Loading...
HomeMy WebLinkAboutWQ0043182_Application (FTSE)_20220118State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number; t,;.p (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Durham County (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County ❑ Municipal ❑ Other 3. Signature authority's name: Stephanie Brixgy per 15A NC C 02T .0106(b} Title: POTW Director NC Dept of Savimametttal Quality 4. Applicant's mailing address: 5926 Highway 55 East, City: Durham State: NC Zip: 27713- JA4 1 8 5. Applicant's contact information: Phone number: 9( 19) 560-9034 Email Address: sbrixeyCa)dconc.gov weigh Regional Offtco II. PROJECT INFORMATION: I. Project name: 3404 Page Road 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Durham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.90235' Longitude:-78.81879� 5. Parcel ID (if applicable): 157692 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Alden West License Number: 042680 Firm: Stewart Inc. Mailing address: 101 W. Main Street City: Durham State: NC Zip: 27701- Phone number: (9l9) 8664721 Email Address: awest(a)stewartinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Triangle Wastewater Treatment Facility Permit Number: NCO026051 Owner Name: Durham County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0037889 Downstream (Receiving) Sewer Size: 8 inch SSy is an Wide Collection System Permit Numbers I 6f anylicablei: WQCS00038 Owner Name(s): Durham County FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Devel w's Overalmonal Agleement (FORM: DE ) been attached? ❑ Yes ❑No ®N. A 3. If the Applicant is a Huiric-Pr❑porty_Owners' Association, has an Opera[ional Agrecrnent (FORM: HOA) been attached? ❑ Yes ❑No ON.. -'A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool day care ❑ Medical f dental I veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater. I00 °fo Domestic/Commercial 0 % Commercial % Industrial (See I SA NC -AC 02T .0 [ 03(20 ) 4Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 0 2 T .01 14t0? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see U11,01140 Daily Design Flow' b No. of Units Flow Townhomes 360 gat/day 188 67,680 GPD gal/ GPD gal/ GPD gal/ GPD gat/ GPD gat/ GPD Total 67,680 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 67,680 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 2,900 PVC 8 1,226 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T _0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(l)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORIM: FTA 04-16 Page 3 of 5 1X. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in I SA NCAC 02T .030 ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems, ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class 1 or CIass II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T_03U%SJ contains alternatives where separations in 02T.0305(D cannot be achieved. ➢ "Stream classifications can be identified using the Division's NC Surface Watcr Classifications web e ➢ If noncompliance with 02T.0305(f) or (g,). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes ❑ No ❑ N!A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02A .02007 ® Yes ❑ No ❑ N;;A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105fc1f61(additional permits/certifications)? ® Yes ❑ No Per I5A NCAC 02T.0105(c1(6h directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T_0402 "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [--]Yes ® No ❑ N.'A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 021, the Minimum DesmtCnretL, fpr the Pcrrmilllllt 9LmA_st.1t i(Ills and � orce Mains (latest version 1. and true QroyiD. Sewer Migmmum Desionv as applicable? ® Yea ❑ No If No, complete and submit the Variance/Altetnative Design Request application (VADC 10-14) and supporting docurnan for review- 2. Professional Engineer Certification: Alden West attest that this application for (Professional Rn&='s came from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, q=itications, enginm ing W Wations, smd all other supporting documentation to the best of my knowledge. I i4rther attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Pmmitticg of Pump Stations and Form Mains (latest version). Al&mgb other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B. any person who knowingly makes my false statement, representation, or oeftifcmtion m any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North CaroliQa Pxofestlonad Eaglneer's seal, sigoatare, and date: CaRQ���'-.,��, � M kC�e ' y 042"0 r+ AfofF�y. :Q �NCtN�q.