Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037853_Regional Office Historical File Pre 2018
Pat McCrory Governor North Carolina Department of Environmental Quality October 26, 2015 William Grant, P.E. CIP Program Manager Union County Department of Public Works 500 North Main Street, Suite 500 Monroe, North Carolina 28112 Subject: Rescission of Wastewater Collection System Extension DWQ Permit No. WQ0037853; Murphy USA Indian Trail Union County Dear Mr. Grant: Donald R. van der Vaart Secretary Reference is made to your request for rescission of the subject Wastewater Collection System Extension Permit, received by the Division on October 22, 2015. The proposed gravity sewer will not be constructed. Therefore, in accordance with your request, Wastewater Collection System Extension Permit No. WQ0037853 dated June 11, 2015 is rescinded, effective immediately. If in the future, you determine that you need another wastewater collection system extension permit, you must first apply for and receive a new Wastewater Collection System Extension permit. Construction and operation of a wastewater collection system without a valid Wastewater Collection System Extension Permit will subject Union County to a civil penalty of up to $25,000 per day. If you have any further concerns, please do not hesitate to contact me in the Central Office at 919- 807-6383 or via email [Deborah.Gore@ncdenr.gov}. Sincerely, tti ' jic,5 Deborah Gore PERCS Unit Supervisor cc: Central Files WQ0037853 MRO (electronic copy) PERCS Permit File 1601 Mall Service Center, Raleigh, North Carolina 27699-1601 Phone: 919-707-8600 l Internet: www.ncdenr,gov An Equal Opportunity 4 Affirmative Action Employer— Made in past by recycled paper UNION COUNTY DEPARTMENT OF PUBLIC WORKS RECE1VtDRLCDEWRJDWR PCT. 2 2 -i0)b wQkoss 500 North Main Street, Suite 500, Monroe, NC 2S �f2ESVILLF REGIONAL, QFF.�CE' Phone (704)296"",4210 • Fax: (704)296-4232 _ . October 19, 2015• NC Dept. of Environment and Natural Resources Mooresville Regional_ Office 610 E. Center Avenue Mooresville, N.C. •28115 Ref: Murphy USA Indian Trail — Permit # WQ0037853, dated June 11, 2015 To whom it may concern: Please void permit # WQ0037853, dated June 11, 2015. The proposed gravity sewermain will not be constructed as approved with this permit. There will be a private permit with a private pump station. If you have any questions don't hesitate to call me at (704) 296-4239. Thankyouu for working with us on this matter. Sincerely, William Grant, P.E. CIP Program Manager • WG/pwb North Carolina Depart Pat McCrory Governor R ent of Environmen June 11, 2015 Mr. Charles P. ©'Cain, Development Program Manager Union County Public Works 500 N. Main Street, Suite 500 Monroe, NC 28112 Subject; Permit No. WQ0037853 Murphy USA Indian Trail Wastewater Collection System Extension Permit Union County Dear Mr. O'Cain: nd Natural Resources Donald R, van der Vaart Secretary In accordance with your application received June 10, 2015, we are forwarding herewith Permit No. WQ0037853 dated June 11, 2015, to Union County Public Works (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11,1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T ,0403 or any individual system -wide collection system permit issued to the Permittee. it shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with. North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding, Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Phone; 704-663-1699 \ Fax 704-663-6040 \ Customer Service 1-877-623-6748 Internet: www.ncwateroualitv.org An Equal Opportunity \ Affirmative Action Employer — Made in part by recycled paper Union County Public Works Permit No. WQ0037853 If you need additional information concerning this matter, please contact Barry Love at (704) 23S 2143 or via e-mail at barry.love@ncdenr.gov, for S. Jay Zimmerman, Director Division of Water Resources, NCDENR by Michael Parker, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDENR cc: John Nourzad, P.E. (electronic copy) Regional Office Files Water Resources Central Files PERCS (electronic copy) Page 2 of 8 ATA IThENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Union County Public Works Union County for the construction and operation of approximately 579.74 linear feet of 8-inch gravity sewer to serve a convenience store as part of the Murphy USA Indian Trail project, and the discharge of 1500 gallons per day of collected domestic wastewater into the Union County Public Works existing sewerage system, pursuant to the application received June 10, 2015, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the 'fled conditions and limitations contained therein. for S. Jay Zimmerman, Director Division of Water Resources, NCDENR By Authority of The Environmental Management Commission Permit Number: WQ0037853 Permit Issued: June 11, 2015 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Union County Public Works is hereby authorized t©: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Union County Crooked Creek Wastewater Treatment Plant in accordance with Permit Number NC0069841. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below, SPECIAL CONDITIONS No flow in excess of the quantity permitted herein, 1,500 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T.0304(b)] II, STANDARD CONDITIONS This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a forrnal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. (15A NCAC 02T.0104; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 1SA NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 115A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: Page 4 of 8 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system fromother public and private satellite sewer systems_ 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143- 215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush law points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be dearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an . enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T.0104; 15A NCAC 02T .0108(b-c)] 11. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. (15A NCAC 02T .0110; 15A NCAC 02T .0108(6)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Union County Public Works WQ0037853 Murphy USA Indian Trail June 11, 2015 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this. Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe (11 periodically, ri weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 1SA NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Q Final J Partial (include description) Certification Comments/ u ers attach if necessary): NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, ilooresville,, NC 28115 nY, . _ R-ern al r^ fl w r-rtre. runt, f'Y ft «i4 r*h'Y e."1th • USE THE TAB KEY TO MOVE FROM FIELD TO FIELD 1 Owner/Permittee: la. Union County Full Legal Name (company, municipality, HOA, utility, etc 1b, Charles P. O'cain (Development Program Managejr Signing Official Name and Title (Please review 15A NCAC 2T .0 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality Q ld. 500 North Main Street Suite 500 LL Mailing Address 1f. North Carolina State Q 1h. 704-296-4244 z 0 2 0 LL. Z Application Number (to be completed by DWR) 06_1b1 for authorized signing officials) ate/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): le. Monroe City 1g, 28112 Zip Code 704-296-4232 Telephone Facsimile 2. Project (Facility) Infortrtltion: 2a. Murphy USA Indian Trail Brief Project Name (permit 3. Contact Person: 3a. Charles P. O'Cain Name and Affiliation of So 3b. 704-296-4244 o this name ocain E-ma 2b. Union 1VF17,NCDFfll co.union,nc.us MOORFSViLLF REC7l(1NAL O(=ME. County Where Project is Located one Who Can Answer Questions About this Application Phone Number Project is New 0 Modification of an ex 2. Owner is ® Public (skip to Item B(3)) 3c. ocain E-mai union.nc.us ing permiodiifiication, Permit No,: ❑ Private (go to Item 2(a)) If private, applicant will be: ❑ Retaining Ownership (i.e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Union County Owner of Wastewater Treatment. Facility (WWTF 4a. Crooked Creek Name of WWTF 5a. Union County 5b. 8 inch Gravity Owner of Downstream Sewer Receiving Sewer Size 0 Force Main 6. The origin of this wastewater is (check all that apply): 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction D) 0 Homeowner Assoc./Developer (Instruction E) tewater From This Project 4b. NC0069841 ❑ Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park Q School ❑ Restaurant ❑ Office WW'TF Permit No. WQ0024885 Permit # of Downstream Sewer (instruction F) Retail (Stores, shopping centers) ❑ Institution 0 Hospital El Church ❑ Nursing Home ❑ Other (specify): Volume of wastewater to be allocated or permitted for this particular project: 1500 *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 100% Domestic/Commercial % Industrial (Attach Descript % Other (Attach Descriratton gallons per day ion) ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T ,0303 to determine if a permit is required) IF —A 10-1 PPLIICA`t`IO\ 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). (2) Hand Sink; (1) Three compartment sink; (1) Mop sink; (1) Water closet; (1) Lavatory Total Plumbing Fixtures = 6 Flow Rate = 250 GPD/Plumbing Fixture Total Wastewater Flow Rate = 6 x250 = 1500 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 r ❑ Length (feet) New Gravity or Additional Force Main 579.74 New Gravity W -- — It Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID: (self chosen - as shown on plans/map for reference) 0 Z 0 et 2 0 I1 Z 1-- 2 a_ Longitude: Latitude: - Design Flow Operational Point Power Reliability Option (MGD) GPM @TDH i - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w!MTS E 'Pump Station Location ID: (self chosen - as shown on planslmap for reference) ,Longitude: Latitude: Design Flow (MGD) ' 1 Power Reliability Option Operational Point'1 - permanent generator w/ATS; GPM @TDH I 2 - portable generator wIMTS Force Main Size Force Main Length 112. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No if Yes, permit number of 2nd treatment facility : (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request (VADC 10-14) application and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. PTA 10-I4 APPLICATION Page 5 of " 14, Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Strearn Crossings - General Permit or 401Certification? El Yes 0 No El N/A Sedimentation and Erosion Control Plan? 0 Yes 0 No EJ N/A Trout Buffer Waiver? 0 Yes Li No IE N/A Stormwater? 