Area and are projected to supply more than 100,000 gallons per day, they must be permitted prior to construction by the Ground Water Management Branch of the Division of Water Resources. For more information call 919-707-9008 or go to: hnp://www.ncwater.org/PermitsandRegistration/Capaciiy Use/CentralCoastalPlain/ Please do not hesitate to contact me if you have questions or require additional information. Heidi Lane Cox Regional Engineering Supervisor Public Water Supply Section Fayetteville & Wilmington Regional Office attachments CC: Central Files, Public Water Supply Section Joshua Pack, WiRO Public Water Supply Section Mr. Seola NIL Bogue Banks Water Corp. Carteret County Health Department Morella Sanchez -King, Environmental Program Supervisor, Water Quality Regional Operations Mike Ranck-DWR Ground Water Management Branch Chief D E Q�� North Carolina Department of Environmental Quality i Division of Water Resources Wilmington Regional Office 1 127 Cardinal Drive Extension Wilmington, North Carolina 28405 ft�ft NORTH c FIOLI . Attachment 1 701 Emerald Dr —Well 1 1.. i►.: Ail C We currently have a well on this site (W1 Red X). It was our first well and pre -dates size regulations. This is a low producing well (roughly 125gpm) and has been experiencing saltwater intrusion from ground water. We believe there is a crack in the casing somewhere that we cannot find or repair. Being that we've had the well established for so many years, we would like to move over to the West (left) 15' and drill a new well (Blue +). We already had the well videoed and repair one spot in the pipe that we could find. It did not resolve the issue. We will have to abandon the well completely if we cannot redrill to the side. Blue line is 100' radius around proposed new well. The site is 20' above sea level and not in a flood zone. We would like to request a variance on the 100' distance to redrill this well on site. Attachment 2 Emerald Landing and Hwy58 I This lot is along the main drag in Emerald Isle on Hwy58/Emerald Drive between a major commercial business, Transportation Impact, and a major grocery store, Publix. The blue circle is the 100' radius with the blue cross being the proposed well site. The land elevation is 10' above sea level and it is not in a flood zone. We are asking for a variance on the control area. Lot width is 150', so we will need a variance down to 75' radius around the wellhead. Site would be used for the existing RO plant. Attachment 3 Emerald Landing and Crew Dr This lot is similar to the previous one, large enough size but needs a variance from the water. While this lot is more wooded, it has the same elevations in near crew drive and then tapers off to the waterline. There is no seawall on this lot. We'd like to request a variance on the 100' water setback on this site as well. Blue line is 100' radius around proposed new well (Blue +). I split the difference between the property edge and waterline. Any other variation on location will work for us as well. The well site is 14' above sea level and is not in a Flood Zone. We would like to request a variance to the setback from groundwater at this site. Site would be used for the existing RO plant. Attachment 4 7101 to 7109 Emerald Dr This lot is comprised of 5 parcels and is 150' x 425' x 146'x 150'. The blue circle is a 100' radius. The well site is 24' above sea level and not in a flood zone. The well could be placed anywhere inside the lot East to West (left to right). We would like to request a variance on the controlled space around the well head. This is in a neighborhood and a change to the restrictive covenants will be needed to allow use. Site would be used for the new RO plant.