Loading...
HomeMy WebLinkAbout20200597 Ver 2_Application Attachments_20220217AGENT AUTHORIZATION FORM CITY OF RALEIGH Project Name: Big Branch Interceptor Project Project Location: Raleigh, Wake County Date: September 2019 The City of Raleigh, undersigned, does hereby authorize: The Professional Engineers and Scientists VHB of (Contractor / Agent) (Name of consulting firm) to act on my behalf and take all actions necessary for the processing, issuance and acceptance of permits or certifications and any and all standard and special conditions attached. City of Raleigh Public Utilities Department Capital Improvement Program 1 Exchange Plaza #620 Raleigh, 27601 (919) 996-3528 I hereby certify the above information submitted in this application is true and accurate to the best of my knowledge. a1,4 lob, //n7 Matthew Cotton P.E. Date Construction Projects Administrator NORTH CAROLINA August 6, 2019 RE: NOTICE OF ENTRY ONTO LAND Dear Property Owner or Resident: As you may know, the City of Raleigh (the "City") is planning to replace the existing sewer pipe in your area as part of the Big Branch Interceptor Project. To investigate and design the Project properly, the City and/or its agents, such as engineers, surveyors or geologists, will need to perform environmental site work, consisting of wetland delineation and flagging.. This work is scheduled to begin on or after Monday August 26, 2019. Highfill Infrastructure Engineering is the design consultant and will be coordinating this work with the City. North Carolina General Statutes §§ 40A-11 and 136-120 authorize the City to enter your land after proper notice to make surveys, borings, examinations, and appraisals to carry out the Project. The City, however, prefers to first seek your permission as a courtesy, to expedite the process, and to address any concerns you might have. The City respectfully requests your cooperation in allowing the City and/or its agents to enter upon your land to do this examination and design work. Enclosed for your review and signature is a standard form, granting the City and its agents the temporary right to go on your land (but not inside any of your buildings) for the limited purposes set out in the form. If it is acceptable to you, please sign and return it to me at your earliest convenience. It is important to note that any individuals entering your property based on this notice or the enclosed form are instructed to protect all property that they encounter and to cooperate fully with you to prevent or minimize incidental damage to trees, shrubs, etc. If tenants are living at your property listed in this letter, then please share the contents of this letter with them. Later, if further research and site investigations indicate that the City needs to acquire easements on your property for the Project, then the City will engage you in negotiations and seek to purchase those easements based upon an estimate of fair market value One Exchange Plaza 1 Exchange Plaza, Suite 1020 Raleigh, North Carolina 27601 City of Raleigh Post Office Box 590 • Raleigh North Carolina 27602-0590 (Mailing Address) Printed on Recycled Paper Municipal Building 222 West Hargett Street Raleigh, North Carolina 27601 If you have any questions or need any additional information, please feel free to contact me at (919) 996-3528, email: matt.cotton@raleighnc.gov, or Eddie Sasser, Project Manager, Highfill Infrastructure at (919) 481-4342, email: esasser@hiepc.com. Additionally, the following link may be used to obtain updates on the project status: https://www.raleighnc. gov/proj ects/content/PubUtilAdmin/Articles/Proj ects/CIP/BigBranchInter ceptor.html Thank you in advance for your cooperation in this matter. Sincerely, iii, e-, , A Matt Cotton, P.E. Construction Projects Administrator Cc: Eddie Sasser, P.E. — Highfill Infrastructure Engineering One Exchange Plaza 1 Exchange Plaza, Suite 1020 Raleigh, North Carolina 27601 City of Raleigh Post Office Box 590 • Raleigh North Carolina 27602-0590 (Mailing Address) Printed on Recycled Paper Municipal Building 222 West Hargett Street Raleigh, North Carolina 27601 fires EBX Buffer Mitigation Banks Statement of Availability January 18, 2022 NC Division of Water Resources Stephanie Goss 512 N. Salisbury St. Archdale Building, 9th floor Raleigh, NC 27604 Re Project: Big Branch Sewer This document confirms that the City of Raleigh Public Utilities Department (Applicant) for Bpi Branch Sewer (Project) has expressed an interest to utilize 2,568.00 Square Feet of Riparian Buffer Mitigation Credits from one or both of the following banks, EBX-Neuse I, LLC Neuse Riparian Buffer Umbrella Mitigation Bank or EBX Upper Neuse Riparian Buffer Umbrella Mitigation Bank. Specific bank sites that will be debited will either be Buffalo Branch, Bucher, Selma Mill, Cedar Grove, Polecat, Stone Creek, Hannah Bridge, Meadow Spring, Poplar Creek, Uzzle and/or Hatley, all located in HUC 03020201. As the official Bank Sponsor, EBX-Neuse I, LLC and EBX, attests to the fact that mitigation is available for reservation at this time. These mitigation credits are not considered secured, and consequently are eligible to be used for alternate purposes by the Bank Sponsor, until payment in full is received from the Applicant resulting in the issuance of a Mitigation Credit Transfer Certificate by the bank acknowledging that the Applicant has fully secured credits from the bank and the Banker has accepted full responsibility for the mitigation obligation requiring the credits/units. The Banker will issue the Mitigation Credit Transfer Certificate within three (3) days of receipt of the purchase price. Banker shall provide to Applicant a copy of the Mitigation Credit Transfer Certificate and a documented copy of the debit of credits from the Bank Official Credit Ledger(s), indicating the permit number and the resource type secured by the applicant. A copy of the Mitigation Credit Transfer Certificate, with an updated Official Credit Ledger will also be sent to regulatory agencies showing the proper documentation. Please contact me at 854-900-3222 or dlach@res.us if you have any questions or need additional information. Best Regards, 12,./ _,.,_ David Lach Resource Environmental Solutions, LLC 701 E. Bay Street, Suite 306 Charleston, SC 29403 Bank Sponsor — EBX-Neuse I, LLC or Environmental Banc & Exchange (EBX) E. MILLBROOK RD PROJECT LOCATION SERIES SS-1 Right -of -Way Obstruction Notes: Lane and Sidewalk closures or detours: Prior to any lane or sidewalk obstruction, the contractor or engineer shall submit a traffic control and/or pedestrian plan along with a Right -of -Way Services Application to request the obstruction prior to the start of work. rightofwayservices@raleighnc.gov for approval. The City of Raleigh requires an approved Right -of -Way Obstruction Permit for work on any public street or sidewalk and NCDOT road within Raleigh's Jurisdiction. All Traffic Control Signage and practices shall adhere to the Manual on Uniform Traffic Control, and the latest edition of the NCDOT "Standard Specification for Roadway Structures", NCDOT "Roadway Standard Drawing Manual", and the NCDOT supplement to the MUTCD. Allpublic sidewalks must be accessible topedestrians who are visuallyimpaired and/or p people with mobility concerns. Existing and alternative pedestrian routes during construction shall be required to be compliant with the Public Rights of Way Accessibility Guidelines (PROWAG), the ADA Standards for Accessible Design and the Manual on Uniform Traffic Control Devices (MUTCD). Prior to the start of work, the Client shall schedule a Pre -Construction meeting with the Engineering Inspections Coordinator to review the specific components of the approved plan, and ensure all permits are issued. All permits must be available and visible on site during the operation. BIG BRANCH SS IMPROVEMENTS RALEIGH, NC RALEIGH WATER PROJECT NO. PU94-18 PROJECT LOCATION-\ SERIES SS-3 ("1-VICINITY MAP SCALE: 1 "=1500' ATTENTION CONTRACTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Works Department at (919) 996-2409, and the Public Utilities Department at (919)-857-4540 at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. E. MILLBROOK RD SITE PERMITTING APPROVAL Water and Sewer Permits (If applicable) SCHEDULE OF DRAWINGS SHEET TITLE COVER AND GENERAL NOTES COVES C-0.0 C-0.1 VICI\ITY IVAP A\D SCHEDULE OF DRAWI\GS GENERAL \OTES, LECE\D, A\D A33EVIATIONS SHEET LAYOUT AND CONTROL POI\T LOCATIO\S GRAVITY SEWER DESIGN SS-1 .0 PLA\ A\D P0FILE, STA. 12+77 TO STA. 17+00 SS-1 .1 PLA\ A\D PROFILE, STA. 17+00 TO STA. 28+00 SS-1 .2 PLA\ A\D PROFILE, STA. 28+00 TO STA. 38+00 SS-1 .3 PLA\ A\D PROFILE, STA. 38+00 TO STA. 46+50 SS-1 .4 PLA\ A\D PROFILE, STA. 46+50 TO STA. 57+00 SS-1 .5 PLA\ A\D PROFILE, STA. 57+00 TO STA. 66+00 SS-1.6 SS-1.7 SS-1.8 SS-2.0 SS-3.0 PLA\ A\D PROFILE, STA. 66+00 TO STA. PLA\ A\D PROFILE, QUAIL HOLLOW DIVE PLA\ A\D PROFILE, CHESWICK DRIVE PLA\ A\D PROFILE, COVIPTO\ GOAD PLA\ A\D PROFILE, TALL PI\ES COURT 74+19 DETAILS ED-1.0 ED-2.0 ED-3.0 ED-4.0 MD-1.0 VD-2.0 SD-1 .0 SD-2.0 SD-3.0 TD-1.0 