Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20211461 Ver 1_More Info Received_20220224
Strickland, Bev From: Ashley Steele Bentz <abentz@smeinc.com> Sent: Thursday, February 24, 2022 12:07 PM To: Cohn, Colleen M Cc: Walter Cole; Lester Lowe; Dave Malinauskas Subject: [External] Golden Pond Attachments: Sheets_2084-CU_C-2.02 Ferbow_Stream_Impact-24x36 Exhibit-02.16.22.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Colleen, see the attached. I will give you a phone call in a few minutes to discuss. Ashley Bentz, PWS Project Scientist BUILT FOR VERSATILITY S&ME 3201 Spring Forest Road Raleigh, NC 27616 map o: 919.954.6285 M: 919.896.0758 www.smeinc.com Linkedln I Twitter I Facebook This electronic message is subject to the terms of use set forth at www.smeinc.com/email. If you received this message in error please advise the sender by reply and delete this electronic message and any attachments. Please consider the environment before printing this email. 1 Ex. SSMH Rim = 319.12 Inv. Out = 313.42 Ex. 8" Sanitary Sewer C� 0.36% to Remain PROPOSED DOGHOUSE SSMH RIM ELEV. = 318.29 EX. Inv. In = 313.29 INV. OUT = 313.29 Ex. 8"Sanitary Sewer 4 0.47% to Remain Ex. 8" Sanitary Sewer 0.36% to Remain PROPOSED DOGHOUSE SSMH RIM ELEV. = 318.29 EX Inv. In = 313.29 INV. OUT = 313.29 PROPOSED 58.4 LF. OF 8" DIP © 0.46% Ex. 8" Sanitary Sewer 0 0.47% to Remain CUT -IN PROPPSED DOGHOUSE SSMH RIM ELEV. = 320.26 SSE INV. IN (E) = 312.92 - INV. IN (N)=313.02 INV. OUT = 312.92 72" CMP W/8" DIP Inv. 316.72 CUT -IN PROP. MH RIM ELEV. = 327.72 EX. Inv. In = 313.33 INV. OUT = 313.33 - Ex. 8"Sanitary Sewer C� 0.32% to Remain coo'vVkv ODIICE \ SF 27.72 SSE \ \_ � I 1 Irk Fence I I f ) / 9 EX. 86.3 LF. OF 8" @ / // 0.48% TO BE REPLACE / / / / / / PERMANENT BUFFER IMPACTS CULVERT SCALE:1" = 20' Channel Invert = 314.22 CUT -IN PROP. MH RIM ELEV. = 327.72 EX. Inv. In = 313.33 INV. OUT = 313.33 - Ex. 8" Sanitary Sewer 0.32% to Remain 72" CMP W/8" DIP Inv.316.72 t N APPROX. 2,000 SQ. FT. \\ of CLASS 2 RIP -RAP Irn Fence �,•� ) EX. 86.3 LF. OF 8" @ / // 0.48% TO BE REPLACE / / 0 10' 20' 40' SCALE: 1 "=20' Ex. SSMH Rim = 319.12 Inv. Out = 313.42 Ex. 8" Sanitary Sewer C� 0.36% to Remain PROPOSED DOGHOUSE SSMH RIM ELEV. = 318.29 EX. Inv. In = 313.29 INV. OUT = 313.29 Ex. 8"Sanitary Sewer / 0.47% to Remain CUT -IN PROPPSED DOGHOUSE SSMH RIM ELEV. = 320.26 _ SSE INV. IN (E) = 312.92 INV. IN (N)=313.02 _ -X INV. OUT = 312.92 \ NOTES: 1. CONTRACTOR SHALL UTILIZE CREEK/DITCH DEWATERING/ BYPASSING AS NEEDED TO PREVENT DAMAGE TO CHANNEL DURING CONSTRUCTION AS WELL AS TO MITIGATE DAMAGE DOWNSTREAM FROM SEDIMENT RUNOFF. CONTRACTOR SHALL FOLLOW GUIDANCE ON CONTRACT SPECIFICATIONS. 