HomeMy WebLinkAboutSW6200904_Response To Comments_20220214Timberland Ranch Minor Modification
Response to DEQ Plan Submittal Comments — SW6200904
Dated November 30, 2021
1. Supplement-EZ Form, Drainage Areas Page, Entire Site Column, Lines 5 & 6 — The entire site area
("Drainage Area") shown here (22,643,938 sf or 519.83 ac) does not match the information shown
elsewhere in the submission (520.306 ac).
Response: The drainage area for lines 5 & 6 have been revised. The application on page 3 has been
revised as well.
2. Supplement-EZ Form, Drainage Areas Page, Entire Site Column, Lines 8 & 12 — Please exclude the
6,000 sf of BUA allocated to lot 69 since this lot is being removed from this permit. You can re-
allocate this BUA to one or more of the other lots, but doing so will require modifying the approved
deed restriction document. You may need to recalculate the %BUA based on this comment.
Kespunse: The 6,000 sf ur BUA allocated to lot 69 (LD1) has ueen rerncrved. The application on
page 3 has been revised as well.
3. Supplement-EZ Form, Drainage Areas Page, Entire Site Column, Line 12 — Please clarify why the
mail kiosk BUA (5,345 sf) is not accounted for in the entire site column (include it if necessary).
Response: Mail kiosk BUA has been included in `entire site' column.
4. Supplement-EZ Form, Drainage Areas Page, Lines 9, 10, & 12 — Line 9 should be used to show the
BUA that is allocated to the individual lots within the entire site/each drainage area. Line 10 should be
used to show the total amount of BUA that is allocated to the common/shared space within the entire
site/each drainage area. Line 12 should be a breakdown of the BUA in line 10 by type (The sum of
the BUA in Line 12 is equal to Line 10 and the sum of Lines 9 & 10 is equal to Line 8).
Response: The Drainage Areas table has been revised. The application on page 3 has been revised
as well.