Loading...
HomeMy WebLinkAboutWQ0036953_Regional Office Historical File Pre 2018U� NCDENR $JOr1CaR]Una Department nfEnvironment and Na, Division of VV@te[ResOurces Pat McCrory Thomas A. Reeder Governor Director February 26'2Ol4 Mr, Charlie O'Caim,PE Union County Puh|icWorks 500N. Main St,Suite 500 Monroe, NI.Z8112 Ural Resources � John SkV8M3,W SecretaFy 5ubiecV Permit No. VVO0O369G3 Vintage Creek Subdivision Wastewater Collection System Extension Union County Dear Mr. O'Cain: in accordance with your application received February S' 2014' we are forwarding Permit No. VV{l00369S3 to Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall beeffective from the date of issuance until rescinded and shall be subject tmthe conditions and limitations axspecified therein, This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference, it shall be responsibility of the Union County Public Works to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties inaccordance with the North Carolina General Statute §143'2l5.OAthmuugh§I4]-2I5.G[,construction ofadditional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer tnthe licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adiudicmtory hearing upon written request within 30 days following receipt of this permit. 'This request must be in the form of written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office mfAdministrative HearimQs'6714 Mail Service Center, Raleigh, N[Z7699-67I4' Unless such demands are made, this permit shall befinal and binding. /�17N,1,IJSmvjCeCemp Raleigh. Ncrih Cnmea27�y9-/mr Location 517m_Salisbury S�Pa1eighNorth Carolina '�/604 p^una,8,9-�Or-6Jm]�,n*K '9118-K7f64g2 A111111MI& �•.. q�\ r - . '. f'E:r} 1 ' :I, 3• - n _ L � i PROPOSED SANITARY SEWER TO SERVE VINTAGE CREEK SUBDIVISION ossind of st ter body. West Fork smile Creek ROPOSED SANITARY SEWER TO SERVE VINTAGE CREEK SUBDIVISION AMANDA DR GRAPHIC SCALE (P 1iir), L tech - lame. Prop. Vintage Creek Site. YILLEY MORRIS RD. Prop. 8" gravity San. Swr. Main. • Exist. 8" Public San, Swr. Main. HProp. connection to Preserve at Brookhaven San. Swr. Main. Prop. 4" Force Main Prop. Pump Station r B US T©po MA7fibMEW, QUAMV,K4 NOM4 N*t.c5��'n.wW3,fl:Kmxlwsl. Mao rtn w%. 'nC irtza January 16, 2014 Sujatha. Nagulapally, Plan Reviewer NCDENR — Division of Water Resources 610 E. Center Ave., Suite 301 Mooresville, NC 28115 Dear Ms. Nagulapally: Enclosed are the required materials for permitting of a proposed gravity sewer and force main service connection for a proposed subdivision development in the town of Weddington called "Vintage Creek." The subdivision consists of 90' homes, based on the calculated use of 285 gallons per day per housing unit, the project site wilt generate approximately 25,650-GPD based on flow rates contained with the 02T Rules. Union, County Public Works has accepted the proposed project water and sewer plan in an approved utility sketch plan dated March 21st, 2013, The proposed sever to serve the project is a 6,222-If 8" pvc sewer main that runs through the proposed subdivision to a proposed on site pump station that includes a 2,476-If 4" pvc forcemain. The proposed forcemain pumps into the adjacent "Preserve at Brookhaven" subdivision at which point it enters the existing Union County Public Works gravity sewer system and ultimately flows to the twelve mite creek wastewater treatment plant. Please contact me if you have any questions or require additional materials., Sincerely, ESP A S i m.mons Civil Engineer EvisionManages UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Ms. Dee Browder Regarding: Sanitary Sewer to serve Vintage Creek Subdivision TRANS Date: 214/14 We are sending you: I- Copy of letter 0 Plans © Prints 0 Shop Drawings Other Copies Date 1 1/16/14 1 2/3/14 2/3/14 No. Description Cover Letter Fast Track Application Copy of Fast Track Application 2/3/14 Flow Tracking Form 1 1/14/14 68047 94 $480.00 Check (Application Fee) 1/29/14 Stream Classification Form These are transmitted as checked below: g For approval LJ For your use Remarks:. Signed: Received oy: r As requested Q For review and comments Date: • Central Files: APS — SWP •` 2/25/2014 Permit Number WQ0036953 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Gravity Sewer Extent Primary Reviewer dee.browder Coastal SWRuIe Permitted Flow 25,650 