HomeMy WebLinkAbout540130_Inpsection 2021_20211116Facilit Number
()
is Division of Water Resources
a Division of Snit and Water Conservation
0 Other ,lgenc►
Compliance Inspection Operation Review Q structure Evaluation 0[Minkel Atisistnnce
Reason for Visit: ejj
•Routine 0 Complaint 0 Fellow -up 0 Referral 0ErnereencL 0 Other Denied Access
Region:L. -
C+
County
Fype of Visit:
Date of Visit: L►)—\1 I Arrival Time:
Farm Name: 9; ittC��
Departure Time:
Owner Email:
Owner Name: rU C< . KaYIAZdjA Phone: Mailing Address: 1:35 (Ice VIL • S'Dicril Lj c; ,s~,I1 k)C
Physical Address:
Facility Contact: r o \ Y 1 Title:
Onsite Representative: ("CO0 •
Certified Operator:
Back-up Operator:
Location of Farm:
Latitude:
Phone:
Certification Number:
Certification Number:
Longitude:
Integrator:
Swine
Design Current
C':ap:tcit►• Pop.
Wean to Finish
Wean to Feeder
Feeder to Finish
g
Farrow to Wean
}arrow to Feeder
Farrow to Finish
Cailts
Boars
Other
Design Current
Wet poultry Capacity. Pop.
slyer
Design Current
Cottle
Design Current
Capacity Pop.
Dairy Cow
Dairy Calf
Dairy Heifer
Dry Cow
Non -Dairy
Beef Stocker
Beef Feeder
Beef Brood Cow
Ilir charge~ and Stream Impacts
I. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other:
a, Was the conveyance man -trade?
b. Did the discharge reach waters of the State? Of yes, notify DWR.)
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does the discharge bypass the waste management system? (If yes, notify DWR)
2. Is there evidence of a past discharge from any part of the operation?
3. Were there any observable adverse impacts or potential adverse impacts to the waters
of the State other than from a discharge?
Page 1 of 3
❑ Yes El/No ❑ NA ❑ NE
❑ Yes El No ❑NA ❑NE
❑ Yes ❑No ❑NA El NE
O Yes QNo
❑ Yes [l' No
❑ Yes ErNo
[l NE
❑ NE
❑ \L
S/J2/2020 Continued
Waste Collection & Treatment
4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate?
a, If yes, is waste level into the structural freeboard?
Structure ! Structure 2 Structure 3 Structure 4
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
5_ Are there any immediate threats to the integrity of any of the structures observed?
(i.e., large trees. severe erosion, seepage, etc.)
6_ Are there structures on -site which are not properly addressed and/or managed through a
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an Immediate public health or environmental threat, notify DWR
❑No El NA El NE
❑ NA ❑ NE
❑ NA ❑NE
❑ Yes ,l No ❑ NA ❑ NE
es ❑ No ❑ NA ❑ NE
7. Do any of the structures need maintenance or improvement?
S. Do any of the structures lack adequate markers as required by the permit?
(not applicable to roofed pits, dry stacks. and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need
maintenance or improvement?
i 1. Is there evidence of incorrect lapel application? if yes, check the appropriate box below.
❑ Excessive Ponding ✓Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu. Zn, etc.)
❑ PAN ❑ PAN > 1 O% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure'Sludge into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area
12. Crop Type(s): '} S
13. Soil Type(s):
14. Do the receiving crops differ from those designated in the CAWMP?
15. Does the receiving crop and/or land application site need improvement?
16. Did the facility fail to secure and/or operate per the irrigation design or wettable
acres determination?
17. Does the facility lack adequate acreage for land application?
18. Is there a lack of properly operating waste application equipment?
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available?
20. Does the facility fail to have all components of the CAW]N P readily available? 1f yes, check
the appropriate box.
❑ WUP ['Checklists ❑ Design ❑ Maps ❑ Lease Agreements
21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes laga ❑ NA ❑ NE
❑ weekly Freeboard ❑ Waste Analysis ['Soil Analysis ❑ Waste Transfers ❑Weather Code
0 Rainfall ['Stocking❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and I" Rainfall Inspections ❑Sludge Survey
22. Did the facility fail to install and maintain a rain gauge?
23. if selected, did the facility fail to install and maintain rainbreakers on irrigation equipment?
Page 2 of 3
❑ 4' es
❑ Yes
❑ Yes
Q Yes
0 Yes
0 Yes O.Nnn
❑ Yes ❑ No
NA
❑ NA
❑NA
❑ NE
❑ NE
❑ NE
❑ NA ❑ NE
❑ NA O NE
❑ NA
❑ NA
❑ NE
❑ NE
❑ Waste Application
Date of inspection:
❑ Yes
❑ Yes
Structure 5
171 No
'No
V e' ❑
❑ NA ❑ NE
❑ NA ❑ NE
Structure 6
No ❑
NA ❑ NE
❑ Yes dNo ❑ NA ❑ NE
❑ Yes
❑ Yes
2'Na
0
❑Outer:
❑ Yes ErNo 0 NA ❑ NE
❑ Yes [hlo ❑ NE
5/l2/2020NA Cunh❑inued
24. Did the facility fail to calibrate waste application equipment as required by the permit?
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check
the appropriate btox(es) below,
Ft}ilure to complete annual sludge survey EI Failure to develop a POA for sludge levels
on -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance::
ic:ca
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27, Did the facility fail to secure a phosphorus Toss assessments (PLAT) certification?
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
If yes, contact a regional Mr Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
permit? (i.e., discharge, freeboard problems, over -application)
3l. Do subsurface the drains exist at the facility{? If yes, check the appropriate box below.
❑ Application Field ❑ Lagoon/Storage Pond ❑ Other:
❑ Yes
❑ Yes
❑ Yes
0 Yes
❑ Yes
❑ Yes
32. Were any additional problems noted which cause non-compliance of the permit or CA WMP?
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
34. Does the facility require a follow-up visit by the same agency?
Q Yes
❑Yes
0 Yes
asio
❑ NA
❑ No ❑ NA
0 NE
❑ NE
❑ No ❑ NA ❑ NE
[2r/No ❑ NA ❑ NE
0/No ❑ NA ❑ NE
❑ No
51 No
El/No
11 ❑ NA ❑ NE
❑NA ❑ NE
❑NA ❑NE
Comments (refer to question #1; Explain any YES answers and/or anv additional recommendations or any other comments.
1brtgll.ttr 1•a51�l(Cc/
Use drawings of facility to better explain situations (use additional pages as necessart•}.
\ l -d 5 wi 1(30
11_ a`.5 — � � �uC
Q�,rt oral _ L4 ,
unct r 5U. kia licit cot l�
mac\k-e- 2(
7- 1S 2
` 5r o �) 1 ,
t;t M air
F s '' u F }3e d 1 [ C L[r lc, ,.0 wl 4
Pate of inspection: iti -«
❑ Yet;
0,65
IAA 1) - 31- L
1
s ec
zct -Sci??%1} ‘/"4-
0 NA
❑ NA
❑ NA
❑ NE
❑ NE
❑ NE
Reviewer/Inspector Name:
Reviewer/Inspector Signature:
Page 3 of3
lPl'D -µ C)Y-tCio+—_'1',
hone:
It - Ib
Date:
5112/2420