Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW6220202_Stormwater Report_20220223
underfoot ENGINEERING STORMWATER REPORT for MESSER PARCELS Prepared for: T&L COATS, LLC 165 SOMMERVILLE PARK ROAD RALEIGH, NC 27603 Underfoot Project #: C21020.00 1 S' Submittal: November 17, 2021 Y CA 0O�OFESS/0, J, .� SE �. r 326 4 ; W 2021.11.17 ���Q F,GIN °` NM . LO Landon Lovelace, PE 1 149 Executive Circle, Suite C-1 Cary, NC 27511 NCBELS # C-3847 1 919.576.9733 Forward Thinking. Grounded Design. www.underfootengineering.com underfoot ENGINEERING 1149 Executive Circle - Suite C-1, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 TABLE OF CONTENTS TABLEOF CONTENTS................................................................................................................. 1 1. INTRODUCTION AND BACKGROUND................................................................................. 3 1.1 PROJECT INFORMATION AND DATA.................................................................... 3 1.2 STORMWATER MANAGEMENT REQUIREMENTS.................................................... 4 1.3 PROJECT DESCRIPTION......................................................................................... 5 2. STORMWATER CALCULATIONS........................................................................................... 6 2.1 METHODOLOGY.................................................................................................... 6 2.2 CONCLUSIONS...................................................................................................... 7 APPENDIXA: MAPS................................................................................................................A FEMAFIRM PANEL.........................................................................................................A DRAINAGEAREA MAPS................................................................................................A SOILSMAP.....................................................................................................................A APPENDIX B: SCM CALCULATIONS....................................................................................... B SCMSIZING................................................................................................................... B SCMROUTING............................................................................................................... B O&M MANUAL.............................................................................................................. B APPENDIX C: CONVEYANCE CALCULATIONS......................................................................0 PIPESIZING....................................................................................................................0 GUTTERSPREAD............................................................................................................0 HGLANALYSIS...............................................................................................................0 SWALECALCS...............................................................................................................0 DISSIPATORS..................................................................................................................0 APPENDIX D: ENVIRONMENTAL EVALUATION....................................................................... D Forward Thinking. Grounded Design. www.underfootengineering.com underfoot ENGINEERING 1149 Executive Circle - Suite C-1, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 1. INTRODUCTION AND BACKGROUND 1.1 PROJECT INFORMATION AND DATA Messer Parcels is a 12.25 acre property on which a fourty-two (42) single family unit development is being proposed. The Harnett County parcel identification number(s) (PIN(s)) for the site is 0690-85-7606, 0690-85-5523, 0690-85-4624, and 0690-85-3459. The property is located in Coats, NC at NC Highway 27 directly across from E. Stewart Street. The site is mostly wooded and consists of old residential/farming structures, an existing wellhouse, small gravel driveways, and existing sanitary sewer strucuures and mains. The total area of land disturbance on site for the project is 10.95 Acres. The terrain is rolling, all sloping towards the northwest corner of the site. The property is located within the Town of Coats in Harnett County, zoned R-6 for all existing parcels within the site, with the exception of parcel 0690-85-3459 which is zoned C-3, which must be rezoned concurrently with plan approval. The site is in the Cape Fear Watershed / Upper Black River Sub Basin (HUC 030300060101). There are no FEMA mapped flood plain per FIRM Panel 372006800J, effective date October 3, 2006. There is no buffered stream on the property, however there are wetlands on site (0.884 ac) per the preliminary environmental delineation prepared by Sage Ecological Solutions, INC on June 25, 2021. A copy of that preliminary sketch is included in Appendix D and the consultant has reached out to the necessary agencies for concurrence. Forward Thinking. Grounded Design. www.underfootengineering.com 3 WIW underfoot 1i ENGINEERING FIGURE 1: AERIAL VIEW OF THE SITE 1149 Executive Circle - Suite C-1, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 1.2 STORMWATER MANAGEMENT REQUIREMENTS This project is subject to the regulations set forth in the North Carolina Department of Environmental Quality (NCDEQ) Post Construction Stormwater Program. As a high -density project, the proposed development will be required to meet Chapter A-1 of the NCDEQ Stormwater Design Manual treatment requirements. Additionally, the project shall meet the Erosion Control requirements as set forth by NCDEQ. The purpose of this report is to demonstrate the site's proposed compliance with all stormwater regulations and to provide supporting documentation to that effect. The Stormwater Runoff Control requirements of the Stormwater Program state that the Minimum Design Criteria (MDC) for infiltration systems is that they shall control and treat the difference in stormwater runoff rate leaving the project site between the pre- and post -development conditions for the 1-year, 24-hour storm. The design volume shall be drawn down 72 hours or less. Additionally, any structural stormwater system must treat the run-off to remove 85% total suspended solids (TSS). Calculations were run to identify the peak flows for the design storm under the existing conditions, as well as after the proposed build out for the point Forward Thinking. Grounded Design. www.underfootengineering.com 4 � _ddw 1149 Executive Circle -Suite C-1, Cary, NC 27511 u n d e rf o of 919.576.9733 1 NCBELS C-3847 `W ENGINEERING of Interest. An on -site wet pond will be used to mitigate the increase in run-off associated with the proposed development. The following section outlines how all stormwater requirements are being met. For construction phase erosion and sedimentation control requirements, the site shall use a series of measures in order to meet all applicable NCDEQ requirements to prevent erosion and off -site sedimentation. Those requirements include the use of silt fencing, diversion berms/ditches, skimmer sediment basins, and other measures as required. The erosion control calculations can be found on the construction plans. 1.3 PROJECT DESCRIPTION The proposed development includes the necessary roadway, utility, and stormwater infrastructure to create forty-two (42) single family homes. After construction, the project will consist of impervious area for roadways, driveways, sidewalks, and roofs as well as managed pervious areas (lawns and landscaping). The project site work will be done in compliance with Town of Coats, NCDEQ, NCDOT, Harnett County, and Harnet Regional Water requirements as well as other regulatory agency requirements. Forward Thinking. Grounded Design. www.underfootengineering.com 5 underfoot ENGINEERING 2.1 METHODOLOGY 1149 Executive Circle - Suite C-1, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 2. STORMWATER CALCULATIONS This stormwater study was conducted using the natural drainage features and existing impervious areas as depicted by an existing field survey provided by Robinson & Plante, PC, as well as the proposed impervious areas based on the site design. Drainage areas were based on field survey and GIS data and proposed development within those drainage areas. The scope of work included the following analyses: Hydrology: Formulation of the 1-year peak flow for the pre -development and post -development drainage areas were generated with HydroCAD. The SCS Method was used to develop peak flows for the Type II, 24-hour storm events in the Town of Coats area. This method requires three basic parameters: a weighted curve number (CN), Rainfall Depth (P), and drainage area in acres (A). The curve number values, and drainage areas were computed using information taken directly from the field survey and GIS information and TR-55 Table of Curve Numbers. The rainfall depth was determined from the NOAA Atlas 14 rainfall data for Coats, NC. Hydraulics: Computer simulated reservoir routing of the 1-year, 2-year, 25-year, and 100-year design storms utilized stage -storage and stage -discharge functions was completed in HydraFlow. Stage -storage functions were derived from the proposed grading of the proposed SCM. A non -linear regression relation for surface area versus elevation was derived for the SCM. This relation estimates the incremental volume of the basin to the stage or elevation of the basin. Stage -discharge functions were developed to size the proposed outlet structure for the SCM. The resulting pre -development and post - development flows out of the proposed SCM and for untreated areas are then analyzed to ensure that there is no increase in flow for all required design storms. Forward Thinking. Grounded Design. www.underfootengineering.com 6 underfoot 1149 Executive Circle -Suite C-1, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 ENGINEERING The HydraFlow modeling results are provided as appendices to this report. Piped conveyance systems were analyzed in StormCAD using the rational method. Gutter spread was calculated for the 4"/hour storm, with a maximum allowable gutter spread of 7.5'. Pipes were sized for the 10-year storm and all Hydraulic Grade Lines for the 10- year storm are within the pipe. Drainage Swales were analyzed using a spreadsheet tool and the results are provided as appendices to this report. 2.2 CONCLUSIONS The final SCM design is based on the Simple Method for the First 1 " volume calculation and NCDENR's SCM Manual account for the attenuation required to ensure that the site meets the pre -post requirement for peak flow. Based on the routing study, the proposed basin has sufficient volume to safely pass the 100-year storm without overtopping the dam. The outlet was designed to discharge the runoff resulting from the first 1 " of rainfall over 2 to 5 days to meet water quality guidelines. There is no proposed increase in peak runoff, for the site as a whole and at each study point, for any of the design storms. Per the SCM Manual, a wet detention basin removes 85% TSS, which meets the required 85% TSS removal. Please refer to Appendices for all supporting calculations and documentation. Forward Thinking. Grounded Design. www.underfootengineering.com 7 mftlpp'-44� iw underfoot ENGINEERING APPENDIX A: MAPS FEMA FIRM PANEL DRAINAGE AREA MAPS SOILS MAP 1149 Executive Circle, Suite C-1 Cary, NC 27511 NCBELS # C-3847 1 919.576.9733 Forward Thinking. Grounded Design. www.underfootengineering.com 2080000 FEET 2100000 FEET 620000 FEET 78°43'30"W 78°43'0"W 78°42'30"W 78°42'0"W 78°41'30"W 78°41'0"W 78°40'30"W 78°40'0"W 620000 FEET Chested f`" _ /d<a�PR"b "�. � �,,,�, .� l Neste ,i"�l .:• •� � 5� E�Z0412 �a�'. � � s - ell y; / Black 35°27'0"N 35°27'0"N r. a � ' + .� ..-•.WendyC„ .� �•!'yi/-e dyorSeR4h Rd River - Sl`asHa`les �y Cty , — '3 � Gti � Wild Winds Ur4 y �s Se A 1213 ZONE AE CD 119, 1_4 1 55 c 35°26'30"N i. > 1 F :� v ti^�� 35°26'30"N r"AAwb ows N1. '►.. 1 •;.: / G,.a''a w _ jet � t� �S' 1 ' � r d� Z a�eO ?. � 1. ��1�"' �. 