Loading...
HomeMy WebLinkAboutSW3210301_Plansheet Phase 3 C3.31 - SCM Details_202111180 m m L2"x2"xl/4" GALV STEEL ANGLE (TYP) WELDED FRAME FOR BAR GRATE PANELS FRAME BOLTED TO TOP OF CONCRETE STORM BOX WITH 60"X60" INSIDE AND 72"X72" OUTSIDE DIMENSIONS N 72" * gnu G ARC L2"x2"x1/4" GALVANIZED ANGLE OVERLAPPED AND BOLTED TO RESTRAIN BAR GRATE AND AND STILL ALLOW REMOVAL I" THICK BAR GRATE I/4" x I" GALVANIZED HEXHEAD BOLT, WASHERS, 81 NUT I TACK -WELD NUT TO BACK SIDE �- 61" x 61" LOWER WELDED FRAME L2"x2"xI/4" OTY=1 GALVANIZED ANGLE 5/16" HOLES 72" x 72" FOR CONIC ANCHOR I"x3" GALV STEEL OR I/4"x4" GALV STEEL BOLTS (TYP) ALUMINUM BAR GRATE CONCRETE EXPANSION BOLT FRAME a BAR GRATE CONSTRUCTION BAR GRATE INSTALLATION NTS NTS EXPANDED METAL GRATE TRASH RACK FOR RISER OF A PROVIDE WATERTIGHT CONNECTION 12" THICK (MIN.) CAST -IN -PLACE OR PRECAST CONCRETE COLLAR (MIN. 2000 PSI) ANTI -SEEP COLLAR SPECIFICATIONS PIPE RISER TO ID DIA S NO OF FIRST (IN) (IN) COLLARS COLLAR (FT) WET POND 36 72 1 25 03 NOTES: 1. ALL COLLARS SHALL BE INSTALLED TO BE WATER -TIGHT. 2. COLLAR DIMENSIONS TO EXTEND 18" (MIN) BEYOND SPECIFIED PIPE DIAMETER ON ALL SIDES. 3. FIRST ANTI -SEEP COLLAR TO BE LOCATED SLIGHTLY DOWNSTREAM OF DAM CENTER LINE. ANTI -SEEP COLLAR COMPACTED SOIL (CLAY) LINER SPECIFICATIONS THE BMP POND SHALL INCLUDE A COMPACTED SOIL LINER. THE EARTHWORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, SUPERVISION, AND EQUIPMENT TO COMPLETE THE COMPACTED SOIL LINER FOR THE POND INCLUDING THE FOLLOWING OPERATIONS: HAULING, SIEVING, RAKING, DISCING, COMPACTING, DRYING, WETTING, REMOVAL OF RAINWATER, REMOVAL OF ALL PREVIOUSLY PLACED MATERIAL RENDERED UNSUITABLE DUE TO WEATHER CONDITIONS OR CONSTRUCTION OPERATIONS, FINAL GRADING AND SEALING, AND ALL NECESSARY AND INCIDENTAL ITEMS AS DETAILED OR REQUIRED TO COMPLETE THE COMPACTED LINER. SOIL LINER FILL MATERIALS ARE POTENTIALLY ON -SITE. ON -SITE SOILS THAT MEET THE FOLLOWING REQUIREMENTS SHALL BE CLASSIFIED AS SOIL LINER FILL MATERIAL AND MAY BE USED IN THE CONSTRUCTION OF THE COMPACTED SOIL LINER: 1. LIQUID LIMIT, PLASTICITY INDEX, AND PERCENT PASSING THE NO. 200 SIEVE WILL BE CONSIDERED FOR PROPER CLASSIFICATION. THE SOIL LINER MATERIAL SHALL HAVE A PLASTICITY INDEX GREATER THAN 20 OR AS SUBSEQUENTLY SPECIFIED BASED ON LABORATORY TESTING, AND HAVE A SOIL PERMEABILITY OF 1 E-5 CM/SEC OR SLOWER AS DETERMINED BY SOIL PERMEABILITY (ASTM D5084). 