TD-2.0 EOSIO\ CO\TOOL DETAILS EOSIO\ CO\TOOL DETAILS EOSIO\ CO\TOOL DETAILS EOSIO\ CO\TOOL DETAILS VISCELLANEOUS DETAILS VISCELLANEOUS DETAILS STANDARD DETAILS STANDARD DETAILS STANDARD DETAILS TRAFFIC CO\TOOL DETAILS TRAFFIC CO\TOOL DETAILS The City of Raleigh consents to the connection and extension of the City's Public Sewer System as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 The City of Raleigh consents to the connection and extension of the City's Public Water System as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # N/A The City of Raleigh consents to the connection and extension of its public sewer system and extension of the private sewer collection system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # N/A CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. Electronic Approval: This approval is being issued electronically. This approval is valid only upon the signature of a City of Raleigh Review Officer below. The City will retain a copy of the approved plans. Any work authorized by this approval must proceed in accordance with the plans kept on file with the City. This electronic approval may not be edited once issued. Any modification to this approval once issued will invalidate this approval. City of Raleigh Development Approval City of Raleigh Review Officer \\\\W1111111111///,,/ ,�`*' ' 0 EESSIAR��4"9 / A�r1 O. A 026481 E. I / ` _ j 2 l -„ FNGI NEE » ,\.��` ,q;'D 0. SASS<`\\ 0//11111111110\ SEAL NOT VALID UNLESS SIGNED AND DATED \\\\\1111111111////// 0,�FESCAR"14�''% 0 r SEAL 046286 ll-ot-z6 . %/,,,��/REY 16 • `1\\\\ SEAL NOT VALID UNLESS SIGNED AND DATED Project Data Sheet DEVELOPMENT SERVICES DEPARTMENT Development Services Customer Service Center 1 Exchange Plaza, Suite 400 Raleigh, NC 27601 1919-996-2495 Litchford Satellite Office 18320 - 130 Litchford Road I Raleigh, NC 27601 1919-996-4200 GENERAL INFORMATION Development Name: Big Branch Sanitary Sewer Improvements Proposed Use: N/A Property Address(es): PO BOX 590 RALEIGH, NC 27602 Wake County Property Identification Number(s) (PIN) for each parcel to which these guidelines will apply: PIN #1705959751 PIN # PIN # PIN # What is the project type? ❑Apartment ❑Bank oElderly Facility oHospital oHotel/Motel olndustrial Building oMixed Residential oNon-Residential Condo Office oReligious Institution oResidential Condo ❑Retail oSchool oShopping Center oSingle Family Residential oTelecommunication Tower Townhouse BOther Scope of Work: Improvements to existing sanitary sewer: Upsize approximately 1,380 LF of 8-inch (to 10-inch) and 300 LF of 12-inch (to 15-inch) gravity sewer tributary to Big Branch Interceptor. Upsize approximately 515 LF of 15-inch (to 18-inch) and 6,150 LF of 18-inch (to 30-inch) of the Big Branch Interceptor. Install approximately 1,330 LF of 18-inch CIPP lining. FOR APARTMENTS, CONDOS, AND TOWNHOMES ONLY 1. Total number of townhouse lots: N/A Number attached: N/A Number detached: N/A 2. Total number of apartment or condominium units: N/A 3. Total number of Congregate Care or Life Care Dwelling units: N/A 4. Overall total number of dwelling units (from 1-3 above): N/A 5. Number of bedroom units: 1BR N/A 2BR N/A 3BR NIA 4BR or more NIA 6. Overall unit(s) per acre densities per zoning district(s): N/A DEVELOPMENT TYPE AND SITE DATA TABLE (applicable to all developments) Zoning Information Building Information Zoning District(s): Mainly R-4, Others. CX-3-PL, PD, OX-3, R-6, RX-3, RX-3-CU Proposed use of building(s): N/A If more than one district, provide acreage of each: N/A Proposed Sq. Ft. of building(s) gross: N/A Overlay District(s): N/A Existing Sq. Ft. of building(s) gross: N/A Total site acreage: N/A Total Sq. Ft. gross (existing and proposed): N/A Off street parking: Required N/A Provided N/A Proposed height of building(s): N/A COA (Certificate of Appropriateness) case # N/A FAR (floor area ratio) %: N/A BOA (Board of Adjustment) case # A - N/A Building lot coverage %: N/A CUD (Conditional Use District) case # Z - N/A Inside City Limits? • Yes • No STORMWATER INFORMATION Existing impervious surface: N/A acres/square feet Proposed impervious surface: N/A acres/square feet Neuse River buffer: Ekes •No Wetlands: ['Yes •No Flood Hazard Area: ❑ Yes ENo If yes, Alluvial Soils: Yes,CM Flood Study:372o1775001:2 FEMA Map Panel #: 1716,1715,17( 37201 Total disturbed area: 8.25 ACRES acres/square feet 3720170500 PAGE 1 OF 1 WWW.RALEIGHNC.GOV REVISION 03.22.16 PUBLIC IMPROVEMENT QUANTITIES PHASE NUMBER NUMBER OF LOTS LOT NUMBER(S) BY PHASE NUMBER OF UNITS LIVABLE BUILDINGS OPEN SPACE NUMBER OF OPEN SPACE LOTS PUBLIC WATER (LF) PUBLIC SEWER (LF) PUBLIC STREET (LF) - FULL PUBLIC STREET (LF) - PARTIAL PUBLIC SIDEWALK (LF) WATER SERVICE STUBS SEWER SERVICE STUBS PHASE 1 0 0 0 0 0 0 0 10,000 0 0 0 0 0 HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd., Suite 201 Cary, North Carolina 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service is our passion. HIGHFILL PROJ. NO. RAL1801 RALEIGH WATER PROJ. NO. PU94-18 NOVEMBER 2021 0 z 0 0 LL 0 IMPROVEMENTS cn 0 Q m GENERAL NOTES: 39. IN LOCATIONS WHERE THE SANITARY SEWER IS INSTALLED UNDER A STORM CULVERT AND OF THE STORM CULVERT, REMOVE THE STORM CULVERT TO THE NEAREST JOINT AND INSTALL SEWER. INSTALL STORM CULVERT TO PRE-EXISTING SLOPE. IF THE SANITARY SEWER IS OF THE STORM CULVERT, INSTALL SUPPORTS UNDER THE STORM CULVERT DURING INSTALLATION SANITARY SEWER. PROJECT NOTES: NEAR THE END SANITARY NOT NEAR THE END OF RIGHTS -OF -WAY AND APPROVED BY BE RESPONSIBLE FOR ANY AND ALL COSTS WITH PROPERTY TO THE ENGINEER EVERY POSSIBLE EASEMENTS. WORK. WASTEWATER FLOWS THE ENGINEER, A FLOW DURING BE ON SITE IN THE FULLY CONTAINED BY UNTIL THE PROBLEM IS INTO TRENCHES FINES IMPOSED ON THE BE PAID BY THE DAY. OVERNIGHT TERMINATE EACH END SPECIFICATIONS. INTERNALLY MANAGER, AND CITY OF EROSION CONTROL BUT PRIOR TO MEASURES, INCLUDING S&E PLAN ARE THAT THESE AND SEDIMENT BY THE INSTALLATION OF CONSTRUCTION. NECESSARY TO OF CONSTRUCTION HAVE BEEN STABILIZED. OR AFTER EACH BE REPAIRED OR IN THE CONSTRUCTION CONTROL ON THE DEMLR WEBSITE 1 _-1 1-E-1D 1 LRLC . ABBREVIATIONS: I 1 1 1 Ct CO Et CO o' CO CC CD } m LEGEND 1. EXISTING SURVEY DATA PROVIDED BY THE WOOTEN COMPANY FOR ENGINEERING PURPOSES ONLY, NOT FOR RECORDATION. ELEVATIONS SHOWN ARE BASED ON NAVD88, HORIZONTAL DATUM IN NAD83. 2. THE DRAWINGS DO NOT SHOW ALL HOMES AND BUSINESSES IN THE PROJECT AREAS OR OTHER EXISTING UTILITIES. THE CONTRACTOR IS ADVISED THAT THE AREAS ARE CONGESTED WITH HOMES, BUSINESSES, AND UTILITIES. THE CONTRACTOR SHALL MAKE NECESSARY SITE INVESTIGATIONS TO DETERMINE ACTUAL UTILITY LOCATIONS, OBSTACLES, HOMES, BUSINESSES, ETC. PRIOR TO BIDDING. 3. BUILDING LOCATIONS ARE APPROXIMATE AND ARE SHOWN FOR INFORMATIONAL PURPOSES ONLY. NOT ALL BUILDINGS ARE SHOWN. 4. WORK SHALL COMPLY WITH APPLICABLE STATE, FEDERAL, AND LOCAL CODES. NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY CONTRACTOR AT ITS EXPENSE, UNLESS PREVIOUSLY OBTAINED BY THE OWNER AND PROVIDED IN THE CONTRACT DOCUMENTS. 5. THE CONTRACTOR SHALL HAVE A COMPLETE SET OF CONTRACT DOCUMENTS AS WELL AS ALL PERMIT APPROVALS AND EASEMENTS ON THE JOB SITE AT ALL TIMES. CONTRACTOR SHALL HAVE DOCUMENTS AND PERMITS AVAILABLE AT STAGING AREAS. 6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD ANY FIELD CONDITIONS BE ENCOUNTERED THAT VARY FROM THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS. 7. DEVIATION FROM THE CONTRACT DOCUMENTS WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER OR THE ENGINEER MAY BE CAUSE FOR THE WORK TO BE DEEMED UNACCEPTABLE. 8. AT LEAST FIVE BUSINESS DAYS PRIOR TO COMMENCING CONSTRUCTION, CONTRACTOR SHALL NOTIFY ENGINEER AND APPLICABLE REGULATORY AGENCIES THAT HE IS PREPARED TO COMMENCE. 9. CONTRACTOR SHALL CALL NC ONE CALL FOR UTILITY LOCATIONS PRIOR TO DIGGING. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK WITH DUKE ENERGY. SUPPORT EXISTING UTILITY POLES AS REQUIRED FOR EXCAVATION AND INSTALLATION OF THE WORK. COSTS OF SUCH WORK SHALL BE PAID BY CONTRACTOR. 11. BURIED TELEPHONE AND CATV CABLES (FIBER OPTICS AND CONVENTIONAL) ARE KNOWN TO VARY DUE TO INSTALLATION TECHNIQUES. CONTRACTOR SHALL COORDINATE WORK WITH CONFLICTING TELEPHONE AND CATV CABLES AS INCLUDED IN THE PROJECT SCHEDULE AND IT IS THE EXPLICIT RESPONSIBILITY OF CONTRACTOR TO ASSURE THAT THE PROJECT SCHEDULE INCLUDES THE NECESSARY COORDINATION. 12. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS. THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL EXPLORE THE AREA AHEAD OF EXCAVATION OPERATIONS BY OBSERVATION, ELECTRONIC DEVICES, HAND DIGGING, AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES TO DETERMINE THE ACTUAL LOCATION OF ALL EXISTING UTILITIES IN AN EFFORT TO AVOID INFLICTING DAMAGE TO THOSE UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY RELOCATION COSTS IF REQUIRED FOR CONTRACTOR'S METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM DAMAGE TO THE EXISTING UTILITIES ARISING FROM CONSTRUCTION OF THIS PROJECT. SUCH COSTS INCLUDE LOSS OF UTILITY REVENUES. IF NECESSARY, CONTRACTOR SHALL ARRANGE FOR RELOCATION OR TEMPORARY SUPPORT OF EXISTING UTILITIES SUCH AS POLES, CONDUITS, CABLES, WATER AND SEWER MAINS, ETC. 13. CONTRACTOR SHALL MAKE EVERY EFFORT TO PRESERVE PROPERTY IRONS, MONUMENTS, OTHER PERMANENT POINTS AND LINES OF REFERENCE AND CONSTRUCTION STAKES. PROPERTY IRONS, MONUMENTS, AND OTHER PERMANENT POINTS OF REFERENCE DESTROYED BY THE CONTRACTOR SHALL BE REPLACED BY A PROFESSIONAL LAND SURVEYOR AT THE CONTRACTOR'S EXPENSE. 