0 Yes El No 0 N/A 15. Does this project include any high priority fines (15A NCAC 2T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once evervsx months Check if Yes: 0 and provide details: 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Charles P. O'Cain, attest that this application for Murphy USA Indian Trail has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supportingdocumentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143: 215 68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, la, Signing 0 nature - / Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY (I) TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 0 2. Professional Engineer's Certification (Signature of Design Engineer and Project Name) John Nourzad, attest that This application for Murphy USA Indian Trail has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and alt other supporting documentation to the best of my knowledge, 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143:215AB, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, Nourzad Professional Engineer Narne 2b. Greenbergyarrow Engineering Firm 2c, 14 0 West Peachtree Street, NW Ming Address 2d, Atlanta 2e, GA 2f, 30309 City State Zip 2g, 404-601-4000 2h, 404-601-3990 2i, Telephone jnourzadeg eenbergfarrow,co Facsimile NC PE Seal, Signature & Date IA -14 APP1. ICA HON Page 6 016 pOlge URPHY OIL USA, INC. MUAPH .200 PEACH STREET P.O BOX 7000 i .. EL DORADO, AR 71750-70Q0 17 ,. IJ Diviston of Water Resources State of North Carolina Department of Environment and Natural Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 08-13) Project Applicant Name: Union County Project Name for which flow is being requested: Murphy USA Indian Trail More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Crooked Creek b. WWTP Facility Permit #: NC0069841 All flows are in MGD c. WWTP facility's permitted flow 1.90 d. Estimated obligated flow not yet tributary to the WWTP 0.4378 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.20 0.0015 1.6393 86.28 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) 'Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow PIus (Name or Capacity,* (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** N/A * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page 1 of 6 FTSE 08-13 III. Certification Statement: I Charles P. [)'Cain certify to the hest of my knowledge that the addition of the volume of wastewater to he permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendurns for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Page 2<f 6 pr FTSE PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 of 6 FTSE 08-13 Gree be r Ferrol Cover Letter June 1, 2015 To Union County Public Works 500 N. Main Street Monroe, NC 28112 NCDENR Division of Water Resources 610 E. Center Avenue Mooresville, NC 28115 704-663-1699 ProjecC Project # From Re iVFDlr c,DE': WE, ROS H (31 1NAL OEFI(F. 1430 VVest PeacritsRe St,'ee7'1, NW Some 200 AiBanta,. GA 3030° t: 404. 601 4000 f: 404 601 3970 AT AM1A NEW ifRile' N4:4 YOR,4 r4 NO 'Wk$CONSfN EENTONV:Lit. SNMNCiMAS MEPCCI x". rr'd Murphy — Indian Trail, NC 2©140317.0 Greg Sistrunk Fast Track Sewer Application 1 Overview Murphy Oil USA, Inc. is proposing a commercial development located in Indian Trail® NC which will consist of a 1,2t1 square foot convenience store (1 unisex restroom), 4 gasoline pumps and associated parking, utilities and landscaping. The Murphy site shall be located on a 1,21 acre parcel and access to the site shall be provided from an adjacent access drive off Novivian Lane. Wastewater Wastewater from the property shall be served by a proposed 8-inch gravity sewer line extension. The proposed sewer main shall run from the Murphy site toward an existing sanitary line located near the northwest corner of the property owned by Walmart Real Estate Business Trust, A portion of the existing gravity sewer line is currently private„ but it will be dedicated to UCPW with this permit, The wastewater flow calculations are as follows: Total Plumbing Fixtures = 6 Flow Rate = 250 GPD/Plumbing Fixture Total Wastewater Flow Rate: 6 x 250 = 1,500 GPD. 01 Mere,aam,urnD?.04t5,,',cra4nbet'gf rov.Pr(r COY er env' doo. '201403 03,1C00 Per3mt kkprrSv,'N ExXX4,X xre °,a COW Plmis3r<r =etwar ,Artp UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Murphy USA Indian Trail We are sending you: E] Copy of letter Plans 0 Prints 0 Shop Drawings Z Other TRANSMITTAL RECE VEDfNCDr NR!DWR WO RCS IMC)ORESVfL E REGIONAL OFFK::E: Copies f Date 1 1111 6 1 1 6/8/15 No. Description Cover Letter Fast Track Application 6/8/15 Copy of Fast Track Application 6/8/15 5/14/15 i 047924 Flow Tracking Form 489.09 Check (Application Fee These are transrnitted as checked below:: Date: 6/9/15 For approval I J For your use [ As requested 0 For review and comments Remarks: Received by: Date: " Central Files: APS _ SWP 6/11/2015 Permit Number - - WQ0037853 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer barry,love Coastal SWRuie Permitted Flow 1,500 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Murphy USA Indian Trail Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Government - County Owner Affiliation Cindy Coto DateslEvents 500 N Main St Monroe NC 28112 Orlg Issue 6/11/2015 App Received Draft Initiated 6/10/2015 Scheduled Issuance Public Notice Issue Effective 6/11/2015 6/11/2015 Regulated Activities Requested /Received Events Retail Wastewater collection Outfall Expiration Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin