HomeMy WebLinkAboutSW5211202_BUA Allocations_20220203CA 6 Project: Nash 97 Solar, LLC Nash County, NC Date: 12/13/2021 By: I Graham, PE Checked: M. Carreon, PE 1. SSW-SWU-101 BUA Calculations Backup 045182 — It3 Total Property Area (ac) 23.3 ac From E&SC Permit Approval Letter (9/28/2015) Total Coastal Wetlands Area (ac) 0 ac Surface Waters (ac) 0 ac Total Project Area (ac) 23.3 ac Basi In Drainage Area i Receiving Stream Name Turkey Creek New River Basin Stream Class C; NSW Stream Index Number 27-86-3-(1) Total Drainage Area (sf) 1,014,948 On -site Drainage Area (sf) 1,014,948 Off -site Drainage Area (sf) 0 Proposed Impervious Area (sf) 47514 1.1 ac % Impervious Area (total) 4.68% 22.2 oc (Grassed Areas (See BUA max. below) Impervious Surface Area Drainage Area 1 On -site Buildings/Lots (sf) 0 On -site Streets (sfJ 44297 DWG On -site Parking (sf) 0 On -site Sidewalks (sf) 0 Other on -site (sf) 3217 3008 Equipment Pods (DWG) 209 Foundation Posts (Piles); assume 4-inch diameter (Total No, of Posts =2,396 ) Future (sf) 0 Off -site (sf) 0 Existing BUA (sf) 0 Total (sf) 47514 2. NOTES a. Nash County Is a Phase 2 Tipped County b. Subject to Urbanizing requirements per 15A NCAC 02H.1017 c. BUA is 24% max. 111111111„" 00 ••••OPEN ss�Ap�� f Project: Nash 97 Solar, LLC Nash County, NC Date: 12/13/2021 By: 1. Graham, PE Checked: M. Carreon, PE 3. NCDEQ Stormwater Design Manual (Rev. 12-13-2018) E-6 Solar farms Regulatory Requirements: DEMLR allows solar panels associated with ground -mounted solar farms to considered pervious Other structuures associated with the solar farm - buildings, entrance roads, transformers (concrete pads) and footings are still considered impervious. Recommendation 2: Disconnect runoff from solar panel arrays �0452 ' i TMW��. 3 The project has been installed to allow for vegetation under and in between the solar arrays; and the terrain slopes are less than 8% along the disconnection flow path (see dimensions below); however, it does not meet the 80% minimum threshold. Recommendation 6: Limit vertical clearance to less than or equal to 10 feet The project solar panel maximum heights are less than 10 feet, which helps prevent erosion and scourig along the dripline (see Solar Panel and Racking System Details provided). Solar Panel Width M 13.10 per As -Built ALTA Row Spacing (ft) 9.21 per As -Built ALTA Average Slope (%} 5.70% per Civil Plans < 8% Yes DL Ratio 70.3% Reference Plans for overall vegetated open space areas. >80% No Figure 9. Disconnection of flow path between solar panels when average slope is less than 8%. Solar Panel Width o X F< Disconnection Length t X it I Solar Panel Width m X it Avg Slope 5 8% In general, the minimum disconnection length between two rows of solar panels is equal to the width of each row, as shown in Figure 1. However, some panel layouts include horizontal gaps between individual modules that allow stormwater to drip off the panels at intervals much smaller than the width of each row. In these instances, the solar farm can be designed with a smaller disconnection length, provided that they will not cause concentration of stormwater runoff. The disconnection length should not be less than 80% of the total solar panel width.