14. CONTRACTOR IS RESPONSIBLE FOR ALL SURVEY REQUIRED FOR CONSTRUCTION. 15. CONTRACTOR SHALL CLEAR AND GRUB THE CONSTRUCTION CORRIDOR AND ALL UTILITY EASEMENT ONLY TO THE EXTENT REQUIRED FOR SANITARY SEWER MAIN INSTALLATION. CONTRACTOR SHALL MAKE EVERY EFFORT TO PROTECT TREES THAT WILL NOT BE REMOVED DURING CONSTRUCTION. 16. CONTRACTOR ACTIVITY SHALL BE LIMITED TO STREET RIGHTS -OF -WAY AND CITY EASEMENTS. 17. CONTRACTOR SHALL MAINTAIN INGRESS/EGRESS TO EACH PROPERTY AT ALL TIMES. 18. PRIOR TO DISTURBANCE, CONTRACTOR SHALL VIDEOTAPE SEWER ALIGNMENT INCLUDING EACH DRIVEWAY, SIDEWALK, STRUCTURE, ETC., TO BE DISTURBED. EACH SHALL BE RESTORED TO ITS PRECONSTRUCTION CONDITION OR BETTER. VIDEO SHALL BE SUBMITTED TO ENGINEER PRIOR TO WORK. 19. CONTRACTOR SHALL RESTORE/REPLACE ALL DISTURBED SIGNS, MAILBOXES, STORM DRAINS, ETC. TO ORIGINAL CONDITION AND LOCATION AS SOON AS THE CONSTRUCTION PROGRESSES BEYOND THAT LOCATION. IN NO CIRCUMSTANCES SHALL POSTAL SERVICE BE INTERRUPTED TO PROPERTIES ALONG THE CONSTRUCTION CORRIDOR. 20. ALL ROADSIDE DITCHES DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO PRE -CONSTRUCTION CONDITION OR BETTER AND STABILIZED WITH STRAW AND NET MATTING UNLESS OTHERWISE INDICATED. 21. ALL MATERIAL CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO PERFORM THE WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFF SITE. NO BURNING WILL BE ALLOWED. 22. GRAVEL DRIVEWAYS SHALL BE RESTORED WITH 6" COMPACTED STONE FOR THE FULL WIDTH. 23. RELATIONSHIP OF SANITARY SEWER TO EXISTING UTILITIES (15A NCAC 02T .0305) A. SANITARY SEWER SHALL MAINTAIN MINIMUM VERTICAL SEPARATION OF 18" FROM STORM SEWERS. B. SANITARY SEWER SHALL MAINTAIN MINIMUM VERTICAL SEPARATION OF 18" FROM WATER MAINS, OR A HORIZONTAL MINIMUM SEPARATION OF 10'. 24. AT LOCATIONS WHERE SANITARY SEWER MUST BE INSTALLED WITH LESS THAN 18" SEPARATION FROM STORM DRAINS DUE TO SURROUNDING CONDITIONS, THE TRENCH SHALL BE BACKFILLED WITH CLASS M (FLOWABLE FILL) CONCRETE UP TO THE OUTSIDE DIAMETER OF EACH PIPE. SEE DETAIL 03-13/MD-1.0. 25. CONTRACTOR SHALL CONFINE WORK HOURS FROM 7:00 AM TO 6:00 PM MONDAY THROUGH FRIDAY UNLESS APPROVED BY OWNER. 26. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL, AND ERECT AND MAINTAIN AT ALL TIMES DURING THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO ENSURE THE SAFETY OF THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNAGE SHALL BE IN ACCORDANCE WITH THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD) AS SUPPLEMENTED BY THE NCDOT. 27. CONTRACTOR SHALL NOTIFY HOME AND BUSINESS OWNERS IN WRITING AT LEAST 7 DAYS PRIOR TO CONSTRUCTION THAT CONSTRUCTION ACTIVITY WILL TAKE PLACE IN THE VICINITY OF THEIR PROPERTY. 28. IF CITY OR STATE DOT ALLOWS EXCAVATED MATERIAL STORAGE ON PAVEMENT, A LAYER OF COARSE SAND, SCREENINGS OR ACCEPTABLE ALTERNATIVE SHALL BE PLACED ON THE PAVEMENT PRIOR TO DEPOSITION OF EXCAVATED MATERIAL. 29. LANE CLOSURES OR CONSTRUCTION SHALL NOT OCCUR ON OPPOSITE SIDES OF A STREET OR INTERSECTION SIMULTANEOUSLY. 30. ALL TRAFFIC SHALL BE RESTORED TO TWO-WAY TRAFFIC AT THE END OF EACH WORK DAY. 31. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS FROM CITY OF RALEIGH INCLUDING BUT NOT LIMITED TO STREET CUT PERMITS AND LANE CLOSURE PERMITS, AT LEAST 72 HOURS PRIOR TO COMMENCEMENT OF WORK. 32. PAVEMENT CUTS SHALL BE SAW CUT ALONG A STRAIGHT CONTINUOUS EDGE. 33. CONTRACTOR SHALL FURNISH AND INSTALL SHEETING REQUIRED FOR THE INSTALLATION OF THE UTILITY. EXCAVATIONS SHALL BE KEPT WITHIN THE DESIGNATED EASEMENT AND RIGHT-OF-WAY WIDTHS. EXCAVATION WITH PAVED AREAS SHALL BE KEPT TO A MINIMUM. SHEETING SHALL BE INSTALLED AS REQUIRED TO PROTECT EXISTING UTILITIES. 34. CONTRACTOR SHALL REMOVE AND REINSTALL EXISTING FENCES AS REQUIRED FOR CONSTRUCTION. ADDITIONAL FENCE MATERIALS REQUIRED SHALL BE PROVIDED BY CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 35. CONCRETE CURBS AND DRIVEWAYS SHALL BE REPLACED TO THE FIRST EXPANSION JOINT BEYOND THE TRENCH EXCAVATION LIMITS AND TO THE FULL WIDTH. CURBS AND CONCRETE DRIVEWAYS SHALL MATCH EXISTING. 36. EMERGENCY VEHICLE ACCESS AND ACCESS TO FIRE HYDRANTS SHALL BE MAINTAINED AT ALL TIMES. 37. ACCESS TO BUSINESS AND RESIDENTIAL SHALL BE MAINTAINED AT ALL TIMES. 38. BORE AND JACK PIT LOCATIONS MAY BE SHOWN ON THE PLANS AND MAY BE SHOWN WITH DIMENSIONS. THE LOCATIONS AND DIMENSIONS SHOWN ARE TO CONVEY GENERAL INTENT OF THE LAYOUT. CONTRACTOR SHALL SIZE AND LOCATE PITS AS REQUIRED FOR WORK AND WITHIN EASEMENTS AND RIGHTS OF WAY SHOWN. AWWA - AMERICAN WATER WORKS ASSOCIATION PL - PROPERTY LINE CL - CENTERLINE PP - POWER POLE CB - CATCH BASIN PSI - POUNDS PER SQUARE INCH CMP - CORRUGATED METAL PIPE PV - PLUG VALVE CONC - CONCRETE PVC - POLYVINYL CHLORIDE CPP - CORRUGATED PLASTIC PIPE PVMT - PAVEMENT CT - COURT R/W or ROW - RIGHT-OF-WAY DI - DUCTILE IRON R or RAD - RADIUS DIP - DUCTILE IRON PIPE RCP - REINFORCED CONCRETE PIPE DR - DRIVE REQ'D - REQUIRED EX - EXISTING RD - ROAD EOP - EDGE OF PAVEMENT RJ - RESTRAINED JOINT FM - FORCE MAIN STA - STATION GV - GATE VALVE SR - SECONDARY ROAD (STATE) HDPE - HIGH DENSITY POLYETHYLENE THK - THICK INV - INVERT TOS - TOP OF SLAB IP - IRON PIPE LSE - LANDSCAPE EASEMENT TS&V - TAPPING SLEEVE AND VALVE TYP. - TYPICAL LF - LINEAR FEET U/G - UNDERGROUND L.O.D - LIMITS OF DISTURBANCE U.N.O. - UNLESS NOTED OTHERWISE MIN - MINIMUM UT - UNDERGROUND TELEPHONE MH - MANHOLE W/ - WITH MJ - MECHANICAL JOINT WL - WATER LINE NIC - NOT IN CONTRACT OC - ON CENTER WWF - WELDED WIRE FABRIC OR FENCE NTS - NOT TO SCALE # or LB - POUNDS PE - PLAIN END 5/SD-1 - DETAIL CROSS-REFERENCE (DETAIL 5 PJ - PUSH -ON JOINT ON SHEET SD-1 IN THIS EXAMPLE) EROSION CONTROL AND CONSTRUCTION SEQUENCE: 1 I 1 REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING z N 0 o rn REVISION SYMBOL (NEW) SYMBOL (EX.) DESCRIPTION UTILITY PEDESTAL (SIZE/SHAPE VARIES) 1. ACCESS WORK THE NEGOTIATING ASSOCIATED OWNERS PRIOR 2. TRAFFIC SITUATION. 3. STREET CONTRACTOR 4. THE DURING DETAILED CONSTRUCTION. EVENT 5. IF, AT THE RESOLVED DURING OWNER CONTRACTOR. 6. CONTRACTOR BYPASS 7. ALL OF TRACER 8, CONTRACTOR g ALL 10. NEW COATED EROSION CONTROL SHALL BE ALONG THE EXISTING SEWER EASEMENTS OR WITHIN EXISTING ROAD SHALL BE MAINTAINED WITHIN THE EASEMENTS AND RIGHTS -OF -WAY UNLESS OTHERWISE INDIVIDUAL PROPERTY OWNERS AND/OR THE ENGINEER. THE CONTRACTOR SHALL WITH PROPERTY OWNERS FOR SUCH ALTERNATE ACCESS AND SHALL PAY WITH SUCH ALTERNATE ACCESS AS SPECIFIED ABOVE. ALL SUCH NEGOTIATIONS SHALL BE IN WRITING, AND COPIES OF THE AGREEMENTS SHALL BE SUBMITTED TO USING THE ACCESS. CONTROL DETAILS, DRAWINGS, OR SPECIFICATIONS ARE NOT INTENDED TO ADDRESS RIGHTS -OF -WAY ARE SHOWN. CONTRACTOR SHALL CONFINE WORK WITHIN EXISTING SHALL OBTAIN ADDITIONAL CONSTRUCTION EASEMENTS IF NEEDED TO COMPLETE CONTRACTOR IS RESPONSIBLE FOR HANDLING AND ACCOMMODATING ALL EXISTING THE WORK. THE CONTRACTOR WILL BE REQUIRED TO SUBMIT FOR APPROVAL BY PLAN OF THE METHOD THE CONTRACTOR PROPOSES TO MAINTAIN THE EXISTING WHEN BYPASS PUMPING IS USED, AN IDENTICAL STANDBY PUMP(S) SHALL OF FAILURE OF THE PRIMARY PUMP(S). ANY TIME DURING CONSTRUCTION, EFFLUENT FROM THE EXISTING SEWER IS NOT BYPASS SYSTEM, SERVICE WILL BE RESTORED AND WORK SHALL BE SUSPENDED TO THE SATISFACTION OF THE ENGINEER. THIS INCLUDES WASTEWATER FLOWING EXCAVATION WORK. SEWER SYSTEM OVERFLOWS WILL NOT BE TOLERATED. ALL 0 0 e TREE/SHRUB (DIA. & TYPE SOMETIMES NOTED) OQ 00 SEWER CLEAN -OUT 100 - -100- - CONTOUR + 100 + 100 SPOT ELEVATION �/�J WOODS LINE, CLEARING LIMIT CL- 1 I I cJ co N .- 10/15/20 05/07/20 0 0 0 1, I- 0 S OS10 FO MH SEWER, STORMWATER, & FIBER OPTIC 1111 CATCH BASIN/GRILL BASIN ������i������� I WELL 0 �, POWER OR TELEPHONE POLE (1 FIRE HYDRANT ASSEMBLY AND ASSOCIATED WITH OVERFLOWS CAUSED BY THE CONTRACTOR'S WORK SHALL SHALL MAKE TEMPORARY TIE-INS, IF NEEDED, AT THE END OF EACH WORK PUMPING IS NOT ALLOWED WITHOUT WRITTEN APPROVAL BY THE OWNER. NON-FERROUS PIPES SHALL BE INSTALLED WITH TRACER WIRE AND WARNING TAPE. WIRE AT VALVE BOX OR MANHOLE. SEE DETAILS FOR INSTALLATION. SHALL PERFORM SITE RESTORATION AS CONSTRUCTION PROGRESSES. WORK SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH STANDARD DETAILS AND MANHOLES SHALL BE POLYMER CONCRETE MANHOLES OR PRECAST CONCRETE MANHOLES WITH A POLYUREA OR EPDXY COATING. NOTES: Wv GATE VALVE I•I 101 BALL VALVE - E - - UNDERGROUND / OVERHEAD POWER 1. CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. THE COC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (E-N01) FORM AT CECI.HC.GHV/NCGU1. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF UT UT UNDERGROUND TELEPHONE - - - TEL- OVERHEAD TELEPHONE THE PLAN MUST BE KEPT ON SITE AND ACCESSIBLE DURING INSPECTION. 