0. • i� � �_ -! . � 11 �,� � .. - l Buies o' ar • `�1• �_ ��,o loyal Anne � ''_ � : + ��.. 1 � Creek , � • � � � i7,� ox��o �' m �m i O Q• 1 �o• r. 35°26'0"N Violet Ln a 35°26'0"N .�In,_ '�s � Pepsi Ln � ' .. ` ► AV Z e � r 2+ 3 ..� 96,5 ! x.� �y�; _ �'►► O � c:_ F of �1.. u n nir���-r.�-r rnr mrrr�v _ 2 �ierel_ 1 :•, �i G� �,, l 1111�1 Wli 1 V V V 1 V 1 � _. rn yr �_ rY LTL�TINC©RPORATED AREAS x ," - `� `� 35°25'30"N 35°25'30"N . � '+V;•�'• ,� ` a ei'o aae � I,�j � 1 r • - r rs'S / r b c ,Run I 2, • 'J'` �' r• e � P 3703 8 6 I •. } 'Birch Acres Ln ' Ro cky` Br�ahch Eta +' ` y L • �9S MemorY Birch Grove �4i' c � 1� • P Ln - plasO���e ZONE AE 146 4 89.9 kt rbrnOrr ter. tee` � t `"`1 - 4 i ti �4L 35°25'0"N = i - �. 35°25'0"N {U. oa st 'hayb 27 , _ ..!1 - `A• Y — 3 B. U P� Pry s �. �; � .f i - . ' ° J } + - �' - c ��� • lot- '.401 ,. Kimbery iPis ' � , ;';, �. a•. _ m` uoi _ att St + pr W o ■ r0S �� ��• - .. PVe �.'�Q•,j ^� r ..L 1Stewa t St 27- Ki,. 4.5 1 be\\ . �.\'�_I�' 27 =�+ mS► L ilt - • u Ka• OFzid[Y,, w E Williams St `ike•` :4 1: �....,w '' 4 S W Lisa-Zt • ej ass. -a ;'i -r�;. �.�. �Y ,i • ,' �'� �•r,���,p�n;�� ',� �;�,�:,t,:- a I Clayt Pon C r j y1 Fast Buies c, - s a 3 y 6�'9 m / Sr f .. ; '!i, •�. � 3•. � a E Uooley St art_ptw4nq f ♦ qrb� �4CrPf �o �Yir+rt iy W Lemon St, E Lemon St - .s • sr' a.� R 1 35°24'30"N f t °1 J roc Z 35°24'30"N ` :. '! t �' c�' E Main St 158-2 b T! `L+ Frei t *�.. ram' ,.1 - y y E Washington St +�y� shoo �� : _ 1 � Fleming Rd � w Washington St ` c r • _ - ���, -. � �.,-y � � in E Jackson St b4� W Jackson St m y o way'<< - � _ i a •t v � E Ramer41 at <• Jay J * W Penny Stul St rn R c �'"' I - `� � y •R E Parrish St o �•r ..� � �' e I � W Parrish St rY t m R N -.t p^ � wsournst E South Sto w N @Ta W Erwin St •_ � E Lynn St Mclamb Rd a E Erwin St \�Q- a 55 RAI es t" � c� [• Yr �Xo�a ,� if Dunn St 35°24'0"N 35°24'0"N f, . � 1. �rys ;. �� ',� G,a% E Uurane Ur T r O :nL n ` r•�� 600000 FEET r. �• �r. ' 600000 FEET 78°43'30"W 78°43'0"W 78°42'30"W 78°42'0"W 78°41'30"W 78°41'0"W 78°40'30"W 78°40'0"W 2080000 FEET 2100000 FEET FEMA'S COOPESA'i1NG TECHNICAL PAFM4EF1 This digital Flood Insurance Rate Map (FIRM) was produced through a unique cooperative partnership between the State of North Carolina and the Federal Emergency Management Agency (FEMA). The State of North Carolina has implemented a long term approach to floodplain management to decrease the costs associated with flooding. This is demonstrated by the State's commitment to map flood hazard areas at the local level. As a part of this effort, the State of North Carolina has joined in a Cooperating Technical State agreement with FEMA to produce and maintain this digital FIRM. FLOOD HAZARD INFORMATION NOTES TO USERS SCALE SEE FIS REPORT FOR ZONE DESCRIPTIONS AND INDEX MAP THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTING DOCUMENTATION ARE ALSO AVAILABLE IN DIGITAL FORMATAT HTTP://FRIS.NC.GOV/FRIS Without Base Flood Elevation (BFE) Zone A,V, Hy With BFE or Depth zone AE, AO, AH, VE, AR SPECIAL FLOOD Regulatory Floodway HAZARD AREAS 0.2% Annual Chance Flood Hazard, Areas of 1% Annual Chance Flood with Average Depth Less Than One Foot or With Drainage Areas of Less Than One Square Mile zone x Future Conditions 1% Annual Chance Flood Hazard zone x OTHER AREAS OF Area with Reduced Flood Risk due to Levee FLOOD HAZARD See Notes zone x OTHER Areas Determined to be Outside the AREAS `' 0.2% Annual Chance Floodplain zone x ------------- Channel, Culvert, or Storm Sewer Accredited or Provisionally Accredited GENERAL Levee, Dike, or Floodwall STRUCTURES i i i i i i i i i i i i i Non -accredited Levee, Dike, or Floodwall BM5510 X North Carolina Geodetic Survey bench mark BM5510 ® National Geodetic Survey bench mark BM5510� Contractor Est. NCFMP Survey bench mark 012 1s-2— Cross Sections with 1% Annual Chance Water Surface Elevation (BFE) Coastal Transect --- -- - Coastal Transect Baseline Profile Baseline Hydrographic Feature OTHER Limit of Study FEATURES Jurisdiction Boundary For information and questions about this map, available products associated with this FIRM including historic versions of this FIRM, how to order products or the National Flood Insurance Program in general, please call the FEMA Map Information eXchange at 1-877-FEMA-MAP (1-877-336-2627) or visit the FEMA Map Service Center website at http://msc.fema.gov. An accompanying Flood Insurance Study report, Letter of Map Revision (LOMR) or Letter of Map Amendment (LOMA) revising portions of this panel, and digital versions of this FIRM may be available. Visit the North Carolina Floodplain Mapping Program website at http://www.ncfloodmaps.c( or contact the FEMA Map Service Center. Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well as the current FIRM Index. These may be ordered directly from the Map Service Center at the number listed above. For community and countywide map dates refer to the Flood Insurance Study report for this jurisdiction. To determine if flood insurance is available in the community, contact your Insurance agent or call the National Flood Insurance Program at 1-800-638-6620. Base map information shown on this FIRM was provided in digital format by the North Carolina Floodplain Mapping Program (NCFMP). The source of this information can be determined from the metadata available in the digital FLOOD database and in the Technical Support Data Notebook (TSDN). ACCREDITED LEVEE NOTES TO USERS: If an accredited levee note appears on this panel check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. PROVISIONALLY ACCREDITED LEVEE NOTES TO USERS: If a Provisionally Accredited Levee (PAL) note appears on this panel, check with your local community to obtain more information, such as the estimated level of protection provided (which may exceed the 1-percent-annual-chance level) and Emergency Action Plan, on the levee system(s) shown as providing protection. To maintain accreditation, the levee owner or community is required to submit the data and documentation necessary to comply with Section 65.10 of the NFIP regulations. If the community or owner does not provide the necessary data and documentation or if the data and documentation provided indicates the levee system does not comply with Section 65.10 requirements, FEMA will revise the flood hazard and risk information for this area to reflect de -accreditation of the levee system. To mitigate flood risk in residual risk areas, property owners and residents are encouraged to consider flood insurance and floodproofing or other protective measures. For more information on flood insurance, interested parties should visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. LIMIT OF MODERATE WAVE ACTION NOTES TO USERS: For some coastal flooding zones the AE Zone category has been divided by a Limit of Moderate Wave Action (LiMWA). The LiMWA represents the approximate landward limit of the 1.5-foot breaking wave. The effects of wave hazards between the VE Zone and the LiMWA (or between the shoreline and the LiMWA for areas where VE Zones are not identified) will be similar to, but less severe than those in the VE Zone. Limit of Moderate Wave Action (LiMWA) COASTAL BARRIER RESOURCES SYSTEM (CBRS) NOTE This map may include approximate boundaries of the CBRS for informational purposes only. Flood insurance is not available within CBRS areas for structures that are newly built or substantially improved on or after the date(s) indicated on the map. For more information see http://www.fws.gov/habitatconservation/coastal_barrier.html, the FIS Report, or call the U.S. Fish and Wildlife Service Customer Service Center at 1-800-344-WILD. CBRS Area Otherwise Protected Area Map Projection: North Carolina State Plane Projection Feet (Zone 3200) Datum: NAD 1983 (Horizontal), NAVD 1988 (Vertical) 1 inch = 1,000 feet 1:12,000 0 500 1,000 0 150 300 PANEL LO CATO R CHATHAM COUNTY LEE COUNTY 2,000 Feet Meters 600 WAKE COUNTY 0624 JOHNSTON COUNTY 0602 1 0622 1 0642 1 0662 1 0682 111602 9680 1 0600 1 0620 1 0640 1 0660 9548 1;9568 1 9588 1 0508 1 0528 1 0548 1 0568 HOKECOUNTY 9566 1 9586 1 0506 1 0526 1 0546 1 0566 9564 1 9584 1 0504 1 0524 62 [oilLTA 1.14.1I:1►1Zd11111► 1 1600 �-1 1620 1506 I --I _ 1546 1504 _J 1524 SAMPSON COUNTY NORTH CAROLINA FLOODPLAIN MAPPING PROGRAM NATIONAL FLOOD INSURANCE PROGRAM cc FLOOD INSURANCE RATE MAP NORTH CAROLINA ^F� y. 0. PANEL 0680 v a+vo SEG�a v) FEMA �, w* Panel Contains: COMMUNITY CID PANEL SUFFIX COATS, TOWN OF 370558 0680 1 trr ► M HARNETT COUNTY 370328 0680 1 i U. 0 cc Z MAP NUMBER 3720068000J MAP REVISED 10/03/06 `USGS U.S. DEPARTMENT S. GEOLOGICAL GIICAL SURV YERIOR science for a changing world -78.7500' 35.5000 ` 70500om E 06 07 3930000m N 27 26 25 24 23 22 21 20 19 18 17 35.3750° -78.7500' 09 The National Map USTopo 10 11 12 13 14 COATS QUADRANGLE NORTH CAROLINA 7.5-MINUTE SERIES 05 06 07 08 09 10 11 12 13 14 715000-E Produced by the United States Geological Survey SCALE 1:24 000 MN, . North American Datum of 1983 (NAD83) World Geodetic System of 1984 (WGS84). Projection and N 1 0.5 0 KILOMETERS 1 2 1 000-meter grid: Universal Transverse Mercator, Zone 175 1000 500 0 METERS 1000 2000 This map is not a legal document. Boundaries may be 9°14 generalized for this map scale. Private lands within government 164 MILS 1 0.5 1°20" � 0 1 reservations may not be shown. Obtain permission before 24 MILS MILES entering private lands. 1000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Imagery .....................................................NAIP, May 2016 - November 2016 FEET Roads ......................................... U.S. Census Bureau, 2016 UTM GRID AND 2019 MAGNETIC NORTH Names............................................................................GNIS, 1980 - 2019 DECLINATION AT CENTER OF SHEET Hydrography...............................National Hydrography Dataset, 1899 - 2018 CONTOUR INTERVAL 10 FEET Contours............................................National Elevation Dataset, 2008 U.S. National Grid NORTH AMERICAN VERTICAL DATUM OF 1988 Boundaries ..............Multiple sources; see metadata file 2017 - 2018 100,000 - m Square ID Wetlands.................FWS National Wetlands Inventory 1983 This map was produced to conform with the OV National Geospatial Program US Topo Product Standard, 2011. A metadata file associated with this product is draft version 0.6.18 Grid Zone Designation 17S NORL-I ARO A QUADRANGLE LOCATION 1 Fuquay-Varina 1 2 3 2 Angier 3 Edmondson 4 Lillington 4 5 5 Benson 6 Bunnlevel 6 7 8 7 Erwin 8 Dunn ADJOINING QUADRANGLES -78.6250` 15 35.5000' 31 ix 29 28 27 26 25 24 23 22 21 20 19 391 8000m N -78.6250' 35.3750' ROAD CLASSIFICATION 0 Expressway Local Connector Cl) Secondary Hwy _ Local Road to cn cn Ramp 4WD 00 rn • Interstate Route US Route O State Route �Y M N �x �U) o(D c+) j CD Z LL W COATS, NC y< 2019 z z O N (D N U V) w w x C� Z_ Q n Q 0 U V) J W U Q d m w V) V) w O N O N U N O N N U w CL a J_ U X E POST DAl _ S 882540"' E 491� (TOTAL UNDETAINED 234.43—� . AREA = 2.65 ACRES :.... 9 CN = 67 *POI;,-'..... TOC = 5 MIN. a • • DVA�NAGE. Al2 A- I AT RROVERTYLIN CD �(ifI = 0 — — _ . ___ �} �.. ./..... _ I - STM 142 -- I ; — \J' 7 STM 1 L— — — — — -- `STM 140 — — — N-8Z24 1 — -- _ W W— (T1EJ CL ! \ SM 1 I L— ---- I _ I N — � I I I— 03 — — _ I o • 1 — — — — — J L — — — �. ¢— — STM 1 4 3 — — 1 = l== S 131 -- _ L - - - - - I I �. I. . . . . . o - ---� STM 1 51 - a PP I W 265.95 ; ; i 3 I 107 699FTOF — ,1- r -----I STM 6 I ,% CHANNEL --- FLOW— ... I II a 1 1 T 133 ;� _ 3 r--- --- ---- , --- � S1M 3 L-- ---I POST DA 1 AREA = 9.61 ACRES CN=72 TOC = 5 MIN. 1 � J w U — — - N a — -- `• ,-- I I \ I !