Loading...
HomeMy WebLinkAboutNC0076643_Compliance Evaluation Inspection_20220303R.OY COOPER. Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director Mr. Bob Witsell, P.E. Brownfield Project Manager General Electric Company 1935 Redmond Circle NW Rome, Georgia 30165 Dear Mr. Witsell: NORTH CAROLINA Environmental Quality March 3, 2022 Subject: General Electric Hickory Plant Compliance Evaluation Inspection Report NPDES Permit No. NC0076643 1223 Fairgrove Church Road, Hickory Catawba County On February 16, 2022, staff from the Mooresville Regional Office (MRO) performed a site inspection of the Remediation System at the General Electric Hickory Plant to determine compliance with remediation activities as per permit #NC0076643. Enclosed is a copy of the inspection report. At the time of the inspection, the system was online and performing at levels consistent with the active permit for this facility. Laboratory data indicate the system is being effective in the reduction of the TCE and TCA constituents. Continued monitoring of the system is recommended. If you have any questions concerning this matter, please contact Edward Watson at (704) 235-2199 or via email at Edward.Watson@ncdenr.gov. Sincerely, DocuSigned by: 44.0141w H P:ue4 "- F161FB69A2D84A3... Andrew H. Pitner, P.G., Assistant Regional Supervisor Mooresville Regional Office Water Quality Regional Operations Section Division of Water Resources, NCDEQ Attachment: BIMS Inspection Report CC: WQROS Mooresville Regional Office - File Ray Penley ORC, (via email) NO 1:1E RTH CAPOUNA n.n.m.enn of e..iron.Mn.i mwitv North Carolina Department of Environmental Quality 1 Division of Water Resources Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704.663.1699 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 IN I 21IIIIII Code NPDES yr/mo/day Inspection 2 LI 3 I NC0076643 111 12I 22/02/16 117 Type 1810I IIIIIIIIIII Inspector Fac Type 19I S I 2011 IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I1.0 I 70I3 I 71IN I 72 I N I 731 1 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Hickory Plant 1223 Fairgrove Church Rd Hickory NC 28602 Entry Time/Date 10:OOAM 22/02/16 Permit Effective Date 20/12/01 Exit Time/Date 12:OOPM 22/02/16 Permit Expiration Date 25/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Ray S Penley/ORC/828-466-7818/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Ray S Penley,1611 Indian Springs Dr Conover NC 28613/Operator/828-466-7818/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Edward Watson DWR/MRO WQ/ - - / Signaturer.eagb�t:Q A Reviewer Agency/Office/Phone and Fax Numbers Date a3.3. 22 Al FRACIA9nAdAl EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day NC0076643 111 121 22/02/16 I17 Inspection Type 18 [j (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On February 16, 2022, MRO staff performed a Compliance Evaluation Inspection for Permit NC0076643 at the GE Hickory facility. The GW remediation system is the only part of the old facility that still exists. A review of the eDMR records for January 2021 through December 2021, indicates the system is performing within specifications of the permit. The system effluent flow that is less than the permitted flow. Flowmeter calibration is current. The Outfall was viewed during the site visit. No color, foam, solids, or odor were observed in the outfall. Saedacco was present during the site visit for the purpose of constructing 3 new recovery wells. The new wells will be incorporated into the existing treatment system. Page# 2 Permit: NC0076643 Inspection Date: 02/16/2022 Owner - Facility: Hickory Plant Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: The facility is restricted to public access due to the location of the treatment system. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • El El El Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility is clean and well maintained. This is not a WWT system. Therefore, there are no MLSS or MCRT are present as part of this process. A review of the O&M Records for the 2021 year and the records are in order and appear to be complete. Page# 3