2. CONTRACTOR SHALL SCHEDULE A PRE -CONSTRUCTION MEETING WITH THE CITY OF RALEIGH STORMWATER INSPECTIONS GROUP A MINIMUM OF 3 WORKING DAYS PRIOR TO BEGINNING LAND DISTURBING ACTIVITIES BY CONTACTING CITY OF RALEIGH REGIONAL CONTACT AT (919) 279-1308 OR SCHEDULING THROUGH PERMIT AND DEVELOPMENT PORTAL: H I II- -11-1-1, '1 :'"_I I LEI1-"""_ E' - I LEI-- I E:_'H II -C-1" H' I'_. '_,EC-`_)-H l E- 'H _ Ii E . 3. CONTRACTOR SHALL CONTACT DEMLR RALEIGH REGIONAL OFFICE (919) 791-4200 AT LEAST 48 HOURS PRIOR TO COMMENCING THE LAND -DISTURBING ACTIVITY. 4. CONFIRM LOCATIONS OF AND CONSTRUCT OR INSTALL NECESSARY EROSION CONTROL DEVICES AS INDICATED ON THE DRAWINGS. INSTALL ALL OTHER NECESSARY EROSION CONTROL MEASURES WHETHER OR NOT INDICATED ON THE DRAWINGS IN ACCORDANCE WITH THE SPECIFICATIONS. LIMIT CLEARING AND LAND DISTURBING ACTIVITY TO ONLY THE AREA NECESSARY TO INSTALL THE PERMITTED MEASURES. 5. CALL THE RAPID RESPONSE NUMBER(919)857-4412 TO SCHEDULE A STORMWATER SITE INSPECTION OR SUBMIT THROUGH PERMIT AND DEVELOPMENT PORTAL (SEE LINK ABOVE). UPON APPROVAL OF THE STORMWATER SITE INSPECTION, PERMITTED LAND DISTURBANCE MAY COMMENCE. 6. BEGIN CONSTRUCTION AND INSTALLATION OF INFRASTRUCTURE. DEPENDING ON CONSTRUCTION STAFFING, OPERATIONS MAY OCCUR IN PARALLEL. LAND DISTURBING OPERATIONS INCLUDE: 6.1. LINEAR PIPE LINE INSTALLATION 6.2. CASING PIPE INSTALLATION BY BORE AND JACK METHOD 6.3. GRADING 7. STOCKPILED FILL MATERIAL, IF NOT REMOVED FROM SITE, SHALL BE PROTECTED FROM SEDIMENTATION AND RUNOFF BY COVERING OR INSTALLING EROSION CONTROL MATTING. 8. GRADED AREAS MUST BE STABILIZED UPON COMPLETION WITH TEMPORARY SEEDING AND ROLLED EROSION CONTROL MATTING WITHIN 7 DAYS. 9. BACKFILL AND ESTABLISH FINISH GRADES AS QUICKLY AS POSSIBLE AFTER PIPES HAVE BEEN INSTALLED. CONTRACTOR SHALL APPLY TEMPORARY SEEDING OVER BACKFILLED AREAS AT THE END OF EACH WORK DAY. 10. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT >_ 1 INCH. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. 11. ONCE CONSTRUCTION ACTIVITY IN COMPLETE FOR EACH AREA, CONTRACTOR SHALL APPLY PERMANENT SOIL VEGETATION WITH PERMANENT SEEDING, FERTILIZER, MULCH AND TACK. 12. SITE MUST BE STABILIZED PRIOR TO SCHEDULING FOR FINAL APPROVAL. GRASS UTILIZED AS PERMANENT GROUND COVER MUST BE AT A MOWABLE HEIGHT THAT GENERALLY PROVIDES AT LEAST 80% COVERAGE THROUGHOUT THE SITE, WITH NO LARGE BARE PATCHES OR EVIDENCE OF EROSION. 13. CONTRACTOR CAN REQUEST FINAL INSPECTION WITH CITY INSPECTOR THROUGH THE PERMIT AND DEVELOPMENT PORTAL (SEE LINK ABOVE). 14. 30 DAYS AFTER PROJECT INSPECTOR OR ENGINEER HAS DETERMINED THAT FINAL SITE HAS BEEN ADEQUATELY STABILIZED WITH PERMANENT SOIL VEGETATION, CONTRACTOR SHALL RETURN TO THE SITE AND REMOVE ALL TEMPORARY MEASURES. CONTRACTOR SHALL INSTALL PERMANENT STABILIZATION TO ALL AREAS DISTURBED BY THE TEMPORARY MEASURES. 15. WHEN THE PROJECT IS COMPLETE, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCGO1 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (E-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE E- NOT HAS BEEN FILLED OUT. RALEIGH STANDARD UTILITY NOTES: GAS LINE W WATER LINE - SEWER LINE 1. CONTRACTOR SHALL SCHEDULE AN ON -SITE MEETING WITH ENGINEER, CITY PROJECT STORMWATER CONTROL INSPECTOR AS FOLLOWS: A. PRIOR TO BEGINNING ANY LAND DISTURBING ACTIVITY AND BEFORE INSTALLATION MEASURES. B. AFTER INSTALLATION OF PERMANENT AND TEMPORARY EROSION CONTROL MEASURES, CLEARING AND GRADING. C. AFTER SITE RESTORATION AND INSTALLATION OF PERMANENT EROSION CONTROL GROUND COVER, BUT PRIOR TO FINAL COMPLETION. 5. PER NPDES REQUIREMENTS, A RAIN GAUGE, SELF -INSPECTIONS RECORDS, PERMIT, AND REQUIRED TO BE MAINTAINED ON SITE AND ACCESSIBLE DURING INSPECTION. IT IS RECOMMENDED ITEMS BE PLACED IN A PERMITS BOX AT THE BEGINNING OR ENTRANCE OF PROJECT. 6. ALL EROSION CONTROL DEVICES SHALL CONFORM WITH THE NORTH CAROLINA EROSION CONTROL PLANNING AND DESIGN MANUAL AND GENERAL PERMIT NCG01. 7. THE ESCAPE OF SEDIMENT FROM THE SEWER LINE ALIGNMENT SHALL BE PREVENTED EROSION CONTROL MEASURES AND PRACTICES PRIOR TO CONSTRUCTION. 8. CONTRACTOR SHALL UTILIZE A SILT BAG TO DE -WATER TRENCHES AND PITS DURING 9• CONTRACTOR SHALL USE EROSION CONTROL DEVICES SHOWN AND ANY ADDITIONAL DEVICES CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. 10. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS 11. ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE INSPECTED EVERY SEVEN DAYS RAINFALL EVENT THAT EXCEEDS ONE INCH. DAMAGED OR INEFFECTIVE DEVICES SHALL REPLACED, AS NECESSARY. ALL ESC MEASURES SHALL BE MAINTAINED AS SPECIFIED PLANS. 12. THE CONTRACTOR SHALL CONDUCT SELF -INSPECTIONS OF THE EROSION AND SEDIMENTATION MEASURES AND COMPETE THE FOLLOWING COMBINED SELF -INSPECTION FORM FOUND I TF `, '- LE_, 1 I L LCJ C IC 'C -%2 FI 11 1C '-L- _H 1CL-1 ''1 SHE ;CI1= ":E' ss ss- \\\\������illlluuiiiii,/ \\ ��N CARD ��` �j ." �. �i '% \�` p E.SS/ 4, .-7 �r_ 1 a 0. A _ 026481 // - /" a,0a � '% G� 61101\ F� Q�,�` ��'�9/D0. SASS��`�\ �'�/i�omino\\\\\` �\ SEAL NOT VALID UNLESS SIGNED AND DATED FM FM SEWER FORCE MAIN STORMWATER PIPE Fo Fo- UNDERGROUND FIBER OPTIC LINE x x x x FENCE PROPERTY LINE - - PERMANENT EASEMENT OR R/W H INFRASTRUCTURE ENGINEERING, I G H F I LL P.C. I I STRUCTURE OUTLINE (SHAPES VARY) TEMPORARY BENCH MARK WATER METER ►�� SEWER ABANDONMENT //// LIGHT POLE 0 PROPERTY OR R/W MONUMENT - GUY WIRE 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel919-481-4342 www.hiepc.com Firm License No. C-2586 0 SIGN BORE AND JACK OR RECEIVING PIT I J PIPE CASING T". HI. ,^ TFF11D-IP . %, 1 -Fr IFF'f- ' F F 1I1T' . H- 1. 1 F'-_ H-11_1 11TJ 11_ C. I C --1 1 I TWELVE AT ALL 13. TEMPORARY 14. CONTRACTOR SOONER OR AREAS AID IN BE STABILIZED IMMEDIATELY 15. CONTRACTOR NEEDED, STORAGE 16. THE ANGLE BY VEGETATIVE SLOPES BE PLANTED TO RESTRAIN 17. UPON REMOVE 18. PERMANENT MORE 19. ALONG VEGETATION GRUBBING INSTALLATION MONTHS OF COMPLETE INSPECTION FORMS SHALL BE KEPT ON -SITE AND AVAILABLE TIMES. IT IS RECOMMENDED A COPY BE KEPT IN A PERMITS BOX. STABILIZATION SHALL BE PROVIDED AT THE END OF EACH WORK DAY TO SHALL SEED, FERTILIZE, AND MULCH ALL DISTURBED AREAS WITHIN 14 AS OUTLINED BY NPDES GROUND STABILIZATION TABLE LOCATED ON ED-2.0. WITH A SLOPE GREATER THAN 2:1, ROLLED EROSION CONTROL PRODUCTS SURFACE STABILIZATION. CRITICAL AREAS SUCH AS STEEP SLOPES, WETLANDS IMMEDIATELY UPON COMPLETION OF PIPE INSTALLATION. ADDITIONALLY, STABILIZE GRADING CUT SECTIONS SHOWN ON SS-1.4 UPON COMPETITION SHALL PROVIDE A CONSTRUCTION ENTRANCE AND ADDITIONAL EROSION CONTROL TO BE IMMEDIATELY INSTALLED, FOR ANY MATERIAL LAY DOWN, STAGING AREA, OR ANY OTHER AREAS DISTURBED BY CONSTRUCTION. FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE COVER OR OTHER ADEQUATE EROSION -CONTROL DEVICES OR STRUCTURES. LEFT EXPOSED SHALL, WITHIN 7 OR 14 CALENDAR DAYS OF COMPLETION OF OR OTHERWISE PROVIDED WITH TEMPORARY GROUND COVER, DEVICES OR EROSION. STABILIZATION OF THE CONSTRUCTION CORRIDOR AND APPROVAL BY ENGINEER, AND PROPERLY DISPOSE OF EROSION CONTROL DEVICES. GROUNDCOVER WILL BE PROVIDED FOR ALL DISTURBED AREAS WITHIN 15 THAN 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF STREAM BANKS AND/OR WITHIN 10 FEET OF THE ORDINARY WATER LEVEL FOR MAY BE CUT TO GROUND LEVEL DURING THE CLEARING PHASE OF THE PROJECT; OR SOIL DISTURBANCE SHALL OCCUR WITHIN THE CORRIDOR UNTIL IMMEDIATELY AND THEN ALL WORK SHALL CONTINUE IN THE LOCATION UNTIL COMPLETE FOR INSPECTION DISTURBED AREAS. CALENDAR DAYS, OR FOR ANY CRITICAL AREA SHALL BE UTILIZED TO OR FLOOD AREAS SHALL CONTRACTOR SHALL OF GRADING ACTIVITIES. DEVICES AS EXCAVATED MATERIAL THAT CAN BE RETAINED IN ANY EVENT, ANY PHASE OF GRADING, STRUCTURES SUFFICIENT CONTRACTOR SHALL WORKING DAYS OR NO CONSTRUCTION. LARGE CHANNELS, HOWEVER, NO PRIOR TO PIPE AND RE -STABILIZED. MAILBOX III Engineering isour profession. Service is our passion. TEMPORARY CONSTRUCTION EASEMENT WETLANDS BOUNDARY 3IG 3RANCH SS IMPROVEMENTS RALEIGH WATER RALEIGH, NC GE\ERAL \OTES, LEGE\D, A\D ABBREVIATIO\S + 4 SUBSURFACE TEST BORE X ITEM TO BE REMOVED ASPHALT/CONCRETE REMOVAL & RESTORATION ////� LOD LOD LIMITS OF DISTURBANCE LINE CRZ CRZ CRITICAL ROOT ZONE - TCA TCA TREE CONSERVATION AREA LINE - 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS, DETAILS & SPECIFICATIONS (REFERENCE: CORPUD HANDBOOK, CURRENT EDITION). 2. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY RALEIGH WATER PRIOR TO CONSTRUCTION. 3. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO RALEIGH WATER. 4. INSTALL 4" PVC SEWER SERVICES © 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE & SPACED EVERY 75 LINEAR FEET MAXIMUM. 5. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 6. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. 7. WATER AND SEWER WORK IN STREETS SHALL BE BACKFILLED, TOPPED WITH GRAVEL, AND COMPACTED DAILY AS WORK PROGRESSES TO CONTROL EROSION. EROSION CONTROL MEASURES SHALL BE USED AT CURB INLETS TO PREVENT RUNOFF FROM ENTERING THE STORM SEWER SYSTEM WHERE NEEDED. 