2. SOIL LINER FILL MATERIALS SHALL BE REASONABLY FREE OF GYPSUM, FERROUS, AND/OR CALCAREOUS CONCRETIONS AND NODULES OR OTHER DELETERIOUS SUBSTANCES. SOIL LINER MATERIAL SHALL BE RAKED OR SIEVED BY THE EARTHWORK CONTRACTOR, IF NECESSARY, TO REMOVE ALL AGGREGATE GREATER THAN 1 INCH IN DIAMETER. NO MORE THAN 5 PERCENT OF THE SOIL LINER FILL MATERIAL SHOULD BE RETAINED IN THE NO. 4 SIEVE. 3. PRIOR TO COMPACTION, ALL CLAY CLODS WILL BE BROKEN DOWN WITH TILLERS AND/OR DISCS TO PROVIDE A HOMOGENEOUS CLAY SOIL THAT IS FREE OF CLAY CLODS LARGER THAN 2 INCHES IN DIAMETER. CONSTRUCTION 1. CONSTRUCTION METHODS, SAMPLING AND TESTING WILL BE RECOMMENDED BY THE GEOTECHNICAL. TYPICAL TESTS TO BE INCLUDED ARE MOISTURE CONTENT, IN -PLACE DENSITY, ATTERBERG LIMITS AND PERMEABILITY TESTING.. 2. PRIOR TO SOIL LINER PLACEMENT, THE PREPARED SUBGRADE SHALL BE PROOFROLLED WITH A LOADED DUMP TRUCK (MIN. 20 TONS) OR SIMILAR RUBBER TIRED PNEUMATIC VEHICLE, A MINIMUM OF TWO PASSES IN EACH DIRECTION. 3. LOOSE SOIL LINER FILL LIFT THICKNESS, PRIOR TO COMPACTION, SHALL BE A MAXIMUM OF 6 INCHES. THINNER LIFTS ARE PERMISSIBLE TO ACHIEVE DESIGN GRADE AND/OR SOIL LINER PROPERTY SPECIFICATIONS. 4. EQUIPMENT OR TRUCK TRAFFIC SHALL NOT BE PERMITTED DURING THE PERIOD BETWEEN SCARIFYING AND COMPACTION OF A LIFT UNLESS APPROVED BY THE ENGINEER. 5. SOIL LINER FILL SHALL NOT BE PLACED OR COMPACTED DURING SUSTAINED PERIODS OF AIR TEMPERATURES BELOW 32 DEGREES F. IF THE SOIL LINER FILL FREEZES OR ICES THE FILL SECTION SHALL BE RE -SCARIFIED AND RE -COMPACTED. 6. THE COMPACTED SOIL LINER SHALL BE CONSTRUCTED TO THE MINIMUM THICKNESS SPECIFIED BY THE PROJECT PLANS. 7. AFTER COMPLETION OF A SEGMENT OF COMPACTED SOIL LINER, BUT BEFORE INSTALLATION OF THE TOPSOIL PROTECTIVE LAYER, THE SURFACE OF THE SOIL LINER SHALL BE SURVEYED BY THE CONTRACTOR TO ENSURE THE SPECIFIED THICKNESS OF COMPACTED SOIL LINER. NOTE NCDEQ WILL REQUIRE AN OPEN OPERATION AND MAINTENANCE PLAN AND INSPECTION AND MAINTENANCE AGREEMENT. D SAFETY FENCE (ALONG PERIMETER) STORMWATER RUNOFF MINIMUM MAINTENANCE SCHEDULE 1. AFTER EVERY SIGNIFICANT RUNOFF PRODUCING RAINFALL EVENT AND AT LEAST MONTHLY: 1.1 INSPECT THE DETENTION BASIN SYSTEM FOR SEDIMENT ACCUMULATION, EROSION, TRASH ACCUMULATION, VEGETATED COVER, AND GENERAL CONDITION. 1.2 CHECK AND CLEAR THE ORIFICE OF ANY OBSTRUCTIONS THAT WOULD INTERFERE WITH THE DRAW DOWN OF THE TEMPORARY POOL AS DESIGNED. 2. REPAIR ERODED AREAS IMMEDIATELY. RE -SEED THE EMBANKMENT AS NECESSARY TO MAINTAIN GOOD VEGETATIVE COVER. MOW VEGETATIVE COVER ON EMBANKMENT TO MAINTAIN A MAXIMUM HEIGHT OF SIX INCHES, REMOVE TRASH AS NEEDED. 3. INSPECT AND REPAIR THE COLLECTION SYSTEM (I.E. CATCH BASINS, PIPING, SWALES, RIP RAP, ETC.) QUARTERLY TO MAINTAIN PROPER FUNCTIONING. 