Loading...
HomeMy WebLinkAboutWQ0038838_Complete File - Historical_20171231Water Resources E'1VMQNMENTAL QUALITY November 2, 2016 John Shutak, CIP Program Manager Union County 5OO N. Main Street, Suite 600 Monroe, NC 28112-4730 ,AT MRORY Governor DONALD R. VAN DER VAART S. JAY ZIMMERMAN 1Jireeior Subject: Permit No. WQ0038838 Union County Waxhaw Sewer Improvements Wastewater Collection System Extension Permit Union County Dear Mr. Shutak: In accordance with your application received October 26, 2016, we are forwarding herewith Permit No. WQ0038838 dated November 2, 2016, to Union County (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina Environmental Quality; Water Resources { Waled iy Rel Mooresville Regional Office; 610 East Center Avenue, Suite 301 Mooresville,, North 704 663 1699 on5 28115 If you need additional information concerning this matter, please contact Barry Love at (704) 235-2143 or via e-mail at barry.love@ncdenr.gov. Sincerely, 1-6-(-- by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Jim C. Stowe, P.E. (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) Page 2 of 8 Environmental Quality .WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT 1n accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to • Union County Union County for the construction and operation of approximately 860 linear feet of 8-inch gravity sewer to.serve as part of the Waxhaw Sewer Improvements project, and the discharge of zero additional gallons per day of collected domestic wastewater(rehabilitation/replacement .with no new flow) into :the -Union County existing sewerage system, pursuant to the application received October 26, 2016, and in conformity with 15A NCAC 2T,• the Division's Gravity Sewer Minimum .Design Criteria adopted February 12, 1996, as applicable; the Division's. Minim* Design Criteria for the Fast -Track Permitting of -Pump Stations .and Force Mains adopted June 1, 2000, 'as applicable; and other- supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. ., This permit shall be effective from thedate of issuance until rescinded and shall be subject to the specified condio tations contained therein. — by W. Corey Basinger,'Regional ,Supervisor Water Quality Regional Operations Section - Mooresville Regional Office Division of Water Resources, NCDEQ • Permit Number: WQ0038833 Permit Issued: November 2, 2016 Page 3 of 8 �UU�������������/�������U`����������U���� .���� " ,�m.o�ou.o�v v�� PERMIT "=���"�". ,�""»~o�v Union County is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extensiom, The sewage and wastewater collected hythis system shall be treated |nthe Union County Twelve Mile Creek Wastewater Treatment Plant in accordance with Permit Number NCO085359. Permitting of this project does not constitute an acceptance of any part of the projectthatdmesnotnneet l5ANCAC3T;the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996,as applicable; and the Division's Minimum Design ChtedafortheFast-Tr ckPennitdoQofPunnp5tadmnsond Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Caro lina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. L SPECIAL CONDITIONS 1. No new flow shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 11. STANDARD CONDITIONS l This permit isnot transferable. |nthe event there i$a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials esmay beappropriate. The approval mfthis request shall beconsidered onits 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC %T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as, applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000,as applicable; and other supporting materials unless specifically mentioned herein. (15A NCAC 02T.0110] This permit shall be effective only with respect to the nature and volume of wastes described iothe application and other supporting data. [15A NCAC 02T.01101 4. The wastewater collection facilities shall beproperly maintained and operated atall times. The Pennhtteeshall maintain compliance with anindividual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCA[ 2T .8403. If an individual permit isnot required, the following performance critehushaUbemet:Kl5ANCACOZT.Q1O8(b)l: Page 4 of 8 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. _ An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a),.and public notice shall De t:.-�rI'ried as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in placeas follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report.by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24, following the occurrence or first knowledge of the occurrence of either of the following: Page 5 of 8 a. Any process unit failure, due tnknown orunknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, e1c.;or b. Any S5Oand/or spill over 1,0OQgallons; or c Any 5SOand/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800} 858-0360or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part | of Form C3'6SO (or the most current Division approved form) within five days following first knowledge nfthe occurrence. This report must outline the actions taken or proposed tobetaken to enxurethatthe problem does not recur. Part ||ofForm CS-SSO(or the most current Division approved fmrnn) can also be completed toshow that the SSQ was beyond control. [G.S. 143-215.1C(a1)] 6. Construction ofthe gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters ofthe State. [15AN[4CO2T.0108(b)l 7. Upon completion ofconstruction and prior tooperation ofthese permitted facilities, the completed