Facility Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Vintage Creek Subdivision Location Address Owner MajorlMinor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Govemment - County Owner Affiliation Mike Garbark Dates/Events 500 N Main St Monroe NC 28112480 Orig issue 2/25/2014 App Received 2/5/2014 Draft initiated Scheduled Issuance Public Notice issue Effective Expiration 2/25/2014 2/25/2014 Regulated Activities Requested /Received Events Subdivision Wastewater collection Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasln VTRACK ENGINEERING CERTIFICATIONttee: Unon County Public Works ct: Vintage Creek Subdivision Permit No. Issue Date: RECETVED°NCU NRiOVVR NAC. OrFICE Complete and submit this form to the permit issuing regional office with the following; • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CO or LtVD disk) in pdf format, Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit f I n a e Ire f r n han esultin i no -co . li nce ith this er f re tile on or rrlta mym design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineers Certification and all required supporting documentation, Therefore t is hi hi roc m end d th tll ce fiat! n be sent in a manner that prc►vides roof ©frece'iot b Charlie. P ©'Cann PERMITTEE'S CERTIFICATION he undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements , the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Development Program Manager Printed Name, Title Duns F. Signature ENi3INEER'S CERTIFICATION [) Partial LI Final PE as a duly register Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, weekly, full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal, signature, and date: This partial certification is for lots 1- 42; 62-71, and includes proposed manholes 1-6; 11-24; 30-32 SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR Mooresville REGIONAL OFFICE. 610 East Center Ave., Sulte 301 Mooresville, NC 28115 The Per responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this , Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. M UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Vintage Creek Phase 1 We are sending you: RE ,SIVEfl NOD NV DWR WOR0 �Al'�SG'I TT TAL Date: 6/18/15 Copy of letter X Plans - Prints Shop Drawings j Other Copies Date No. Description 6/15/15 6/18/15 Asbuilts Fast Track Application These are transmitted as checked below: For approval Remarks: Signed: For your use L As requested (—' For review and comments Received by: Date: Water Resources ENVIRONMENTAL QUALITY May 4,2016 Ms. Crystal Panico, New Development Program Manager Union County Public Works 500 N. Main Street, Suite 400 Monroe, NC 28112 SUBJECT: Final Engineering Certification Acknowledgement Project: Vintage Creek Subdivision Permit No. WQ0036953 Permittee: Union County Public Works County: Union Dear Ms. Panto: PAT MCCRORY Governor DONALD R. VAN DER VAART Secretcoy S. JAY ZIMMERMAN Director The Division of Water Resource's Mooresville Regional Office received the final engineering certification with record drawings for the subject sewer extension project on 05/02/2016. Enclosed is a certification page for your records. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. However, if a full technical review is conducted, you will be notified of any items of non-compliance. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received such copy from your consultant, please contact them immediately to obtain a copy. Lastly, you are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you or your company, please complete Form PNOCF since the permit is not automatically transferable. Form PNOCF can be downloaded from http://aortal.ncdenr.org/web/wq/swp/ps/cs/pnoc from the Collection Systems Applications page. Should you have any questions, please do not hesitate to contact me at (704) 235-2143. Sincerely, Barry Love Environmental Specialist cc: Mr. Danis E: Simmons; P.E., (ESP Associates,P.A., P.O. Box 7030, Charlotte, NC 28241) Central Files MRO State of North Carolina ] Environmental Quality I Water Resources 610 E. Center Avenue, Suite 301, Mooresville, NC 28115 Phone: 704-663-1699 \ Internet WWW.ncdenr.gov Pr FASt 'TRACK ENCINEERENG CiE1t2't'W 'IC.A'T"IO" Permittee: Union County Pubic Works Project: Vintage Creek Subdivision Permit No,WQOQ3695 Issue Date: 212672014 Complete and submit this for rrr to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or i VD disk) in pdf format Record drawings should indicate the design and the marked up changes during construction. Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are re uired for an chap es resultin in non•corlt iiance wild this errnit re utattons er minimum design criteria. lylcadific all©ns should be sratarnitted for to certification,, This project shall not be considered complete nor allowed to operate until the Division has received this Engineer°s Certification and ail required supporting documentation, Therefore, itis highly recommended that this certification be sent in a rtlariner that rovdes roof of recei t b thei Division. PERMIlTEE`S 'CERTIFICATION /60/ _ „ the undersigned agent for the Permittee, hereby state that this project has been c rl tructed pursuant to the appi cable standards 8& requirements , the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & raiaintain the wastewater collection system permitted herein or portions thereof, N Die silo n ,. -W ENGINEER'S CERTIFICATION Date El Partial 70 Final I Danis P as a duly registered Professional Engineer in the State of North Carolina, i a having been authorized to observe (]' periodically, weekly, EJ full untie) the construction of the subject project for the Perrnittee hereby state that, to the best of my abilities, due care and diligence was used in the observation oaf the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 02T: the Division of Water Resources (Division) Gravity Sewer MIi OW111 Criteria adopted February 12, 1996 as applicable; the Division's Minirnurn Design Criteria for thq+F{ 1" a ding of Pump Stations and Force Mains adopted June 1; 2000 as applicable; and ether suppog4 a 'fiats° North Carolina Professional Engineer's Seat, signature, and date: Fplz.. e'.t' L CENsE No 0 0587 SEND THIS FORM & SUPPOR' ATION WITH REQUIRED ATTACHMENTS TO THE FO L©ViAltl DDRESS SURFACE WATER PROTECTION SUPERVISOR Mooresville REGIONAL OFFICE 610 East Center Ave., Suite 301 Mooresville, NC 28115 The Permitter: is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow rnade tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Perrmottee to appropriate j enforcement actions. PAT MCCRORY pPriliCGpt'em9r' DONALD R. VAN DER VAART &avia y S. JAY ZIMMERMAN Water Resources a euor ENVIRONMENTAL QUALITY As built check list (reference 2T .0300) Reviewed By: Barry Love Review Date: 5/04/2016 Project Name: Vintage Creek Subdivision 1 u WQ#: WQ0036953 1) As -built has been signed, sealed, and dated by an N.C. PE ® Yes ❑ No 2) Adequate information related to sewer lines : Note that per the 2T and MDC, there is a minimum 8" for public gravity or minimum 6" for private gravity, Three (3) feet minimum cover shall be provided for all sewers unless ferrous material pipe is specified. Manholes shall be installed: at the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet, minimum diameter of manholes shall be 4 feet (48 inches). ® Yes ❑ No ❑ N/A 3) Adequate information related to pump stations: Ensure power reliability option is selected (15A NCAC 02T.0305(h)). ® Yes ❑ No ❑ N/A 4) Is Project design is in accordance with (see section B.13 of FTA 12-12) 15A NCAC 02T Gravity Sewer Minimum Design Criteria (Iatest version), Minimum Design Criteria for Permitting of Pump Stations and Force Mains (latest version). ® Yes ❑ No n N/A If no, a variance approval is required per the requirements of 15A NCAC 02T.0105(b) 0 Applicant must submit TWO copies of the plans, specifications, and calculations 0 Contact the Central Office to discuss the variance request to determine a course of action. The central office will review the variance request, and if approvable, specific language regarding the variance will be forwarded to the Regional Office reviewer to incorporate into the permit. A copy of the variance letter (or email correspondence) should be kept with the application file. 5) Project contains high priority lines (15A NCAC 02T .0402(2)) ❑ Yes ® No If Yes, insure that the permit contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a)(5) 6) Is the Sewer As -built length within 10% of the fast track applied Length? (I Original length of pipe — As built length 1 / Original length) < 10%. ® Yes ❑ No If no application need to be modified State of North Carolina I Environmental Quality + Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699