HomeMy WebLinkAboutSW6200904_Supplement-EZ Form_20220214SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1
Project Name
Timberland Ranch
2
Project Area (ac)
524.24
3
Coastal Wetland Area ac
4
Surface Water Area (ac)
5
Is this project High or Low Density?
Low
6
_
Does this project use an off -site SCM?
No
POMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided feet
N/A
8
Will the vegetated setback remain vegetated?
N/A
9
If BUA is proposed in the setback, does it meet NCAC 02H,1003 4 c-d ?
No
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
8
12
Bioretention Cell
0
13
Wet Pond
0
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
ISand Filter
0
17
Rainwater Harvesting RWH)
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
JStormFilter
0
24
Silva Cell
0
25
Ba filter
0
26
Filterra
0
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title.
Carlo Pardo. PE
28
Organization:
Bowman North Carolina, Ltd.
29
Street address:
4006 Barrett Drive, Suite 104
30
City, State Zip:
Raleigh. NC 27609
31
Phone numbers :
919-553-6570
32
1 Email:
cpardo@bowman.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
��'',��1lLllitillti►IIJ
•••••04� H C ARO
5 10/f
SEAL _
051571
%r •'••.4G1N�.
' 'a
Signs m of Designer`
Date
DRAINAGE AREAS
1
Is this a hicih density project?
No
2
If so, number of drainage areas/SCMs
0
3
Does this project have low density areas?
Yes
4
If so, number of low density drainage areas
8
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
LD 1
LD 2
LD 3
LD 4
4
Type of SCM
Infiltration Trench
Infiltration Trench
Infiltration Trench
Infiltration Trench
5
Total drainage area �sq ft
22835894 sf
212925
80165
111705
185040
6
Onsite drainage area (sq ft
22835894 sf
212925
80165
111705
185040
7
Offsite drains a area (sq ft
8
Total BUA in project (sq ft
1009888 sf
113469 sf
48933 sf
81750 sf
117141 sf
9
New BUA on subdivided lots (subject to permitting)
(sq ft
894000 sf
84000 sf
36000 sf
72000 sf
96000 sf
10permitting)
New BUA not on subdivided lots (subject to
s
115888 sf
29469 sf
12933 sf
9750 sf
21141 sf
11
Offsite BUA (sq ft
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft)
Sidewalk �sg ft
6046 sf
4702 sf
1344 sf
Roof (sq ft
Roadway s ft
104497 sf
24767 sf
11589 sf
9750 sf
15796 sf
Future (sq ft
Other, please specify in the comment box
below (sq ft
5345 sf
5345 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
15permitting)
Existing BUA that will remain (not subject to
s ft
16
Existing BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft
18
Percent BUA
4%
53%
61%
73%
63%
19
Design storm inches
1.0 in
1.0 in
1.0 in
1.0 in
20
Design volume of SCM cu ft
9397 cf
4004 cf
6597 cf
9557 cf
21
1 Calculation method for design volume
Simple Method
1 Simple Method
I Simple Method
Simple Method
ADDITIONAL INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
LD4 Other: Mail Kiosk Impervious
DRAINAGE AREAS
1
Is this a high density project?
No
2
If so, number of drainage areas/SCMs
0
3
Does this project have low density areas?
Yes
4
If so, number of low density drainage areas
8
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
LD 5
LD 6
LD 7
LD 8
4
Type of SCM
Infiltration Trench
Infiltration Trench
Infiltration Trench
Infiltration Trench
5
Total drainage area (sq ft
22835894 sf
96006
113711
182260
201552
6
Onsite drainage area (sq ft
22835894 sf
96006
113711
182260
201552
7
Offsite drainage area (sq ft
8
Total BUA in project (sq ft
1009888 sf
81698 sf
24000 sf
134033 sf
167080 sf
9(sq
New BUA on subdivided lots (subject to permitting)
ft
894000 sf
72000 sf
24000 sf
120000 sf
150000 sf
10permitting)
New BUA not on subdivided lots (subject to
s
115888 sf
9698 sf
14033 sf
17080 sf
11
Offsite BUA (sq ft
12
Breakdown of new BUA not on subdivided lots:
Parking (sq ft
Sidewalk Lsq ft
6046 sf
Roof (sq ft
Roadway s ft
104497 sf
9698 sf
14033 sf
17080 sf
Futuresq ft
Other, please specify in the comment box
below (sq ft
5345 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft
14
New infiltrating permeable pavement not on
J subdivided lots (sq ft
15permitting)
Existing BUA that will remain (not subject to
s ft
16
Existing BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft)
18
Percent BUA
4%
85%
21%
74%u
83%
19
Design storm (inches)
1.0 in
1.0 in
1.0 in
1.0 in
20
1 Desi n volume of SCM cu ft
6527 cf
2274 cf
10812 cf
13371 cf
21
1 Calculation method for design volume
Simple Method
Simple Method
Simple Method
Simple Method
ADDITIONAL INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
LD4 Other: Mail Kiosk Impervious