4. REMOVE WOODY VEGETATION NOT PART OF THE APPROVED PLAN ALONG THE DAM EMBANKMENT. 5. REMOVE ACCUMULATED SEDIMENT FROM THE WET DETENTION BASIN SYSTEM SEMI-ANNUALLY OR WHEN THE DEPTH IS REDUCED TO 75% OF THE ORIGINAL DESIGN DEPTH. REMOVED SEDIMENT SHALL BE DISPOSED OF IN AN APPROPRIATE MANNER AND SHALL BE HANDLED IN A MANNER THAT WILL NOT ADVERSELY IMPACT WATER QUALITY (I.E. STOCKPILING NEAR A WET DETENTION BASIN OR STREAM, ETC.). 6. PERFORM ANNUAL INSPECTION OF THE BASIN (ANNUAL INSPECTION REPORTS TO BE KEPT BY THE OWNER). PRIOR TO INSPECTION NOTIFICATION MUST BE GIVEN TO STORM WATER SERVICES. NOTE THE PRECAST MANUFACTURER IS TO PREPARE AND SUBMIT TO THE ENGINEER DESIGN DETAILS AND CALCULATIONS FOR THE STRUCTURES SHOWN BASED ON THE DESIGN CRITERIA SPECIFIED. THE DESIGN SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION AND SEALED BY A PROFESSIONAL ENGINEER REFEREED IN THE STATE OF NORTH CAROLINA EXPERIENCED IN THE DESIGN OF PRECAST CONCRETE. THE DESIGN SHALL INCLUDE PROVISION S FOR HANDLING STRESSES AND CONSTRUCTION LOADS. REPRODUCED COPIES OF ASTM C789 "STANDARD SPECIFICATIONS FOR PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS" WILL NOT BE ACCEPTED AS A SUBSTITUTED FOR DESIGN. EMBANKMENT CONSTRUCTION NOTES GENERAL 1. THE POND AND DAM AREA SHALL BE CLEARED, GRUBBED AND STRIPPED OF ALL VEGETATIVE MATERIAL AND TOPSOIL PRIOR TO DAM CONSTRUCTION, THE DISPOSAL OF TREES, STUMPS, CONSTRUCTION DEBRIS, VEGETATIVE MATERIAL, ETC. SHALL NOT BE PERMITTED IN THE DAM OR POOL AREA OF THE POND. WHEN BLASTING IS USED TO REMOVE ROCK FROM THE POOL AREA, THE BLASTED AREA SHALL BE OVER -EXCAVATED TO A DEPTH OF AT LEAST TWO FEET (2) BELOW FINISH GRADE AND BROUGHT BACK TO FINISH GRADE WITH CLEAN RELATIVELY IMPERVIOUS SOIL MATERIAL COMPACTED IN PLACE. EARTH FILL DAMS 1. SOIL MATERIALS USED FOR EARTH FILL WHICH ARE HIGHLY PERMEABLE OR WHICH EXHIBIT SIGNIFICANT. 2. EMBANKMENTS FILL MATERIAL TO BE COMPACTED TO AT LEAST 95% STANDARD PROCTOR COMPACTION. 3. SHRINKAGE SWELL, OR DISPERSION SHALL NOT BE USED IN THE EMBANKMENT. 4. A CUTOFF TRENCH (CORE TRENCH) SHALL BE PROVIDED WITH A MINIMUM WIDTH OF FIVE FEET (5'). THE CENTERLINE OF THE CUTOFF TRENCH SHALL NOT BE LOCATED DOWNSTREAM OF THE INSIDE TOP OF SLOPE OF THE DAM. THE CUTOFF TRENCH SHALL BE CAREFULLY BACK -FILLED WITH HIGHLY IMPERMEABLE MATERIAL AND COMPACTED TO AT LEAST NINETY-FIVE PERCENT (95%) OF STANDARD PROCTOR DENSITY. 