Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037297_Regional Office Historical File Pre 2018
NCDENR North Carolina Department of Environment and Natura Pat McCrory Governor Mr. Charles P. t:i"Cain, PE LJn.ion County Public. "works 500 North Main Street, Suite 500 Monroe, N.C. 281.12 Subject: Septembe Permit No. W0003,7297 Geoff flawk Sewer Service Wastewater Collection. System Extension Union County ➢. ear Mr. (]'Cain: 2t`i4 Resources John E. Skvarla, 111 Secretary ce with your application reeAugust 1.4, 2014, we are ft r vardin laerew'itla to l ermit No. Wi 0037297, dated. September 5, 201.4., to the Union County Public Works for the construction and operation of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall he considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the followitag conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A. NCA.0 2T .0403 or any individual system -wide collection system permit issued to the ;Permittee. It shall he responsibility of the Unto n County Public Works to ensure that the as constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities,. and'or referral of the North Carolina -licensed Professional Engineer to the licensing board. if any Harts, requirements, err lirrtitations containe request ata. adjudicatory hearing upon written request request must he in the form of a written petition, con Statutes, and filed with the Office of Administrative 27699-6714. Unless such demands are. made, this permi Moores vr!le FegiorF permit are unacceptable, you harp e the right to in 30 days following receipt of'this permit. This g to Chapter 15011 of North Carolina General ings, 6714 Mail Service Center, Raleigh, NC hall be final and binding. lt1 F_as! Center Avenue, Mooresv lte, rlruir h 0 714-663-1699\ tniernet: wwwircdenr!Jov Air Equ [ f' v, Union County Public Works WQ003/297 If you need additional information conceming this matter, please contact Michael Parker at (704) 663- 1699 or via e-mail at Michael.Parker@ncdenr.gov. for Thomas A. Reeder Division of Water Resources by Michael Parker Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Cc: Mooresville Regional Office C. Matthew Jones, PE (e-copy) Water Resources Central Files PERCS ATA FbENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Union County Public Works Union County for the construction and operation of approximately 132 linear feet of 8-inch gravity sewer for the Geoff Hawk Sewer Service project and the discharge of 285 gallons per day of collected domestic wastewater into the Twelve Mile Creek Treatment Facility existing sewerage system, pursuant to the application received August 14, 2014, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June I, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. it issued this 5th day of September, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ003 7297 SUPPLEMENT TO PERMIT COVER SHEET Union County Public Works is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Twelve Mile Creek Wastewater Treatment Facility (NC0085359) prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the following Conditions. I. SPECIAL CONDITIONS 1. No flow in excess of the quantity permitted herein, 285 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Resources. II. STANDARD CONDITIONS 1. This permit is not transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February I2, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g- Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i- Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. J• Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number 704 663 -1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Per 15A NCAC 2T.0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. c_ Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe Iength increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 8. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 12. The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST TRACK ENGINEERING CERTIFICATION Permittee: Union County Public Works Permit No. WQ0037297 Project: Geoff Hawk Sewer Service — Union County issue Date: 9/5/2014 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION I, , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. . Printed Name, Title Signature Date ENGINEER'S CERTIFICATION ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 DWR Use Only: Flow from this project is tributary to: z 0 Application Number: USE THE TAB KEY TO MOVE FROM HELD TO HELD (to be completed by DWH) / /. Owner/Permittee: la, Union County Public Works Full Legal Name (company, niunicipality, HOA, utijtty, etc. lb, Charles P. O'Cain, P.E. - Development m Maria Signing Official Name and Title (Please review for authorized signing ol c. The legal entity who will own this system is: Individual D Federal El Municipality ce O ld. 500 N. Main Street, Suite 500 U.. Mailing Address • if NC z O 704 ia ate/County EI Private Partnership Corporation ED Other (specify). le. Monroe - J 11. EL State 296-4244 i, (704) 296-4232 Telephone Facsimile 2. Protect (Facilitv) Information: 2a. Geoff Hawk Sewer Service Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Charles (nein, P.E. Name and Affiliation of Someone Who Can Answer Questions Ab City lg. 28112 Zip Code 1j. ocainJcounion.nc.us E-mail 2b. Union 3b, (704) 296-4244 Phone Number 1„ Project is New El Modification (of an existing permit) County Where Project is Located this Application 3c. ocain@co.union.nc.us E-mail If Modification, Permit No., 2, Owner is Public (skip to ltem B(3)) E] Private (go to item 2(a)) 2a, If private, applicant will be. 11] Retaining Ownership (i.e. store, church, single office, etc,) or Leasing units (lots, townhomes, etc - skip to item B(3)) D Selling units (lots, townhomes„ etc - go to Item B(2b)) 2b If sold, facilities owned by a (must choose one) Public Utility (Instruction D) El Homeowner Assoc./Developer (Instruction E) Z 3, Union County Public Works 0 Owner of Wastewater Treatment Facility (WNTF) Treating Wastewater From This Project 4a. Twelve Mile Creek 4b. NC0085359 Name of WWTF WWTF Permit No. IX 5a Union County ____il5b. 12-inch 1 Gravity . WQ0006421 0 Owner of Downstream Sewer Receiving Sewer Size !LI Force Main : Permit # of Downstream Sewer (Matrix i Z ▪ 6. The origin of this wastewater is (check all that apply): Residential Subdivision Apartments/Condominiums E..] Mobile Home Park o school El Restaurant O Office Retail (Stores, shopping centers) Ej Institution Hospital ID Church o Nursing Home o Other (specify) % Domestic/Commercial % Industrial (Attach Desciiption) % Other (Attach Description) 7„ Volume of wastewater to be allocated or permitted for this particular project: 285 gallons per day *Do not include future flows or previously permitted allocations 8, If the permitted flow is zero, indicate why: o Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line D Flow has already been allocated in Permit No.. D Rehabilitation or replacement of existing sewer with no new flow expected (see MA NCAC 0-21 0303 to determine if a permit is required) FTA 08-13 APPLICATION Page 3 of 6 H Z 0 Pump Station Location ID: (self chosen - as shown on plans/map for reference) Longitude: Design Flow (MGD) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (t). 95 GPD (per bedroom) x 3 Bedrooms (in residence) = 285 GPD, total 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 111 Length (feet) ' New Gravity or Additional Force Main 132 New Gravity z 0 0 LL Pump Station Location ID: 1-- 2 Longitude: W Design Flow 0-(MGD) 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Latitude: Operational Point Power Reliability Option ' GPM @TDH 1 - permanent generator wIATS; ' Force Main Size Force Main Length 2 - portable generator w!MTS Latitude: (self chosen - as shown on plans/map for reference) Operational Point Power Reliability Option GPM @TDH ! 1 - permanent generator wlATS; Force Main Size Force Main Length 2 - portable generator w!MTS 12. Will the wastewater flow in the proposed sewer fines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility : (RO — if "yes' to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 08-13 APPLICATION Page 4 of 6 14. Have the following permits/certifications been submitted for approval for the system or project to be served? ' Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Trout Buffer Waiver? Stormwater? ❑ Yes ❑ No ❑ Yes ❑ No 0 N/A ❑ Yes ❑ No ® NIA ❑ Yes ❑ No ® N/A N/A 15. Does this project include any high priority lines (15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details: C. CERTIFICATIONS 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Charles P. O'Cain, P.E. , attest that this application for Geoff Hawk Sewer Service has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if al! required parts of this application are not completed and that if all required supporting documentation and attachments are not } included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement; representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $ ,000 per violation. 11 a. ���C --� i ° Signing icial Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, C. Matthew Jones, P.E. ,attest that this application for Geoff Hawk Sewer Service has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 1. 