8. ANY STORM DRAIN PIPE DAMAGED DURING THE INSTALLATION OF NEW SEWER AND/OR WATER LINES SHALL BE REPAIRED WITH A MINIMUM OF 10' OF REPLACEMENT PIPE OF THE SAME MATERIAL AS THE PIPE DAMAGED. ALL DAMAGED PIPE SHALL BE REPLACED. O PERMIT/RECORD BOX LOCATION CONCRETE WASHOUT SF- SF SILT FENCE TP- TP TREE PROTECTION FENCE sF/TP- sF/TP- COMBINATION SILT FENCE & TREE PROTECTION FENCE - _ SILT FENCE OUTLET PIPE INLET PROTECTION ' CHECK DAM CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION II INLET PROTECTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit an p p p y violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: City of Raleigh Development Approval ( WATTLE EROSION CONTROL MATTING i TEMPORARY CONSTRUCTION ENTRANCE ---•-�-1 •••••••••1 RIP -RAP BANK STABILIZATION W. A.° �r �� �� STREAM STABILIZATION PROJECT NO. RAL1 8O 1 1//j/�� 0 CC m CO m CP-6- N:7575 E:210967 EL:236.30' h i • ' BAR SET I 54417.92' 2109322.8 s' EL:225.¢4' CP-7-NAIL SET 757280.10' E: 10402.31' 25 1' CP-8-MAG SET N:756999.77' 110839.91' E�:2 97' $N. E:211 EL:195.49 AIL SET N:7 2476.10' $ E:2110508.55' EL:198.51' r"-1 GRAVETY SEWER SERIES 1 440 NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS pN 1!**141ti '3iP� o� o ,a11 �O COMPT ON RD O*ft CP 21-Ma2Nail Set N:710783.25' E: 10783.98' ** EL:268.66' 1 • : • • ITH ON:76150:.11 E:2110992. EL:250.90' I , ST. $N:762492.84' 4' I la 83.55' it#4rST 1 P-14-Nail Set :2110598.61' EL:272.79' aim CP 11-MAG/SET $ N: 62488.82' E:2110522.09' EL:'59.17' 109900. RINCR )1 64,111,1m, a ri E. MILLBROOK RD EL 312.80' nian EN: 2: 71E6151: :1 66:972P ..::516316.: GRAVITY SEWER SERIES 2 SCALE: 1" = 200' KINGWOOD DR (-3GRAVITY SEWER SERIES 3 CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN z 0 w CC N 0 0 N 0 0 N \ 0 0 0 N 0 r7 0 w 0 *�1 � pESS/ r 'Lq�'�• W>s = 026481 / - ,/;/, P O SASS\\ \ SEAL NOT VALID UNLESS SIGNED AND DATED HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service is our passion. (f) Li] Li] 0 (f) UD ny m 0 m RALEIGH WATER RALEIGH, NC LOCATIO\S 7 0 0 CO\TOL 0 ›- Li Li %D PROJECT NO. SAL 1801 SCALE: 1" = 400' SCALE: 1" = 300' SCALE: = 300' City of Raleigh Development Approval C - 0 . 1 m EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON PLANS. SEE 31-06/ED-1.0 & 1 /ED-4.0. 4. SHEET SS-1.0 DISTURBED AREA: 37,240 SQ. FT. PIN 1705933559 CCC CALIBRE CHASE LLC DB: 15704 PG: 929 BM: 1988 PG: 346 qAp R to�� \R 8, \q 1 6, 0 PIN 1715023641 \ \ F�- SEVEN PROPERTIES BDM, LLC JAD PROPERTY, LLC DB: 16656 PG: 1849 \ SS NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 8. EASEMENT CLEARING: • CLEAR FULL WIDTH OF 40' PROPOSED EASEMENT ON THIS SHEET. 220 INSTALL CONSTRUCTION ENTRANCE OFF PARKING LOT (SEE DETAIL SW-20.09/ED-1.0) EX. EASEMENT UNES EX. BUILDING EX. SMH170086 EX. 20' E�SEME RIP RAP INV=199.36' 2' 4 4 8" SS EX. PARKING LOT CURB AND GUTTER REPAIR, SEE DETAIL T-10.26.1/TD-1.0 PERMIT/RECORD BOX LOCATION PIN 1705933559 CCC CALIBRE CHASE LLC DB: 15704 PG: 929 BM: 1988 PG: 346 AREA BETWEEN PARKING LOT AND EX. SMH170086 CAN BE USED AS STAGING AREA TEMPORARY SILT FENCE/TREE PROTECTION, TYP. (SEE DETAIL TPP-08/ED-2.0) AERIAL CROSSING EX. 30' PERMANENT EASEMENT /--Luz 777 PROPOSED 40' PERMANENT EASEMENT (20' FROM CL OF SS) BZ 725 TEMPORARY SILT FENCE, TYP. 2.79 (SEE DETAIL SW-20.01/ED-1.0) 192.40 8" (E, I BUT: 194.20 8" (NW) SMH2 PIN 1715033465 350 SIX FORKS LLC DB: 14194 PG: 2713 BM: 1989 PG: 1475 EX. BUILDING REPLACE IN PLACE EX. 18" SEWER WITH 30" SEWER (TYP.) CONNECT TO EX. MANHOLE INSTALL VIA OPEN -CUT. CLOSE APARTMENT ENTRANCE DURING CONSTRUCTION IN ROAD. ONCE ENTRANCE IS CLOSED, CONTRACTOR SHALL BEGIN CONSTRUCTION AND CONTINUE UNTIL ENTRANCE ROAD CROSSING IS COMPLETE AND TRENCH IS BACKFILLED (OR ROAD PLATES INSTALLED. CONTRACTOR SHALL PLAN ROAD CROSSING TO MINIMIZE TIME ENTRANCE IS CLOSED. APARTMENT TRAFFIC SHALL BE DETOURED TO APARTMENT ENTRANCE ON ANDERSON DRIVE. CONTRACTOR SHALL COORDINATE W/ APARTMENT STAFF TO NOTIFY RESIDENTS MIN. OF 1 WEEK BEFORE ROAD CROSSING. SEE 1/TD-1.0. EC MATTING (SEE DETAIL 31-06/ED-1.0) STABILIZE WITHIN 7 DAYS. (-1-PLAN - STA. 12+77 TO 17+00 SCALE: 1" = 40' SMH114369 RIM:21 1.40 INV OUT: 202.40 12" (SE) EC MATTING (SEE DETAIL 31-06/ED-1.0) STABILIZE WITHIN 7 DAYS. EX. 12" SS ys V ys SMH3 CONCRETE RETAINING WALL COMPETE HEADWALL 1 x9' BOX CULVERTS INV=193.25' BIq BRANCH 220 215 o .z z z VENT ELEV. `no no 217.3' to o In SMH170086 ,. 10+00.100 :208.00 I O 0 -et > - 0 210 rnrn� .- > ZZ`.'U 210 ENTRAN z �O ��%U a a MW z z 0 _ o o M In 2 c3 INSTALL VENT (SEE CNI M 0 w N� >>> g z z z o No . ro co i 100-YR FLOOD o r) o w DETAIL S-24 D-2.0) 41N 0 0 a0 Q 9 u_ �N cs. CD ri °- CD rn � T PLAIN ELEVATION g on Q - ' STA. 15+01 RIM:204. 5 INV I: 9 INV I: 9 II •= 205 \ t 0)ON r= 205 re �fu7 rn z z W o I JIVII IL - STA. 12+ RIM:2C3.0 INV IN: 1 IAR/ ',Ill - •0 1 mcnEzz )w 1- .3 z c 7 < �� �\ 200 200 EX. SURFACE GRADE I r / _ / / 195 195 / ALIGNMENT FROM EX. SMH170086 TO SMH 2 HAS BEEN INSTALLED, NOT INCLUDED IN CONTRACT / :EWER REPLACE IN PLACE WITH 30" EX. 18" SEWER (TYP.) .� / / l � 190 190 , 254.13' 30" C900 DR32.5 PVC ® 0.08% - REPLACE EX. MANHOLES 254.86' 30" C90C DR32.5 PVC G 0.087% 185 185 • • ' C 0 0.08% ALONG ALIGNMENT, U.N.O. 180 180 CON CUR Gt� ads 38 FW FES 18" RCP INV. IN=198.07' FES 18" RCP INV. OUT=197.01' 338 338 33 CALIBRE CHASE DR. ASPHALT DRIVE REPAIR (SEE /DETAIL S-3/SD-1.0) u7 m cr) � 2�3 rn ,D7c� AAMM PIN 1705933559 CCC CALIBRE CHASE LLC DB: 15704 PG: 929 BM: 1988 PG: 346 CONCRETE HEADWALL 14'x ULVERTS INV. IN=191.40' CONTRACTOR SHALL REMOVE AND STORE SHRUBS DURING CONSTRUCTION AND REPLACE ONCE CONSTRUCTION IS COMPLETE. SHRUBS THAT DO NOT RETAKE AFTER PLANTING SHALL BE REPLACED BY CONTRACTOR. GRAPHIC SCALE 40 0 20 40 80 160 ( IN FEET ) 1 inch = 40 ft. Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: City of Raleigh Development Approval REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN z 0 0) w N 0 0 N 0 0 N 0 0 0 N 0 O w 0 HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service is our passion. (f) LLJ LLJ 0 n up (f) Z 0 ny m 0 m RALEIGH WATER z 0 O W LL_ 0 rr 0 0 i 7 0 9+50 10+00 11+00 12+00 13+00 14+00 2 PROFILE - STA. 12+77 TO 17+00 SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 15+00 16+00 17+00 PROJECT NO. SAL 1801 SS-1.0 CC CONTRACTOR SHALL PROVIDE TEMPORARY FENCING FOR DOG PARK DURING CONSTRUCTION ACTIVITIES TEMPORARY CONSTRUCTIO EASEMENT LX. UUU HANK - EQUIPMENT EX. IRRIGATION CONTROL VALVE POWER POLE, CONTRACTOR T SUPPORT OR MOVE TEMPORARILY DURING CONSTRUCTION (TYP.) BORE PIT (10'X30') NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 8. EASEMENT CLEARING: • CLEAR AS NEEDED FOR CONSTRUCTION ON THIS SHEET. SEWER ABANDONMENT 1. PLUG NORTH INVERT IN OF MANHOLE SMH158291. 2. ABANDON EX. MANHOLE SMH117597 (SEE DETAIL 1 /MD-2.0) AND REPAIR PAVEMENT. 3. ABANDON EX. 18" SS FROM SMH158291 TO TOE OF SLOPE. FILL WITH FLOWABLE FILL. 4. REMOVE EX. 18" SS AS REQUIRED FOR CONSTRUCTION. PLUG PIPE END WITH MINIMUM 2' CONCRETE PLUG. BORE AND JACK CASING NOTES: 1. FILL ANNULAR SPACE BETWEEN CASING AND CARRIER PIPE WITH FLOWABLE FILL. FLOWABLE FILL SHALL BE INSTALLED IN MAXIMUM 18" LIFTS AS MEASURED FROM INVERT OF CARRIER PIPE. ALLOW A MINIMUM 8 HOURS OF CURE TIME PER LIFT. 2. CONTRACTOR SHALL FILL ENTIRE CARRIER PIPE WITH WATER TO PREVENT FLOTATION DURING FLOWABLE FILL INSTALLATION. 225 i 1 iv "v4s 5 STEAM VENT - TOP=214.94' BO OM=210.37' STEAM TOP=215. BOTTOM=21 1. - 339 EMOVE EX. FENCE AS NEEDED STEAM MH FOR CONSTRUCTION. CONTRACTOR TOP=215.51 ' SHALL REINSTALL FENCE AFTER BOTTOM=211.88' CONSTRUCTION IS COMPLETE. STEAM VEN ''9 FOP =2-4-43 4' BOT/T01=210.43' co FES 1 " RCP INV. OUT L 10.22' RIP RAP EX. FENCE GATE DOG EXERCISE AREA TEMPORARY CONSTRUCTION EASEMENT DUMPSTER - METAL STUB PIN 1705933559 COVERED BY RAMP CCC CALIBRE CHASE LLC METAL POST DB: 15704 PG: 929 GAS STUB BM: 1988 PG: 346 BRICK WALL BRICK FENCE RETAINING FENCE - / 130 LF BORE AND JOL1< UNDER DRIVEWAY RIP RAP 209- -208 ANO • ♦` TEMPORARY SILT FENCE/TREE PROTECTION, - TYP. (SEE DETAIL TPP-08/ED-2.0) 0 STE; MH 3i8 339 TOP=215.60' BOTTOM=210.35' 18" RCP INV. 338 STORM MH TOP=216.13' OUT=208.34' RCP INV. IN=210.37' PIN 1705944082 CCC ANDERSON FLATS LLC BLOCK WALL DB: 17034 PG: 1553 BM: 2015 PG: 1814 1/MD-)1 0 N:754 3.943 E:2109601.93i 0© oo 00 .., • I I I / TEMPORARY SILT FENCE OUTLET, (SEE DETAIL SW-20.24/ED-1.0) 0 0 LITTER 00(1,0 � STATI O N AT&T ACCESS T&T B iTA ON. •b R��PAI0-RCN, 0 o GhAVPL U PIN- 10594 AC WATKINS & IV DB: 12973/P� BM: 1c 4 't OTENTIALLY CONTAMINATED SOILS BOUNDARY. CONTRACTOR SHALL TEST SOIL FOR PETROLEUM CONTAMINANTS. TAKE 2 TESTS AT SMH4 AND SMH5- 5� o o 1_EaT-EX1 - 197.14' . _ - SS TO NEW MH MH4 _C7' DIAa• I 9'xc �-- - -F1754011.9366 - E:2109781.5185 CONCRETE HEADWALL 9'x9' BOX CULVERT INV. OUT=191.53' CON ' HEADWALL 14'x9' BOX CULVERTS INV. IN=191. EC MATTING (SEE DETAIL 31-6/ED-1.0). STABILIZE WITHIN 7 DAYS. FW PIN F17059 ,,3559 Fw CCC CALIBRE CHASE LL DB: 15704 PG: 929 BM: 1988 PG: 346 SM 100622 RIM:206.80 INV IN: 194.36 18" (N) INV IN: 199.1 10" (NW) SMH158291 INV OUT: 19 10 18" (S) RIM:207.00 INV IN• 194.50 18" (N) (PLUG) INV OUT: 194.30 18" (S) Fw 1 338 338 Oo /= / p ck\ - CURB I 4y 0 I TOP= 338 TYP/ O 09.61' 24" RCP G' C' OUT=205.80' SMH1127471 RIM:215.72 INV IN: 207.40 10" (NW) INV OUT: 207.30 10" (SE) PIN 1705946355 HERBERT & ELIZABETH STEWART CONSTRUCTION ENTRANCE TYP. BM 1 : 1987 PG: 519 BM150 (SEE DETAIL SW-20.09/ED-1.0) oi -4 / I / ps t. D JAC9K" UNDER ROAD. , SPCE TO, BE FILLED iFLQWABLE FILL. SEE 0/ AND JACK CASING /�j ti L 2 Fw - -SMH117597 RIM:206.60 INV IN: 194.50 18" (N) INV OUT: 194.30 18" (S) 4, �� = I IN / O PIN 1705946466 ROBERT & JANE HUBAND DB: 16878 PG: 566 BM: 1987 PG: 150 TEMPORARY CONSTRUCTION EASEMENT (15'x65') WOOD DECK !