5. THE MINIMUM TOP WIDTH OF THE DAM SHALL BE TEN FEET (10') AND SLOPES SHALL NOT BE STEEPER THAN 2:1 (TWO HORIZONTAL TO ONE VERTICAL) ON THE DAM OR EMBANKMENTS AROUND THE POND. 6. ALL DISTURBED GROUND AREAS AND EMBANKMENTS SURROUNDING THE POND SHALL BE MECHANICALLY STABILIZED AND HAVE PERMANENT GROUND COVER ESTABLISHED IN ACCORDANCE WITH THE PERMANENT SEEDING SCHEDULE. EXPANDED METAL GRATE TRASH RACK FOR RISER (SEE DETAILS) (CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL BY THE ENGINEER) SO OUTLET PI SECTION A -A EXPANDED METAL GRATE TRASH RACK FOR RISER (SEE DETAILS) F- - - - - - - I l OUTLET PIPE 1. OUTFALL STRUCTURE SHALL HAVE 6" THICK WALLS. 2. INSIDE DIMENSIONS OF OUTFALL STRUCTURE SHALL BE 5'x5'. 3. ENDS OF ALL PIPES SHALL BE FLUSH WITH INSIDE WALL OF STRUCTURE. 4. PIPE OPENING TO BE WATERTIGHT CONTROL STRUCTURE NOT TO SCALE POND SECTIONAL VIEW BASIN LENGTH TRASH RISER CREST = 573.00 100-YR WATER SURFACE ELEVATION = 571.99 - - - - - - - - - - - - - - - - _ 50-YR WATER SURFACE ELEVATION = 571.62_ - - - - - - - - - - - - - - - 25-YR WATER SURFACE ELEVATION=571.12 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10-YR WATER SURFACE ELEVATION = 570.53- - - - - - - - - - - - - - - _ - _ MIN. 2' 1 6' (TYP) � I _nN INLET VEGETATIVE SHE, o NORMAL WATER = 567 - 6:1 SLOPE \ SEDIMENT o 0 0 4 5' PERMANENT / \ FOREBAY F R BAYBERR POOL DEPTH CL-II RIPRAP (SEE DETAIL) / SEDIMENT STORAGE ELEV=563.00 _____ STABILIZATION BASIN BOTTOM = 562.50 \___FOREBAY EXIT ELEV: 562.50 12" CLAY LINER SHALL BE FOREBAY ENTRANCE CONSTRUCTED OR COMPACTED ELEV: 562.00 SUCH THAT INFILTRATION RATE SEDIMENT STORAGE S NOT MORE THAN .011N/HR FOREBAY ENTRANCE ELEV: 562.50 WET DETENTION POND 4 SEDIMENT STORAGE NOT TO SCALE FOREBAY EXIT ELEV: 563.00 VEGE'1 ATIVE SHELF � 6:1 SLOPE 0, MI - - \IUY OF tMtlANKMtNI = 0/J.5 / - - - -%�ERGENA = 572.75 EARTHEN DAMArm-SEEP COLURSEE DETAIL. 'ONTROL -RUCTURE(SEE APRON DETAIL) DETAIL)) 1 BASIN BOTTOM SLOPE RISER ANTI -FLOATATION GLASS IV RCP (0.5% MIN.) PUMP TO BE UTILIZED TO DEWATER POND TO OUTLET PIPE WITH FACILITATE MAINTENANCE WATERTIGHT JOINTS AND INSPECTION NOTE: SEE GRADING PLAN SHEET C3 5 FOR PIPE INVERTS, PIPE SIZE, AND PIPE LENGTHS �O Zz F:may% U) U F, OD =Q HwU 1 a U 0DZULL o Z H (D 0 i Y ct5 Z Z CS w N N N w \ cli \ ti N Q = m Y Y Y U) Tn c m 0 U) N z z z 0 w w > 0 0 w U U Z w w g F- F- o Q Q U o o z U) Tn 0 U 0 o w w z 0 0 0 U U z z z 0 m a Z Lo O Lo Z Lo E;O E Q O ('4 U 00 N O O ' Q N � � 04 0 `2 1 T� i �N Lu U oZ 0 E C4 O O 7- 3 0 3 O U U U) J J_ J Q � w () w W Q 0 z Q � = � co Vz I a u J z z CL o 0 U� z U) 0 W Ld CL 3 � � W 3 Y JOB NO: J-27842 0003 DATE: 4/5/21 DRAWN: KSC DESIGNED: DAC REVIEWED: MSK APPROVED: MSK SCALE: I" = 30' IC3.31..j J z O U) W U) O d d W_ W O W H W U) H_ d' W a NOT TO SCALE NOT TO SCALE