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that have reviewed this material and have judged !t to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. i 2a. C. MatthewJones, P.E Professional Engineer Name 2b. Jones Civil Design, P.C. Engineering Firm 20. 334 Sandymead Road Mailing Address 2d. Matthews2e. NC , 28105 f. City State ; Zip 2g. (704) 412-8523 '2h. N/A 2i. Matt@JonesCivilDesign.com Telephone Facsimile E-mail ,lltit1Irrr+rl ll CA 0• NC PE Seal, Signature & Date FTA 08-13 APPLICATION Page 5 of 6 CA 090*0,00 JONES CIVIL` DESIGN, P.C. C-3859 J O N E s 3M34ATTHSA, NC 10A .NL3ND NC 285 CIVIL DESIGN www.J©nesCivHDesign,com PH: (704) 412-8523 HAWK PROPERTY 3909 FINCHER ROAD MATTHEWS, NC 28104 U.S.G.S. EXHIBIT Ito 620 alleys than25, Departme Flow TrackinglAcceptanc State of North of 1 n ironment and Natural Resour Division of Water Resources for Sewer Extension Applications (FTSE 08-13) oject Applicant Name: Union County Project Name for Which flow is being requested: GeofT Hawk Sewer Service More than one FTSE may be required, for a single project if`lh c wner o stations along the route of the proposed wastewater_ flow ,t'TP is not responsible. for all,jmrnp I. Complete this section only if you are the owner of the waste a. WWTP Facility Nance: Twelve Mile WW1 P b. WWTP Facility Permit : NC0085359 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tt e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used Water treatment plant. Allflows 6.0 utary tc the WWTP 1.7427 .37 0.0003 l Complete this section for each pump station you are responsible e for along proposed wastewater List pump stations located between the projec Pump Station (Marne or Number) N/A Firm Capacity,* MG D (A) Design Average Daily Flow** (Firm / pt), MGD onnection point and the WWTP: (8) Approx. Current Avg. Daily Flow, MGD he Fir trt C p tt fo arty pump station is� as can be achieved with the largest pump taken out, of **Design A t'erage Daily Flow is the...grin capacity of t' the AlffeffiJt/, d e,hllfih//be atla* de (C) Obligated, Not 'Yet Tributary Daily Flow, MGD re in GD ou. Total Current Flow Plus ONiigated Flow o: is IIi. Certification Statement: I Charles P. ()'Cain certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the Clow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable, This analysis has been performed in accordance with local established policies and procedures using the best available data.. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this foram indicates acceptance of this wastewater flow. rig t a 'i " criure .Date Page �s _ ` t' FORM WSCAS 08-13 WATERSHED CLASSIFICATION All ACHN 'NT FOR SEWER SYSTEMS Applicant Nam ffr y Hawk Prafessionai EngineerN C. Matthew Jones, P,E, Location ID ProName Geoff Hawk Sewer Service Engrneering Firm Name Jones CMI Oesign, P.C. River Waterbody Waterbody Name of Waterbody CountStream Index No, Basin Classification Davis Mine Creek Union Catawba 11-138-2-2-1C I unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary loins, I certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and That the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief PE Seal, Signature and Date *** END OF FORM WSCAS 08-13*** FORM: WSCAS 08-13 Page 1 T . WQO( 4/ J©NES CIVIL DESIGN, P.C. C-3859 O� MEA0 ROAD ATTHE�WS,334 r NC28105 DESIGN www.J4nesCivilDeaign.cam PH: (704) 412-8523 HAWK PROPERTY 3909 FINCHER ROAD MATTHEWS, NC 28104 U.S.G.S. EXHIBIT UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve Geoff Hawk - 3909 Fincher Road We are sending you: D Copy of letter L Plans Other 8/8/14 8/12/14 8/12/14 No, Description Cover Letter Fast Track Application Date: 8/13/14 Prints Li Shop Drawings Copy of Fast Track Application Flow Tracking Form 4046 i $480.00 Check (Application Fee Stream Classification Form These are transmitted as checked below: For approval fl For your use 0 As requested Q For review and comments Remarks: Signed: Received by: Date: IVES . ESIG. fYgtityfran-Ovgnedff August 8, 2014 Civil Engineering! Land Solutions 'From concesawn to Completion" Division of axes Resources State of North Carolina Department of Enviroll m en t a Natural Resources R. Geoff Hawk Sewer Service 3909 Finches Road, Matthews, NC 28104 To homi 334,Sandymead Road ...Matthews, NC 28105 1204) 412085.23 This project proposes to extend an 8" gravity sanitatiy sewer line 132 L.F. to sente a single-family residence, Al part of this project, a tap will be made into an existing, downstream manhole to accommodate die sewer line extension. 