�` • l�- 4 CURB INLET TOP=206.83' 24" RCP INV. IN=202.25' 24" RCP INV. OUT=199.37' 24" RCP INV. OUT=193.75' CONCRETE HEADWALL 9'x9' BOX CULVERTS FW -I f5 V - 171 F 0 FW CP-3-REBAR/CAP SET N:754237.34' E:2109832.38' EL:206.96' FW SEE EROSION CONTROL NOBS FOR BORE AND CI( SPOIL AREA. rt BTH&USE IRRIGATION �z PIPE REPLACE IN PLACE EX. 18" SEWER WITH 30" SEWER (TYP.) FW F✓ FW PIN 1705948496 SIX FORKS COMMONS OFFICE CONDO DB: 4043 PG: 386 FW SEE SEWER ABANDONMENT PLAN 1 NOTES 1,2, & 3 I 1 4" CPP INV. OUT=198.49' PROPO EASE BIRu.... _ __ ROdK WALL BIG BRANCH FW FW EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON / PLANS. SEE 31-06/ED-1.0 & 1 /ED-4.0. 4. SHEET SS-1.1 DISTURBED AREA: 36,725 SQ. FT. AND (50' SNDR / PIN 1705947505 ROBERT & ELIZABETH SCOTT DB: 9307 PG: 981 BM: 1987 PG: 150 ED 40' PERMANENT NT (20' FROM CL OF SS) PLANT ss ss SMH111368 RIM:207.20 I\1NV-1-N: 197.50 1 S" (N) INV IN: 19 e 0" (S) INV OUT: 196.80 10 (SE) ss / / / / I / 4' / /�c�/ / PIN 1705947626 BASKETBALL A:(,) �� / DB: 1A4175 PG:C 2337 E T GOAL /,� _�/ . / BM: 1987 PG: 150 ROCK ( t ,,, # f eiso. i ii,„,- , , _.._ WALL BRICK PLANTER L WALL '' 9 ROCK STEPS. INSTALL CASING VI ► OPEN -CUT FW EX. 40' PERMANENT EASEMENT - STA. 17+00 TO 28+00 SCALE: 1" = 40' TEMPORARY SILT FENCE, (SEE DETAIL SW-20.01 /ED-1.0 CP-4-NAIL SL I Fw >N:754537.1 1 ' E:2109866.09' EL:208.51' €pz 80 BIR.QHOUSE BENCH W BIRD FEEDER Fw BIRD BATH GRAPHIC SCALE 40 0 20 40 80 ( IN FEET ) 1 inch = 40 ft. ss Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature 40 TONS OF CLASS 1 RIP -RAP, 2' DEEP FOR DITCH STABILIZATION. INSTALL RIP -RAP SUCH THAT TOP OF RIP -RAP MATCHES PRE -CONSTRUCTION DITCH BED ELEVATION AND BANK ELEVATIONS CONTOURS. PIN 1705947757 CALVIN MCPHAIL & HELEN W KIRVEN DB: 5567 PG: 574 BM: 1987 PG: 150 PLAY EQUIPMENT WOOD DECK -1 ROCK PATH ROCK P 160 / PIN 1705947876 / LINDSEY & MATTHEW RAINES DB: 16949 PG: 1980 BM: 1987 PG: 150 CONC DRIVEWAY GATE BRICK WALL STONE STEPS GATE BRICK WALL DI (3) TOP=203.66' BIRD FEED INV. OUT=202.48' BIRDHOUSE 225 220 215 o 0 210 100-YR FLOOD 0 n ‘- " 0 i ziic 205 PLAIN ELEVATION re) 0 g PI In NI VENT ELEV. 217.3' INSTALL VENT (SEE DETAIL S-24/SD-2.0) 0 200 SEWER LINE WITHIN CONTAMINATED SOIL BOUNDARY APPROXIMATELY FROM STA 17+08 TO 21+38 195 190 185 EX. 18" RCP STORM PIPE INV. 202.1 130 LF 193.46' 30* C900 DR3t5 BORE AND JACK W/42* STEEL CASING NIN. WALL THICKNESS 0.6251 AND 30 RJ CARRIER PIPE VIA FU^IBLE 7- CC- GRADE csj 220 o a) Lai 215 210 EX. 10" SS P INV. 201 77 125 LF BORE ANC JACK W/42* SlEEL CASING (MIN. WAU_ THICKNESS 0.6251 AND EX. 24" R STORM PIPE IF CDNTAMINATED SOI _S ARE PRESENT, EXTEND DR32.5 FUSIBLE PVC A MIN. OF 20 LF BEYOND CONTAMIlsATION. EX. 4'' STORM PIPE y‘.7304`9002.5 PiC 0 0 / / / EX. 6" STORM PIPE INV. 202.93 205 200 REPLACE EX. MANHOLES ALONG ALIGNMENT, U.N.O. THICKNESS 0.501 AND 30* RJ CARRIER PIPE VIA FUSIBLE OR RJ FVC. EXTEND RJ PIPE A kAlN. 10 LF OUTSIDE CASING. (SEE DETAIL S-39/SD-3.0) E IN SEWER WITH PLACE EX. 18" 195 190 CONTRACTOR SHALL INSTALL ANTI-F MEASURES FOR PIPE NSTALLED WITH 4-FT OF COVER. APP OX. 415 LF BET 22+00 TO 26+15, SEE DETAIL 2/ TATI 0 N ESS THAN EEN STA. 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 (2-PROFILE - STA. 17+00 TO 28+00 25+00 26+00 CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: -D co REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN 0 0 0 0 0 0 0 co Ld o HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service Is our passion. (f) 0 UD (f) 0 RALEIGH WATER RALEIGH, NC oo c 0 nv 7 PROJECT NO. 801 SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS City of Raleigh Development Approval CC m IRON RAIL FENCE 27+50 �BZ PIN 1705949886 BARNARD, MAGAN BARNARD, GRAYSON DB: 16901 PG: 2017 BM: 1992 PG: 354 3FE 80 FW FW - FW BFE BFE BFE FW\ BFE BFE PIN 1705948915 PEYTON ANDERSON DB: 9285 PG: 1616 BM: 1987 PG: 150 EX. 4" SS ALL GOAL CONC PAD 203- - BZ FW 4S � FW FW SMH9 EX. 40' PERMANEASEMENT _ �1 FW FW 1 SEE SEWER ABANDONMENT NOTES BFE BFE PIN 1705958008 CAROLINE PLUMMER DB: 16078 PG: 2399 BM: 1987 PG: 150 BRICK WALL N FIN 1705949978 -BR0 ES, DAVID ROBERT BROYLES; G4RRETT YOUNG DB: 17461 G: 310 BM: 1997 IDGni, 736 gFE BFE D. E-\ RR �W) �50 EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON PLANS. SEE 31-06/ED-1.0 & 1 /ED-4.0. 4. SHEET SS-1.2 DISTURBED AREA: 40,088 SQ. FT. 225 gFE GRAPHIC SCALE 40 0 20 40 80 WOOD PICK GATE H'10 :755073.4020 :2109917.1267 i FENCE 7 160 ( IN FEET ) 1 inch = 40 ft. TEMPORARY SILT FENCE OUTLET, TYP. (SEE DETAIL SW-20.24/ED-1.0) PIN 1705959107 JOSEPH DUNCAN DB: 12491 PG: 855 BM: 1987 PG: 150 INSTALL 30" SS \\N \ o AERIAL PIPE ,,,CROSSING BFE Fw \ \ Fw ss 2 BFF ss iv • BF \g' 42 TONS OF CLASS 1 RIP -RAP, 2' DEEP FOR DITCH STABILIZATION. INSTALL RIP -RAP SUCH THAT TOP OF RIP -RAP MATCHES PRE -CONSTRUCTION DITCH BED ELEVATION AND BANK ELEVATIONS CONTOURS. INSTALL CASING VIA OPEN CUT PROPOSED 40' PERMANENT - EASEMENT (20' FROM CL OF SS) VIIV 1 / I DU3ULf 0 EX. EASEMENT LINES, HARRY DEHART & ELIZABETH DEHAF DB: 16952 PG: 2225 BM: 1964 PG: 159 REPLACE IN PLACE EX. 18" SEWER WITH 30" SEWER / o '• �\ s CONTRACTOR • STAGING AREA CURB AND GUTTER REPA SEE DETAIL T-10.26-.-.1/TD-1 CURB INLET FILTER SACK, TYP., SEE DETAIL 31-15A/ED-2.0 CURB INLET TOP=207.13' 15" RCP INV. IN=203.63' 15" RCP INV. OUT=203.62' CURB INLET TOP=207.06' 15" RCP INV. IN=203.63' 15" RCP INV- OUT=203.53' SMH12 MP.) Fw EX. 4" SS FW FW 0 FW N✓ - �BZ 197 1 i4786 Fw _ FW Fief 05.10 INV IN: 198.20 10" (SW) INV OUT: 198.00 10" (NW) FW �W FW � 0 �• BIC FW BRANCH FW CONCRETE WASHOUT, SEE - DETAIL SW-20.25/ED-1.0 0 Z �0����1_=��� FXd� TEMPORARY SILT FENCE, TYP.---1 - (SEE DETAIL SW-20.01/ED-1.0) FW CURB INLET TOP=210.13' 15" RCP INV. OUT=205 2 31" TREE - 24" TREE F`N 15" RCP INV. OUT=203.1 1' PIN 1715052514 ANDREW & AMANDA TATTERSALL DB: 16869 PG: 89 BM: 1999 PG: 603 PIN 1705959751 CITY OF RALEIGH DB: 8475 PG: 901 BM: 1968 PG: 54 SEE NOTE 9 Ja0 Zj3 7 Zao 1 1 " THE 2�J 27"\FREE 'c, 38"\,,TREE ift / H14 </ CP II . I1V= f .9�'` DETAIL O/SD-2.0) RC-P119! 0 293.93' GS1ARDRA� ,70 / • ,-: DIVE REPAIR / AILS 3/SD / 7 1 1 RIP -RAP, 2/DEEP / FOR STORM/IPE • UT. INSTALL RIP -RAP SUCH THAT TOP 0 RIP -RAP MATCHES PRE-CONSTRUC$ N ITCH BED ELEVATION AND BANK E TIQNS CONTOURS. / / , / Im / J / / BFE / / / gFE PLAN - STA. 28+00 TO STA. 38+00 SCALE: 1" = 40' 7 eF SMH15 N:755822.1346 E:2109953.8 225 220 215 210 net „t 205 200 195 190 N cq 10 6- ON 0 ftE INSTALL -VENT (SEE -\ 7 j- EX. SURFACE GRADE 7 a at 0 co to 7 100-YR FLOOD PLAIN ELEVATION 1- el- cog 000 00)00 185 7 -7 • rREPLACE IN SEWER WITH 220 215 210 • LACE EX. MANHOLES ALONG ALIGNMENT, U N.O. EXTEND RJ E TO MH STEEL CASING (MIN. WALL THICKNESS 0.50-) AND 30- RJ CARRIER PIPE VIA FUSIBLZ-OR-RTEND-RJ-- PIPE A MIN. 10 LF OUTSIDE CASING. (SEE DETAIL 3=39/SD-T.-a EX. 15" RCP INV. 203.76 CP PIPE 3.35 EX. STO INV. 12" RCP M PIPE 204.19 ( 0.08% 205 200 195 190 NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 8. ALL TREES LOCATED ON CITY OF RALEIGH PROPERTY WITHIN THE LIMITS OF DISTURBANCE SHALL BE REMOVED. 9. EX. 30" TREE LOCATED OUTSIDE THE EASEMENT BUT ON CITY OF RALEIGH PROPERTY SHALL BE REMOVED. REMOVE STUMP AND FILL WITH SOIL AND SEED. 10. EASEMENT CLEARING: • CLEAR AS NEEDED FOR CONSTRUCTION ON THIS SHEET. 7 /NEW SS SHEET SS-1.8 SEWER ABANDONMENT 1. REMOVE EX. 18" SS AS REQUIRED FOR CONSTRUCTION. PLUG PIPE END WITH MINIMUM 2' CONCRETE PLUG. STREAM CROSSING NOTES: 1. FOR ALL STREAM CROSSINGS, CONTRACTOR SHALL UTILIZE DAMS AND PUMPING AS NECESSARY TO PREVENT DOWNSTREAM SEDIMENT TRANSPORT (SEE 3/ED-2.0). 2. WHERE EQUIPMENT CROSSING WILL OCCUR CONTRACTOR SHALL INSTALL TEMPORARY STREAM CROSSING (SEE 3. UPON FINAL COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL INSTALL PERMANENT STREAM STABILIZATION (SEE Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 (-2- PROFILE - STA. 28+00 TO STA. 38+00 36+00 37+00 CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN 0 (.0 0 0 0 0 0 0 o HIGHFILL INFRASTRUCTURE ENGINEERING, P. C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 Firm License No. C-2586 Engineering is our profession. Service Is our passion. (f) 0 ry UD (f) nv RALEIGH WATER RALEIGH, NC oo 0 0 0 00 CN 0 nv 7 PROJECT NO. SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS City of Raleigh Development Approval CC 801 Y�.;_-.alb �so \` / Fes- BFE FW FW / FW / 210 BFE ��� N /// SSA ro / / /g� ..i. F SMH1 9049 RIM:. 