� — — S 8 4055 E 133.83' (TY) W ,1 i--- 3t S_ A -- o I STM 10 $Y — ---- 1 N a I — S 109 3: o / Q) i i - I Zcn 258 FT OF a SHALLOW '\ I �► I I I I ,\ BW 301.36 L c� CONCENTRATED z — — I FLOWCD I \ ro \ Zoo a ll% M 1 I 5-- I133 14 �� g 0 91 J // 19 Z I I I 57 'p0 / p+502p+69 p3 / 913 ----- --_/ I 75 FT OF SHEET FLOW w� -- --1 —� — / TM 1 ON Ur, LQ ON N Uri ON ON I '� • 5 I _ ON ON ON I `r IIN ?Uploo 1 Ln � 0 0 \ I S 300 ON/ k0AS WIDENING LIMITS OF DISTURBANCE SON � PLAN REVISIONS # DATE I REVISION I BY KNOW WHAT'S BELOW ALWAYS CALL 811 BEFORE YOU DIG It's fast. It's free. It's the law. PROJECT: MESSER PARCELS 187, 203 & 249 EAST STEWART STREET COATS, INC PROJECT #: C21020 DRAWN BY: ZA REVIEWED BY: ILL 1ST SUBMITTAL: 2021.1 1.17 SCALE: AS NOTED PRELIMINARY NOT FOR CONSTRUCTION PREPARED FOR T&L COATS, LLC 165 SOMMERVILLE PARK ROAD RALEIGH, NC PREPARED BY: underfoot ENGINEERING 1 149 EXECUTIVE CIRCLE CARY, NC 27511 P:919.576.9733 NCBELS # C-3847 SEALED: \��111111111/�,� \ �O• �OFESS%p 7 = r ° 03267400 w = ''' 11,11110 0 "2021,11,17 SHEET: POST - DA MAP O N (D N U V) w w x C� Z_ Q n Q 0 U V) J W U Q d m w V) V) w O N O N U N O N N U w CL a J_ U X NoB W ► t - .i i + r z- a �, � w g b Alm • � N ? - Bb� i NoB — ,art jr . f - • ay, •1 .- � I � � } -•w i^'ti r'l- I+F � � �� _ III ' �1 ��r � i �•am ti �i,��,.4 "� .3�K { �' - 1 � +',Ile, FA owl. IL .L s Statel"ivwv NaB r� r k ` �.. ` -0 � + +T - i'r • _` ��' ^I.-2. g Jo MAP LEGEND Area of Interest (AOI) 0 Area of Interest (AOI) Soils 0 Soil Map Unit Polygons rwr Soil Map Unit Lines 0 Soil Map Unit Points Special Point Features Vo Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit .14 Gravelly Spot 0 Landfill Lava Flow Marsh or swamp + Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot 4 Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip oa Sodic Spot Soil Map —Harnett County, North Carolina (Messer Parcels) MAP INFORMATION Spoil Area The soil surveys that comprise your AOI were mapped at 1:24,000. Stony Spot Very Stony Spot Warning: Soil Map may not be valid at this scale. Wet Spot Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil Other line placement. The maps do not show the small areas of .- Special Line Features contrasting soils that could have been shown at a more detailed scale. Water Features Streams and Canals Please rely on the bar scale on each map sheet for map measurements. Transportation Rails Source of Map: Natural Resources Conservation Service Web Soil Survey URL: rwr Interstate Highways Coordinate System: Web Mercator (EPSG:3857) US Routes Maps from the Web Soil Survey are based on the Web Mercator L Major Roads projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Local Roads Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. Background . Aerial Photography This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Harnett County, North Carolina Survey Area Data: Version 18, Sep 1, 2021 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Oct 22, 2018—Oct 25, 2018 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. USDA Natural Resources Web Soil Survey 11/17/2021 Conservation Service National Cooperative Soil Survey Page 2 of 3 Soil Map —Harnett County, North Carolina Messer Parcels Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI Bb DoA Bibb soils, frequently flooded 17.3 19.8 11.3% 12.9% Dothan loamy sand, 0 to 2 percent slopes FaB Fuquay loamy sand, 0 to 6 percent slopes 3.4 2.2% NoB Norfolk loamy sand, 2 to 6 percent slopes 66.4 43.1 % NuB Norfolk -Urban land complex, 0 to 6 percent slopes 15.4 10.0% W Water 0.4 0.2% WaB Wagram loamy sand, 0 to 6 percent slopes 1.9 1.3% WaC Wagram loamy sand, 6 to 10 percent slopes 29.3 19.0% Totals for Area of Interest 153.8 100.0% UusDA Natural Resources Web Soil Survey 11/17/2021 Conservation Service National Cooperative Soil Survey Page 3 of 3 APPENDIX B: SCM CALCULATIONS underfoot ENGINEERING SCM SIZING SCM ROUTING O&M MANUAL 1149 Executive Circle, Suite C-1 Cary, NC 27511 NCBELS # C-3847 1 919.576.9733 Forward Thinking. Grounded Design. www.underfootengineering.com PROJECT INFORMATION DRAINAGE AREA INFORMATION C-3: WET DETENTION BASIN DESIGN Project Name: WET POND 1 Project Location: Drainage Area 1 Project Number: C21020 Date: 1 11/17/2021 Project Designer: EB Checked By: LL Drainage Area Name: DA1 Drainage Area (DA) =[tl 8,798 SF Impervious Area (IA) =9,978SF Percent Impervious (1) =40.59 % Water Quality Design Storm = 1 INCHES) REQUIRED STORAGE VOLUME - SIMPLE METHOD Determine Rv Value = 0.05 + 0.009 (1) = 0.42 IN/IN Storage Volume Required = 14,493 CF Based on Simple Method REQUIRED SUFACE AREA WET POND ELEVATIONS 9.61428 SA/DA = 1.38 From SA/DA Table 1 in Stormwater Design Manual Min Req'd Surface Area = 5,758 SF (at Permanent Pool) Top of Dam Elevation = 271.00 FT Emergency Spillway Elevation = 269.75 FT Temporary Pool Elevation = 267.75 FT Permanent Pool Elevation = 266.50 FT Bottom of Pond Elevation = 261.00 FT Sediment Cleanout, Bottom Elevation = 260.50 FT PERMANENT POOL AREA AND BASIN VOLUME; Area of Permanent Pool = 16,861 SF Elev. 266.50 Area of Bottom of Vegetated Shelf = 15,777 SF Volume of Main Pool = 63,862 CF Volume of Forebay = 0 CF Volume of Main Pool (Exluding Vegetated Shelf) = 55,567 CF Percentage of Forebay to Main Pool = 0.0 % NO PERMANENT POOL SURFACE AREA Is Permenant Pool Surface Area Sufficient (yes/no)? Yes Proposed Surface Area = 16,861 SF Required surface Area = 5,758 SF AVERAGE DEPTH Depth of Pond = 6.00 ft Depth (disc. btwn. bot. of shelf & btm. of pond, excludes sediment; Average Depth = 3.52 ft Based on Equation 3 in Wet Pond MDC Use Average Depth of = 3.50 ft C-3: WET DETENTION BASIN DESIGN CONT'D 1.0 INCH VOLUME ELEVATION Required Temporary Pool Volume = 14,493 CF Permanent Pool Elevaton = 266.50 Temporary Pool Elevation = 267.75 Provided Temporary Pool Volume = 23,272 CF ORIFICE SIZING Q2 D.,s 0.1347 CFS Q5D.Y:= 0.0539 CFS Orifice Size = 2.00 IN Driving Head (Ho) = 0.23 FT Q onnce = 0.066 CFS Drawdown Time = 4.11 DAYS less than 5 days (yes/no) ? Yes greater than 2 days (yes/no) ? Yes ANTIFLOTATION CALCULATIONS Outside Length = 5.00 FT Outside Width = 5.00 FT Inside Length = 4.00 FT Inside Width = 4.00 FT Bottom Thickness = 0.50 FT Top of Riser = 269.75 FT Invert of Riser = 266.50 FT Area = 25.0 SF Volume = 94 CF Weight = 5,850 LBS Factor of Safety = 1.25 WT Req'd of Anti -Flotation Device = 7,313 LBS Volume of Concrete Req'd = 83.5 CF Depth Provided = 2.00 FT Volume Provided = 91.8 CF WT of Anti -Flotation Device Provided = 8,037 LBS Contour Contour Area Incremental Volume Accumulated Volume, S Stage, Z sq ft cu ft cu ft ft 266.50 17,172 0 0 266.5 267.00 18,826 8,995 8,995 267.0 268.00 20,537 19,673 28,668 268.0 269.00 22,303 21,412 50,080 269.0 267.75 20,102 23,272 267.75 (Outside Dim. = 5-ft x 5-ft, Inside Dim. = 4-ft x 4-ft) (Water Displaced - Top of Riser to Bottom of Riser) (Weight Water Displaced) (Unit WT of Concrete = 150 pcf) Submerged Concrete Unit Weight 87.6 pcf (4-ft x 4-ft Box filled 4-ft deep with concrete) OK EXISTING CONDITIONS Project Name: Messer Parcels Project Number: C21020 Date: 11/17/2021 Designed By: ZA Checked By: LL DRAINAGE AREA = PRE DA LAND COVER HSG CN AREA (SF) CN*Area AREA(AC) Onsite Open Space (Fair) A 49 134489 6589961 3.09 Onsite Open Space (Fair) D 84 23682 1989288 0.54 Onsite Woods (Fair) A 36 268692 9672912 6.17 Onsite Woods (Fair) D 1 791 993081 78453321 2.28 Onsite Impervious A 1 981 74561 7306881 0.17 Onsite Impervious D 1 981 01 01 0.00 533627 26828181 12.25 WEIGHTED CURVE NUMBER = 50 POST DEVELOPMENT CONDITIONS Project Name: Messer Parcels Project Number: C21020 Date: 11/17/2021 Designed By: ZA Checked By: ILL DRAINAGE AREA = Post DA1 to Wet Pond 1 LAND COVER HSG CN AREA (SF) CN*Area AREA(AC) Onsite Impervious - Roads/Sidewalk A 98 79000 7742000 1.81 Onsite Impervious - Roads/Sidewalk D 98 0 0 0.00 Onsite Impervious - Lots A 98 76140 7461720 1.75 Onsite Impervious - Lots D 98 14838 1454124 0.34 Open Space (fair) A 49 67982 3331118 1.56 Open Space (fair) D 84 9625 808500 0.22 Open Space Lots (fair) A 49 143010 7007490 3.28 Open Space Lots (fair) D 1 84 27555 2314620 0.63 418150 30119572 9.60 WEIGHTED CURVE NUMBER = 72 DRAINAGE AREA = Post DA1 Undetained LAND COVER HSG CN AREA (SF) CN*Area AREA(AC) Onsite Impervious A 98 0 0 0.00 Onsite Impervious D 98 0 0 0.00 Onsite Open Space (fair) A 49 49921 2446129 1.15 Onsite Open Space (fair) D 84 26789 2250276 0.61 Onsite Woods (fair) A 36 0 0 0.00 Onsite Woods (fair) D 79 38507 3042053 0.88 115217 7738458 2.65 WEIGHTED CURVE NUMBER = 67 Watershed Model Schematic 1 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 1 2r-� �3rr--�� 4 V5 Legend Hvd. Origin Description 1 SCS Runoff PRE DA1 2 SCS Runoff POST DA1 TO WET POND 3 SCS Runoff POST DA1 UNDETAINED 4 Reservoir POST DA1 ROUT 5 Combine POST DA1 Project: X:\Civil\Projects\2021\C21020 - Messer Parcels - Coats\Technical\Calculations ndvhmxtd8�grh1\iLlt-6rAER68ffing\2021. Hydrograph Return Period Recce draflow Hydrographs Extension for Autodesk®Civil 3D® by Autodesk, Inc. v2020 Hyd. Hydrograph Inflow Peak Outflow (cfs) Hydrograph No. type hyd(s) Description (origin) 1-yr 2-yr 3-yr 5-yr 10-yr 25-yr 50-yr 100-yr 1 SCS Runoff ------ 0.144 1.029 ------- ------- 10.44 19.35 ------- 36.69 PRE DA1 2 SCS Runoff ------ 13.21 20.02 ------- ------- 41.43 55.97 ------- 81.06 POST DA1 TO WET POND 3 SCS Runoff ------ 1.953 3.356 ------- ------- 8.043 11.29 ------- 17.11 POST DA1 UNDETAINED 4 Reservoir 2 0.110 0.380 ------- ------- 1.273 5.111 ------- 42.54 POST DA1 ROUT 5 Combine 3,4 2.019 3.445 ------- ------- 8.900 12.59 ------- 59.47 POST DA1 Proj. file: X:\Civil\Projects\2021\C21020 - Messer Parcels - Coats\Technical\Cal t dnesojr,Rblpbdt'gV3W2dwater\Routing\2021 11 Hydrograph Summary Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 0.144 2 778 4,093 ------ ------ ------ PRE DA1 2 SCS Runoff 13.21 2 718 26,790 ------ ------ ------ POST DA1 TO WET POND 3 SCS Runoff 1.953 2 722 5,901 ------ ------ ------ POST DA1 UNDETAINED 4 Reservoir 0.110 2 1442 23,338 2 267.68 22,371 POST DA1 ROUT 5 Combine 2.019 2 722 29,239 3,4 ------ ------ POST DA1 X:\Civi1\Projects\2021\C21020 - Messer Par ellRetGua€ATiedhdi6W`galculations alb'd IdaWthtnh*'AtbRORAuting\2021.11.17 R utinc Hydrograph Report 4 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Hydrograph type = SCS Runoff Storm frequency = 1 yrs Time interval = 2 min Drainage area = 12.250 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 3.02 in Storm duration = 24 hrs Q (cfs) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 00 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor PRE DA1 Hyd. No. 1 -- 1 Year Wednesday, 11 / 17 / 2021 = 0.144 cfs = 778 min = 4,093 cuft = 50 = 0 ft = 14.60 min = Type II = 484 Q (cfs) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Hyd No. 1 Time (min) 5 TR55 Tc Worksheet Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Description A B C Totals Sheet Flow Manning's n-value = 0.400 0.011 0.011 Flow length (ft) = 75.0 0.0 0.0 Two-year 24-hr precip. (in) = 3.65 0.00 0.00 Land slope (%) = 6.05 0.00 0.00 Travel Time (min) = 10.26 + 0.00 + 0.00 = 10.26 Shallow Concentrated Flow Flow length (ft) = 729.00 0.00 0.00 Watercourse slope (%) = 4.90 0.00 0.00 Surface description = Unpaved Paved Paved Average velocity (ft/s) =3.57 0.00 0.00 Travel Time (min) = 3.40 + 0.00 + 0.00 = 3.40 Channel Flow X sectional flow area (sqft) = 4.00 0.00 0.00 Wetted perimeter (ft) = 6.00 0.00 0.00 Channel slope (%) = 1.60 0.00 0.00 Manning's n-value = 0.015 0.015 0.015 Velocity (ft/s) =9.58 0.00 0.00 Flow length (ft) ({0})528.0 0.0 0.0 Travel Time (min) = 0.92 + 0.00 + 0.00 = 0.92 Total Travel Time, Tc.............................................................................. 14.60 min Hydrograph Report I Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 2 POST DA1 TO WET POND Hydrograph type = SCS Runoff Storm frequency = 1 yrs Time interval = 2 min Drainage area = 9.600 ac Basin Slope = 0.0 % Tc method = User Total precip. = 3.02 in Storm duration = 24 hrs Q (cfs) 14.00 12.00 10.00 • 11 4.00 2.00 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 TO WET POND Hyd. No. 2 -- 1 Year Wednesday, 11 / 17 / 2021 = 13.21 cfs = 718 min = 26,790 cuft = 72 = 0 ft = 5.00 min = Type II = 484 Q (cfs) 14.00 12.00 10.00 • 11 4.00 2.00 0.00 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Hyd No. 2 Time (min) Hydrograph Report 7 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Hydrograph type = SCS Runoff Storm frequency = 1 yrs Time interval = 2 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 3.02 in