Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0038371_Regional Office Historical File Pre 2018
Water Resources ENVIRONMENTAL QUALITY Ms. Crystal Panico, New Development Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 Dear Ms. Panico: A`T MCCRORY Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director April 1, 2016 Program Manager Subject: Permit No. WQ0038371 Union County Public Works Dhulab Medical Offices Wastewater Collection System Extension Permit Union County In accordance with your application received March 23, 2016, we are forwarding herewith Permit No. WQ0038371 dated April 1, 2016, to Union County Public Works (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office' 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 if you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. bvNLCorey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional C]fhoe Division ofWater Resources, N[DE[l cc: Todd Michael Born, P.E.(e-cum) Regional Office Files Water Resources Central Files Page 2 of 8 Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT in accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works Union County for the construction and operation of approximately 381.04 linear feet of 8-inch gravity sewer, to serve 2 medical office buildings as part of the Dhulab Medical Offices project, and the discharge of 2000 gallons per day of collected domestic wastewater into the Union County Public Works existing sewerage system, pursuant to the application received March 23, 2016, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12,1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified co •iti•ns`nd imitations contained therein. byW. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: WQ0038371 Permit Issued: April 1, 2016 Page 3of8 SUPPLEMENT TO PERMIT COVER SHEET Union County Public Works is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Union County Twelve Mite Creek Wastewater Treatment Plant in accordance with Permit Number NC0085359. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 2000 gallons per day, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143-2151(d3)] This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110j This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4, The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T 0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: Page 4 of 8 ppP a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. 1. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc. or b. Any SSO and/or spill over 1,000 gallons or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Page 6 of 8 Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 027.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)1 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST'TRACK SE PER&NRT6E: 9ER&M|T#: PROJECT: ISSUE DATE: ERENGINEERING CERTIFICATION Union County Public Works VVQ0038372 Dhu|abMedical Offices April 1,Z016 This projectshaUnotbeconoWeredc0mpletenora|lowedtuVperatelnaccmrdancevvithConditioo7of this permit until the Division has received this Certification and all required supporting documentation. It should besubmitted inamanner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered o violation of the permit and shall subject the Perrnittee to appropriate enforcement actions, The Perrni\tee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set ofrecord drawings and design calculations regardless nfwhether partials have been submitted. PERM[rrEE'S[ERT»F|CAr|ON Lthe undersigned agpntfnrthePennktee,herebvsta0uthotthisprojecthasboenromstnuctedpursuant to the applicable standards& requirements, the Professional Engineer be|nm/ has provided applicable design/construction information tothe Permi|ten, and the Pemnitteeisprepared tnoperate &maintain the wastewater collection system permitted herein o/portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION L _ __ , as a duly registered Professional E r in the State of North Carolina, having been authorized to observe (__ periodically, | \ weekly, � full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care, and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit 15/\ NCa[0IT; the Division of Water Resources' (Division) Gravity Sewer K8iuinoom Design Criteria adopted February 12, 1996,asapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting nfPump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: nFina| Partial (include description Certification Comments/Qualifiers ifnecmssamA- otat"ormurthcar^luim|cn~rQ"m*matguuty|Wmtermes"wces Iwater Qu6no^oioualumeTatio" wW"sVillem°*o=uOffice |mnFast Center ^.ei=.Suite s`,|Mooresville, North Carolina ze'0 e USE THE TAB KEY TO MOVE FROM FIELD TO FIELD Application Number: (to be completed by DWR) tQwnerlPQrnnittee:-�._� 1a. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) stal Panico, PE, New Develo went Pro ram Manager Signing Official Name and Title (Please review 15A NCAC 2T . 106 (b - lc. The legal entity who will own this system is: Individual 0 Federal 0 Municipality Q ld. 500 N. Main. Street, Suite 400 LL Mailing Address Z North Carolina uthorized signing officials State/County 0 Private Partnership 0 State 1 h, (704) 296-4239 'ti. (704) 296-4232 Telephone Facsimile 2. Proiect (Facility) Information: 2a. Dhulab Medical Offices _ 0.. Brief Project Name (permit witl refer to Phis name) 3. Contact Person: 3a. Crystal Panico, PE Name and Affiliation of 3b (704) 296-4239 Phone Number le. Monroe City 28112. Zip Code c stai.panico E-mail 2b. Union orporation 0 0 unioncountvnc.rlov County Where Project i ho Can Answer Questions About this Application 3c. crystal.panico@unio Project is New 0 Modification an e ing permi E-mail Modification, Permit No.: ountyrt .s ov Owner iPublic (skip to Item 8(3) 0 Private (go to Item 2(e)) If private, applicant will be. Retaining Ownership (i.e. store, church, single office, etc.) o 0 Leasing units (lots„ townhomes, etc, skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) Union County Public Works 2b. If sold, facilities owned by a (must choos one) 0 Public Utility (Instruction D) 0 Homeowner Assoc,/Developer (Instruction E) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a Tweivemile Wastewater Treatment Plant �_ ... 4b. NC0085359359 u� Name of WWTF 5a, Union County Public Works 5b. 8 Owner of Downstream Sewer Receiving 6. The origin of this wastewater is (check all 0 Residential Subdivision 0 Apartments/Condominiums • Mobile Home Park 0 School O Restaurant Office I Gravity Sewer Size 10 Force Main that apply)- 0 Retail (Stores, shopping centers) 0 Institution 0 Hospital 0 Church 0 Nursing Home 0 Other (specify): WWTF Permit No. 5c. WQ0020132 Permit # of Downstream Instruction F) 100% Domestic/Commercial % Industrial (Attach Description) ° Other (Attach_ Desch Volume of wastewater to be allocated or permitted for this particular project 2,000 gallons per day *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0' Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA f)-14 APPLICATION Page 4of 6 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for tine or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). (2) Buildings with (4) practitioners & (1) shift per building x 250 GPD per practitioner per shift = 2,000 GPD. 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8 381.04 New Gravity ! W M Z ,, '11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Z 0 Pump Station Location ID: (self chosen - as shown on plans/map for reference) 0 Longitude: Latitude: Z 0 Q 2 Design Flow (MGD) Operational Point GPM grim2 Power Reliability Option 1 - permanent generator w/ATS; - portable generator w/MTS . Force Main Size Force Main Length re 0 I.L. ? PumpStation Location ID: (self chosen - as shown on plans/map for reference) Longitude: Latitude: ' le IJ.I O. • m Design Flow (MGD) GPM @TDH Operational Point Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generator w/MTS Force Main Size Force Main Length 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? • Yes ® No If Yes, permit number of 2nd treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? If No, complete and submit the VariancelAlternative ►rl Yes Design ■ No Request (VADC 10-14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. . FTA 10-14 APPLICATION PaaeS of 6 14: Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® NIA Sedimentation and Erosion Control Plan? ® Yes ❑ No 0 NIA Trout Buffer Waiver? ❑ Yes ❑ No ® N/A Stormwater? ® Yes 0 No 0 N/A 15. Does this project include any high priority lines (15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These Tines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details: C. CERTIFICATIONS 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Crystal Panico, attest that this application for Dhulab Medical Offices has been reviewed by me and is accurate and application are not completed and that application package is subject to being 143-215.6A and 143-215.68, any complete to the best of my knowledge. I understand that if all required parts of this if all required supporting documentation and attachments are not included, this returned as incomplete. Note: In accordance with North Carolina General Statutes person who knowingly makes any false statement, representation, or certification Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well violation. in any application shall be guilty of a as civil penalties up to $25,000 per 1a. 763/Iio//(p Sig n Offi 1 Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO SUBMITTAL OF THIS