Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0043183_Application (FTSE)_20220128
t jWR State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dlvlsion of Water Resources FAST 06-21 & SUPPORTING DOCUMENTATION Application Number: %-0 0,0 \3A2(to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Fitch Creations, Inc. (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Roy B. Fitch. Jr, per l SA NCAC 02T .0106(b) NC Deft of Environment.' Quality Title: President 4. Applicant's mailing address: 2000 Fearrington Village Center JAit City: Pittsboro State: NC' Zip.27312- 9� 4�I1 5. Applicant's contact information: Ralcigh Regional Office Phone number: 919) 42-2000 Email Address: rb aHearrington.com I1. PROJECT INFORMATION: I. Project name: Fearrington Section X Area M 2. Application,'Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00__ and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Chatham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.7946' Longitude:-79.0838" 5. Parcel ID (if applicable): 18998 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I . Professional Engineer: Alan R. Keith License Number: 13371 Firm: Diehl & Phillips. PEA, Mailing address:1500 Piney Plains Road Suite 200 City: CM State: NC Zip: 27518- Phone number: (919) 467-9972 Email Address: arkeith@bellso!ith.net IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Fearrington W WTP Permit Number: NCO043559 Owner Name: Fitch Creations, Inc. V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0036339 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00238 Owner Name(s): Fitch Creations Inc. FORM: FTA 06-21 Page I of 5 Vl. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ®Yes [:]No ❑ N/A 2. if the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? [-]Yes ❑ No ® N'A 3. If the Applicant is a HomelProperty Owners' Association, has an HOArPOA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes [-]No ®N!A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School!" preschool l day care ❑ Medical! dental..' veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 14 ? ®Yes ❑ No ➢ If yes, provide a copy of flow reduction aDgroval letter with this angligation 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,n No. of Units Flow Townhomes 250 galfbedroom 5 1,250 GPD gait GPD gal! GPD gal." GPD gaV GAD gall GPD Total 1,250 GPD a See 15A NCAC 02T .01 14(b). {d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 1.250 GPD (per 15A NCAC 02T .0114 ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: __. _ Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 ViI. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Pumn Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.I .b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 1X. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (g)? ❑ Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall he nrovided for eewer cvarPmc: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches If noncompliance with 02T.0305(f) or (g}. see Section X. I of this application * 15A NCAC 02T.0305(e} contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications web a e 2. Does this project comply with the minimum separation requirements for water mains? ® Yes [—]No ❑ NIA ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ®Yes ❑ No ❑ N;,A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? [:]Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0 I 05(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105,(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). Does this project include any sewer collection lines that are deemed "high -priority?" [:]Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTMCATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting -of Pumv Stations and Force Mains (latest version), and the Gravity Sewer Minimum DI OW Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Agproyal of the request will be issued concurrently with _the approval of the permit. and p iec�equiring a variance approval may be subject to longgr review timesFbirnrolects reanirint two or more variances or where the „variance is determined by the Division to be a significantDortion_of the protect, the hill technical review is required. 2. Professional Engineer's Certification: I, Alan R. Keith attest that this application for F_eanringtan Section X Area M (Professional Engineer's name from Application Item Ill.1.) (Project Name from Application Item il.l ) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria, for Gravity Sewers (latest version), and the Minimum Desi Criteria for the Fast -Track Permittin of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: J •iess/Q 4 , i • a SEALd 13371 a • � 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Roy B. Fitch Jr. attest that this application for Fearrinaton Section X Area M (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item U.