18.20 INV IN: 208.50 10" (W) INV/ OUT: 208.30 10" (E) PIN 1705957637 BETH & BRANDY SCHROEDER 1 STORY WOOD DB: 14388 PG: 893 FRAM BUILDING FES 24Y' CPP INV. OUT=\08.85' 24" CPP I IN=209.33' PIN 1705958648 JAMES & DONNA TAYLOR DB: 3840 PG: 759 BM: 1968 PG: 54 N OPOSED PERMANENT EASEMENT 20' FROM EX. EASEMENT BETWEEN SMH119890 AND SMH154821 TEMPORARY SILT FENCE, TYP. (SEE DETAIL SW-20.0 ED-1.0) 30 'EE OA" TREE PIN 1705959751 32" TREE CITY OF RALEIGH SEE NOTE 9 D 8475 PG: 901 .1968 PG: 54 ▪ o- -/ co REPAIR CONC DRIVE (SEE D i L S-2/SD-1.0 /BASKETBALL bUAL ROCK WOOD FENCE PATEL, DB: 018381 Bz 0 FIREPLACE SEE NOTE 12 SEE S' ABANDONME TE 2 FRENCH DRAIN AND WATERLINE LOCATED ON PROPERTY WITHIN EASEMENT. AVOIDDAMAGE AND RETURN TO PRE -CONSTRUCTION CONDITION A TER PIPE INSTALLATION PIN 17059568. �PJN 1705956838 \ BEAM, ANDREW S / 0 & CELIA HOLLER DB: 17239 PG: 776 BM: 1982 PG: 519 / / B • 1982 PG: 519 } SMH16 //-wE Y r � o N ib CPP INV.��L06.76'� WOVEN // IRE 6cfr---7777.---- BOO- 150 1705959815 Y & LAURA LON 17130 PG: 1879 : 1968 PG: 54 IRON FENC �--E - RIGATION VALVE -GAT-E GAS ,,LAMP EX. 20' PERMANENT EASEMENT SMH15 N:755822.1346 E:2109953.8134 'SEE SEWER ABANDONMENT eat STREAM CROSSING NOTES: 1. FOR ALL STREAM CROSSINGS, CONTRACTOR SHALL UTILIZE DAMS AND PUMPING AS NECESSARY TO PREVENT DOWNSTREAM SEDIMENT TRANSPORT (SEE 3/ED-2.0). 2. WHERE EQUIPMENT CROSSING WILL OCCUR CONTRACTOR SHALL INSTALL TEMPORARY STREAM CROSSING (SEE 1 /ED-2.0). 3. UPON FINAL COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL INSTALL PERMANENT STREAM STABILIZATION (SEE 2/ED-2.0). =e01 mf ^ rsBol 230 2C4)-_* 9890 5--/�.� 2.10 of STA. 38+72.50 UNKNOWN INV. NCE OUTLET, TYP. SW-20.24/ED-1.0) COMPOST BIN DECK - WATTLE, TYP. (SEE DETAIL SW-20.23/ED-1.0) ROCK CHECK DAM, TYP. (SEE DETAIL SW-20.08/ED-1.0) 14 CNN INV. I 2Ub.4U D P INLET (�B 17130 PG 89 TOP 210 INV IN(S)= 05 INV IN(W)= 6 FW FW --- VFw0UT=205 PIN 1705958963 FLINN, DOUGLAS STUDEBAKER, MANDY L DB: 14932 PG: 712 BM: 2004 PG: 1237 SEWER ABANDONMENT 1. REMOVE EX. MANHOLE SMH119890. 2. REMOVE EX. 18" SS AS REQUIRED FOR CONSTRUCTION. PLUG PIPE END WITH MINIMUM 2' CONCRETE PLUG. SMH17 60 PIN 1705956917 FOR STR BFROBERT & LIZANNE MCDONOUGF SUCH E DB: 16357 PG: 1150 PRE-CONSTRU BM: 1982 PG: 1 135 AND STREAM BA EXISTING RIP - FW .35 FW _ FW - FW \ .35' PIN 1705968004 RUNKEN, MICHAEL CHRIS DB: 12945 PG: 328 h BM: 2004 PG: 1237 -215- \ PIN 1705966035 PROPOSED 40' /DENISE & RICHARD FERGUSON PERMANENT gASEM DB: 3077 PG: 338 g'° (20' FROM CI: -OF 58)-- BFE BM: 1982 PG: 1 1F35' BFE BFE STREAM 2 IMPACT: ONS OF CLASS 1 RIP -RAP, 2' DEEP STABILIZATION. INSTALL RIP -RAP T TOP OF RIP -RAP MATCHES N STREAM BED ELEVATION ELEVATIONS CONTOURS. P AMY BE UTILIZED. 0 0 EN WIRE FENCE - REPAIR CONCRETE DRIVE CURB INL (SEE DETAIL S-2/SD-1.0) TOP=2 -' INV. I=209.651__ WIRE FENCE IN ALL CASING VIA OPEN -CUT , - WOVEN / PIN iiu5ybbii5 ELIZABETH & RICHARD DB: 14804 PG: 1 BM: 2003 EX. BUILDING SE ,/ SHEET/ S-1.8 7 .9 r"-1 PLAN - STA. 38+00 TO STA. 46+50 SCALE: 1" = 40' [POSSIBLE JUNCTI0► CHESWICK DR. IS A DEAD-END STREET. CONTRACTOR SHALL MAINTAIN ACCESS FOR THRU TRAFFIC, SEE NOTES 10 & 11. 30" RCP INV. IN=210.06' 30" RCP INV. IN=210 GUTTER R .1 R, SEE -1.0 STALL DROP ON EX. SS, (SEE DETAIL WOOD PICKET D41.0) ENCE PIN 1705964363 SUMMERFORD, REBECCA cv SUMMERFORD, MARG`RE DB: 7810 PG: 3 8 1 SMH112134 RIM:213.00 INV IN: 204.08 10" (SW) INV OUT: 205.10 10" (E) \ WOO DBO RAILING 48" CMP INV. HEADWALL GRAPHIC SCALE 40 0 20 40 80 15 OtS Pw 160 IX 1 inch = 40 ft. 230 225 220 0 VENT ELEV. 216.9' 215 INSTALL VENT 210 205 (SEE 2.0) bt 0 re) tAi 100-YR FLO D PLAIN ELEVATION Ingrei ro) gco o osix co 0 It lel ▪ co cc! 0 LIJ LIJ 0 0 0 ct ct NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 225 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 220 215 EX SURFACE GRADE 200 210 REPLACE IN PLACE EK. 18" SEW 195 190 38+00 188.89' 30" C900 DR32.5 PVC 157.10' 30" C900 DR32.5 PVC Ce REPLACE EX. IAANWOI ALONG ALIGNMENT, U.N.O. 39+00 40+00 41+00 42+00 35 LF 42 THICKNE PIPE VIA FUSI 43+00 (2-PROFILE - STA. 38+00 TO STA. 46+50 EL 241.53' / / / 205 CASING (MIN. WALL LE OR RJ PVC. EXTEND 10 LF OUTSIDE CASING. ETAIL S-39/ D-3.0) 44+00 45+00 46+00 200 195 190 46+50 8. ALL TREES LOCATED ON CITY OF RALEIGH PROPERTY WITHIN THE LIMITS OF DISTURBANCE SHALL BE REMOVED. 9. EX. 32'' TREE LOCATED OUTSIDE THE EASEMENT BUT ON CITY OF RALEIGH PROPERTY SHALL BE REMOVED. REMOVE STUMP AND FILLED WITH SOIL AND SEED. 10. CONTRACTOR SHALL MAINTAIN A LANE FOR THRU TRAFFIC. REMOVE AND REPLACE ANY DAMAGED CURB AND DRIVEWAY AS NECESSARY. 11. IF A PORTION OF THE R/W OUTSIDE THE PAVEMENT IS UTILIZED, CONTRACTOR SHALL PLACE LAYER OF ABC STONE WHERE LANE IS INTENDED TO FACILITATE TRAFFIC. 12. CONTRACTOR SHALL MINIMIZE DAMAGE TO EX. PATIO STRUCTURE. SAW CUT STONE WALL IF NEEDED. REMOVE PAVER STONES ASS NEED AND STORE ONSITE. COORDINATE WITH PROPERTY OWNERS IN STORAGE LOCATION ON THE PROPERTY. 13. EASEMENT CLEARING: • CLEAR AS NEEDED FOR CONSTRUCTION ON THIS SHEET. EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON PLANS. SEE 31-06/ED-1.0 & 1/ED-4.0. 4. SHEET SS-1.3 DISTURBED AREA: 37,009 SQ. FT. NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: -D REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN 0 0 0 0 0 0 0 Ld o HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service Is our passion. (f) Lil 0 ry UD (f) nv RALEIGH WATER RALEIGH, NC 0 0 00 0 nv 7 PROJECT NO. VERTICAL SCALE: 1" = 4' City of Raleigh Development Approval CC PIN 1705964363 SUMMERFORD, REBECCA SUMMERFORD, MARGARET DB: 7810 PG: 348 SHED REPLACE IN PLACE EX. 18" SEWER WI 30" SEWER (TYP s SE ---214 gFF 235 UUNC; PIN 1705963575 PGP Barrett LLC 17253 PG: 1193 STREAM 3 IMPACT: 210 TONS OF CLASS 2 RIP -RAP, 2' DEEP FOR STREAM STABILIZATION. INSTALL RIP -RAP SUCH THAT TOP OF RIP -RAP MATCHES PRE -CONSTRUCTION STREAM BED ELEVATION AND STREAM BANK ELEVATIONS CONTOURS. EC MATTING ON SLOPE (SEE DETAIL 31-06/ED-1.0). STABILIZE WITHIN 7 DAYS. A S CHAINK EX. 4" SS SMH9n EX. 4" SS O 00 40 7 EX. 30' PERMANENT EASEMENT CIPP APPROX. 260 LF OF EX. 18" SS. RB INLET //TOP= 5' 0 IOSTALL CASING IA OPEN-CU iriazt H 1,Zs, 45 ,��ff/ RIpi1:21 V_wJ: 206.8 V OUT 20.J6-ice 261 / SMH2 ' N:756519.83 E:210961.8:7917 INSTALL DhOP ON EX. 8" SS, (SEE DETAIL 33-11/MD-1.0) PIN 1705966357 - • STEVEN & JENNY BARAN DB: 13207 PG: 2132 I GRAPHIC SCALE 0 20 40 80 FW FW FW ,. /1 ji 2 �°2 4 : - �•,� j PIN 17059694 TOWNES AT CHES WNERS ASSOCIATION 'FR1 DB: 17328 PG: 2383 BM: 2016 PG: 533 160 ( IN FEET ) 1 inch = 40 ft. / EX. 18" SS FW ZOg�� 3�- N N N N N N SOB - FW SEE EROSION CONTROL NOTES Bz SMH158845 RIM:227.70 Bz :: 205.10 18" (NE) INV IN: 214.70 18" NW) INV OUT: e I 18" (S) Fyy FW FW FW roe - Tip TOB TOB BFE vtlF Fw N NNi NJ N: 6729.204BZ RRE-c' cp COMBINATION SILT FENCE/TREE PROTECTION, TYP. (SEE DETAIL TPP-08/ED-2.0) E --VATTING ON SLOPE (SEE DETAIL 3-06/ED-1.0). STABIUZE WITHIN 7 DA. EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON PLANS. SEE 31-06/ED-1.0 & 1 /ED-4.0. 4. GRADED CUT SLOPES SHALL BE STABIUZED IMMEDIATELY UPON COMPLETION OF GRADING ACTMTIES. 4. SHEET SS-1.4 DISTURBED AREA: 72,235 SQ. FT. PROPOSED 60' PERMANENT EASEMENT (30' FROM CL OF SS) 0" S PROPOSED 20' TEMPORARY CONSTRUCTION EASEMENT CIPP STREAM CROSSING NOTES: 1. FOR ALL STREAM CROSSINGS, CONTRACTOR SHALL UTILIZE DAMS AND PUMPING AS NECESSARY TO PREVENT DOWNSTREAM SEDIMENT TRANSPORT (SEE 3/ED-2.0). 2. WHERE EQUIPMENT CROSSING WILL OCCUR CONTRACTOR SHALL INSTALL TEMPORARY STREAM CROSSING (SEE 1 /ED-2.0). 3. UPON FINAL COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL INSTALL PERMANENT STREAM STABIUZATION (SEE 2/ED-2.0). PROX. 330 LF EX. 1 8" SS. m TEMPORARY SILT FENCE, (SEE DETAIL SW-20.01/ED- ys z e,F TEMP (SEE D 22 e BIG BRANCH PIN 1705978143 BARRETT SQUARE CONDOMINIUMS DB: 3638 PG: 64 ss SS EX. 6" SS SMH1 - Bz2� RIM:235.07 IN: 205.90 18" INV IN: 0,7-0-t" (N) INV IN: 224.10 4" (W) OUT: 205.70 18" (SW) \004 901 Fw \ s01 \ g01 0 ip1 338 -- 3/9 W _ 1 8 ''� FW FW &SILT OUTLET, 4 SW-20.2 �w 1.0) NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 8. EASEMENT CLEARING: • FULL EASEMENT. CIPP APPROX. 245 LF OF EX. 18" SS. ` e\\ep1\ B FF \���0 \ B�� N PIN 1705968769 STEPHENS CENTER INC THE DB: 3633 PG: 823 Fw BZ FW SEE EROSION N CONTRO OTES FW SMH25 N:7/ 4 5 881.7080( I E:2109923./493 1 I I f SFF SF SF EC MATTING ON SLOPE (SEE DETAIL 31-06/ED-1.0). STABILIZE WITHIN 7 DAYS. 1 PLAN - STA. 46+50 TO STA. 57+00 ®2 W/Ti SCALE: 1" = 40' Bz �X. 6" SS SMH149072 RIM:232.50 INV IN: 223.90 6" (NW) _ INV IN: 176.61 18" (NEB IMV-OIJ-T:_ 208.10 BZ 901 - 9011��'8 9o1 33s FW Fw - FW 330 �� FW FW FW EX. 18" SS, SEE SHEET SS-1..5. SMH27 E:2110011.8794 /5s /( /7 // S 26 :75703 139 / � :2110026.5.24,c � fb-- 225 -23 GRADE AT 2:1 SLOPE NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature NATION SILT FENCE/TREE TPP-08/ED-2.0) cn ro 0 235 in to N LO 230 225 z3` ""v O ^ 0, b- ^ CA- v CE N Z^W s 0 0 N I v�v 0 O � O O QO M pOj ap: O M Z^Ov0 • M .