OF SEWERS, THEIR PROXIMITY TO 15A NCAC 02T .0305 2. Professional Engineers Certification: (Signature of Design Engineer and Project 1, Todd Born ,attest that this application for Dhulab Medical Offices has been Name) reviewed by me and is accurate, and all other supporting knowledge the proposed design has Design Criteria for Gravity Sewers Permitting of Pump Stations and Force Division guidance. Although other inclusion of these materials under my it to be consistent with the proposed any person who knowingly makes complete and consistent with the information documentation to the best of my knowledge. been prepared in accordance with the applicable adopted February 12, 1996, and the Minimum Mains adopted June 1, 2000 and the watershed professionals may have developed certain portions signature and seal signifies that 1 have reviewed design. Note: In accordance with NC General any false statement, representation, or certification include a tine not to exceed $10,000 as well as in the engineering plans, calculations, I further attest that to the best of my regulations, Gravity Sewer Minimum Design Criteria for.the Fast -Track classification in accordance with of this submittal package, this material and have judged Statutes 143-215.6A and 143-215.68 in any application shall be guilty of a Class 2 misdemeanor which may civil penalties up to $25,000 per violation. 2a. Todd Michael Born oµ1sUffB �.• �40, �N4 42P 40 SEAL E = i 35009 . • �T!- NO �% s�j„~HGi... it 1 �16 ',,''+��irm � + `' p�` NC PE Seal, Signature & Date Professional Engineer Name 2b. Site & Structure, p.c. Engineering Firm` 2c. 4719 Mortonhall Road Mailing Address 2d. Charlotte e. NC f. 28215 City State Zip 2g. (704) 573-7800 h. NIA ,2i. tbom@siteandstructure.com Telephone J Facsimile E-mail FTA 10-14 APPLICATION Page of6 Dhulab Site March 11, 2016 1:2, 210 0 0 0175 0.035 0 07 m f 1 t rJ 0 0 0275 0.055 {1.11 km &me s ESoli HERE. O€vlc7nnr. USGS, Inte'na+p, i.ra.°tPrnprd P Corp, NRCAN, Ean Japan ME 1. Esn Ctrina (Hong IKa. 1. Eeri (Thealar0), M m-10{1,1a, C)penSleatMap ccnntotors, 41d lr GIS. 'User (:nmrrraionly Dhulab Aerial March 11, 201E 1:2,210 i 00175 0 035 007mil G 0 0775 0,055 0 11 km nt2i? E,va Dicp latG1 e F:04- co; i,;tiKa€y mtvr.a" CNI"St rhos OS , ,11+1 US S AE X C,ckma{n)erry Few rXl n.i, RrrN I kr 'tY#S$IWp drat ti GI $ LISeh Corrrmeurrrty I"sn r+Fh£ Det: ,nr 'Mielrny100,,a *y.)1.1+ tr1rtvkalr State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Union County Project Name for which flow is being requested: Dhu.lab Medical Offices More than one FTSE ,no; be required for stations along the route of the proposed was kwat t° 1ot�? if"the owner of°the fiFT,P i.s not responsible for all pump I. Complete this section only if you are the owner of the wastewater treatment plant.. a. WWTP Facility Name: Twelve Mile WWTP b. WWTP Facility Pertnit : k: NC0085359 c. WWTP facility's permitted .flow 4li flows are in MGD 6.0 d. Estimated obligated flow not yet tributary to the WWTP 1.7172 e. WWTP facility's actual avg. flow 4,08 :f. Total flow for this specific request 0.0020 g. Total actual and obligated flows to the, facility 5.7992 h. Percent of permitted flow used 96.65 Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between. the project connection point and the WWTP: (A) Design Pump Average Daily Station Firm Flow** (Name or Capacity,* (Firm ? pf). Number) MGD MGD 02.887 (B) Approx. Current Avg. Daily Flow, MGD 0.763 (C) (D)=(B+C) (E)=(A-I)) Obligated, Not Yet Total Current Tributary Flaw Plus Daily Flow., Obligated Available MGD Flow Capacity*** 0.1841 0.9471 0.2079 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm, capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the .Available Capacity is < {1. Page 1, FTSE 08-13 rIII. Certif cation Statement: I Crystal O. Panico certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. arhe &.,. (Pd.44,;(A9 Signii(g Oftici 1 Signature ,3if(0//6. Date Page 2 of 3 FTSE 08-13 FTSE PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and MGD of the Available Capacity (E) in Pump Station and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 of,3 FTSE 08-13 SITE & STRUCTURE P.C. Engineering • Design • Project Management March "11, 2016 LTR-S15002-002 Crystal Panico, PE Union County Public Works New Development Program Manager 500 N. Main Street, Suite 400 Monroe, NC 28112 Ms, Panico: Subject: Cover Letter for Sanitary Sewer Main Extension Project Name: Dhulab Medical Offices Indian Trail -Fairview Road Indian Trail, NC 28079 The purpose of this letter is to provide a brief project narrative for the sanitary sewer main extension for the project listed in the subject heading above. The project consists of an approximate 380-foot gravity sanitary sewer main extension to serve (2) new medical office buildings. The gravity sanitary sewer main extension will be constructed with 8-inch diameter SDR 35 pipe and will include installing (4) new precast concrete manholes. The development will create 2,€ 00 Gallons Per Day of new wastewater flow. We request the approval of the proposed plans by Union County Public Works and NCDENR Division of Water Resources and a notice to construct be issued. Thank you for your consideration and if you have any questions please don't hesitate to call. Best regards, Todd M. Born, P.E. 4719 Mortonhali Road • Charlotte, NC Phone: (704) 573-7800 • Fax: (704) 573-780 Email thomc@siteandstructure.com UNION COUNTY PUBLIC WORKS 500 N, Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Dhulab Medical Offices We are sending you: 0 Copy of letter El Plans Other Date No. Description over Letter Fast Track Application TRANSMITTAL Date: 3/16/16 Prints 0 Shop Drawings Copy of Fast Track Application Flow Tracking Form $480,00 Check (Application Fee These are transmitted as checked below: For approval 0 For your use 0 As requested 0 For review and comments Remarks: Signed: Received by: Date: Central Files: APS _ SWP 4/1/2016 Permit Number WQ0038371 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry.love Coastal SWRuIe Permitted Flow 2,000 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Dhulab Medical Offices Location Address Owner MajorlMinor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Union County DateslEvents Owner Type Government - County Owner Affiliation Cindy Coto 500 N Main St Monroe NC 28112 Orig Issue 4/1/2016 App Received Draft Initiated 3/23/2016 Scheduled Issuance Public Notice Issue Effective Expiration 4/1/2016 4/1/2016 Regulated Activities Requested !Received Events Office Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin Water Resources Environmental Quality February 16, 2017 Ms. Crystal Panico, New Development Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification Acknowledgement Project: Dhulab Medical Offices Permit No. WQ0038371 Permittee: Union County Public Works County: Union Dear Ms. Panico: � r f ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on February 15, 2017. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://portal.ncdenr.orglweb/wg/swp/ps/es/pnoc from the Collection, Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr. Todd M. Born, P.E., (Site & Structure, p.c., 4719 Mortonhall Road, Charlotte, NC 28215) Central Files — Nothing Compares—. State of North Carolina I Environmental Quality 1 Water Resources 1 Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue. Suite 3011 Mooresville, North Carolina 28115 704-663-1699 FAST TRACI( SEWER ENGINE N(4 CERTIFICATION PERMITTU : union County Public Works f'CRM1711: WQ0038371 R UIt C`t; Dhulab tv edIcal Offices ISSUE DATE,: April 1, 2016 This proj err the Re sltiered complete nor allowed to operate ita accrrlar ce with Condition 7 of Division has received this Certification and all required supporting documentation. It in a manner that documents the Division s receipt. Send the required documentation Water Quality Regtonal Operations Section ,at the address at the bottom. Any wastewater flow made tributary to tare to astewater' coliectiorl system extension prior to compl of this Certification shall be considered a via latirTrt rrf tine perlaait and slaail sttltjec;t the ferrnittee to appropriate enforcement actions, The Permittee 1s hesponsii)ie for tracking all lraatiei ertlficatitns rtp until a final certification is received, A Final Certification shall be a complete set o� design alculalions regardless of whether partials have been submitted, TTIFICAT€ON I, the rind ersigt)erl agent for the Permittee, hereby state that this paoject has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction infortrration to the Permittee, and the Permittee is prepared to operate & maintain t permitted freit`t or portirans thereof, N IN €9S CERTIFICM O Nott'h Carolina, having bd to observe �periaydically, ! weekly, frtil titaae) tf e construction of the project name anri faction as referenced above for the above Perm i tree hereby state that, to the best, of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to he built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996.., as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mnlns adopted June 1, 2000, as applicable; and other supporting materials, North Cat (44.•,M, as a rioi register d Professitart e L=rnginee's Seal w/signature & date: de description) Comments/Quafiflersattach if necessary). SarrenS'NoishC.'aroiieaV6Yar an;eurnlQiniray{r,VaierRnouates1WierQuality Iltgi©nalopelmions ".arr.Pssi4�� Rc lasol1 Ofl:cel,bl{iEly Cenler rlvknue, Soilc 101 11,1coreiville. h:orkh Carolina ,Z61 15 r040'316771