Loading...
HomeMy WebLinkAbout20210372 Ver 1_More Info Requested_20220112Strickland, Bev From: Sent: To: Cc: Subject: Brad, Homewood, Sue Wednesday, January 12, 2022 11:42 AM Brad Luckey Gibby, Jean B SAW Gladstone SD - Request for Additional Information - DWR#20210372 I have one question about the Gladstone SD application. Rd crossing #1 indicates there will be two box culverts, one in alignment with the existing channel which is exactly what we like to see. 51 LF TEMPORARY J COFFER DAM/DIVERSION However, the profile view indicates that both culverts will be set so that the inverts are 1 ft below the existing streambed. i PROPOSED c% GR ADE 80 70 65 r�A 1 1 "Cq LE 6t)x CUL J CLQ.-1 10' AN ix s. 1-8 o� 0.47X VER L sr CULVERT 1 781 780 UPSTREAM INVERT 770.80' EX. STREAM INVERT 771.46' EX. STREAM INVERT 770.86' 770 DOWNSTREAM INVERT 769.70' I 765 77( 76 We require that a floodplain bench be provided at the inlet and outlet of the 2nd culvert so that the stream channel is not widened. Can you please provide updated plan sheets that clearly show that there will be a floodplain bench and/or sill in the culvert to ensure that the channel remains a natural width. Thank you. Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile 2 5ue.Homewood@ncdenr.Aov 4S0VV.Hanes Mill Rd, Suite300 Winston Salem NCZ710S a