'Then, at the termination of the sewer line extension, a new manhole will be installed with ontubout for a 4” sewer lateral to the residence. Currently, there are no plans to SUbd iVide this project or to serve any additional twines, Ye d this sewer line will be turned over to Linion County Public Works for future use, Trtainttmance, revision, or extension as the County deems necessary, (Sordially, fdy 8,1atthew Jones, P12 President Principal Engineer jONES t DESIGN, raggiss, a" • ' 49 .41A 441' /.11.t.t Page I Central Files: APS _ SWP 9/5/2014 Permit Number WQ0037297 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael.parker Coastal SWRule Permitted Flow 285 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Geoff Hawk Sewer Service Location Address Owner MajorlMinor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Government -County Owner Affiliation Mike Garbark 500 N Main St Dates/Events Monroe NC 28112480 Orlg Issue 9/5/2014 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/4/2014 9/5/2014 9/5/2014 Regulated Activities Requested /Received Events Subdivision Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamlndex Number Current Class Subbasin pri1.7.7 . Water Resources ENVIRONMENTAL QUALITY September 22, 2016 Ms. Crystal Panico, New Development Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification Acknowledgement Project: Geoff Hawk Sewer Service Permit No. WQ0037297 Permittee: Union County Public Works County: Union Dear Ms. Panico: PAT MCCRORY Governor DONALD R. VAN DER VAART serreraty S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on September 19, 2016. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http:l/portal.ncdenr.orglweb/wg/swp/ps/cs/pnoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr. Curtis Matthew Jones, P.E., (Jones Civil Design, 7825 Vinings Oak Lane, Unit #918, Matthews, NC 28105 ) Central Files MRO State of North Carolina 1 Environmental Quality I water Resources 610 E. Center Avenue, Suite 301, Maoresville, NC 28115 Phone: 704-663-16991 Internet: www.ncdenr.gov REt '2RitZtiVCD:7NR!DWR FAST TRACK ENGINEERING CERTIFICATION WQR0s. Pertnittee: Union County Public Works Permit No, WQ0037297 Project: Geoff Hawk Sewer Service * Union Countlit00147SVitLrFiscitoNL4,totzpicE Issue Date: 9/5/2014. Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension, Final record drawings should be clear on the plans or on digital media (CD or IND disk) in pdf format, Record drawings should indicate the design, and the marked up changes during constructiotu Supporting design calculations (selected pumps, system CUrVe, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary .form. Perniit ioifcafionse rcquiretl for any In resuItiig non-cornp1ince with his nerrnil regulation, design criteria.Modifications s n. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation.. Therefore, it isjjjh1v rero nikde • this certification be sent in a manner that ovide roofofreceipl by the Division. PERWTTEE'S CERTIFICATION , the undersigned agent for the Permittee, hereby state that this project has been emistructed pursuant to the applicable standards & requirements„ the Professional Engineer below has provided applicable design/construction inforination to the Permittee, and the Permit -tee is prepared. to operate & maintain the wastewater collection system permitted her -in or portions thereof, /AA) Da/a lirt-gt4;W Printed Name, Title ENGINEER'S CERTIFICATION Partial [5 Final Curtis Matthew Jones as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, r] weekly, 71 fill" time) the construction of the subject project for the Permittee hereby state that, to the hest of my abilities, due care and diligence was used in the observation of the construction such that the construction seas observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996,.as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, ?ot)0, as applicable; and other supporting materials. Date North Carolina Professional Engineer's Seal, signature, and date: C WITH RE SEA. 0.3 4935 " Yo /ZOO MVP, Hs On!y: nowfroffi Litis pa" q:( i lribut.avy SEND THIS FORM & SUPPORTING DOCUMENTATION '.11RED ATTACHMENTS TO THE FOLLOWING ADDRESS DIVISION OF WATER RESOURCES WATER QUALITY REGIONAL OPERATIONS SECTION MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, surrE 301 MOORESVILLE, NC 28115 C UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N,C. 28115 Attention: Regarding: Sanitary Sewer to serve 3909 Fincher Road We are sending you: Copies 1 Date 1 Copy of letter Other Description q Plans TRANSMITTAL Date: 9/14/16 0 Prints Shop Drawings 3909 Fincher Road Final Asbuilts 909 Fincher Road Fast Track. Ce These are transmitted as checked below: E For approval For your use 0 As requested LI For review and comments Remarks: Thanks and take care, Signed: Received by: Date: