Loading...
HomeMy WebLinkAboutNCG030085_2021 DMR_20211216DAIMLER Sean Quarry Sr. Environmental Engineer DaimIerTrucks 1800 North Main Street Mount Holly, NC 28120 704.822.7034 Phone November 10, 2021 NCDEQ - Division of Water Resources 610 East Center Avenue Suite 301 Mooresville, North Carolina 28115 To whom it may concern: Please find the enclosed November Stormwater Discharge Outfall (SD) #001 and #002 form for the Daimler Trucks NA, LLC - Mount Holly Truck Manufacturing Plant (TMP). The stormwater samples were collected on November 4, 2021. Results from this sampling event show an exceedance of the following parameter(s) at or above the corresponding benchmark: • SDO #001 (11-04-2021) -- COD - 220 mg/L (Benchmark 120 mg/L) • SDO #001 (11-04-2021) - Zinc - 0.230 mg/L (Benchmark 0.126 mg/L) Daimler remains in Tier 3 for Zinc and enters Tier 2 for C.Q.D. at SDO #001. The Facility remains in Tier 3 for Zinc and Copper at SDO #002. Shield will continue to perform monthly sampling per Tier requirements until instructed to decrease sampling frequency by Daimler. Action Plans were accepted on October 26, 2021 and DTNA continues to make efforts to completion of these line items. Should you have any questions, please contact me at 704-822-7034 or sean.guari-y@daimier.com. Sincerely, Daimler Trucks NA, LLC Sean Quarry Sr. Environmental Engineer Enclosures - DTNR signed DMR forms (2 copies) SHIELD ENGINEERING December 1, 2021 Mr. Scan Quarry Daimler 'Trucks North America, LLC 1800 North Main Street Mount Holly, NC 29120 Subject: Monthly Sampling — November 2021 NPDES General Permit No. NCG030000 Daimler Trucks of North America LLC - Mount Ilolly, North Carolina Shield Project No.1140109-08 Dear Mr. Quarry: Shield Engineering, Inc. (Shield) successfully collected monthly stormwater samples for Stormwater Discharge Gutfalls (SDO) #001 and #002 at the Mount Holly facility for the month of November 2021. During the November 411 sampling event, Shield's field measurements of pH were 7.8 and 7.3, at SDO #001 and SDO #002, respectively. The analytical results of the stormwater samples collected during the qualifying storm event are attached to this cover letter. In addition, the Qualitative Monitoring Report (QMR) forms and the partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter. The Qualitative Monitoring Reports note the presence of an intermittent sulfur -like odor at SDO #001. Analytical results from the sampling event show an exceedance of C.O.D. and Zinc at SDO #001. The laboratory report notes that the TSS samples for both SDOs "were analyzed outside of analytical holding time for TSS due to laboratory error". Shield has contacted the laboratory and requested that your facility not be charged for these analyses. Daimler remains in Tier 3 for Zinc and enters Tier 2 for C.O.D. at SDO 4001. The Facility remains in Tier 3 for Zinc and Copper at SDO # 002. Shield will continue to perform monthly sampling per Tier 3 requirements until instructed to decrease sampling frequency by Daimler. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks, North America. If you have any questions in reference to this document or require further information, please feel free to contact either of the undersigned at (704) 394-6913. Respectfully, SHIELp ENGINEERING, INC. Magdaline Tzannis Senior Project Manager Uell6d4M. Greene, E1T Senior Engineer Robert L. Griffin, PE President/CEO Attachment: Discharge Monitoring Report — November 2021 4301 Taggart Creek Road www.shieldengineerigg.com Charlotte, NC 28208 Telephone 704.394.6913 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources 5tormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here For instructions Complete, sign, scan and submit the DMR via the 5tormwater NPDES Permit Data Monitoring Report (DMR) Upload Form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the aej2ronriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0085 Person Collecting Samples: Magdalene Tzannis Facility Name: Dalmler Trucks - Mount Holly Laboratory Name: Pace Analytical Facility County: Gaston Laboratory Cert. No.: 329 Discharge during this pE!riod-.EIYes 0 N❑ fif no, skip to signoture and dote} Has your facility implemented mandatory Tier response actions this sampleper_ivd for any benchmark exceedances? f Yes UNO If so, which Tier (I, II, or III)? 11, 111 A copy of this DMR has b en uploaded electronically via https:Iledocs.deg.nc.gov/Forms/SW-DMR yes No Date Uploaded: (� f [ j. Analytical Monitoring Requirements for Outfalls with Industrial Activities —Benchmarks in (Red) Parameter Parameter Outfall001 Outfall002 Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV; CA WS-IV; CA N/A Date Sample Collected MM/DD/YYYY 11/412021 11/4/2021 46529 24-How Rainfall in inches 0,15 0.15 C0530 T55 in mg/L (100 or 50`) 26 26 pH in standard units (6.0-9.0 FW, D0400 78 7.3 6.8-8.5 5W ) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0,004 0.0035 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 5W) 0.00078 0.00054 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) ❑ 230 0.082 Chemical Oxygen Demand (COD) in D0340 mg/L (120) 220 e20 00552 1 loon -Polar Oil & Grease in mg/L (15) 3.0 2.2 * Outfa Its to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmarkT55 limit of 50 mg/I.. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) 5W ($aItwat er) Notes (optional): COD and Zinc exceeded at SDO 001. Lab analyzed TSS samples from SDO 001 & SDO 002 outside of analytical holding time. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the bb ,st of my k 11OWled g!j nd belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false informatign- eruding the_oassibi!Wcf fines and Imprisonment for knowing violations." Signature of P jAittttee or Delegated Authorized Indivildual L C.i►r� ! r� - •' G ! y 5 +4 �L- �J Lr cr �.ti, �: �. C � .., Email Address ZwZa Date Phone Number