Storm duration = 24 hrs Q (cfs) 2.00 1.00 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 UNDETAINED Hyd. No. 3 -- 1 Year 120 240 360 480 600 720 840 960 Hyd No. 3 Wednesday, 11 / 17 / 2021 = 1.953 cfs = 722 min = 5,901 cuft = 67 = 0 ft = 10.60 min = Type II = 484 Q (cfs) 2.00 1.00 0.00 1080 1200 1320 1440 1560 Time (min) TR55 Tc Worksheet Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Description A B C Totals Sheet Flow Manning's n-value = 0.240 0.011 0.011 Flow length (ft) = 75.0 0.0 0.0 Two-year 24-hr precip. (in) = 3.66 0.00 0.00 Land slope (%) = 8.00 0.00 0.00 Travel Time (min) = 6.09 + 0.00 + 0.00 = 6.09 Shallow Concentrated Flow Flow length (ft) = 582.00 0.00 0.00 Watercourse slope (%) = 2.75 0.00 0.00 Surface description = Unpaved Paved Paved Average velocity (ft/s) =2.68 0.00 0.00 Travel Time (min) = 3.63 + 0.00 + 0.00 = 3.63 Channel Flow X sectional flow area (sqft) = 4.00 0.00 0.00 Wetted perimeter (ft) = 6.00 0.00 0.00 Channel slope (%) = 1.60 0.00 0.00 Manning's n-value = 0.015 0.015 0.015 Velocity (ft/s) =9.58 0.00 0.00 Flow length (ft) Q0))528.0 0.0 0.0 Travel Time (min) = 0.92 + 0.00 + 0.00 = 0.92 Total Travel Time, Tc.............................................................................. 10.60 min Hydrograph Report I Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 4 POST DA1 ROUT Hydrograph type = Reservoir Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - POST DA1 TO WET PONCMax. Elevation Reservoir name = WET POND Max. Storage Storage Indication method used Q (cfs) 14.00 12.00 10.00 .m 4.00 2.00 0.00 0 600 Hyd No. 4 POST DA1 ROUT Hyd. No. 4 -- 1 Year Wednesday, 11 / 17 / 2021 = 0.110 cfs = 1442 min = 23,338 cuft = 267.68 ft = 22,371 cuft Q (cfs) 14.00 12.00 10.00 4.00 2.00 0.00 1200 1800 2400 3000 3600 4200 4800 5400 6000 Time (min) Hyd No. 2 �I Total storage used = 22,371 cuft Pond Report 10 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Pond No. 1 - WET POND Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 266.50 ft Stage / Storage Table Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (cuft) Total storage (cuft) 0.00 266.50 17,172 0 0 0.50 267.00 18,826 8,995 8,995 1.50 268.00 20,537 19,673 28,669 2.50 269.00 22,303 21,412 50,081 3.50 270.00 24,127 23,207 73,287 4.50 271.00 26,007 25,059 98,346 Culvert / Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] [D] Rise (in) = 24.00 2.00 4.00 0.00 Crest Len (ft) = 16.00 30.00 0.00 0.00 Span (in) = 24.00 2.00 8.00 0.00 Crest El. (ft) = 269.25 269.75 0.00 0.00 No. Barrels = 1 1 1 0 Weir Coeff. = 3.33 2.60 3.33 3.33 Invert El. (ft) = 261.00 266.50 267.75 0.00 Weir Type = 1 Broad --- --- Length (ft) = 50.00 0.00 0.00 0.00 Multi -Stage = Yes No No No Slope (%) = 1.00 0.00 0.00 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exfil.(in/hr) = 0.000 (by Wet area) Multi -Stage = n/a Yes Yes No TW Elev. (ft) = 0.00 Stage (ft) 5.00 4.00 3.00 2.00 1.00 0.00 ' 0.0 20.0 Total Q Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s). Stage / Discharge 40.0 60.0 80.0 Elev (ft) 271.50 270.50 269.50 268.50 267.50 266.50 100.0 120.0 140.0 160.0 Discharge (cfs) Hydrograph Report 11 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Hyd. No. 5 POST DA1 Hydrograph type = Combine Peak discharge = 2.019 cfs Storm frequency = 1 yrs Time to peak = 722 min Time interval = 2 min Hyd. volume = 29,239 cuft Inflow hyds. = 3, 4 Contrib. drain. area = 2.650 ac Q (cfs) 3.00 2.00 1.00 0.00 0 600 Hyd No. 5 POST DA1 Hyd. No. 5 -- 1 Year 1200 1800 2400 Hyd No. 3 3000 3600 Hyd No. 4 4200 4800 5400 Q (cfs) 3.00 2.00 1.00 1 0.00 6000 Time (min) Hydrograph Summary Report 12 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 1.029 2 728 10,220 ------ ------ ------ PRE DA1 2 SCS Runoff 20.02 2 718 40,081 ------ ------ ------ POST DA1 TO WET POND 3 SCS Runoff 3.356 2 722 9,339 ------ ------ ------ POST DA1 UNDETAINED 4 Reservoir 0.380 2 1086 35,402 2 267.98 28,311 POST DA1 ROUT 5 Combine 3.445 2 722 44,741 3,4 ------ ------ POST DA1 X:\Civi1\Projects\2021\C21020 - Messer Par ellRetGua€ATiedhi2i6W`galculations alb'd IdaWthtnh*'AtbRORAuting\2021.11.17 R utinc Hydrograph Report 13 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Hydrograph type = SCS Runoff Storm frequency = 2 yrs Time interval = 2 min Drainage area = 12.250 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 3.66 in Storm duration = 24 hrs Q (cfs) 2.00 1.00 1 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor PRE DA1 Hyd. No. 1 -- 2 Year 120 240 360 480 600 720 840 960 Hyd No. 1 Wednesday, 11 / 17 / 2021 = 1.029 cfs = 728 min = 10,220 cuft = 50 = 0 ft = 14.60 min = Type II = 484 Q (cfs) 2.00 1.00 0.00 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 14 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 2 POST DA1 TO WET POND Hydrograph type = SCS Runoff Storm frequency = 2 yrs Time interval = 2 min Drainage area = 9.600 ac Basin Slope = 0.0 % Tc method = User Total precip. = 3.66 in Storm duration = 24 hrs Q (cfs) 21.00 18.00 15.00 12.00 • m . 11 3.00 0.00 0 120 240 Hyd No. 2 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 TO WET POND Hyd. No. 2 -- 2 Year Wednesday, 11 / 17 / 2021 = 20.02 cfs = 718 min = 40,081 cuft = 72 = 0 ft = 5.00 min = Type II = 484 Q (cfs) 21.00 18.00 15.00 12.00 M M IM11111 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 15 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Hydrograph type = SCS Runoff Storm frequency = 2 yrs Time interval = 2 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 3.66 in Storm duration = 24 hrs Q (cfs) 4.00 3.00 2.00 1.00 0.00 ' ' 0 120 240 — Hyd No. 3 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 UNDETAINED Hyd. No. 3 -- 2 Year 360 480 600 720 840 Wednesday, 11 / 17 / 2021 = 3.356 cfs = 722 min = 9,339 cuft = 67 = 0 ft = 10.60 min = Type II = 484 Q (cfs) 4.00 3.00 2.00 1.00 0.00 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 16 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 4 POST DA1 ROUT Hydrograph type = Reservoir Peak discharge Storm frequency = 2 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - POST DA1 TO WET PONCMax. Elevation Reservoir name = WET POND Max. Storage Storage Indication method used Q (cfs) 21.00 18.00 15.00 12.00 • m . 11 3.00 0.00 ' 0 600 Hyd No. 4 POST DA1 ROUT Hyd. No. 4 -- 2 Year Wednesday, 11 / 17 / 2021 = 0.380 cfs = 1086 min = 35,402 cuft = 267.98 ft = 28,311 cuft Q (cfs) 21.00 18.00 15.00 12.00 3.00 0.00 1200 1800 2400 3000 3600 4200 4800 5400 6000 Time (min) Hyd No. 2 I_I_I_I_I_I_1 Total storage used = 28,311 cuft Hydrograph Report 17 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Hyd. No. 5 POST DA1 Hydrograph type = Combine Peak discharge = 3.445 cfs Storm frequency = 2 yrs Time to peak = 722 min Time interval = 2 min Hyd. volume = 44,741 cuft Inflow hyds. = 3, 4 Contrib. drain. area = 2.650 ac Q (cfs) 4.00 3.00 2.00 1.00 0.00 -' 0 POST DA1 Hyd. No. 5 -- 2 Year 600 1200 1800 2400 Hyd No. 5 Hyd No. 3 3000 3600 Hyd No. 4 4200 4800 5400 Q (cfs) 4.00 3.00 2.00 1.00 1 0.00 6000 Time (min) Hydrograph Summary Report 18 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 10.44 2 724 38,551 ------ ------ ------ PRE DA1 2 SCS Runoff 41.43 2 718 83,563 ------ ------ ------ POST DA1 TO WET POND 3 SCS Runoff 8.043 2 722 21,132 ------ ------ ------ POST DA1 UNDETAINED 4 Reservoir 1.273 2 864 78,180 2 268.99 49,922 POST DA1 ROUT 5 Combine 8.900 2 722 99,312 3,4 ------ ------ POST DA1 X:\Civi1\Projects\2021\C21020 - Messer Par ellRetGua€ATiedhdiRk lculations alb'd IdaWthtnh*'Atb2fflRAuting\2021.11.17 R utinc Hydrograph Report 19 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 2 min Drainage area = 12.250 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 5.46 in Storm duration = 24 hrs Q (cfs) 12.00 10.00 4.00 2.00 0.00 ' 0 120 240 Hyd No. 1 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor PRE DA1 Hyd. No. 1 -- 10 Year Wednesday, 11 / 17 / 2021 = 10.44 cfs = 724 min = 38,551 cuft = 50 = 0 ft = 14.60 min = Type II = 484 Q (cfs) 12.00 10.00 4.00 2.00 I I i ■ I I I I I I I. 1 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 20 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 2 POST DA1 TO WET POND Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 2 min Drainage area = 9.600 ac Basin Slope = 0.0 % Tc method = User Total precip. = 5.46 in Storm duration = 24 hrs Q (cfs) 50.00 40.00 M l 1l 20.00 10.00 0.00 0 120 240 Hyd No. 2 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 TO WET POND Hyd. No. 2 -- 10 Year Wednesday, 11 / 17 / 2021 = 41.43 cfs = 718 min = 83,563 cuft = 72 = 0 ft = 5.00 min = Type II = 484 Q (cfs) 50.00 40.00 30.00 20.00 10.00 .— ' ' ' 1 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 21 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 2 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 5.46 in Storm duration = 24 hrs Q (cfs) 10.00 . 11 4.00 2.00 0.00 ' ' 0 120 240 Hyd No. 3 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 UNDETAINED Hyd. No. 3 -- 10 Year Wednesday, 11 / 17 / 2021 = 8.043 cfs = 722 min = 21,132 cuft = 67 = 0 ft = 10.60 min = Type II = 484 Q (cfs) 10.00 . 11 4.00 2.00 J ' ' ' 'I 10.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 22 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 4 POST DA1 ROUT Hydrograph type = Reservoir Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - POST DA1 TO WET PONCMax. Elevation Reservoir name = WET POND Max. Storage Storage Indication method used Q (cfs) 50.00 20.00 10.00 POST DA1 ROUT Hyd. No. 4 -- 10 Year 600 1200 1800 2400 Hyd No. 4 Hyd No. 2 Wednesday, 11 / 17 / 2021 = 1.273 cfs = 864 min = 78,180 cuft = 268.99 ft = 49,922 cuft 3000 3600 4200 4800 5400 III Total storage used = 49,922 cuft Q (cfs) 50.00 40.00 20.00 10.00 1 0.00 6000 Time (min) 23 Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Hyd. No. 5 POST DA1 Hydrograph type = Combine Peak discharge = 8.900 cfs Storm frequency = 10 yrs Time to peak = 722 min Time interval = 2 min Hyd. volume = 99,312 cuft Inflow hyds. = 3, 4 Contrib. drain. area = 2.650 ac POST DA1 Q (cfs) Hyd. No. 5 -- 10 Year Q (cfs) 10.00 10.00 8.00 8.00 6.00 6.00 4.00 4.00 2.00 2.00 0.00 0.00 0 360 720 1080 1440 1800 2160 2520 2880 3240 3600 Time (min) Hyd No. 5 Hyd No. 3 Hyd No. 4 Hydrograph Summary Report 24 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 19.35 2 724 62,146 ------ ------ ------ PRE DA1 2 SCS Runoff 55.97 2 716 113,218 ------ ------ ------ POST DA1 TO WET POND 3 SCS Runoff 11.29 2 720 29,440 ------ ------ ------ POST DA1 UNDETAINED 4 Reservoir 5.111 2 746 107,536 2 269.41 59,708 POST DA1 ROUT 5 Combine 12.59 2 722 136,975 3,4 ------ ------ POST DA1 X:\Civi1\Projects\2021\C21020 - Messer Par ellRetGoa€ATiedhi2iFtlculations alb'd IdaWthtrh*'Atb2fflRAuting\2021.11.17 R utinc Hydrograph Report 25 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Hydrograph type = SCS Runoff Storm frequency = 25 yrs Time interval = 2 min Drainage area = 12.250 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 6.57 in Storm duration = 24 hrs Q (cfs) 21.00 18.00 15.00 12.00 • m . 