2. AFTER CONSTRUCTION ACTIVITIES ARE COMPLETE, OWNER WILL MAINTAIN A 10' PERMANENTLY MAINTAINED MAINTENANCE CORRIDOR AT STREAM CROSSING. 3. CONTRACTOR TO ADJUST DEPTH OF RIP -RAP OVER SANITARY SEWER PIPE AS NEEDED TO AVOID CONTACT B/W ROCK AND PIPE TOTAL LIMIT OF DISTURBANCE: 0.26 AC - CUT -IN PROP. MH RIM ELEV. = 327.72 EX. Inv. In = 313.33 INV. OUT = 313.33 Ex. 8" Sanitary Sewer 0 0.32% to Remain Ir\oinjFence EX. 86.3 LF. OF 8" @ / // 0.48% TO BE REPLACE / W/8" DIP // Channel Invert = 314.22 TEMPORARY BUFFER IMPACTS CULVERT SCALE:1" = 20' RE -ALIGNED 8" SANITARY SEWER INSTALL GEOTEXTILE FABRIC. CONTRACTOR TO ENSURE FABRIC IS ANCHORED A MIN. OF 12-INCHES AT GRADE TIE-IN LOCATIONS STREAM / BUFFER IMPACTS ZONE PERMANENT TEMPORARY S.F. ACRES S.F. ACRES RB Z1 2,381 0.055 7,416 0.17 RB Z2 N/A N/A 718 0.02 STREAM LINEAR FEET 55 LEGEND BUFFER Z-1 PERMANENT / BUFFER TEMPORARY Y �jA BUFFER Z-1 TEMPORARY NEW RIPRAP AREA - CLASS 2 LENGTH=54 LF. (39 LF. MIN. REQ'D.) CLASS 2 RIP -RAP DISSIPATOR INSTALL CLASS 2 RIP -RAP APRON (2,000 SQ. FT. x 2.7' DEPTH*) PROPOSED GRADE Existing Grade Ex. Pipe Invert = 316.72' PROPOSED 8" DIP. GRAVITY SEWER Channel Invert = 314.22' Ex. Sewer to be Re -Aligned Exist. Creek Centerline PROFILE @ STREAM CENTERLINE SCALE:1" = 20' Ex. 8" Sanitary Sewer «/ 0.36% to Remain PROPOSED DOGHOUSE SSMH RIM ELEV. = 318.29 EX Inv. In = 313.29 INV. OUT = 313.29 PROPOSED 58.4 LF. OF 8" DIP © 0.46% Ex. 8" Sanitary Sewer Cap 0.47% to Remain - S CUT -IN PROPPSED DOGHOUSE SSMH 7 SSE - RIM ELEV. = 320.26 INV. IN (E) = 312.92 \ INV. IN (N)=313.02 - - INV. OUT = 312.92 \ / . \ \ Tiro ence - CUT -IN PROP. MH RIM ELEV. = 327.72 EX. Inv. In = 313.33 INV. OUT = 313.33 - Ex. 8" Sanitary Sewer @ 0.32% to Remain 27-72- - EX. 86.3 LF. OF 8" @ / // 0.48% TO BE REPLACE 72" CMP W/8" DIP Inv. 316.72 t \/ I I \ \\I APPROX. 2,000 SQ. FT. of CLASS 2 RIP -RAP - Ex. SSMH No Action J / / / / / / / / / / / 72" CMP STREAM / BUFFER IMPACTS ZONE PERMANENT TEMPORARY S.F. ACRES S.F. ACRES RB 21 199 0.004 3,108 0.07 RB 22 N/A N/A 3,067 0.07 STREAM LINEAR FEET 19 LEGEND BUFFER Z-1 PERMANENT BUFFER Z-2 TEMPORARY BUFFER Z-1 TEMPORARY FINAL DRAWING FOR REVIEW PURPOSES ONLY M c) 0 I` N U z Q) .0 az • a) a) Q co O m L O z 0 N E O U >, co E O U a) 0 a) • M L!� 00 N CO O rn License Number : F-0115 TOWN OF CREEDMOOR NORTH CAROLINA GRANVILLE COUNTY FERBOW STREET GRAVITY SEWER IMPROVEMENTS DESIGNED BY: DRS DRAWN BY: DRS CHECKED BY: AMW PROJECT NO.: 2084-CV DATE: AUGUST 2021 SCALE: AS NOTED VERT.: AS NOTED 0 /2 1 IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE PERMANENT BUFFER IMPACTS STORM DRAINAGE SCALE:1" = 20' 0 10' 20' 40' SCALE: 1 "=20' TEMPORARY BUFFER IMPACTS STORM DRAINAGE SCALE:1" = 20' C-2.O.2