Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG030293_2021 DMR_20211221
SHIELD ENGINEERING December 1, 2021 Rick Mirecki CIRCOR Pumps North America LLC 1710 Airport Road Monroe, North Carolina 28110 Subject: Monthly Stormwater Sampling — November 2021 Certificate of Coverage No. NCG030293 CIRCOR Pumping Technologies — Monroe, NC Shield Project No. 1150109-17 Dear Mr. Mirecki: Shield Engineering, Inc. (Shield) successfully collected a monthly stormwater sample for Stormwater Discharge Outfall (SDO) #004 at the CIRCOR Pumps North America LLC — Monroe facility on November 4, 2021. The pH was measured at 7.29 and the total event precipitation was 0.14 inches. In addition to the collection of samples, Shield performed Qualitative Monitoring at SDO #004. Shield has prepared the Stormwater Discharge Monitoring Report (DMR) using the results of analyses from the commercial laboratory that the CIRCOR facility has contracted with, and the field values indicated above. The sampling - _— results from the November 4' event show that Copper was exceeded at SDO #004. The laboratory report notes that the TSS sample for SDO 4004 "was analyzed outside of analytical holding time for TSS due to laboratory error". Shield has contacted the laboratory and requested that your facility not be charged for this analysis. CIRCOR remains in Tier Three for Copper at SDO #004. Shield greatly appreciates the opportunity to provide environmental services to CIRCOR. If you have any questions in reference to this document or require further information, please feel free to contact the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Magdaline Tzannis Senior Project Manager r. Veli dareeve Senior-Engineer Robert L. Griffin, PE President/CEO Attachments: DMR —November 2021, Pace Analytical Report, Qualitative Monitoring Reports 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results, Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0293 Person Collecting Samples: Kevin Stachura Facility Name: Circor Pumping Technologies Laboratory Name: Pace Analytical Facility County: Union Laboratory Cert. No.: 329 Discharge during this period: ©✓ Yes 0 No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? E]Yes 0 No If so, which Tier (l, ll, or III)? III A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ®✓ Yes 0 No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 004 Outfall005 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 11/4/2021 46529 24-Hour Rainfall in inches 0.14 C0530 TSS in mg/L (100 or 50*) 13 pH in standard units (6.0 — 9.0 FW, 00400 6.8-8.5 SW) 7.29 Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0.011 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <0.010 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.090 Chemical Oxygen Demand (COD) in 00340 mg/L (120) <20 00552 Non -Polar Oil & Grease in mg/L (15) <5.0 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): Copper exceeded at SDO 004. Lab analyzed TSS sample from SOO 004 outside of analytical holding time. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 12- Z( -2 ( Signature of Permittee or Delegated Authorized Individual w1o,���n�y� r�t rGo ��com Email Address Date 717--60l--ITS q Phone Number