-O C� 1 ::_. W 1 + OOA ��O _ _ ^ M G rn Q 4000 IA 00 c0 MIS d NNR Z Z Z OO CIA .1i cV O cb F.. co co 0, O z + * , N 0 (9 co in .. • 1- �NZZZ0W =Q� > > > I ♦1 N N NNZZZO NNE Z 220 215 210 205 200 195 f 7 // i / / J- y / / i REMOVE EX. MANHOLE (7)C1 71 / / 1 KLG-RAD EX. SURFACE GRADE N. c0 Mto �N0) INV 100-YR FLOOD PLAIN ELEVATION W v - z 20 O K) Q �co ON T0) 0 co o rn I+ONE rej LOON -1 N NZ 0 > > Cr) MIX Z z 230 REGRADE 225 REPLACE IN PLACE EX. 18" -\ SEWER WITH 30" SEWER •) 7 / y / REPLACE EX. MANHOLES ALONG AL GNMENT, U.N.O. EX/: -SEWER ALIGNMENT, TYP. / 90.39' 30" C900 DR32.5 PVC 0 0.08% 1 220.20' 30" C900 DR32.5 PVC 0 0.08% 281.38' 30" C900 DR32.5 PVC 0 0.08% 188.28' 30" C900 DR32.5 PVC 55 LF 42 STEEL CASING (MIN. WALL TFIICKNESS 0.50") AND 30" RJ CARRIER PIPE VIA FUSIBLE -OR RJ PVC. EXTEND RJ PIPE A MIN. 10 LF OUTSIDE CASING. (SEE DETAIL S-39/SD-3.0) 68.59' 30" C900 DR32.5 PVC 0 220 215 210 205 200 46+50 47+00 48+00 49+00 50+00 51+00 52+00 53+00 (-2- PROFILE - STA. 46+50 TO STA. 57+00 54+00 55+00 56+00 CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN 0 0 0 0 0 0 0 o • HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service Is our passion. (f) 0 UD (f) 0 RALEIGH WATER RALEIGH, NC Ln 0 CO 0 nv 7 PROJECT NO. SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' City of Raleigh Development Approval EROSION CONTROL NOTES: 1. SOIL STOCKPILED DURING BORE AND JACK OPERATION MAY BE STORED ADJACENT TO BORE PIT. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE EROSION CONTROL MEASURES TO PREVENT ESCAPE OF SEDIMENT. 2. ANY BACKFILL STOCKPILE SHALL BE COVERED AT THE END OF EACH WORK DAY TO PREVENT ESCAPE OF SEDIMENT. 3. EROSION CONTROL MATTING SHALL BE FURNISHED FOR SLOPES GREATER THAN 2:1 OR DITCH SLOPES GREATER THAN 2%, EVEN IF NOT INDICATED ON PLANS. SEE 31-06/ED-1.0 & 1 /ED-4.0. 4. SHEET SS-1.5 DISTURBED AREA: 27,795 SQ. FT. BZ BZ EX. 6" SS SMH149072 RIM:232.50 INV IN: 223.90 6" (NW) INV IN: 176.61 18" INV-GUT: 208.10 (SW) PIN 1705978143 BARRETT SQUARE CONDOMINIUMS DB: 3638 PG: 64 (SW) aoi 339 - .1/9_ Fw FW BZ CP-5-NAIL SET N:757323.40' E:2109829.68' EL:232.46' CONCRET HEADWALL 10'x9' BOX ULVERTS I NV 209,.631j yy-ASSUMED BURIED MH-LOCATION SS S 3e job 3js9 �s� aol - eol 3-18 --- GHAI 801 - 801 3j6 FW FW FW FW FW TEMPORARY SILT FENCE OUTLET, TYP. - (SEE DET�W-20.24/ED-1.0) //// 474 `1 /// �-50 / /moo , FAN_ -'i'tM1�W 7 / / 7s� r / h:75703fp J` .:2110026.5 56 SMH27 N:757106.3319 E:2110011.8794 F - F �2�FF aF Ss, ePF \, Ri.• A 22i T_�/ \\\ , 7/r / BORE AND JACK CASING NOTES: 1. FILL ANNULAR SPACE BETWEEN CASING AND CARRIER PIPE WITH FLOWABLE FILL. FLOWABLE FILL SHALL BE INSTALLED IN MAXIMUM 18" LIFTS AS MEASURED FROM INVERT OF CARRIER PIPE. ALLOW A MINIMUM 8 HOURS OF CURE TIME PER UFT. 2. CONTRACTOR SHALL FILL ENTIRE CARRIER PIPE WITH SEWER INVESTIGATION NOTES: 1. AFTER FLOW IS ON NEW SEWER ALIGNMENT, CONTRACTOR SHALL CCTV SEWER BETWEEN EX. MHS SMH149072 AND SMH152568 AND LOCATE BURIED MANHOLE. START CCTV AT SMH149072 AND PROCEED UPSTREAM. 2. SUBMIT CCTV DATA TO OWNER. 3. OWNER WILL DIRECT CONTRACTOR FOR SEWER REHABILITATION OF MANHOLE AND SEWER. 446' / / 33e FW RIP R / \// , 7-7-77 #°,114/// �205 TONS OF CLASS 2 RIP I ///////v/ RtP- TMATCH ST PRE -CO /// AT16N AND STREAM BAN ////��/// / EXISTING / / FW /7177 ( , TREE CONSERVATION NOTES: 1. KANE ANDREWS ACQUISITION, CONSERVATION AREAS (TCA). 2. LIMITS OF DISTURBANCE ADJACENT TO TREE CONSERVATION AREAS SHALL HAVE TREE PROTECTION FENCE OR COMBINATION SILT FENCE/TREE PROTECTION FENCE. / / I / // / I I / M/ /ry // GUARDRAIL \ CHAIN LINK FENCE \\ \ \ \ \ F„ 1 �2q'0 ss FW SS- ) FW rn^� FW b�V' ss� CHAIN LINK TEMPORARY CONSTRUCTION EASEMENT. RETAIN EX. MH FOR EMERGENCY USE o0 SMH' 152568 VI.1 LT�TIl 2 INV IN: 151(� �2 1NV IN: 5. �j/ "/ �o I NOP 1 0/ Aid INVESTI SEE SEWER ATION NOTES - - - f WA -STREAM-44MPACT• RAP, DEEP FOR STREAM SUCH THAT TOP OF 1 N = RUCTION STREAM BED ELEVATIONS CONTOURS. P-RAP AMY BE UTILIZED. / GUAR9RAIL / 60+ y BORE AND JACK SPACE TO BE FI SEE BORE AND J BFE / LCC PROPERTY CONTAINS TREE N •//, �G g/7// BFE -55 LT FENCE/TREE PROTECTION, TYP. (SEE DETAIL TPP-08/ED-2.0) EX. SMH1)20 277-RfM:221. INV IN: 213.80 10" (S INV IN: 213.40-ID"-(N E FENCE / SEE SEWER _ INV- OM 21-2.90_10" (SW) (-1-PLAN - STA. 57+00 TO STA. 66+00 SCALE: 1" = 40' KANE ABANDONMENT NOTE-1- / ' SMH29 'N:7577701.71 Pci FE PIN 1715082374 ANDREWS ACQUISITION, I LC DB: 171 17 • 62-3 - j SPOIL my -3Z MPORARY CONSTRUCTION �EASEMENT EPtACE Xg30. j,8 - SEWER .wn " EX. 30' PERMANENT EASEMENT TEMPORARY SILT FEN , (SEE DETAIL-SW-20.01/ED-1.0) MBLOCK M�/V WOOD DECK NOTE 2 SMART DISH (PEST CONTROL) METER RACK SMART DISH (2) (PEST CONTROL) METER RACK SATELLITE DISH SATELLITE DISH EX. 10" RCP SMART DISH (PEST CONTROL) PIN 1715170038 AVONDALE RALEIGH, LLC DB: 157521 PG: 801 BM: 2009 PG: 72 TRANSFORMER / BFE BFE BFE - BFE eFF CONC WALK A BFE - BEE - GRAPHIC SCALE 40 0 20 40 80 160 ( IN FEET ) 1 inch = 40 ft. vvru LR Iv rRGV L.III I-LA/IMIRill VVR117V I-Lvtt/1CILL FILL INSTALLATION. ow 240 0 + o - L + o 240 1Q I _ 1 - 1-• v, w 00-YR FLOOD 'LAIN ELEVATION VENT ELEV. 235 INSTAL! VENT (SFE 235 DETAIL S-24/SD-2.0) Q: 5 > Wp �I 230 z z"a U �> Z �V 230 0 a in •Zf ^ ^� �. O : 0 •� M W v� O 4 o _ M co v ss: EX. SMH52568 ") O M n co 00,� x s M 0 0 W oM Nq COONO N N gyp• ? ONIA p II M 00 � 0000 p � �cNOCC p CD `v ~ 225 NN -0 � � in 1, a0o, 0 c rn�o N 5 � 1 OtBlyc � io N 0 L 225 = (Ni u7 r+ C0ryl00 N, C9 _ Qom_ 2 N 0 cnv�i� 3 � � o Q N`G° ±" Z Z � cn�n2 _ _ 3 � 3 / O� / Q zw 1_ co co moo: - - - 3 EX. SURFACE GRADE 220 - 220 - / �- 215 -� / 215 / REPLACE IN PLACE EX. SEWER WITH 30" 18 SEWER / / CrYP.) / 7 Alv / / 210 _/ 210 405 LF BORE AND JACK W/48" STEEL CASING (MIN. WALL THICKNESS 0.75") AND 30" PVC RJ 459.09' 30" C900 DR32.5 FUSIBLE PVC 0 0.50% CARRIER PIPE VIA FUSIBLE OR RJ PVC. (SEE DETAIL 33-22 & 33-23/MD-1.0) PVC O 0.94% --������� ' 30" C9O0 DR32.5 205.,205 � 1 1•1 0 k , ♦ � 194.92 REPLACE EX. MANHO - I�������������������������������������������_��_��� ������_���_��•���-AL AL _ _ --..- -ALA•-r•�����������AL- -4- ���♦ ��_� - ALONG ALIGNMENT, U.N.D. 4 6; 30" PVC RJ CARRIER PIPE VIA AJSIB'Z-OR �r- 200 PIPE A MIN. 10 LF OUTSIDE CASING. (SEE DEATIL 5-39/SD-3.0) 200 57+00 58+00 59+00 60+00 61 +00 62+00 63+00 64+00 65+00 66+00 (2-PROFILE - STA. 57+00 TO STA. 66+00 co _ 00 Q 0 240 240 235 O 235 rncK 0 0 oo NLL 100-Y FLOOD _ ,-00- - M N = O 00 N N 6 PLAIN ELEVATION u 0 •N z z IX 230 - X• kN--0w I- > > > Q 230 WU)Q' L L 2i wvU �v 225 M W $AO O 225 Q M I I .or N N OW0 : K) LT I Ceo N N c� SMH28 MINIM H co 7'O g 220 220 cr - » Q > 1\ 215 215 210 210 i BOA sik _ AVC 205 205 200 200 -0+50 0+00 1 +00 1 +50 (-3-PROFILE - STA. 00+00 TO STA. 01+17 SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' SEWER ABANDONMENT 1. REMOVED EX. 18" SS AS REQUIRED FOR CONSTRUCTION. PLUG PIPE END WITH MINIMUM 2' CONCRETE PLUG. 2. REMOVED EX. 10" SS AS REQUIRED FOR CONSTRUCTION. PLUG PIPE END WITH MINIMUM 2' CONCRETE PLUG. 3. REMOVE SECTION OF ABANDONED GRAVITY SEWER FROM STREAM. ABANDON A MINIMUM OF 5' BEYOND TOP OF BANK. PLUG PIPE END WITH MIN. 2' CONCRETE PLUG NOTES: 1. ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS. 2. CONTRACTORS TO KEEP ALL SERVICES ACTIVE DURING CONSTRUCTION. 3. INSTALL SERVICES TO EXISTING CLEANOUTS AT EASEMENT. 4. INSTALL NEW CLEANOUT IF ONE DOES NOT EXIST. 5. SEE DETAIL S-5/SD-1.0 FOR TRENCH AND BACKFILL. 6. INSTALL WATER TIGHT FRAME AND COVER WHEN MANHOLE IS LESS THAN 3' ABOVE 100-YR FLOOD ELEVATION, SEE DETAIL S-27/SD-3.0. 7. INSTALL VENT PIPE WHERE INDICATED, SEE DETAIL S-24/SD-2.0. 8. EASEMENT CLEARING: • CLEAR AS NEEDED FOR CONSTRUCTION ON THIS SHEET. STREAM CROSSING NOTES: 1. FOR ALL STREAM CROSSINGS, CONTRACTOR SHALL UTILIZE DAMS AND PUMPING AS NECESSARY TO PREVENT DOWNSTREAM SEDIMENT TRANSPORT (SEE 3/ED-2.0). 2. WHERE EQUIPMENT CROSSING WILL OCCUR CONTRACTOR SHALL INSTALL TEMPORARY STREAM CROSSING (SEE 1 /ED-2.0). 3. UPON FINAL COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL INSTALL PERMANENT STREAM STABILIZATION (SEE 2/ED-2.0). NOTE: ALL CONSTRUCTION SHALL ADHERE TO CITY OF RALEIGH STANDARDS AND SPECIFICATIONS Public Sewer Collection / Extension System The City of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # S-4753 Authorization to Construct See digital signature CITY OF RALEIGH - PLANS AUTHORIZED FOR CONSTRUCTION Plans for the proposed use have been reviewed for general compliance with applicable codes. This limited review, and authorization for construction is not to be considered to represent total compliance with all legal requirements for development and construction. The property owner, design consultants, and contractors are each responsible for compliance with all applicable City, State and Federal laws. This specific authorization below is not a permit, nor shall it be construed to permit any violation of City, State or Federal Law. All construction must be in accordance with all Local, State, and Federal Rules and Regulations. This approval of this electronic document is only valid if the document has not been modified and the digital signature below is valid: m m REVISED PER OWNER COMMENT REVISED PER REGULATORY REVIEW PERMITTING 90% DESIGN z 0 w N 0 0 N u) 0 0 N r` 0 0 0 N 0 r7 0 w 0 HIGHFILL INFRASTRUCTURE ENGINEERING, P.C. 2703 Jones Franklin Rd, Suite 201 Cary, NC 27518 Tel 919-481-4342 www.hiepc.com Firm License No. C-2586 Engineering is our profession. Service is our passion. (f) LL LL 0 up (f) 0 m RALEIGH WATER RALEIGH, NC 0 0 7 PROJECT NO. Al_1 801 SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' City of Raleigh Development Approval