Loading...
HomeMy WebLinkAboutWQ0040253_Regional Office Historical File Pre 2018ROY COOPER, Gown°, MICHAEL S. RICAN ary LLNDA CULPEPPER ittrertm Dgector NORTH CAR INA Environmental Quolify August 30, 2018 Numa Robertson, Vice President Corporate Services Union Electric Membership Corp 1.525 North Rocky River Road Monroe, NC 28110 Subject: Permit No, WQ0040253 Union Electric Membership Corp Union Power Cooperative Site Improvements Wastewater Collection System Extension Permit Union County Dear Mr, Robertson: In accordance with your application received August 24, 20.18, we are forwarding herewith Permit No. WQ0040253 dated August 30, 2018, to the Union Electric Membership Corp (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the foliowing conditions contained within this permit: Condition IL t: This permit shall not be automatically transferable; a request must be made and approved. Condition 1E4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 21 ;0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North. Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. tate. af ‘,..10rtk", oar,.)5na Erw,r,:,"Irflenta Quality Water Researiales `,A,ateruaft Reglona (eon klocrTL r301 \i,orth °are saa 2B-115 704 6E3 169z1 Vicinity Map Union Po r er Cooperative Site improvements Hereby Bridge ake Park ley Chap& Legend Property_Limits Min S 1 inch = 10,000 feet Sources: Esri, HERE, DeLorme, USGS, Intermap, increment P Corp., NRCAN, Esri Japan, MEfl, Esri China (Hong Kong), Esri (ThaHand), Mapmyindia, C OpenStreetMap contributor; and the GIS User Community Stantec Project No.:: June 2018 78440166 FTA 04-16, Item F Site Maps Union Power Cooperative Site Improvements Topographical Map Union Power Cooperative Site Improvements Stantec Project No.: 178440166 June 2018 FTA 04-16, Item F Site Plan Union Power Cooperative Site Improvements MOW Union Power Coop Site Improver 1 einity Map egend Union Electric Membership NORTH CAROLINA Department of the Secretary of State CERTIFICATE OF EXISTENCE I, Elaine F. Marshall, Secretary of State of the State of North Carolina, do hereby certify that Union Electric Membership Corporation is a corporation duly created, organized and existing under the laws of the State of North Carolina, having been incorporated pursuant to the provisions of Chapter 117 of the North Carolina Session Laws of 1935 by Certificate of Incorporation dated the 22nd day of February, 1939. I FURTHER certify that the said corporation is an active North Carolina corporation, and that the said corporation has not filed a Certificate of Dissolution and continues to be in existence in this State as of the date of this certificate. Scan to verity online. Certification# [02913260-1 Reference# 14657685- Page: 1 of 1 Verify this certificate online at littp // vw.sosnc.goviverification IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal at the City of Raleigh, this 12th day of June, 2018. Secretary of State North Carolina Secretary of State Search Results Page 1 of 1 •. Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings Electric .Membership Cooperative Legal Name Union Electric. Me. iibership Corporation Information Sosld: 0153322 Status: Current -Active Annual Report Status: Current Citizenship: Domestic Date Formed: 2/22/1939 Fiscal Month: December Registered Agent: Andress, Gregory S. Addresses Reg Office Reg Mailing Mailing 1525 N Rocky River Rd PO Box 5014 PO Box 5014 Monroe, NC 28110 Monroe, NC 28111 Monroe, NC 28111 https://www.sosrc.Gov/online_services/searchIBusiness_ Registration_Results 8/27/2018 AlOROS State of North Carolina Department o Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-1.6) Entity I equesting; Allocation: Union Electric °Iembersh'ip Corp Project Name for which flow is being requested: nion Power Coop Site Improverrients FTS . r7r":v he recprrr> ? ar Ingle project v, the. proposed sveasre.r<ax a r fe r:•s. the ;'W7mP i not responsible/Or all pump I, Con lete this section onI) if you are the owner t f tht a. WWTP Facility Name: City of Monroe WWTP b. WW1? Facility I'ertztit : NC 0024333 at ent plant. c, 'V./VIP facilit> "s permitted fl A1Iflows are in MGD .4 d. Estimated obligated flow not yet tr"ibtttary to the WWII' e. 'WWTP facility's actual avg, flow tag flow for this specific request .8100 ii36 :al actual and obligated flows to the facility 6.,3701. h. Percent of pemtitted flow used 6 1.3% Complete this section for each pump station you are responsible: fear along the route of this proposed wastewater flow. List pornp stations located between. the project connection point and the W' '`I`P. (A) (1) (C) (D)- l Design C)bl igated, Pump Average Daily ,Approx. Not Yet "fatal Current Station Firm Flow** Current Avg. Tributary How Plus (Name or Capacity, * ('Firm I pt), Daily Flew, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity". 'ha l+lrttt Capacity nt`an putnp station is defined can be achieved with the tat°est pump taken out of scrvi ** Design Average .Daily Flow is the firm capacity of the pump statinn divided by a peaking factor (p1) not less than 2..5. **''` A Planning ,Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewe Downstream Permit Number: of III. Certification Statctrrcnt. I Russell C:olhatla ._.__ certify to the best of' y knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treat met t facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstreatn pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment Where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendum for which I a,m the responsible party. Signature of this form indicates acceptance of this wastewater flow. wing U icF°tit` Signature Date Paget of 6 1- E"SF :04-t6 III. Certification Statement: I Russell Colbath certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. igning Official Signature Date Page 2 of 6 P'r i f1Q_1 h Stantec July 10, 2018 File: 178440166 Mooresville Regional Office Water Quality Section 610 E. Center Avenue Mooresville, NC 28115 STANT"EC CONSULTING SERVICES, INC, 2127 Ayrsley Town Boulevard Suite 300, Charlotte NC 28273 Reference: Union Power Cooperative Site Imp ve nts WCROS Please find attached the permt submittal package for the above referenced project. This project includes the construction of a new administration building, vehicle maintenance buildings, and associated structures. The new vehicle maintenance buildings are not connected to the sewer system and have their own spill containment facilities, New sewer mains and manholes will collect domestic flows only and discharge to the City of Monroe's sewer system. Included with this package are the following items: 1. Cover letter. 2. Fast Track Application and Attachments (FTA 04-16). 3, Documentation of registered corporation with NC. 4. Downstream Sewer Flow Tracking/Flow Acceptance Form (FTSE 04-16). 5. Application Fee (Check for $480 payable to NCDEQ), Please do not hesitate to contact me with any questions about the application or project in general. Regards, Robert Bernard PE Associate Phone: 980-297-7653 Fax. 704-329-0905 Robert, bernard. stantec. com Attachment, Application and attachments CC' Numa Robertson, Union Electric Mbership Corp. Craig Wall, PARIC