Engineering [ertificatl�mn6^noattached tnthis permit shall be submnittedvviththe require d-supportng, documents to the address provided on the fmrmm. Acomp|etp certification is one where the form is fully executed and the supporting documents are provided asapplicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification xhaU be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. \fthe permit 1sissued %waprivate entity with anOperational Agreement, then a copy ofthe Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. Acomplete certification isone where the form iofully executed and the supporting documents are provided asapplicable. Supporting documentation shall include the following: a. One copy ofthe project constructi0nrecorddrawvings(p\an&prVfi|eviewmofswvver|inas&fmrce mains) afthe wastewater collection system extension. Final record drawings should beclear on the plans oromdigital media (CD or DV8 disk) and are defined asthe design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level contro I settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet m/e\|, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. if portable povve, source or pump is dedicated to multiple stations, anevaluation mfall the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timefranmes,shall beprovided. c Changes tothe project that donot result \nnon-compliance with this permit, regulations,orthe Minimum Design Criteria should beclearly identified onthe record drawings, onthe certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow; pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing andsubmitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by thePegnittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10.'Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater .collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction.or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Union County WQ0038838 Waxhaw Sewer Improvements November 2, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation, it should be submitted in a manner that documents the Division's receipt, Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed&pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I, , as a duly registered Professional En sneer in the State of North Carolina, having been authorized to observe (© periodically, [ weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Profession& Engineer's Se& w/signature & date: 0 Final 0 Partial (include description Certification Comments/Qualifiers (attach if necessary): State of North Carolina I Environmental Quality I Water Resources I Wader Quality Regional Operation Mooresville Regional Office 610 East Center Avenue, Suitt 301 p Mooresville, Nardi Carolina 28115 Division of Water Resources State of No. h Carolina Department of Environmental Quality Division. of Water Resources I5+ii. NCAC 02T .0300 FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number luc.d by hwR All items mttst be completed or the application will be returne€� APPLICANT INFORMATION Applicant's name: Union County (company, municipality, HOA, unlit Applicant type: Individual © Corporation Caenera1 Partnet'sh Federal State:`C:tactrut lw'lunicipal John Sbutak, P.E. per ,15A NCAC 021 t31f16(jj Signature autitmiry `s n Title: Project lvlanaer. 4. ,applicant's ratailin address 500 N Main Street,_Smte'i600 City Monroe State: NC lip: 281 I2-4730 Applicant's contact inftarrnatiott: Phone number (704) 283-3651 Email Address: johrtoncoun 0 Other 1I. PROJECT INFORMATION: 1. Project naame 41 ahawvewvet 1trultcseI1Sent.S 2. Application/Project status: -oposed (New Perron © Fxistitt Permit/ li as tnodification, provide the expermit number: WQ00__. . and issued date: if ne construction but part of a toaster plan, provide the existing permit number: WQ00 . 3. Country inhere project is located: 4, Approximate Coordinates (Dec:in .1 lyeuirees): 1. a:ttituucle: i4 9 1`` t.r n itttc e: ti 744 S, Parcel ID (if applicttbte) )nr Parcel ID to closest dosw°rtsrreatn sew er') III. CONSULTANT INFORMATION: I. Professional Engineer Jim C.Stowe l..icense Number: 32639 Firm: Willis Enkineers, Inc. Mailing address: 10700 Place TSuite 1 t,5 City: Charlotte State: NC Zip: 28 77-815`? Phone number; (7044) 338-4671 Email Address: jitfia a ss illi cngineets coin IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility. Name Twelve !Ville \k WTP Permit Number. NC.00$5.,335,9 Owner Name: Union County RECEIVING DOWNSTREAM SEWER INFORMATION (.if different than WTF): 1. Penarit Number(s): WQ_ _ Downstreatnt (Receis System \Vide Collection Sy, Ctwsdtter Name(s):� le: it Number(s) (if applicable): A /QCS inch elv�Own�taed Public Util_i FORM: F`FA 04-16 GENERAL REQUIREMENTS 1. if the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEW) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ENo ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Residential Leased ❑ School / preschool / day care ® Food and drink facilities ® Businesses / offices / factories ® Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) ) Is there a Pretreatment Program in effect? 6. Has a flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes > If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: ❑ Car Wash ❑ Hotel and/or Motels D Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) ❑ Yes ❑ No ® No Establishment Type (see 02T.0114(f)) Daily Design Flow ',b No. of Units Flow Commercial/Domestic 0 gal/day 0 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See I5A NCAC 02T .0114(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (Le., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 860 Ductile Iron D. Section 1I & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pumn Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0 Longitude: - 0 3. Design flow of the pump station: " millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 6. Power reliability in accordance with I5A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(I)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - I5A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ZYes No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools I0 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage > If noncompliance with 02T.0305(f) or (g)\ see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected ® Yes ❑ No 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters > Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑Yes No > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ®Yes ❑No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, J r,.e S. C • ¶*o e (Professional Engineer's name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): tKtATA4 - GEr 'Nccprith•4. 4+ r412.- (Signature Authority's name & title from Application Item I.3.) ZS 6E0 l�o attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: %t4,/6 FORM: FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Union County Project Name for which flow is being requested: Waxhaw Sewer Improvements More than one FTSE may be requiredfor a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Twelve Mile WWTP b. WWTP Facility Permit #: NC0085359 All flows are in MGD c. WWTP facility's permitted flow 6.0 d. Estimated obligated flow not yet tributary to the WWTP 1.6284 e. WWTP facility's actual avg. flow £ Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 4.064 0.00 5.6924 94.87 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)-(A-D) Design Obligated, Pump Average Daily Approx, Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pt) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewer): Waxhaw Sanitary Sewer Improvements Downstream Permit Number: WQ002 I 064 Page 1 of 6 FTSE 04-16 III. Certification Statement: I j L . SG. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Sig Official Signature Date Page 2 of 6 FTSE 04-16 EXISTING SEWER PROPOSED 8" SEWER sty INEERS September 2016 PROPOSED E" SEWER PROPOSE 8" SEWER EXISTING SEWER Sources Esr , DeLarme, NAVTEO, USGS, #nterrna , IPC., NRCA Japan, MET4, Esru China (Hong Kong), Esr( (Thailand), TorTonnn, 20 Waxhaw Sewer Improvements Street Level Site Map Scale: 1"=500' ENGINEERS September 2016 Waxhaw Sewer Improvements USGS Site Map Scale: 1 "=1 sa4Q' IN IIS ENGINEERS October 21, 2016 NC Department of Environmental Quality Water Quality Section Mooresville Regional Office 610 E. Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Union County Waxhaw Sewer Replacement and Addition Contract 5.0 — Waxhaw Sewer Improvements Gentlemen: Union County is planning to construct approximately 700 feet of new sanitary sewer lines to replace existing problematic lines in Waxhaw, North Carolina, The replacement sewer provides service to businesses along South Main Street between South Providence Street and South Church Street. Union County is also planning to construct approximately 160- feet of 8-inch sewer to eliminate an excessively long service lateral. Both locations are currently served by existing sewers and the replacement sewers will not produce any additional wastewater. On behalf of the County, enclosed please find two sets of the following documents for your review and approval: • The executed Fast -Track Application (FTA 04-16). • The executed Flow Tracking/Acceptance Form (FTSE 04-16). • A USGS Site Map illustrating the location of the proposed sanitary sewer • A Street Level Site Map showing the approximate project area, • A check in the amount of $480 for the Application Fee. Should you have any questions or need additional information, please feel free to call me at 704,338,4671 or email me at jim@will isengineers.com Yours very truly, WILLIS ENGINEERS ode Jim C. Stowe, P.E. Attachments cc w/ Attachments: Michael Caldwell, Union County Public Works 10700 Sikes Place, Suite 115 Charlotte, North Carolina 28277 704,377.9844 / NC License F-0114 Central Files: APS _ SWP 11/212016 Permit Number WQ0038838 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1.00 individual Primary Reviewer barry.Iove Coastal SWRuIe Permitted Flow 0 Facility Permit Contact Affiliation Facility Name Waxhaw Sewer Improvements Location Address Owner MaJor/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Government - County Owner Affiliation Cindy Coto DateslEvents 500 N Main St Monroe NC 28112 Orig Issue 11/2/2016 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 10/26/2016 11 /212016 11 /2/2016 Regulated Activities Requested /Received Events Food and kindred products manufacture Office Retail Subdivision Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasln ater Resources Environmental Quality August 22, 2017 Crystal O. Panico, New Development. Program Manager Union County Public Works 500 North Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification Acknowledgement Project: Waxhaw Sewer Improvements Permit No. WQ0038838 Permittee: Union County Public Works County: Union Dear Ms. Panico: ROYCOOPER Governor MICHAEL S. REGAN 5,ecrelcrrtN S. JAY ZIMMERMAN Dfreclor The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on August 21, 2017. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items anon -compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Foram. PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded frorri http://p©rtal.ncdenr.org/weld/wq/swp/ps/cs/pnoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact rrie at (704) 235-2143. Sincerely, Barry Love Environmental. Specialist cc: Jaynes C. Stowe, P.E. (Willis Engineers, 10700 Sikes Place, Suite 115, Charlotte, NC 28277) Central Files MRO State of No h areslttrtc 1 Envth amen Mooresville Regional Office 1 61U East Center Avenue, Su 7O4-663-1699 of Regir rthCa FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: PERMIT #: PROJECT: ISSUE DATE: Union County WQ0038838 Waxhaw Sewer Improvements November 2, 2016 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt, Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received, A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. -Jo g iuT _ Printed Name. Title t p ri2o5,4r' t'4,1-4446 ENGINEER'S CERTIF CATION I, 0 , as a duly registered Professional er in the State of North Carolina, having been authorized to observe i, periodically, weekly, full time] the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum. Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: [ , Final [11 Partial (include descr Certification Comments/iulal n attach if necessary): State of North Carolina 1 F itiuonmental. Quality l Water Resources' Waler Quality Reb'ionat Operations Mnrv,Pcville 52euinnal Officci 610 East Center Avenue, Suite 301 1 Mooresicilie, Noah Carolina '281 I5 Union County AsBuilt Gravity Sew Waxhaw Sewer Improvements Peak Full Flow Full Flow Bearing Invert Rim Flow Dia. Length Slope Capacity °A° Velocity . MH Sta. In (ft) (gpm) (in) (ft) (ft/ft) (gpm) Full (fps) West Block 1 00+00.00 640.79 652.03 42 8 95.34 0.0138 637 7 4.1 S84d07'25"W 2 00+95.34 642.11 645.42 42 8 82.82 0.0091 515 8 3.3 N06d12'30"W 3 01+78.16 642.86 649.10 42 8 175.58 0.0258 869 5 5.6 S 83d 40' 59" W 4 03+53.74 647.39 651.73 42 8 47.94 0.0398 1080 4 6.9 N 08d 10' 14" W 5 04+01.68 649.30 654.84 East Block EX 00+00.00 645.67 656.89 42 8 107.91 0.0894 1619 3 10.4 N 83d 00' 00" E 6 01+07.91 655.32 663.18 42 8 36.00 0.0131 618 7 4.0 S 39d 04' 40" E 7 01+43.91 655.79 662.87 42 8 122.46 0.0054 397 11 2.5 N 82d 47' 03" E 8 02+66.37 656.45 666.88 42 8 52.61 0.0200 765 5 4.9 N 05d 42' 07" W 9 03+18.98 657.50 669.63 _King Street EX 00+00.00 659.72 669.91 11 01 +61.2 3 670.91 675.76 Willis Engineers 1982.001-6 (20) 42 8 161.23 0.0694 1426 3 9.1 N 43d 38' 41" W August 2017 5ENGINEERS August 18, 2017 1982.001-6 (34) Mr, Corey Basinger NCDEQ — Division of Water Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Permit No. WQ0038838 Waxhaw Sewer Improvements Union County Dear Mr, Basinger: This letter is to verify that construction of the subject project has been completed in substantial compliance and intent of the plans and specifications approved under Division of Water Resources permit number WQ0038838 dated November 2, 2016. Please find attached the original, executed "Engineer's Certification" for Final Certification and supporting documents. Yours very truly, WILLIS ENGINEERS Attachments cc w/Attachments: Mr, Michael Caldwell, P.E., Union County Public Works 10700 Sikes Place, Suite 115 Charlotte, North Carolina 28277 704,377.9844 / NC License F-0114 PAT MCCRORY Governor DONALD R. VAN DER VAART Secretary. S. JAY ZIMMERMAN Water Resources Dir cor ENVIRONMENTAL QUALITY As built check list (reference 2T .0300) Reviewed By: Barry Love Review Date: 08/22/2017 Project Name: Waxhaw Sewer Improvements WQ#: WQ0038838 County: Union 1) As -built has been signed, sealed, and dated by an N.C. PE ® Yes ❑ No 2) Adequate information related to sewer lines : Note that per the 2T and MDC, there is a minimum 8" for public gravity or minimum 6" for private gravity, Three (3) feet minimum cover shall be provided for all sewers unless ferrous material pipe is specified. Manholes shall be installed: at the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet, minimum diameter of manholes shall be 4 feet (48 inches). ® Yes n No n N/A 3) Adequate information related to pump stations: Ensure power reliability option is selected (15A NCAC 02T.0305(h)). ❑ Yes ❑ No ® N/A 4) Is Project design is in accordance with (see section B.13 of FTA 12-12) 15A NCAC 02T Gravity Sewer Minimum Design Criteria (latest version), Minimum Design Criteria for Permitting of Pump Stations and Force Mains (latest version). ® Yes n No n N/A If no, a variance approval is required per the requirements of 15A NCAC 02T.0105(b) ❑ Applicant must submit TWO copies of the plans, specifications, and calculations ❑ Contact the Central Office to discuss the variance request to determine a course of action. The central office will review the variance request, and if approvable, specific language regarding the variance will be forwarded to the Regional Office reviewer to incorporate into the permit. A copy of the variance letter (or email correspondence) should be kept with the application file. 5) Project contains high priority lines (15A NCAC 02T .0402(2)) ❑ Yes ® No If Yes, insure that the permit contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a)(5) 6) Is the Sewer As -built length within 10% of the fast track applied Length? (I Original length of pipe — As built length I 1 Original length) < 10%. ® Yes ❑ No If no application need to be modified State of North Carolina f Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699