Loading...
HomeMy WebLinkAboutWQ0043088_Application (FTSE)_20220124 December 22, 2021 RK%K RECEIVE0/NC1)ENRlDWR Mr. Dean Hunkele JAN 0 3 2022 NCDEQ Wilmington Regional Office Water Quality Section water ouelny Raw" opmoos Section 127 Cardinal Drive Extension AKVW P1 gIonal hnm�.,�oa Ragloae� Office Wilmington, North Carolina 28405 Subject: NCDOT Project R-5021 NC 211 Widening Brunswick County Southeast Brunswick Sanitary District Pump Station Relocation Dear Sir: Please find enclosed the completed Fast Track Sewer Application and supporting documentation for the above -mentioned project. One original and one copy of the following are included for your review and approval. Fast Track Permit Application Permit Application Fee of $480.00 (check #173974) USGS & Street Level Maps Proiect Narrative: The enclosed documents are submitted for the relocation of the existing Southeast Brunswick Sanitary District Pump Station #4 located along the south side of Southport Supply Road SE and across the road from Sacred Heart Catholic Church. This project also includes the relocation of 8" gravity sanitary sewer and 6" force main along the south side of Southport Supply Road SE. The relocation begins at the intersection of Old Long Beach RD SE and Southport Supply Road SE and travels east towards Sacred Heart Catholic Church ending at Pump Station #4. These sewer relocations are due to impacts from construction associated with NCDOT project R-5021, widening of NC 211. The sewer relocations will not add any additional flows. Sincerely, Rummel, Klepper & Kahl, LLP Kevin Nash, PE Manager Enclosure cc: Bryan Badey PE Engineers I Construction Managers I Planners I Scientists State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Divlslon of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number. U&GdU3 D b nob mnq,tvcdbyDa'Rt All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: Southeast Brunswick Sanitary District (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Bryan McCabe per I SA NCAC 02T .0106(b) Title: District Manager 4. Applicant's mailing address: 4240 Committee Drive SE City: Southport State: NC Zip: 28461 5. Applicant's contact information: Phone number. (9I0) 457-0006 Email Address: bmecabe't southeasibrnswick.com 11. PROJECT INFORMATION: I. Project name: NCDOT R-5021: NC 211 Pump Station N4 Relocation 2. ApplicationfProject status: ® Proposed (New Permit) ❑ Existing Pennit/Project If a modification, provide the existing permit number: %V000 and issued date: _, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number. W000_ 3. County where project is located: Brunswick 4. Approxunate Coordinates (Decimal Degrees): Latitude: 33.94895' Longitude:-78.03729' 5. Parcel ID (if applicable): _ (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: I. Professional Engineer: Kevin Nash License Number: 045517 Firm: RK&K Mailing address: 8601 Six Forks Road. Form 1, Suite 700 City: Raleigh State: NC Zip: 27615-5276 Phone number (919) 653-2627 Email Address: knash4?rkk.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Permit Number: _ W &QQ 0 'a-0 O Owner Name: V. RECEIVING DOWNSTREAM SEWER INFORMATION: I. Permit Number(s): %V0 2. Downstreanm (Receiving) Sewer Information: _ inch ❑ Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): _ FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® NIA 3. If the Applicant is a I Ionic/Property Owtmers' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ® Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing I Ionic ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic %Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Hasa Row reduction been approved under 15A NCAC 02T .0114(8? []Yes ®No If Yes, provide a cony of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (sec 02T.0114(f)) Daily Design Flow '" No. of Units Flow gal/ GPD gal/ GPD gaV GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 021.0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design Flow rates (i.e., minimum Bow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42 -4. b Per 15A NCAC 02T .0114(c), design Flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) y Do not include future flows or previously permitted allocations If permitter) flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ® Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 ViL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feel) Material 8 1,400 PVC C900DR18 ➢ Section II & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable) — 21.03 5 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: Southeast Brunswick Sanitary District Sewer IRunpstation d 2. Approximate Coordinates (Decimal Degrees): Latitude: 33.94895' Longitude:-78.03729' 3. Total number of pumps at the pump station: 2 3. Design flow of the pump station: 0.216 millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. J. Operational point(s) per punp(s): 220 gallons per minute (GPM) at 71 feet total dynamic head (-I DID 5_ Summarize the force main to he permitted (for this Pump Station): Size (inches) Length (feet) Material 6 2.065 PVC C900 DR18 8 435 HDPE DR9 If any portion of the force main is less titan 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C. Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) _ 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or ❑ Standby pump Must have automatic activation and telemetry - 15A NCAC 02T.0305 ft l )(B). ➢ Required for all pump stations with an average daily Flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily Bow less than 15,000 gallons per day 15A NCACO2T.0305(hx I)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry or ❑ Ponable pumping unit with plugged ennergency ptunp connection and telemetry: Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS - (02B.0200 & i5A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(D & (g)? ® Yes ❑ No 15A NCAC 02T.0305(0 contains minimum separations that shall he nrovided for sewer cvctemr - - Setback Parameter* - - -- - ------ Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) IO feet Reclaimed water lines (vertical - reclaimed over sewer) I8 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet #tAny private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(t) or (g). see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative informtion to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webVgge 2. Does Otis project comply with the minimum separation requirements for water mains? ® Yes []No ❑ N/A ➢ If no, please refer to 15A NCAC ISC.0%6(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ Seethe Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: _ ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(e)(61(additional permits,/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonowater management plans, etc.). 7. Does this project include any sewer collection lines that are deenmed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, server contacting surface waters, siphon, or sewers positioned parallel to streanmhanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permiltee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitlee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Mininnun Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, fir projects requiring a single variance, complete and submit the Variance/Alterative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval mac be subject to longer review times. For proiecls requiring two or more variances or where the variance is determined by llte Division to be a significant portion of the proiecl, the full technical review is required. 2. Professional Engineers Certification: 1, KEVI N N ASIa , attest (bat this application for ,502 ( " Oak( P S,-*Li (Professional Gngineer's name from Application Item 111.6 (Project Nam. fmm Application Item ILI) - has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravitv Sewers (latest version), and the Mininium Design Criteria for the Fast -Track Permiltine of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of (his submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes I43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC,fi Q7,Q,) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): attest that this application for )- i 1 _ NL all P. 5. 4 1 (Signal re Auaxnip Nance from Application Item 1.3) (Project Nancec from Applicaticm Item IL ) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understated that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and 'or criminal prosecution. I will make no claim against the Division of %Vater Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting inforination and attachments are not included, this application package will be returned to me as incomplete. NOTE. -- hi accordance with General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to S25,000 per violation. Signature:-^� ,(�---<<. --r'�-"---J----- -— Date: ------ --- ---- FORM: FIFA 06-21 Page 5 of 5 1• ,Southport -Supply Rd C � Y I�7. e ' All l eI` I s c } 6" FSS Existing Permi W00013114 f k� I NORTH CAROLINA DEPARTMENT OF TRANSPORTATION ENVIRONMENTAL ANALYSIS UNIT STIP PROJECT: R-5021 NC 211 WIDENING w T BRUNSWICK SANITARY DISTRICT