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 1 t y :✓Y FORM: FTA 06-21 Page 5 of 5 1 JAN 4 g State of North Carolina Department of Environmental Quality DWRialctdt R�°e`°m (tf�rt Division of Water Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Fitch Creations, Inc. Project Name for which flow is being requested: Fearrington Section X Area M More than one FTSE may be required jar a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Fearrington WWTP _ b. WWTP Facility Permit #: NCO043559 A►1 flows are in MGD c. WWTP facility's permitted flow 0.50 (0.270 constructed d. Estimated obligated flow not yet tributary to the WWTP 0.0549 e. WWTP facility's actual avg. flow 0.165 f. Total flow for this specific request 0.00125 g. Total actual and obligated flows to the facility 0.2150 h. Percent of permitted flow used 79.67 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Average Daily Pump Station Firm Flow** (Name or Capacity, * (Firm 1 p f), Number) MGD MGD Weathersfield 0.90 0.36 (B) (C) (D)-(B+C) (E)-(A-D) Obligated, Approx. Not Yet Total Current Current Tributary Flow Plus Avg. Daily Daily Flow, Obligated Available Flow, MGD MGD Flow Capacity*** 0.14 0.019 0.155 0.205 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Fearrington Section X Downstream Permit Number: WQ0040057 Page 1 of 6 FTSE 04-16 III. Certification Statement: I Roy B. Fitch certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates accentance of this wastewater flow. Signing Page 2 of 6 FTSE 04-16 DIEHL & PHILLIPS, P.A. CONSULTING ENGINEERS WILLIAM C. DIEHL, P.E. 1500 Piney Plains Road Suite 200 JOHN F. PHILLIPS, P.E. Cary, North Carolina 27518 ALAN R. KEITH, P.E. Telephone (919) 467-9972 Fax (919) 467-5327 January 24, 2022 931J3O puoTza-d MgTolT;u Non -Discharge Permitting Unit Division of Water Quality 0 $ ti yr NC DENR 1628 Mail Service Center lenZ%v"1uawuoitAvg3o JdaQ 3N Raleigh, NC 27699-1617 Re: Fast Track Sewer System Extension Application Gravity Sewer Extensions to serve Section X Area M Feanington P.U.D. Chatham County Dear Reviewer: Enclosed for your review are the following for the referenced project: 1. Original and one copy of Gravity Sewer Extension Form & Documents 2. Flow Tracking Form (FTSE) 3. $480.00 Review Fee We request that you approve the proposed permit application. There are 5 residential units associated with the project. The flow associated with the project is 1,250 gallons per day. Should you have questions or require further information, please contact our office. Sincerely, Diehl & Phillips, P.A. NC Alan R. Keith, P.E. Cc: R.B. Fitch nePrOfEnvironmental QuNi ry JAN 28 Ralcigh Regionat office I \ " I- ld'mil /I 1,- .1 - I , r, q IL .1 ( I ) 0 --%. - * .1 . r- if i lk k I .,, VVWLl I 5z r 1?! 77-1 a X� © a N V 7 , OL 43P . . . ....... Vj ILA r)mnu our/ 77 v f Section Section X Area M 00 &0 \L -IM.. . 00) �Zwingt?!i,P. ct!pn-)'L D. Area "a lrl!t ��tham C my y 2L D I qKQi2d s Cop%TVO : 19W VeL amn Yumil IL I LE ON.P% Swri? Dma. U.SGS f .- 04 fs Sr2k 1 6.#30 Dtta* W Datum WG581 m O tL] =r o �. m� 3 X o N v � A fD cn Cl) W C F 1 D � fD O } c� co kz /�1'b NoRTH CARouriA PUBLIC STA" UTII.I'I'IF.S COMMISSION . January 16, 1996 Mr. Allen Keith 219 E. Chatham Street Cary, Forth Carolina 27511 Re: Fearrington Village Chatham County Dear Sir: NC Dept of F.nvironment" quality JAN28it" Raleigh Regional Office This letter is to certify that Fearrington Utilities has been granted a Certificate or Public Convenience and Necessity to provide sewer utility service in the above subdivision under Docket No. W-661, Sub 3. This utility company is under.the jurisdiction of and subject to the requirements of the North Carolina Utilities Commission. If we can be of further assistance to you, please do not hesitate to contract this office. Sincerely, kndb' A )0 An Lee, Director Public Staff - Water Division GL4m EW dV0b&=W ndcadm soammtcRCWWA �acu Tama 7334 z rx�to A--MdA% dw0w6wAr" L3wak rt MUM P0. Bax • Rawsh, North Ca rum 27a&om - F= msI 73$;&5 An Equd opvasdM, / nera—tift Aic&aa EapWW w Entity Names Page 1 of 1 Elaine F. Marshall Secretary ecorporations Home •Mpotiard Nodoe eCorporate Fw= sCo pwad= FAQ oNew Form Not'ioe ,m Verify Certification Links *Secretary Of State Home •Business License "Register for E-Procureme *Dept. of Revenue Legislation 01999 Senate Bins 0=1 Bel Summaries •Annual Reports 1997 OCorporatkxis t997 on Search *w Corporate Name eFor New Corporation 08y PAvIsh ed Agent Onrure orders •Stint An Order North Carolina DEPARTMENT of THE SECRETARY O STATE PO Box 29022 Rsietgh, NC 276264OU (919)607-2000 Date: 7/1 Or= Document Filings Corporation Names Name Fitch Creations. Inc. Business Corporation Information SOSiD: 0053322 Status; Current Active Date Formed: 4/1011961 Clftenship:'Domestic State of Inc.: NC Duration: Perpetual Registered Agent Agent Name: Fddti Jr, Roy B Registered Office 2000 Fean iVon Address; Village Center Pittsboro NC 27312 Registered Mailing 2000 Feanington Address: Vie Ctr Pittsboro NC 27312 N( Principal Offi Address: Principal Mal Address: Bar -Coded Forms For questions or comraests about the North Carviha Secretary of Statet web sft Please send e-maA to Wet For quesfns or comments conceminp the Corporadons Ohrtsian, Please send e-maY to Corporations hUp:/Avww.secrctuy-stftxc.us/Coqorelions/soskbtCmpjLsp?4652064 07/10/2002