HomeMy WebLinkAboutNC0080691_Compliance Evaluation Inspection_20220127ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
S. DANIEL SMITH
Director
Shannon Becker, President
Aqua North Carolina, Inc.
202 MacKenan Court
Cary, North Carolina 27511
Dear Mr. Becker:
NORTH CAROLINA
Environmental Quality
January 27, 2022
Subject: Compliance Evaluation Inspection
Windemere WWTP
NPDES Permit No. NC0080691
Catawba County
Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject
facility on January 13, 2022, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge
(ORC) of our findings by forwarding a copy of the enclosed report.
Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192,
or via email at wes.bell@ncdenr.gov.
Enclosure: Inspection Report
NORTH
Deparlmant of Environmental Ouallt
Sincerely,
DocuSigned by:
c
w H rque4
F161 FB69A2D84A3...
fo r
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality 1 Division of Water Resources
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704.663.1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 IL
21IIIIII
I
NPDES yr/mo/day Inspection
3 I NC0080691 111 121 22/01/13 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIIIIIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 I 70I4 I 71IN I 72 I N I 73I 1 74 751
I I 1
I I I I I I 180
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Windemere WWTP
NCSR 1328 Heronwood Rd
Sherrills Ford NC 28673
Entry Time/Date
01:33PM 22/01/13
Permit Effective Date
20/07/01
Exit Time/Date
02:40PM 22/01/13
Permit Expiration Date
25/03/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Ricky Dean Reynolds/ORC//
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Shannon V Becker,202 Mackenan Dr Cary NC 275116447/President/919-653-5570/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Wes Bell
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
—Docusigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 1/26/2022
"-A61696D90CC3437...
Signature of Ma
Andrew Pitn.r��
ga emen'AdFeviewer Agency/Office/Phone and Fax Numbers Date
.4414VH D R/MRO WQ/704-663-1699 Ext.2180/ 1.27.22
<F161FB69A2D84A3...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
NPDES yr/mo/day
31 NC0080691 111 121 22/01/13
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑
application?
Is the facility as described in the permit? • ❑ El El
# Are there any special conditions for the permit? • ❑ ❑ ❑
Is access to the plant site restricted to the general public? • ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: The last compliance evaluation inspection at this facility was performed by DWR staff
on 8/27/19.
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
•
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: The records reviewed during the inspection were organized and well maintained.
Discharge monitoring reports (eDMRs) were reviewed for the period December 2020
through November 2021. No effluent limit and/or monitoring violations were reported.
Page# 3
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: On -site effluent field analyses (dissolved oxygen, pH, temperature and total residual
chlorine) are performed under the Aqua N.C.'s field laboratory certification #5035.
Water Tech Labs (Certification #50) has been contracted to provide analytical support.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? • ❑ ❑ ❑
Is sample collected below all treatment units? • ❑ ❑ ❑
Is proper volume collected? • ❑ ❑ ❑
Is the tubing clean? • ❑ ❑ ❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑
representative)?
Comment: The subject permit requires effluent composite and grab samples. The ORC must
ensure to perform and document monthly (at a minimum) sampler aliquot verifications.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ▪ ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The wastewater treatment facility appeared to be properly operated and well
maintained. Process control measurements were being documented and maintained
on -site.
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Yes No NA NE
Page# 4
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
Equalization Basins Yes No NA NE
Are float controls operable? • ❑ ❑ ❑
Are audible and visual alarms operable? • ❑ ❑ ❑
# Is basin size/volume adequate? • ❑ El El
Comment: The telemetry type alarm system (high water) did not operate properly during the
on -site test; however, the electrical issue was repaired and the alarm system was
operational by the next day.
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Diffused
Is the basin free of dead spots? • ❑ El El
Are surface aerators and mixers operational? El El • El
Are the diffusers operational? • El El El
Is the foam the proper color for the treatment process? • El El El
Does the foam cover less than 25% of the basin's surface? • El El El
Is the DO level acceptable? • El El El
Is the DO level acceptable?(1.0 to 3.0 mg/I) • El El El
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment:
Filtration (Hiqh Rate Tertiary)
Yes No NA NE
• ❑ ❑ ❑
• ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
Page# 5
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
Filtration (High Rate Tertiary) Yes No NA NE
Type of operation: Down flow
Is the filter media present? • ❑ El El
Is the filter surface free of clogging? • ❑ ❑ ❑
Is the filter free of growth? • ❑ ❑ ❑
Is the air scour operational? • ❑ ❑ ❑
Is the scouring acceptable? • ❑ ❑ ❑
Is the clear well free of excessive solids and filter media? • ❑ ❑ ❑
Comment:
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ ❑ ❑
Are the tablets the proper size and type? • ❑ ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? • ❑ ❑ ❑
Is the contact chamber free of growth, or sludge buildup? ■ ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? • ❑ ❑ ❑
Comment. Calcium hypochlorite tablets were used for disinfection.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
• ❑ ❑ ❑
▪ ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: The flow meter is calibrated annually and was last calibrated by Aqua NC staff on
7/14/21.
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Yes No NA NE
Tablet
• ❑ • ❑
❑ ❑ • ❑
• ❑ ❑ ❑
Page# 6
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
De -chlorination Yes No NA NE
Are tablet de -chlorinators operational? • ❑ ❑ ❑
Number of tubes in use? 4
Comment: Sodium Sulfite tablets were used for dechlorination. Post aeration is provided following
dechlorination.
Pump Station - Effluent Yes No NA NE
Is the pump wet well free of bypass lines or structures? ■ ❑ ❑ ❑
Are all pumps present? • ❑ ❑ ❑
Are all pumps operable? • ❑ ❑ ❑
Are float controls operable? • ❑ ❑ ❑
Is SCADA telemetry available and operational? El • El El
Is audible and visual alarm available and operational? ❑ • ❑ ❑
Comment: The telemetry type alarm system (high water) did not operate properly during the
on -site test; however, the electrical issue was repaired and the alarm system was
operational by the next day.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment: The effluent appeared clear with no floatable solids or foam. The effluent is
discharged (via submerged outfall) into the receiving stream.
Yes No NA NE
❑ ❑ ❑ •
❑ ❑ ❑ •
Aerobic Digester Yes No NA NE
Is the capacity adequate? • El El El
Is the mixing adequate? • El El El
Is the site free of excessive foaming in the tank? • ❑ ❑ ❑
# Is the odor acceptable? ■ El El El
# Is tankage available for properly waste sludge? • El El El
Comment: Wastewater solids are removed by a contracted company (Lake Norman Sewer &
Septic Services).
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 7
Permit: NC0080691
Inspection Date: 01/13/2022
Owner - Facility: Windemere WWTP
Inspection Type: Compliance Evaluation
Standby Power Yes No NA NE
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up
power?
Is the generator fuel level monitored?
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The backup generator is tested weekly (automatically) and periodically placed under
load. Managed Generator Services has been contracted to service the generator
quarterly.
Page# 8