Loading...
HomeMy WebLinkAboutNC0082694_Compliance Evaluation Inspection_20220210ROY COOPER corporrror ELIZABETH 5_ RISER Secretory $. DANIEL SMITH Alrrclor NORTH CAROL! NA Ertrfronmertrai Qualify February 10, 2022 CERTIFIED MAIL # 7018 3090 0001 2323 0416 RETURN RECEIPT REQUESTED Mr. Bill Trudnak, Public Works Director Town of Dallas 210 North Holland Street Dallas, NC 28034 Subject: Compliance Evaluation Inspection Notice of Violation and Intent to Assess Civil Penalty Tracking Number NOV-2022-PC-0041 Dallas WTP NPDES Permit No. NC0082694 Gaston County Dear Mr. Trudnak: Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on January 25, 2022, by Ori Tuvia. Zachary Foreman's cooperation during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report. At the time of the inspection it was discovered that the Waste Water Treatment backwash lagoon was overflowing and bypassing the treatment units. The overflow is in direct violation of the following permit statues: 1. Part II, Section C.2 , failure of Proper Operation and Maintenance "The Permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the Permittee to achieve compliance with the conditions of this permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the Permittee to install and operate backup or auxiliary facilities only when necessary to achieve compliance with the conditions of the permit [40 CFR 122.41(e)]. " Proper Operation and maintenance of the backwash lagoon level would have prevented the backwash from reaching a level that it would overflow. North Carolina Department of Emwiranmenial Quailly I Division of Water Resources Mooresville Regional offkc 1670 East Center Arexiue, State 301 I Mooresville, North Carolina 2 lIS 704663.1691 2. Part II, Section C.4(b)(2), Failure to give notice "Unanticipated bypass. The Permittee shall submit notice of an unanticipated bypass as required in Part II.E. 6. (24-hour notice)." No notice was given to Mooresville Regional Office staff that bypass has occurred. 3. Part II, Section C.4(c), Prohibition of Bypass "(1) Bypass from the treatment facility is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee for bypass, unless: (A) Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; (B) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate backup equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and (C) The Permittee submitted notices as required under Paragraph b. of this section. (2) Bypass from the collection system is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee for a bypass as provided in any current or future system -wide collection system permit associated with the treatment facility. (3) The Permit Issuing Authority may approve an anticipated bypass, after considering its adverse effects, if the Permit Issuing Authority determines that it will meet the three conditions listed above in Paragraph c. (1) of this section." Facility has failed to prevent the bypass. In addition to the bypass the following issues were observed and need to be addressed. • The chlorine curve was out of date and was last done in 2019. • The facility has been reporting Iron levels in ug/1 without conversion from mg/L; EDMR's need to be amended to reflect the change. • The drying beds are in need of maintenance, the drying bed walls had visible cracks and one of the drying beds was full of vegetation. A Notice of Violation and Notice of Recommendation for Enforcement, pursuant to G.S. 143-215.6A, may result in a civil penalty of not more than twenty-five thousand dollars ($25,000.00) per day, per violation and may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. You are requested to respond to this Notice in writing within ten (10) days of receipt indicating your Plan of Action to ensure future compliance. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov. Sincerely, ,-DocuSigned by: A W H Pam► F161 FB69A2D84A3... for W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources Cc: NPDES, MRO Files (Laserfiche) Picture 1. Overflowing lagoon, January 25, 2022.