11 3.00 0.00 0 120 240 Hyd No. 1 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor PRE DA1 Hyd. No. 1 -- 25 Year Wednesday, 11 / 17 / 2021 = 19.35 cfs = 724 min = 62,146 cuft = 50 = 0 ft = 14.60 min = Type II = 484 Q (cfs) 21.00 18.00 15.00 12.00 M M IM11111 i i i . I I I I 1 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 26 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 2 POST DA1 TO WET POND Hydrograph type = SCS Runoff Storm frequency = 25 yrs Time interval = 2 min Drainage area = 9.600 ac Basin Slope = 0.0 % Tc method = User Total precip. = 6.57 in Storm duration = 24 hrs Q (cfs 60.00 50.00 40.00 30.00 20.00 10.00 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 TO WET POND Hyd. No. 2 -- 25 Year Wednesday, 11 / 17 / 2021 = 55.97 cfs = 716 min = 113,218 cuft = 72 = 0 ft = 5.00 min = Type II = 484 Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 0.00 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 Hyd No. 2 Time (min) Hydrograph Report 27 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Hydrograph type = SCS Runoff Storm frequency = 25 yrs Time interval = 2 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 6.57 in Storm duration = 24 hrs Q (cfs) 12.00 10.00 4.00 2.00 0.00 ' 0 120 240 Hyd No. 3 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 UNDETAINED Hyd. No. 3 -- 25 Year Wednesday, 11 / 17 / 2021 = 11.29 cfs = 720 min = 29,440 cuft = 67 = 0 ft = 10.60 min = Type II = 484 Q (cfs) 12.00 10.00 4.00 2.00 ' ' ' 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 28 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 4 POST DA1 ROUT Hydrograph type = Reservoir Peak discharge Storm frequency = 25 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - POST DA1 TO WET PONCMax. Elevation Reservoir name = WET POND Max. Storage Storage Indication method used Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 0.00 ' 0 600 Hyd No. 4 POST DA1 ROUT Hyd. No. 4 -- 25 Year Wednesday, 11 / 17 / 2021 = 5.111 cfs = 746 min = 107,536 cuft = 269.41 ft = 59,708 cuft Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 0.00 1200 1800 2400 3000 3600 4200 4800 5400 6000 Time (min) Hyd No. 2 I_I_I_I_I_I_1 Total storage used = 59,708 cuft 29 Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Hyd. No. 5 POST DA1 Hydrograph type = Combine Peak discharge = 12.59 cfs Storm frequency = 25 yrs Time to peak = 722 min Time interval = 2 min Hyd. volume = 136,975 cuft Inflow hyds. = 3, 4 Contrib. drain. area = 2.650 ac Q (cfs) 14.00 12.00 10.00 RIM 4.00 2.00 0.00 ' ' 0 240 Hyd No. 5 POST DA1 Hyd. No. 5 -- 25 Year 480 720 960 Hyd No. 3 Q (cfs) 14.00 12.00 10.00 4.00 2.00 0.00 1200 1440 1680 1920 2160 Time (min) Hyd No. 4 Hydrograph Summary Report 30 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 36.69 2 724 108,829 ------ ------ ------ PRE DA1 2 SCS Runoff 81.06 2 716 165,469 ------ ------ ------ POST DA1 TO WET POND 3 SCS Runoff 17.11 2 720 44,365 ------ ------ ------ POST DA1 UNDETAINED 4 Reservoir 42.54 2 722 159,546 2 269.97 72,601 POST DA1 ROUT 5 Combine 59.47 2 722 203,911 3,4 ------ ------ POST DA1 X:\Civi1\Projects\2021\C21020 - Messer Par ellRetGoa€ATiedhdMIWAculations alb'd IdaWthtnh*'AtbRORAuting\2021.11.17 R utinc Hydrograph Report 31 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 1 PRE DA1 Hydrograph type = SCS Runoff Storm frequency = 100 yrs Time interval = 2 min Drainage area = 12.250 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 8.42 in Storm duration = 24 hrs Q (cfs) 40.00 30.00 20.00 10.00 0.00 ' ' 0 120 240 — Hyd No. 1 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor PRE DA1 Hyd. No. 1 -- 100 Year Wednesday, 11 / 17 / 2021 = 36.69 cfs = 724 min = 108,829 cuft = 50 = 0 ft = 14.60 min = Type II = 484 Q (cfs) 40.00 30.00 20.00 10.00 i i i I I I I I 1 0.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 32 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 2 POST DA1 TO WET POND Hydrograph type = SCS Runoff Storm frequency = 100 yrs Time interval = 2 min Drainage area = 9.600 ac Basin Slope = 0.0 % TIC method = User Total precip. = 8.42 in Storm duration = 24 hrs Wednesday, 11 / 17 / 2021 Peak discharge = 81.06 cfs Time to peak = 716 min Hyd. volume = 165,469 cuft Curve number = 72 Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 POST DA1 TO WET POND 05 11 • 1 11 ����_ �C�� • 1 1 1 1 1 �1 .1 �:1 .11 1 :�1 •.1 1:1 // 1 ��1 Hydrograph Report 33 Hydraflow Hydrographs Extension for Autodesk® Civil 31D® by Autodesk, Inc. v2020 Hyd. No. 3 POST DA1 UNDETAINED Hydrograph type = SCS Runoff Storm frequency = 100 yrs Time interval = 2 min Drainage area = 2.650 ac Basin Slope = 0.0 % Tc method = TR55 Total precip. = 8.42 in Storm duration = 24 hrs Q (cfs) 18.00 15.00 12.00 .M 3.00 0.00 ' 0 120 240 Hyd No. 3 Peak discharge Time to peak Hyd. volume Curve number Hydraulic length Time of conc. (Tc) Distribution Shape factor POST DA1 UNDETAINED Hyd. No. 3 -- 100 Year Wednesday, 11 / 17 / 2021 = 17.11 cfs = 720 min = 44,365 cuft = 67 = 0 ft = 10.60 min = Type II = 484 Q (cfs) 18.00 15.00 12.00 M 3.00 360 480 600 720 840 960 1080 1200 1320 1440 1560 Time (min) Hydrograph Report 34 Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Hyd. No. 4 POST DA1 ROUT Hydrograph type = Reservoir Peak discharge Storm frequency = 100 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - POST DA1 TO WET PONCMax. Elevation Reservoir name = WET POND Max. Storage Storage Indication method used Q (cfs) 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0 00 0 240 Hyd No. 4 POST DA1 ROUT Hyd. No. 4 -- 100 Year 480 720 Hyd No. 2 Wednesday, 11 / 17 / 2021 = 42.54 cfs = 722 min = 159,546 cuft = 269.97 ft = 72,601 cuft 960 1200 1440 1680 I_I_I_I_I_I_I Total storage used = 72,601 cuft Q (cfs) 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 1920 Time (min) 35 Hydrograph Report Hydraflow Hydrographs Extension for Autodesk® Civil 3D® by Autodesk, Inc. v2020 Wednesday, 11 / 17 / 2021 Hyd. No. 5 POST DA1 Hydrograph type = Combine Peak discharge = 59.47 cfs Storm frequency = 100 yrs Time to peak = 722 min Time interval = 2 min Hyd. volume = 203,911 cuft Inflow hyds. = 3, 4 Contrib. drain. area = 2.650 ac POST DA1 Q (cfs) Hyd. No. 5 -- 100 Year Q (cfs) 60.00 60.00 50.00 50.00 40.00 40.00 30.00 30.00 20.00 20.00 10.00 10.00 0.00 0.00 0 240 480 720 960 1200 1440 1680 1920 Time (min) Hyd No. 5 Hyd No. 3 Hyd No. 4 Q, (cfs) Q2 (cfs) Q10 (cfs) Q25 (cfs) Q100 (cfs) PRE POST PRE POST PRE POST PRE POST PRE POST Total Site (POI 1) *0.1 1 1.03 3.44 10.44 8.90 19.35 12.59 36.69 1 59.47 Notes: *Q1 post development flow pertains only to flows routed through the wet pond and do not include undetained post development flow. Attenuation is provided in a wet pond and meets the overall pre -post requirement for the entire site for the 1-year, 24-hour storm as required. Rainfall Depths based on NOAA Atlas 14, Vol.2 11 = 3.02 in. 12 = 3.66 in. 110 = 5.46 in. 125 = 6.57 in. 1100 = 8.42 in. OPERATION AND MAINTENANCE MANUAL FOR WET POND for MESSER PARCELS Prepared for: T&L Coats, LLC 165 Sommerville Park Road Raleigh, NC 27603 Underfoot Project #: C21020.00 1 ST Submittal: November 17, 2021 Landon Lovelace, PE 1 149 Executive Circle, Suite C Cary, NC 27511 NCBELS # C-3847 1 919.576.9733 underfoot Forward Thinking. Grounded Design. E N G I N E E R I N G www.underfootengineering.com underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 TABLE OF CONTENTS TABLEOF CONTENTS................................................................................................................. 1 1. OPERATION......................................................................................................................... 2 2. MAINTENANCE....................................................................................................................7 3. MAINTENANCE RECORD-KEEPING................................................................................... 11 3.1 Contact Information............................................................................................1 1 3.2 SCM Inspection & Maintenance Log.................................................................12 Forward Thinking. Grounded Design. www.underfootengineering.com underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 1. OPERATIONS A Wet Pond is designed to have a permanent pool of water. It detains and treats stormwater flows by increasing the depth of water on top of a pool of water and then slowly releasing the stored water over time. A concrete structure called a riser is present and has various holes and/or weirs cut into the sides of the structure to release the various flows over time. Below are various views of this stormwater control measure. Note that your pond may vary from these figures. Figure 1: Wet Pond Example: Plan View i FOUNTAIN (OPTIONAL FEATUREt VERIFY EROSION AND RE -SUSPENSION I OF SEDIMENT WILL NOT OCCUR: DO NOT PLACE NEAR OUTLET J J MAIN POOL SURFACE AREA AND VOLUME SIZED USING EITHER jai HYRDAL .IC RETENTION TAIE h1ETHOD. or ID) THE SADA ANO AVERAGE DEPTH METHOD VEGETATED SHELF PAINIA0.161 WIDTH 6 FT MAXIMUM SLOPE 6 H :1 V VEGETATED SIDE SLOPES — RECOM6IENDEO SLOPE 3 H 1 V PLANTED WITH NON -CLUMPING TURF GRASS TREES AND WOODY SHELVES NOT ALLOWED /�/'. OUTLET STRUCTURE —. PLACE INLETS AND OUTLETS TO AVOID SHORTCIRCUTINGAND DESIGN FOR EROSION PROTECTION EMERGENCY SPILLWAY - PROVIDED FOR MAJOR STORMS AND DESIGNED FOR EROSION PROTECTION TRANSITION FRO6I FOREBAY TO -J MAN POOL SHALL FLOW AT A NON-EROSNE VELOCITY !1 SCAT MWINTENANCE AND ACCESS EASEMENT \ \ \ FOREBAY 15 TO 20 PERCENT \ OF MAIN POOL VOLUME INLET STRUCTURE PLACE INLETS AND OUTLETS TO AVOID SHORT-CIRCUTLNG AND DESIGN FOR EROSION PROTECTION Forward Thinking. Grounded Design. www.underfootengineering.com a underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 Figure 2: Wet Pond Example: Cross -Section View 1 FOREBAY (a)15 TO 20 PERCENT OF MAIN POOL VOLUME (b) ENTRANCE SHALL BE DEEPER THAN EXIT (c) WATER FLOWNG OVER FOREBAY DATA SHALL FLOW AT NON-EROSfVE VELOCITY (0) IF DEPTH c 30 INCHES. CLEAN OUT FOREBAY TEMPORARY POOL DESIGN TO DRAW DOWN BETWEEN TWO AND FIVE DAYS - AWN POOL SURFACE AREA AND VOLUME SURFACE AREA ANDVOLLAIE SIZED USING EITHER (a) HYDRAULIC RETENTION T11ME METHOD, OR (b) THE SA'DA AND AVERAGE DEPTH METHOD EMBANKMENT MIN WIDTH 10 FT FOR EMERGENCY SPILLWAY MAINTENANCE �O A�� ----- --- MIN: Q TEI - - --Y POOL ---- - ------- ------MAIN POOL--------- -- - -- - -- -- > -///// // VEGETATED SIDE SLOPES SEDIMENT STORAGE MAIN POOL DEPTH VEGETATED SHELF RECOMMENDED SLOPE. 3 H : 1 V MINIMUM SEDIMENT AVG. DEPTH: I TO 8' MINIMUM WIDTH: 6 FT PLANTED WITH NON CLUMPING STORAGE DEPTH OF 6- 'OPTICN TO EXCLUDE MAXIMUM SLOPE 6 H 1 V TURF GRASS TREES AND SUBMERGED PORTION VEGETATION: MINIMUM OF 3 WOODY SHELVES NOT OF VEG SHELF FROM DIVERSE SPECIES OF ALLOWED CALCULATIONS HERBACEOUS. NATIVE SPECIES MIN.50 PLANTS PER 200 SF OF SHELF Forward Thinking. Grounded Design. www.underfootengineering.com 3 underfoot ENGINEERING OUTLET STRUCTURE MUST BE SIZED TO (a) DRAWDOWN TEMPORARY POOL N TWO TO FIVE DAYS (b) DISCHARGE RUNOFF FROM M-YR. 24-HR STORM TO MINIMIZE HYDROLOGIC IMPACTS TEMPORARY POOL MAN POOL --------------- 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 Figure 3: Wet Pond Example: Cross -Section View 2 VEGETATED SHELF MINIMUM WIDTH: 6 FT MAXIMUM SLOPE: 6 M T V VEGETATED SIDE SLOPES RECOMMENDED SLOPE: 3 H : T V TRASH RACK FRONT AND BACK EMBANKMENT SLOPE REOUIRED REQUIRED TO BE VEGETATED r Lei EMBANKMENT ELF Fes— / 0 FT FOR / MINIMUM WIDTH X � MAINTENANCE tACCESS PROPOSED GRADE OUTLET PIPE ,-- EXISTING GRADE DEWATERNG METHOD WET PONDS SHALL HAVE A METHOD TO DRAW DOWN STANDING WATER TO FACILITATE MAINTENANCE AND NSPECTION MN. V SEDIMENT (E.G. SKIMMER OR PUMP) STORAGE Figure 4: Wet Pond Example: Outlet Structure TRASH RACK (REQUIRED) WEIR IOR OTHER METHODI TO ESTABLISH TEMPORARY POOL RISER CREST ORIFICE OUTLET TO ESTABLISH NORMALPOOL MUST DRAW DOWN TEMPORARY POOL IN TWO TO FIVE DAYS DEWATERING METHOD WET PONDS SHALL HAVE METHOD TO DRAW DOWN STANDING WATER TO FACILITATE MAINTENANCE AND INSPECTION (E.G., SKIMMER OR PUMP) ANTI -FLOTATION SLAB T - — - - - - - - - OUTLET PIPE ANTI -SEEP MEASURES ARE RECOMMENDED Forward Thinking. Grounded Design. www.underfootengineering.com 4 �--Om underfoot `w ENGINEERING Figure 5: Plan view of Messer Parcels Wet Pond ' 01 �;'••iiiiiiii• ••• j• ' , .•�••••.••••••••••� mill 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 Forward Thinking. Grounded Design. www.underfootengineering.com 5 underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 Figure 6: Profile View of Arringdon Lot 3 Wet Pond SCM # 1 -WET POND CROSS SECTION Note: When the pond bottom is below the invert of the pond drain, pump dewatering may be required to drain the pond for maintenance. An experienced contractor shall use a pump and silt -bag to dewater the pond. Forward Thinking. Grounded Design. www.underfootengineering.com underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 2. MAINTENANCE Important maintenance procedures for this Stormwater Control Measure (SCM) include: • It is recommended that this facility be inspected/monitored monthly and after any rain event that produces at least 1" of rainfall during a 24-hour period. • No portion of the SCM should be fertilized after the first initial fertilization that is required to establish the plants on the vegetated shelf. • Stable groundcover should be maintained in the drainage area to reduce the sediment load to the SCM. • If the SCM must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain should be minimized as much as possible. • The dedicated access easement needs to be maintained so that a clear pathway to and around the SCM is present. No obstructions should be present within this pathway. The SCM shall be inspected annually. If functional issues arise during the year, a qualified SCM inspector should be contacted to provide a supplemental assessment and recommendation for remediation of any functional deficiencies. Forward Thinking. Grounded Design. www.underfootengineering.com 7 underfoot ENGINEERING 1149 Executive Circle - Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 The entire BMP Trash/debris is present. Remove the trash/debns. The perimeter of the wet pond Areas of bare soil and/or erosive gullies have formed Vegetation is too short or too long. The inlet device: pipe or swale The pipe is clogged. The pipe is cracked or otherwise damaged. Erosion is occurring in the swale. The forebay Sediment has accumulated to a depth qreater than the oriqinal design depth for sediment storage. Erosion has occurred Weeds are present Regrade the soil if necessary to remove the qully. and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Maintain vegetation at a height of approximately six inches. Unclog the pipe. Dispose of the sediment off -site. Replace the pipe. Regrade the swale if necessary to smooth it over and provide erosion control devices such as reinforced turf matting or riprap to avoid future problems with erosion. Search for the source of the sediment and remedy the problem if possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Remove the weeds. preferably by hand. If pesticide is used. wipe it on the plants rather than spraying. Forward Thinking. Grounded Design. www.underfootengineering.com _1149 Executive Circle -Suite C, Cary, NC 27511 underfoot _ 919.576.9733 1 NCBELS C-3847 ENGINEERING The vegetated shelf Best professional practices Prune according to best show that pruning is needed to professional practices maintain optimal plant health. Plants are dead, diseased or Determine the source of the dying. problem: soils. hydrology. disease. etc. Remedy the problem and replace plants. Provide a one-time fertilizer application to establish the ground cover if a soil test indicates it is necessary. Weeds are present. Remove the weeds. preferably by hand. If pesticide is used, wipe it on the plants rather than spraying. The main treatment area Sediment has accumulated to a Search for the source of the depth greater than the original sediment and remedy the design sediment storage depth. problem if possible. Remove the sediment and dispose of it in a location where it will not cause impacts to streams or the BMP. Algal growth covers over 50% Consult a professional to of the area. remove and control the algal growth. Cattails. phragmites or other Remove the plants by wiping invasive plants cover 50% of them with pesticide (do not the basin surface. spray). The embankment Shrubs have started to grow on Remove shrubs immediately. the embankment. Evidence of muskrat or beaver Use traps to remove muskrats activity is present. and consult a professional to remove beavers. A tree has started to grow on Consult a dam safety specialist the embankment. to remove the tree. An annual inspection by an Make all needed repairs. appropriate professional shows that the embankment needs repair. Forward Thinking. Grounded Design. www.underfootengineering.com _1149 Executive Circle -Suite C, Cary, NC 27511 underfoot _ 919.576.9733 1 NCBELS C-3847 ENGINEERING The outlet device / The Clogging has occurred. Clean out the outlet device. receiving water Dispose of the sediment off - site. Floating wetland island (if applicable) The outlet device is damaged Weeds or volunteer trees are growing on the mat. The anchor cable is damaged disconnected or missing. Repair or replace the outlet device. Remove the weeds or trees. Restore the anchor cable to its design state. Forward Thinking. Grounded Design. www.underfootengineering.com 1149 Executive Circle -Suite C, Cary, NC 27511 underfoot _ 919.576.9733 1 NCBELS C-3847 ENGINEERING 3. MAINTENANCE RECORD -KEEPING 3.1 Contact Information All inspection and maintenance record -keeping shall be maintained by the owner (or the owner's representative). An inspection log for the Stormwater Control Measure is attached. For this facility, the owner's representative contact information is: Name: Company: Mailing Address: Phone: E-mail: Forward Thinking. Grounded Design. www.underfootengineering.com 1 1 underfoot ENGINEERING 3.2 SCM Inspection & Maintenance Log 1149 Executive Circle -Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 System Location Date Inspection (quarterly, yearly, post- storm?) Presence of Debris/Trash (yes/no) Condition of Grass Sod (eroded, bare spots, healthy?) Standing Water (yes/no) Control Structure (clean or sediment) Maintenance Performed Maintenance Personnel Comments Forward Thinking. Grounded Design. www.underfootengineering.com WIW underfoot 1i ENGINEERING 1149 Executive Circle -Suite C, Cary, NC 27511 919.576.9733 1 NCBELS C-3847 S sy tem Location Date Inspection (quarterly, y early, post- storm.) Presence of Debris/Trash (yes/no) Condition of Grass Sod (eroded, bare spots, healthy?) Standing Water (yes/no) Control Structure (clean or sediment) Maintenance Performed Maintenance Personnel Comments Forward Thinking. Grounded Design. www.underfootengineering.com APPENDIX C: CONVEYANCE mftlpp-44� iw underfoot ENGINEERING CALCULATIONS PIPE SIZING GUTTER SPREAD HGL ANALYSIS SWALE CALLS DISSIPATORS 1149 Executive Circle, Suite C-1 Cary, NC 27511 NCBELS # C-3847 1 919.576.9733 Forward Thinking. Grounded Design. www.underfootengineering.com Upstream Node Downstream Node Upstream Inlet C Upstream Inlet Area (acres) Upstream Intensity* (in/h) Pipe Diameter (in) Material Pipe Length (ft) Capacity (Full Flow) (ft'/s) Total Pipe Flow (ft'/s) Total System Flow (ft'/s) Slope (ft/ft) Invert (Upstream) (ft) Invert (Downstream) (ft) Inlet* Elevation (Rim) (ft) Elevation (Invert) (ft) Structure Height (ft) Inlet Type Bypass Target Flow (Total Intercepted) (ft'/s) Flow (Total Bypassed) (ft'/s) Gutter Depth (in) Gutter Spread (ft) STM 204 STM 203 0.58 0.301 7.22 15 HDPE 200 11.17 1.26 1.17 0.026 281.5 276.4 STM 204 286.6 281.5 5.1 Drop - Grate - NCDOT 840.15 STM 203 0.7 0.01 1.1 2.7 STM 203 STM 202 0.58 0.26 7.092 15 HDPE 150 10.54 1.07 2.09 0.023 276.3 272.9 STM 203 280.65 276.3 4.3 Drop - Grate - NCDOT 840.15 STM 202 0.56 0.05 1.4 4 STM 202 STM 201 0.58 0.19 7.008 15 HDPE 192 10.71 0.77 2.9 0.023 272.8 268.3 STM 202 277 272.8 4.2 Drop - Grate - NCDOT 840.15 STM 201 0.47 0.03 1.3 3.6 STM 201 STM 200 1 0.58 0.28 6.91 15 HDPE 127.4 15.81 1 1.12 3.89 0.051 1 267.5 261 1 STM 201 271.57 267.5 4.1 1 Drop - Grate - NCDOT 840.15 0.62 0.06 1.5 4.1 STM 145 STM 144 0.4 0.146 7.22 15 HDPE 200 13.28 0.42 0.41 0.036 285.5 278.3 STM 145 289.74 285.5 4.2 Drop - Grate - NCDOT 840.15 STM 144 0.24 1 0 1 2.2 STM 144 STM 143 0.4 0.298 7.066 15 HDPE 200 13.82 0.84 1.18 0.039 278.2 270.4 STM 144 282.5 278.2 4.3 Drop - Grate - NCDOT 840.15 STM 143 0.47 0.01 1.2 3 STM 143 STM 142 0.4 0.614 6.957 15 HDPE 102 4.1 1.71 2.97 0.003 270.3 269.95 STM 143 273.66 270.3 3.4 Drop - Grate - NCDOT 840.15 1 0 2.3 7.4 STM 142 STM 141 0.6 0.343 6.851 15 Class III RCP 26 6.94 1.41 4.74 0.012 269.85 269.55 STM 142 273.53 269.85 3.7 Combo - NCDOT 840.03 0.94 0 3.4 3.7 STM 141 STM 140 0.83 0.215 6.835 18 Class III RCP 55.2 6.48 1.22 5.95 0.004 269.3 269.09 STM 141 273.53 269.3 4.2 Combo - NCDOT 840.03 0.78 0 3.2 3 STM 140 STM 101 0.84 0.045 6.785 18 Class III RCP 105.4 7.16 0.26 6.17 0.005 268.99 268.5 STM 140 273.62 269 4.6 Combo - NCDOT 840.03 STM 141 0.15 0 0.9 1.8 STM 134 STM 133 0.66 0.189 7.22 15 Class III RCP 29.5 9.21 0.9 0.81 0.02 285.7 285.1 STM 134 289 285.7 3.3 Combo - NCDOT 840.03 STM 132 0.49 0.01 1.2 3 STM 133 STM 131 0.66 0.146 7.196 15 Class III RCP 200.2 13.62 0.69 1.47 0.044 285 276.1 STM 133 288.24 285 3.2 Combo - NCDOT 840.03 STM 131 0.39 0 1.1 2.6 STM 132 STM 131 0.66 0.355 7.22 15 Class III RCP 29.4 7.98 1.69 1.39 0.015 276.55 276.1 STM 132 279.88 276.55 3.3 Combo - NCDOT 840.03 STM 142 0.85 0.11 1.5 4.3 STM 131 STM 130 0.66 0.329 7.092 15 Class III RCP 75.9 14.36 1.54 4.07 0.049 276 272.25 STM 131 279.26 276 3.3 Combo - NCDOT 840.03 STM 130 0.79 0.09 1.5 4.1 STM 130 STM 102 0.6 0.094 7.064 18 Class III RCP 106.9 17.89 0.4 4.71 0.029 272 268.9 STM 130 275.51 272 3.5 Combo - NCDOT 840.03 STM 102 0.31 0 1.1 2.6 STM 121 STM 120 0.48 0.134 7.22 15 HDPE 225.1 14.3 0.46 0.46 0.042 281.5 272.1 STM 121 285.68 281.5 4.2 Drop - Grate - NCDOT 840.15 STM 120 0.26 0 1 2.1 STM 120 STM 103 0.48 0.356 7.061 15 Class III RCP 30.7 15.2 1.21 1.46 0.055 272 270.3 STM 120 276.66 272 4.7 Drop - Grate - NCDOT 840.15 0.64 0.05 1.4 3.8 STM 116 STM 115 0.3 0.15 7.22 15 Class III RCP 32.4 14.58 0.32 0.33 0.051 292.15 290.5 STM 116 296.15 292.15 4 Drop- Grate - NCDOT 840.15 0.18 0 1.2 2.8 STM 115 STM 112 0.95 0.025 7.195 15 Class III RCP 123.6 12.33 0.17 0.5 0.036 290.4 285.9 STM 115 294.54 290.4 4.1 Combo - NCDOT 840.03 0.1 0 0.7 1.4 STM 114 STM 112 0.4 0.826 7.22 15 Class III RCP 57.7 6.59 2.39 2.41 0.01 286.5 285.9 STM 114 287.34 286.5 0.8 Drop- Grate - NCDOT 840.15 1.33 0 2.6 8.8 STM 113 STM 112 0.66 0.26 7.22 15 Class III RCP 26.4 7.95 1.24 1.09 0.015 286.3 285.9 STM 113 28 ..64 286.3 3.3 Combo - NCDOT 840.03 STM 109 0.66 0.03 1.3 3.3 STM 112 STM 111 0.84 0.086 7.1 15 Class III RCP 31 17.21 0.51 4.43 0.071 285.8 283.6 STM 112 291.48 285.8 5.7 Combo - NCDOT 840.03 STM 111 0.29 0 1 2 STM 111 STM 110 0.84 0.038 7.09 15 Class III RCP 43.5 8.19 0.22 4.66 0.016 283.5 282.8 STM 111 288 283.5 4.5 Combo - NCDOT 840.03 STM 108 0.13 0 0.7 1.5 STM 110 STM 108 0.55 0.648 7.066 15 Class III RCP 59.5 8.37 2.52 7.19 0.017 282.7 281.7 STM 110 286.04 282.7 3.3 Combo - NCDOT 840.03 1.44 0 3.8 5.6 STM 109 STM 108 0.66 0.168 7.22 15 Class III RCP 32.9 6.16 0.8 0.82 0.009 281.8 281.5 STM 109 285.05 281.8 3.3 Combo - NCDOT 840.03 STM 107 0.45 0.02 1.3 3.5 STM 108 STM 106 0.66 0.274 7.037 15 Class III RCP 230.1 10.86 1.27 8.96 0.028 281.4 274.9 STM 108 285 281.4 3.6 Combo - NCDOT 840.03 STM 106 0.65 0.08 1.5 4.3 STM 107 STM 106 0.6 0.422 7.22 15 Class III RCP 26 6.94 1.83 1.42 0.012 275.2 274.9 STM 107 278.49 275.2 3.3 Combo - NCDOT 840.03 STM 104 0.87 0.17 1.7 5 STM 106 STM 105 0.6 0.277 6.95 18 Class III RCP 102.7 16.06 1.16 11.32 0.023 274.65 272.25 STM 106 278.49 274.65 3.8 Combo - NCDOT 840.03 STM 105 0.67 0.08 1.5 4.3 STM 105 STM 103 0.66 0.132 6.91 18 Class III RCP 50.5 18.7 0.6 13.35 0.032 272 270.4 STM 105 275.6 272 3.6 Combo - NCDOT 840.03 STM 103 0.42 0.01 1.2 3.2 STM 104 STM 105 0.66 0.267 7.22 15 Class III RCP 26.2 9.36 1.27 1.35 0.021 272.75 272.2 STM 104 276 272.75 3.3 Combo - NCDOT 840.03 STM 101 0.77 0.12 1.6 4.6 STM 103 STM 102 0.67 0.052 6.894 24 Class III RCP 71.6 31.63 0.24 15.11 0.02 269.9 268.5 STM 103 274.09 269.9 4.2 Combo - NCDOT 840.03 STM 102 0.15 0 0.8 1.7 STM 102 STM 101 0.55 0.279 6.867 24 Class III RCP 50.9 22.41 1.05 20.67 0.01 268.4 267.9 STM 102 272.56 2611.4 4.2 Combo - NCDOT 840.03 0.61 0.01 1.1 2.7 STM 101 STM 100 0.68 0.399 6.698 24 Class III RCP 67.8 58.27 1.82 28.55 0.066 265.5 261 STM 101 271.9 265.5 6.4 Combo - NCDOT 840.03 1.21 0 3.6 4.8 Notes: Entire length of pipe is o-ring gasketed w/ joints double -wrapped in non -woven filter fabric. Upstream structure shall be constructed with watertight gaskets, and pipes fit into structure with watertight gaskets. Gutter spread computations shown in this table are based on the 4in/hr storm. Gutter spread bypass targets are only shown for on -grade structures which bypass to on -site targets. Structures in a sag do not have bypass targets. Pipe sizing is based on 10-year storm intensities showin herein. Intensities shown are based on a time of concentration (Tc) of 5 minutes. Total System Flow is calculated based on flow intercepted at structure. Bypassed flow captured from upstream structures is included and pipe sizes are calculated accordingly. Rim Elevations: NCDOT 840.03 rim elev is @ flow line, middle of frame. Back of curb elev is rim elev +0.50' NCDOT 840.15 rim elev is @ top of grate ctf 274. 27, 273. 27 272. 27. 271. 27 270. 27 269. 26 268. 26 267. 26 266. 26 265. 26 264. 26 263. 26 262. 26 261. 26, Profile Report Profile: STM 103 TO STM 100 STM 103 TO STM 100 - Coats - 10yr Label: STM 103 -5 0 5 1015 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 9510010511011,9 2012513013514014,9 5015516C16,9 70179 80185190195 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 104 TO STM 105 Label: sST10 104 TO STM 105 - Coats - 1 Oyr Type: Catch Basin I b: 238 276.000000000001 275.900000000001 275.800000000001 275.700000000001 275.600000000001 275.500000000001 275.400000000001 275.300000000001 275.200000000001 275.100000000001 275.000000000001 274.900000000001 274.800000000001 274.700000000001 2 �00000000001 ALW00000000001 0000000001 274.300000000001 2C:200000000001 O 274.1 -1--+ 274 Cu 273.9 > 273.8 273.7 _ 273.6 W 273.5 273.4 273.3 273.2 273.1 273 272.9 272.8 272.7 272.6 272.5 272.4 272.3 272.2 272.1 272 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 212223242526272829 Station (ft) n StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 106 TO STM 103 STM 106 To STM 103 - Coats - 1Oyr Label: STM 106 Type: Catch Basin 278.6 ID: 179 278.4 278.2 278 277.8 277.E 277.4 277.2 277 276.8 276.E 276.4 276.2 276 275.8 275.6 r� 275.4 }� 275.2 275 P74.8 274.6 p . n _dun STM, C C 0 274.4 274.2 }� 274 273.8 > 273.6 273.4 273.2 273 W 272.8 272.6 272.4 272.2 272 271.8 271.6 271.4 271.2 271 270.8 270.6 270.4 270.2 270 269.8 103 asin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 107 TO STM 106 Label: sSTIM7 107 TO STM 106 - Coats -Ljk@f TM 106 Type: Catch Basin Type: Catch Basin 278.500000000001 278.400000000001 278.300000000001 278.200000000001 278.100000000001 278.000000000001 277.900000000001 277.800000000001 277.700000000001 277.600000000001 277.500000000001 277.400000000001 277.300000000001 277.200000000001 002M100000000001 =7.000000000001 '*- f.900000000001 F6.800000000001 .700000000001 276.6 +� 276.5 cc 276.4 276.3 276.2 276.1 W 276 275.9 275.8 275.7 275.6 275.5 275.4 275.3 275.2 275.1 275 274.9 274.8 274.7 274.6 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 109 TO STM 108 Label: S-&-FM 109 TO STM 108 - Coats -A0&VI:rSTM 108 Type: Catch Basin Type: Catch Basin 2$5.100000000001 117). 940 i ^. -1 0 n 285.000000000001 284.900000000001 284.800000000001 284.700000000001 284.600000000001 284.500000000001 284.400000000001 284.300000000001 284.200000000001 284.100000000001 284.000000000001 283.900000000001 �jic�:IlIIIIII' 3.700000000001 �3.600000000001 283.500000000001 283.4 Q 283.3 a--+ 283.2 m 283.1 � v\ 283 /� 282.9 282.8 W 282.7 282.6 282.5 282.4 282.3 282.2 282.1 282 281.9 281.8 281.7 281.6 281.5 281.4 281.3 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122232425262728293031 32 33 34 35 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w C21020 StormCAD Model.stsw 11 /15/2021 Profile Report Profile: STM 110 TO STM 106 STM 110 TO STM 106 Label: STM 110 Type: Catch Basin 286.5 I p -Ar 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 Coats - 10yr Label: P24 Label: STM 108 Type: Conduit 106 Basin -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Station (ft) Bentley Systems, Inc. Haestad Methods Solution Center 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 w Profile Report Profile: STM 113 TO STM 112 STM 113 TO STM 112 - Coats - 10yr Labe : STM 112 Type: Catch Basin -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 r� 4-0 O -r- _(D w 291.6 291.4 291.2 291 290.8 290.6 290.4 290.2 290 289.8 289.6 289.4 289.2 289 288.8 288.6 288.4 288.2 288 287.8 287.6 287.4 287.2 287 286.8 286.6 286.4 286.2 286 285.8 285.6 285.4 285.2 285 284.8 284.6 284.4 284.2 284 283.8 283.6 283.4 283.2 283 282.8 282.6 Profile Report Profile: STM 114 TO STM 110 STM 114 TO STM 110- Coats - 10yr Label: STM 112 Type: Catch Basin 110 Basin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 116 TO STM 112 STM 116 TO STM 112 - Coats - 10yr Label: STM 116 Type: Catch Basin 296. 199999999999 I D : 334 295.999999999999 295.799999999999 295.599999999999 Abel: STM 115 295.399999999999 295.199999999999 Labe . e: Catch Basin 294.999999999999 294.799999999999 Type: Con 333 294.E 294.4 D: 335 294.2 294 293.8 293.6 293.4 293.2 293 292.8 292.6 292.4 n a e1: STI\ �••~+ 292.2 292 Type: Catch 291.8 291 I D: 18' .6 291.4 O 291.2 291 }+ 290. 290.6 290.4 /� 290.2 290 289.8 289. w 289.4 289.2 289 288.8 288.6 zzz 288.4 288.2 288 287.8 287.6 287.4 287.2 287 286.8 286.6 286.4 286.2 286 285.8 1 112 Basin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 000-1 O W 287.0 28TYP 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 Profile Report Profile: STM 121 TO STM 103 STM 121 TO STM 103 - Coats - 10yr Label: P20 Type: Conduit ID: 133 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Station (ft) 103 Basin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 �1 �%-100 0 4--+ co _W W Label: STM 131 TYPE 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 Profile Report Profile: STM 131 TO STM 100 STM 131 TO STM 100 - Coats - 1Oyr Label: P14 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 132 TO STM 131 Label: s�TIN 132 TO STM 131 - Coats - 10yr Type: Catch Basin in. 179 279.900000000001 279.800000000001 279.700000000001 279.600000000001 279.500000000001 279.400000000001 279.300000000001 279.200000000001 279.100000000001 279.000000000001 278.900000000001 278.800000000001 278.700000000001 278.600000000001 =M0000000001 4R4.400000000001 "!rM'300000000001 2=.200000000001 278.1 O _ 278 +� 277.9 277.8 > 277.7 277.6 277.5 W 277.4 277.3 277.2 277.1 277 276.9 276.8 276.7 276.6 276.5 276.4 276.3 276.2 276.1 276 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 30 3132 Station (ft) �1 sin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 291 Lcl�91 Ty pe:5 C 281 D 288. 288 287.5 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 Profile Report Profile: STM 133 TO STM 131 STM 133 TO 91hAil3dB�-Coats - 10yr Type: Conduit -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100 091015120 29 30 39 40 49 50 55160 65170 79 80 89 90 9a0(205 Station (ft) 1 131 Basin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 134 TO STM 133 Label: S.P,TN 134 TO STM 133 - Coats - 10yr Type: Catch Basin 289.100000000001 289.000000000001 288.900000000001 288.800000000001 288.700000000001 288.600000000001 288.500000000001 288.400000000001 288.300000000001 288.200000000001 288.100000000001 288.000000000001 287.900000000001 287.800000000001 ,?AZ.700000000001 4OM600000000001 V00000000001 400000000001 ..300000000001 200000000001 287.1 4-0 287 cu 286.9 > 286.8 ^' 286.7 VJ 286.6 W 286.5 286.4 286.3 286.2 286.1 286 285.9 285.8 285.7 285.6 285.5 285.4 285.3 285.2 285.1 285 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122232425262728293031 32 Station (ft) 2 sin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w 274 T 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 Profile Report Profile: STM 142 TO STM 100 STM 142 TO STM 100 - Coats - 1Oyr Label: STM 142 Label: STM 141 Label: STM 140 ne- Catch ID: sin T 163 ID: 16 ��•� y ID: 161vGJ La el: STIA 101 La el: PO Type. Catch Basin Type: ID: Conduit 147 La Type: el: P07 Conduit Label: PO T Con uit Label: P05 Type: ID Conduit 15 TV36woutil 154 11 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 w C21020 StormCAD Model.stsw 11 /15/2021 Profile Report Profile: STM 144 TO STM 142 STM 144 TO STM 142 Label: STM 144 T$y.pe: Catch Basin 283 I D : 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 Label: P10 Type: Conduit ID: 135 - Coats - 10yr 1 142 Basin 3 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 Station (ft) Bentley Systems, Inc. Haestad Methods Solution Center 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 C 0 -1-_jcc a� Ini Profile Report Profile: STM 145 TO STM 144 TM 145 TO SlMrM4 - Coats - 1Oyr Label: STM 45 Type: Conduit Type: Catch Basin ID: 125 - 29 D 289.5 289 288.5 288 287.5 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 'M 144 :h Basin 3%5 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 9510q 05110115120125130135i 40145i 50155i 6016517017518018519019g0(P05 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 202 TO STM 200 STM 202 TO STM 200 Label: STM 202 Type: Catch Basin Label: P02 ID: 156 Type: Conduit 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 - Coats - 10yr TM 200 Dutfall 153 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w Profile Report Profile: STM 204 TO STM 202 STM 204 TO STM 202 - Coats - 10yr Label: STM 204 Type: Catch Basin 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 nhai- Pnd 202 Basin -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 ctf 274. 27, 273. 27 272. 27. 271. 27 270. 27 269. 26 268. 26 267. 26 266. 26 265. 26 264. 26 263. 26 262. 26 261. 26, Profile Report Profile: STM 103 TO STM 100 STM 103 TO STM 100 - Coats - 25yr Label: STM 103 -5 0 5 1015 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 9510010511011,9 2012513013514014,9 5015516C16,9 70179 80185190195 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 104 TO STM 105 Label: sST10 104 TO STM 105 - Coats - 25yr Type: Catch Basin I b: 238 276.000000000001 275.900000000001 275.800000000001 275.700000000001 275.600000000001 275.500000000001 275.400000000001 275.300000000001 275.200000000001 275.100000000001 275.000000000001 274.900000000001 274.800000000001 274.700000000001 2 �00000000001 ALW00000000001 0000000001 274.300000000001 2C:200000000001 O 274.1 -1--+ 274 Cu 273.9 > 273.8 273.7 _ 273.6 W 273.5 273.4 273.3 273.2 273.1 273 272.9 272.8 272.7 272.6 272.5 272.4 272.3 272.2 272.1 272 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 212223242526272829 Station (ft) n StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 106 TO STM 103 STM 106 TO STM 103 - Coats - 25yr Label: STM 106 Type: Catch Basin 278.E III. 17g 278.4 278.2 278 277.8 277.6 277.4 277.2 277 276.8 276.6 276.4 276.2 276 275.8 275.6 275.4 275.2 275 274.8 274.6 274.4 2742 274 273.8 273.6 273.4 273.2 273 272.8 272.6 272.4 272.2 272 271.8 271.6 271.4 2712 271 270.8 270.6 270.4 270.2 270 269.8 103 lasin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 107 TO STM 106 Label: sSTIM7 107 TO STM 106 - Coats -1-25fSTM 106 Type: Catch Basin Type: Catch Basin 278.500000000001 278.400000000001 278.300000000001 278.200000000001 278.100000000001 278.000000000001 277.900000000001 277.800000000001 277.700000000001 277.600000000001 277.500000000001 277.400000000001 277.300000000001 277.200000000001 002M100000000001 =7.000000000001 '*- f.900000000001 F6.800000000001 .700000000001 276.6 +� 276.5 cc 276.4 276.3 276.2 276.1 W 276 275.9 275.8 275.7 275.6 275.5 275.4 275.3 275.2 275.1 275 274.9 274.8 274.7 274.6 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 109 TO STM 108 Label: S-&-FM 109 TO STM 108 - Coats - 490,Yr STM 108 Type: Catch Basin Type: Catch Basin 2$5.100000000001 117). 940 i ^. -1 0 n 285.000000000001 284.900000000001 284.800000000001 284.700000000001 284.600000000001 284.500000000001 284.400000000001 284.300000000001 284.200000000001 284.100000000001 284.000000000001 283.900000000001 �jic�:IlIIIIII' 3.700000000001 �3.600000000001 283.500000000001 283.4 Q 283.3 a--+ 283.2 m 283.1 � v\ 283 /� 282.9 282.8 W 282.7 282.6 282.5 282.4 282.3 282.2 282.1 282 281.9 281.8 281.7 281.6 281.5 281.4 281.3 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122232425262728293031 32 33 34 35 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w C21020 StormCAD Model.stsw 11 /15/2021 Profile Report Profile: STM 110 TO STM 106 STM 110 TO STM 106 Label: STM 110 Type: Catch Basin 286.5 I p : -Ar 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 Coats - 25yr Label: P24 Label: STM 108 Type: Conduit 106 Basin -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 Station (ft) Bentley Systems, Inc. Haestad Methods Solution Center 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 w Profile Report Profile: STM 113 TO STM 112 STM 113 TO STM 112 - Coats - 25yr Labe : STM 112 Type: Catch Basin -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 r� 4-0 O -r- _(D w 291.6 291.4 291.2 291 290.8 290.6 290.4 290.2 290 289.8 289.6 289.4 289.2 289 288.8 288.6 288.4 288.2 288 287.8 287.6 287.4 287.2 287 286.8 286.6 286.4 286.2 286 285.8 285.6 285.4 285.2 285 284.8 284.6 284.4 284.2 284 283.8 283.6 283.4 283.2 283 282.8 282.6 Profile Report Profile: STM 114 TO STM 110 STM 114 TO STM 110 - Coats - 25yr Label: STM 112 Type: Catch Basin 110 Basin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 116 TO STM 112 STM 116 TO STM 112 - Coats - 25yr Label: STM 116 Type: Catch Basin 296. 