�4,�y� OZA Applicant's CertiScationper 1SA NCAC 02T .0106(b): � o�� rrrr,R,��+�``��,, attest t this application for (Signature Authoririty% name & title $om Applia� ) Q has been reviewed by are and is accurate and complete to the best of my knowlcdg d that if all required parts of this application are not completed and that if all required supporting documentation ts are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an h mtediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be retatmed to me as incomplete. NOTE — In accordance with General Statures 143 215.6A and 143-215& . any person who knowingly mattes any false statement, representatim or cemfication in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. signatwz: `r~ f�Q Date: --A 1p I a0a 'ZL FORM; FTA 04-16 Page 5 of 5 State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Durham County Project Name for which flow is being requested: 3404 Page Road More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Triangle Wastewater Treatment Plant b. WWTP Facility Permit #: NC0026051 A1I flows are in MGD c. WWTP facility's permitted flow 12 t� d. Estimated obligated flow not yet tributary to the WWTP 1.932 e. WWTP facility's actual avg. flow 4.227 ib f. Total flow for this specific request 0.06768 g. Total actual and obligated flows to the facility 6.227 h. Percent of permitted flow used 51.9 11. Complete this section for each pump station you are responsible for along the route of this prosed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. 6tarcm Stirrupiron -1propoJtd Stirruplron Mproycoltnti (A) (B) Design Average Approx. Daily Current Firm Flow** Avg. Daily Capacity, * (Firm 1 pfl, Flow, MGD MGD MGD 6.50 2.60 2.416 (C) (D)=(B+C) (E)=(A-D) Obligated, Total Not Yet Current Flow Tributary Plus Daily Flow, Obligated Available MGD Flow Capacity*** 0.226 2.642 7.50 3.00 2.416 0.226 2.642 -0.042 0.358 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): -Durham County Sewer Downstream Permit Number: WQCS00038 x 0 ty Page 1 of 6 FTSE 10-18 Ill. Certification Statement: I _5i {( - G certify to the best of my knowledge that the addition of the volum�wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing OlficiaPSignature r� T rlle of ,Sj V.1 a Page 2 of 6 FTSE 10-18 hi PLANNING ASSESSMENT ADDENDUM (PAA) I Submit a planning assessment addendum for each pump station listed in Section 11 where Available Capacity is < 0. Pump Station (Name or Number): Given that; a, The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 8.7 % and 0.226 MGD of the Available Capacity (E) in Pump Station Stirrup Iron Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.4 MGD per year, and that c. A funded Capital Project that will provide the required planned capacity, namely _ is in design or under construction with planned completion in _ ; andlor d. The following applies; Kimley Hord has submitted apermit application on behalf of Durham Coun , for proposed modifications to the Stirrup Iron Creek Pump Station. These PLC modifications would increase the firm capacity and accEptabie flow to 7.5 MGD. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143m 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. ,Si1,7rrirrg () lc' I Signature ao Za 1)alc Page 3 of 6 FTSE 10-19 6/16/2020 Durham Maps I City of Durham and Durham County W71 . r 12+� L�'�tLTt Address Points Parcets, Durham County City of Raleigh, NC CGIA USDA FSA t Est, Community Maps Conuihutors, City of Raleigh. Town of Cary, County of Durham, State of Nortl- Carolina DOT, B-.uldingFootprmtUSA. Est HERE Gar 300 ft https:/Imaps.durhamnc.gov/?x=35.90173608725822&y=-78.81793631346922&z=4513.9887055&r=D&b=1&s=default&l=active address_points,county... 1+1 U.5, DECL GEOLOGICAL SURM PARTIA[Iff OFTHE WTMM NO $WnWAST OURWA QUMWUW.Lt MOM CAROLKA It � 7 • � �•{•rO•M R'r,�t by 4 y � � d , �•N RALKIG f SITP I ai SCALE 114O7 0-- W—M L-Lij MMEAST DUXIUAI, HC SOmu STEWART 3404 Page Road -- Public Sanitary Sewer Extension Narrative City of Durham, Durham County, North Carolina The referenced site is located west of Page Road and north of Pulitzer Lane. The sanitary sewer extension is to be built to serve a residential townhome community of 188 units constructed in 3 phases. The sewer will be conveyed to an existing sanitary sewer outfall to the west of the site. Below is a table estimating the flows for this system at the ultimate build -out. The following flow rates have been determined using the NCDENR Division of Water Quality 02T Standards: TOTAL PHASE USE # UNIT G/D/SF FLOW alud alder 3 Bedroom 1 Townhome 82 Bedrooms _ 360 29,520 3 Bedroom 2 Townhome 61 Bedrooms 360 211960 3 Bedroom 3 _ Townhome 45 - Bedrooms 360 16,200 Sub Total 67,680 The flows generated from all phases is what is being requested at this time. STRONGER SY DESIGN 101 WEST MAIN ST. T 919.380.8750 DURHAM, NC 27701 R 919.380.8752 LETTER OF TRANSMITTAL i STEWART NC Dept of Enviroamental Quality TO FROM JAN 19 NCDEQ - DWR TIM SUMMERVILLE FTSE PERMITTING AND REVIEW Raleigh Regional Office 3800 Barrett Drive (919) 866-4794 Raleigh, NC 27609 DATE SENT VIA 01.14.2022 Hand Delivery PROJECT NUMBER PROJECT NAME L17024 Page Road Townhomes COPIES DATE DESCRIPTION 1 COMPLETED FTSE APPLICATION 1 FLOW TRACKING APPLICATION 1 COVER LETTER 1 1 STREET LEVEL MAP 1 USGS MAP 1 CHECK FOR $480 For approval ❑ For review & comment Returned for corrections For your use ❑ Approved as submittedE Returned after review As requested ❑ Approved as noted Resubmit copies for approval COMMENTS Please find enclosed Fast Track Sewer Application and all supporting documents including plans and submittal fee. Contact me at 919.740.3397 or tsummcrville@stewartinc_com if additional information is required. SIGNED COPIED TO File STRONGER BY DESIGN 101 wEST MAIN ST. T 919.380.8750 DURHAM, NC 27701 F 919.380.8752