HomeMy WebLinkAboutSW5211202_O&M Agreement/Plan_20220203Project Name: Nash 97, LLC
Project Location: 11250 West NC 97, Middlesex NC 27557
Cover Page
Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location.
Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can
affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s).
The SCM(s) on this project include (check all that apply & corres onding O&M sheets will
Infiltration Basin Quantity:
Infiltration Trench Quantity:
Bioretention Cell Quantity:
Wet Pond Quantity:
Stormwater Wetland Quantity:
Permeable Pavement Quantity:
Sand Filter Quantity:
Rainwater Harvesting Quantity:
Green Roof Quantity:
Level Spreader - Filter Strip Quantity:
Proprietary System Quantity:
Treatment Swale Quantity:
Dry Pond Quantity:
Disconnected Impervious Surface Present:
User Defined SCM Present:
Low Density Present:
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Type:
No
No
Yes
automatics
I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for
each SCM above, and attached O&M tables. I agree to notify NCDEQ of any problems with the system or prior to any changes to the
system or responsible party.
Responsible Party:
Title & Organization:
Street address:
City, state, zip:
Phone number(s):
Email:
Cypress Creek Renewables 1. LC
Andrew Nourafshan, Managing Director, Structure Finance
5310 S. Alston Ave. Bldg. 300
Durham, NC 27713
415 842-2603
andrew.nourafshan ccrenew.com
Signature: Date: \0 2i 2ai✓I
a Notary Public for the State ofa
County of do hereby certify that�nm�
personally appeared before me this day of C_X-fGgeZ ,'20 and
acknowledge the due execution of the Operations and Maintenance Agreement .
Witness my hand and official seal,
Seal
A notary public or other officer completing this
HECTOR O M A R AI D A N A a certificate verifies only the identity of the
V COMM. #E 22ALDA individual who signed the document to which
(� .� NOTARY PUBLIC • CALIFORNIA this certificate is attached, and not the
SONOMA COUNTY ci document,truthfulness, accuracy, or validity of that
g . COMM, EXPIRES C1CT..I, 2022 document,
F
My commission expires /�1 ` �S/ ?UzZ
STORM-EZ
10/27/2021
Version 1.5 O&M Agreement Page 1 of 1
User Defined SCM Maintenance Requirements
Section 1
Important operation and maintenance procedures:
The entire Project vegetated area will be carefully managed to reduced sediment load discharge.
Minimize use of herbicides and fertilizers per NCDEQ Stormwater Manual E-6 Recommendation 4
Avoid compaction of Subsoil per NCDEQ Stormwater Design Manual E-6 Recommendation 1
Avoid concentration of Stormwater per NCDEQ Stormwater Design Manual E-6 Recommendation 3
The system will be inspected at least quarterly. Records of operation and maintenance will be kept in a known set
location and will be available upon request.
Section 2
Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately.
SCM element:
Potentialproblem:
How to remediate theproblem:
Entire Vegetated Area
Areas of bare soil/erosion
Regrade as needed and replant disturbed areas
Entire Vegetated Area
Vegetation too short/long
Maintain vegetation at a height of 6 inches
Receiving Water Body
Erosion or sedimentation
Contact NCDEQ Regional Office
Low Density Maintenance Requirements
Important maintenance procedures:
The drainage area to the vegetated conveyance or vegetated receiving area will be carefully
managed to reduce the sediment load to the vegetated conveyance or vegetated receiving area.
After the initial fertilization to establish the grass in the vegetated conveyance or the vegetated
receiving area, fertilizer will not be applied to the vegetated receiving areas.
The vegetated conveyance or vegetated receiving area will be inspected quarterly. Records of operation and
maintenance will be kept in a known set location and will be available upon request.
Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately.
SCM element:
Potential problem:
How to remediate the problem:
Vegetation is too short or
Maintain grassed vegetation such that the swale or vegetated
Vegetation
too long.
area does not erode during the peak flow from the 10-year
storm
Trash/debris is present.
Remove the trash/debris.
Areas of bare soil and/or
Regrade the soil if necessary to remove the gully, and then re -
Vegetated receiving
areas
erosive gullies have
sod (or plant with other appropriate species) and water until
formed.
established. Provide lime and a one-time fertilizer application.
Clogging has occurred.
Clean out the outlet device. Dispose of the sediment off -site.
The outlet device (if
applicable)
The outlet device is
Repair or replace the outlet device.
damaged
Erosion or other signs of
damage have occurred at
Repair the damage and improve the flow dissipation structure.
the outlet.
Discharges from the site
The receiving water
are causing erosion or
Contact the local NCDEQ Regional Office.
sedimentation in the
receiving water.