199999999999 I D : 334 295.999999999999 295.799999999999 295.599999999999 Abel: STM 115 295.399999999999 295.199999999999 Labe . e: Catch Basin 294.999999999999 294.799999999999 Type: Con 333 294.E 5 294.4 D: 33 294.2 294 293.8 293.6 293.4 293.2 293 292.8 292.6 292.4 n a e1: STI\ �••~+ 292.2 292 Type: Catch 291.8 � 291.6 ID: 18' 291. O 291.2 291 }+ 290. 290.6 290.4 /� 290.2 290 289.8 289. w 289.4 289.2 289 288.8 288.6 288.4 288.2 288 287.8 287.6 287.4 287.2 287 286.8 286.6 286.4 286.2 286 285.8 1 112 Basin -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 000-1 O W 287.0 28TYP 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 Profile Report Profile: STM 121 TO STM 103 STM 121 TO STM 103 - Coats - 25yr Label: P20 Type: Conduit ID: 133 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Station (ft) 103 Basin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 �1 �%-100 0 4--+ co _W W Label: STM 131 Type 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 Profile Report Profile: STM 131 TO STM 100 STM 131 TO STM 100 - Coats - 25yr Label: P14 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 132 TO STM 131 Label: s�TIN 132 TO STM 131 - Coats - 25yr Type: Catch Basin in. 179 279.900000000001 279.800000000001 279.700000000001 279.600000000001 279.500000000001 279.400000000001 279.300000000001 279.200000000001 279.100000000001 279.000000000001 278.900000000001 278.800000000001 278.700000000001 278.600000000001 =M0000000001 4R4.400000000001 "!rM'300000000001 2=.200000000001 278.1 O _ 278 +� 277.9 277.8 > 277.7 277.6 277.5 W 277.4 277.3 277.2 277.1 277 276.9 276.8 276.7 276.6 276.5 276.4 276.3 276.2 276.1 276 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122 23 24 25 26 27 28 29 30 3132 Station (ft) �1 sin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 291 Lcl�91 Ty pe:5 C 281 D 288. 288 287.5 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 Profile Report Profile: STM 133 TO STM 131 STM 133 TO 91hAil3dB�-Coats - 25yr Type: Conduit -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100 091015120 29 30 39 40 49 50 55160 65170 79 80 89 90 9a0(205 Station (ft) 1 131 Basin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Profile Report Profile: STM 134 TO STM 133 Label: S.P,TN 134 TO STM 133 - Coats - 25yr Type: Catch Basin 289.100000000001 289.000000000001 288.900000000001 288.800000000001 288.700000000001 288.600000000001 288.500000000001 288.400000000001 288.300000000001 288.200000000001 288.100000000001 288.000000000001 287.900000000001 287.800000000001 ,?AZ.700000000001 4OM600000000001 V00000000001 400000000001 ..300000000001 200000000001 287.1 4-0 287 cu 286.9 > 286.8 ^' 286.7 VJ 286.6 W 286.5 286.4 286.3 286.2 286.1 286 285.9 285.8 285.7 285.6 285.5 285.4 285.3 285.2 285.1 285 -2 -1 0 1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 2122232425262728293031 32 Station (ft) 2 sin StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 O a-J CO w 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 Profile Report Profile: STM 142 TO STM 100 STM 142 TO STM 100 - Coats - 25yr Label: STM 142 Label: STM 141 Type; CAtrh Racin T%mp• i'atrh Racin ID Label: STM 140 Type: Catch Basin -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w C21020 StormCAD Model.stsw 11 /15/2021 Profile Report Profile: STM 144 TO STM 142 STM 144 TO STM 142 Label: STM 144 T$y.pe: Catch Basin 283 I D : 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 Label: P10 Type: Conduit ID: 135 - Coats - 25yr 1 142 Basin 3 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 Station (ft) Bentley Systems, Inc. Haestad Methods Solution Center 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 145 TO STM 144 TM 145 TO SlMrM4 - Coats - 25yr Label: STM 45 Type: Conduit Type: Catch Basin ID: 125 290. 29 289.5 289 288.5 288 287.5 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 0 144 i Basin 5 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95100 0511015120 25130 35140145150 5516016517017518018519019!20(P05 Station (ft) C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 StormCAD [10.03.03.44] Page 1 of 1 Profile Report Profile: STM 202 TO STM 200 STM 202 TO STM 200 Label: STM 202 Type: Catch Basin Label: P02 ID: 156 Type: Conduit 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 272 271.5 271 270.5 270 269.5 269 268.5 268 267.5 267 266.5 266 265.5 265 264.5 264 263.5 263 262.5 262 261.5 261 - Coats - 25yr TM 200 Dutfall 153 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 w Profile Report Profile: STM 204 TO STM 202 STM 204 TO STM 202 - Coats - 25yr Label: STM 204 Type: Catch Basin 287 286.5 286 285.5 285 284.5 284 283.5 283 282.5 282 281.5 281 280.5 280 279.5 279 278.5 278 277.5 277 276.5 276 275.5 275 274.5 274 273.5 273 272.5 nhai- Pnd 202 Basin -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 Station (ft) StormCAD C21020 StormCAD Model.stsw Bentley Systems, Inc. Haestad Methods Solution Center [10.03.03.44] 11/15/2021 27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Swale Summary PROPOSED PROJECT INFORMATION: Project: Messer Parcels Location: 187 E. Stewart. St. Coats, NC Project Number: C21020 Date: 11/17/2021 Designed: ZA Checked: LL Outlet ID: Location Area (SF) C-Value Stress (psf) V10 (fps) Q10 (cfs) Channel Depth (ft) Width (ft) Slopes (X:1) Channel Slope Lining Type Swale 1 1.75 0.60 1.15 3.98 6.97 1.50 2 3 3.7 Bermudagrass Swale 2 1.17 0.60 1.37 14.00 4.68 1 1.48 1 3 4.59 Bermudagrass Swale 3 1.68 0.60 0.71 2.92 4.90 1.60 1 3 1.9 Bermudagrass Swale 4 1.80 0.60 1.05 3.80 6.84 1.51 2 3 3.3 Bermudagrass Swale 5 1.50 0.60 0.53 2.45 3.67 1.50 1 4 1.7 Bermudagrass *Note: Bermudagrass classified as Class B Retardance, Good stand, tall (average 12"). Channel Design TRAPEZOIDAL/TRIANGULAR SHAPE T M � � Channel Location: Swale 1 Estimate 10-yr Peak Runoff: Rational C 0.60 Intensity (in/hr) 7.81 Drainage Area 0.74 ac Qio 3.49 cfs Additional Flow cfs Po Total, Qdesign 3.49 cfs Channel Information: Channel Bottom Width, b 2.0 ft/ft Side Slope (x:1) 3.0 Channel Slope, S 0.037 ft/ft Flow Depth, d 0.50 ft Selected Channel Lining: Selected Channel Lining T Bermudagrass Maximum Permissible Velocity {Vmax) (fp 4 Permissible Shear Stress {tp} (psf) �-2 .10 Calculations: e 1.5 ft Side Slope Length, m 1.6 ft Top Width, T 5.0 ft Channel Area, A 1.75 sq ft Wetted Perimeter, PW 5.16 ft Hydraulic Radius, Rh 0.34 ft Mannings "n" 0.035 Calculated Flow Rate, Qcalc 6.97 cfs Calculated Velocity, Vcalc 3.98 fps Calculated Shear Stress, tcalc 1.15 psf Q calc % Q design? yes V calc <_ V max? yes t calc <_ t p? yes Channel Design TRAPEZOIDAL/TRIANGULAR SHAPE T M � � Channel Location: Swale 2 Estimate 10-yr Peak Runoff: Rational C 0.60 Intensity (in/hr) 7.81 Drainage Area 0.49 ac Qio 2.30 cfs Additional Flow 0.00 cfs Po Total, Qdesign 2.30 cfs Channel Information: Channel Bottom Width, b 1.0 ft/ft Side Slope (x:1) 3.0 Channel Slope, S 0.046 ft/ft Flow Depth, d 0.48 ft Selected Channel Lining: Selected Channel Lining T Bermudagrass Maximum Permissible Velocity {Vmax) (fp 4 Permissible Shear Stress {tp} (psf) �-2 .10 Calculations: e 1.4 ft Side Slope Length, m 1.5 ft Top Width, T 3.9 ft Channel Area, A 1.17 sq ft Wetted Perimeter, PW 4.04 ft Hydraulic Radius, Rh 1 0.29 ft Mannings "n" 1 0.035 Calculated Flow Rate, Qcalc 4.68 cfs Calculated Velocity, Vcalc 4.00 fps Calculated Shear Stress, tcalc 1.37 psf Q calc % Q design? yes V calc £ V max? yes t calc £ t p? yes Channel Design TRAPEZOIDAL/TRIANGULAR SHAPE T M � � Channel Location: Swale 3 Estimate 10-yr Peak Runoff: Rational C 0.60 Intensity (in/hr) 7.81 Drainage Area 0.83 ac Qio 3.87 cfs Additional Flow 0.00 cfs Po Total, Qdesign 3.87 cfs Channel Information: Channel Bottom Width, b 1.0 ft/ft Side Slope (x:1) 3.0 Channel Slope, S 0.019 ft/ft Flow Depth, d 0.60 ft Selected Channel Lining: Selected Channel Lining T Bermudagrass Maximum Permissible Velocity {Vmax) (fp 4 Permissible Shear Stress {tp} (psf) �-2 .10 Calculations: e 1.8 ft Side Slope Length, m 1.9 ft Top Width, T 4.6 ft Channel Area, A 1.68 sq ft Wetted Perimeter, PW 4.79 ft Hydraulic Radius, Rh 1 0.35 ft Mannings "n" 1 0.035 Calculated Flow Rate, Qcalc 4.90 cfs Calculated Velocity, Vcalc 2.92 fps Calculated Shear Stress, tcalc 0.71 psf Q calc % Q design? yes V calc £ V max? yes t calc £ t p? yes Channel Design TRAPEZOIDAL/TRIANGULAR SHAPE T M � � Channel Location: Swale 4 Estimate 10-yr Peak Runoff: Rational C 0.60 Intensity (in/hr) 7.81 Drainage Area 1.44 ac Qio 6.76 cfs Additional Flow cfs Po Total, Qdesign 6.76 cfs Channel Information: Channel Bottom Width, b 2.0 ft/ft Side Slope (x:1) 3.0 Channel Slope, S 0.033 ft/ft Flow Depth, d 0.51 ft Selected Channel Lining: Selected Channel Lining T Bermudagrass Maximum Permissible Velocity {Vmax) (fp 4 Permissible Shear Stress {tp} (psf) �-2 .10 Calculations: e 1.5 ft Side Slope Length, m 1.6 ft Top Width, T 5.1 ft Channel Area, A 1.80 sq ft Wetted Perimeter, PW 5.23 ft Hydraulic Radius, Rh 1 0.34 ft Mannings "n" 1 0.035 Calculated Flow Rate, Qcalc 6.84 cfs Calculated Velocity, Vcalc 3.80 fps Calculated Shear Stress, tcalc 1.05 psf Q calc % Q design? yes V calc £ V max? yes t calc £ t p? yes Channel Design TRAPEZOIDAL/TRIANGULAR SHAPE T M � � Channel Location: Swale 5 Estimate 10-yr Peak Runoff: Rational C 0.60 Intensity (in/hr) 7.81 Drainage Area 0.31 ac Qio 1.45 cfs Additional Flow cfs Po Total, Qdesign 1.45 cfs Channel Information: Channel Bottom Width, b 1.0 ft/ft Side Slope (x:1) 4.0 Channel Slope, S 0.017 ft/ft Flow Depth, d 0.50 ft Selected Channel Lining: Selected Channel Lining T Bermudagrass Maximum Permissible Velocity {Vmax) (fp 4 Permissible Shear Stress {tp} (psf) �-2 .10 Calculations: e 2.0 ft Side Slope Length, m 2.1 ft Top Width, T 5.0 ft Channel Area, A 1.50 sq ft Wetted Perimeter, PW 5.12 ft Hydraulic Radius, Rh 1 0.29 ft Mannings "n" 1 0.035 Calculated Flow Rate, Qcalc 3.67 cfs Calculated Velocity, Vcalc 2.45 fps Calculated Shear Stress, tcalc 0.53 psf Q calc % Q design? yes V calc £ V max? yes t calc £ t p? yes A underfoot ENGINEERING Riprap Outlet Protection Design Project: Messer Parcels Location: NC Highway 27 Coats, NC Project Number: C21020 Date: 1 1 / 17/2021 Designed: ZA Checked: LL Outlet ID: SCM 1 Pipe diameter= 24 inches Pipe slope= 1 % Roughness Coef.= 0.013 Full Flow Capacity= 1.26 cfs Inlcudes 1.1 Factor of Safety Full flow velocity= 0.40 ft/sec Lone from grapn above = Is grade of apron 10% or more: N Y/N Zone used = 2 Length = 12.0 ft. Outlet pipe diameter= 24 in. Width at Outlet = 6.0 ft. Outlet flowrate= 1.3 cfs Width at end of Pad= 19.9 ft. Outlet velocity= 0.40 ft/sec Stone diameter = 8 in. Material = Class B Thickness = 12 in. Zone Material Diameterj Thickness Length 1 Class A 4 6 4 x D(o) 2 Class B 8 12 6 x D(o) 3 Class 1 10 15 8 x D(o) 4 Class 1 10 15 8 x D(o) 5 Class 11 14 21 10 x D(o) 6 Class 11 14 21 10 x D(o) 7 Special study required Calculations based on NY DOT method - Pages 8.06.05 through 8.06.06 in NC Erosion Control Manual APPENDIX D: ENVIRONMENTAL EVALUATION 1149 Executive Circle, Suite C-1 Cary, NC 21511 NCBELS # C-3847 1 919.576.9733 underfoot Forward Thinking. Grounded Design. E N G I N E E R I N G www.underfootengineering.com \ \ 1 I I /• \\ \\\ \\ \ I I I I I \ 1 I I 11 / I I / I I 11 I % / 1 II l % l •� / j / l 1 1 1 I I / / UAILti I I � I I I I I I I I I I I I I /TI/ "n/1", SAGE ECOLOGICAL SERVICES —EST. 201E 1 kr 0 Inf' rmati' n nd An I sis N 1