Loading...
HomeMy WebLinkAboutWQ0034930_Regional Office Historical File Pre 2018NCDENR • North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary August 13, 2010 Mr. Mike Garbark, Assistant Director of Engineering Union County 500 North Main Street, Suite 500 Monroe, NC 28112 Subject: Permit No. WQ0034930 Richard Wray Keziah Wastewater Collection System Extension Union County, North Carolina Dear Mr. Garbark, In accordance with your complete application received on August 9, 2010, we are forwarding herewith Permit No. WQ0034930 dated August 13, 2010, to Union County for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 1 Fax: (704) 663-6040 \ Customer Service: 1-877-623-6748 Internet: www.ncwaterqualitv.orq N°07thCarolina Naturally In accordance with the provisions of Article 21 of Chapter 143, General Statr tes of Norh Carolina as amended, and other applicable Laws, Rules, and Regulations, permission ,s hereby granted for the construction and operation of approximately 64 linear feet of 8-inch gravity sewer and the discharge of 285 gallons per day of domestic wastewater into the existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit: The sewage and wastewater collected by this system shall be treated in the Twelve Mile Creek WWTP (NPDES No.NC0085359) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public V1lorks. Union County must utilize whatever tracking toots necessary for planning additions of sewer flow in order to maintain compliance with the 'A 'VTR permitted limits and their collection system permit WQCS00054m If any parts, requirements, or limitations contained in this permit are unacceptable you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714 Unless such demands are made this permit shalt be fiinal and binding, If you need additional information concernung this matter; please contact Dee Browder at (704) 663 1699. cc: Mooresville Regional Office, Collection System Pe Surface Water Protection Central Pipes Coleen H, Sullins it Piles Pr' NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to'the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once•per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 This pernnit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may e of be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled sc as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T 0113, upon completion cf construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form, A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. A ,copy of the construction record drawings shall be n°taintalned on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and tIimiitations contained in this permit; 15A NCAC 2T: the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable: and other supporting materials may subject the Permittee to an enforcement action by the Division in accerdance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fai to perform sat,isfactorlly, i ncludsng the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Divisions such as the construction of additional or replacement facilities„ The Isance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulation, or ordinances that may be 'imposed by other government agencies (local, state and federal) which have jurisdiction, including but notlimited to applicable river buffer rules in 15A NCAC 2B _0200, erosion and sedimentation control requirements in 15A NCAC Ch 4 and under the Division's General Permit NCG010000. and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2Fl _0500, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number ("0) 663-1699, as soon as possible, bit in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 13th day of August, 2010. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION • for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0034930 1 Fast Track Engineering C Permit No. WQ0034930 August 13, 2010 OwneriWQCSNW TP Mark Garbark Union County 500 North Main St, Suite 500 Monroe, NC 28112 ertification PE Clinton Lawrence Lawrence Associates, PA PO Box 1014. Monroe, NC 28111 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Richard Wray Keziah, a Union County project for the Permitted, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/Permittee: a. Union County Public Works Full. Legal Name (company, municipality, HOA, utility, etc) . _ Mike Garbark (Assistanttor of Enr ineerrn9 .._ _... b. G�rbark.. Director n Signing Official Name and Title (Please review 15A NCAC 2T ,0106 (b) for authorizedsigning officials!) The legal entity who will own this system is, ❑ Individual ❑ Federal ❑ Municipality E State/County ❑ Private Partnership ❑ Corporaton ❑ Other (specify), Application Number: (to be completed by DWQ) d. 500 N. Main Street, Suite 500 Mailing Address NC State 1h, 7a_4-296-421t� Telephone Project (Fa, )ll,) lnforma Richard Wray Keziah Sanitary Sewer Extension Brief Project Name (permit will refer to this name Contact Person: Mike Garbark, PE Name and Affiliation of Someone Who Can Answer Questions About this Application b. 704-296 4239 Phone Number 704-296-4232 Facsimile�� 1e, Monroe City 28112 Zip Code E-mail 2b. Union County Where Projec 3c. rnikegarbarkc@co.union.nc.us E-mai New ❑ Modification (of an existing permit) tf Modification, Pemnit No.: Public (skip to item B(3)) ❑ Private (go to if private, applicant will be: ❑ Retaining Ownership (Le, store„ church, single office, etc.) or © Leasing units (lots, townhomes, etc, - skip to item 8(3)) Selling units (lots, townhomes„ etc. - go to Item B(2b)) Union County Owner of Wastewater Treatment Facility a. Twelve Nye Creek -.... eek Name of WWTF .,a .. Union County 5b. Owner of Downstream Sewer Receiving Sewer Sze The crrgin of this wastewater is (check all that apply): tem 2(a)) If sold, facilities owned by a (mu ❑ Public Utility (Instruction C) ❑ Homeowner AssocJDeveloper (instruction D) eating Wastewater From This Projec 4b, NC 0085359 ❑ Residential Subdivision Ei Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office WWTF Permit No. vity 5c WQ0012167 , w....y�_ Force Main Permit # of Downstrea ❑ Retail (Stores, shopping centers) ❑ Institution ❑ Hospital ❑ Church Ej Nursing Home El Other (specify); Residence house ton E) % Domestic//Commercial % Industrial (attach description,) (RO: contact your Regional Office Pretreatment staff) % Other (specify'): Volume of wastewater to be allocated or permitted for this particular project: 285 gallons per day *Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit No, ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .6303 to determine if a permit is required) FTA i' 2'07 '9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T ,0114 for;, the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item 6(7). Values other than that in 15A NCAC 2T 0114 (b) and (c) must be supported with actual water or wastewater use( data in accordance with 15A NCAC 2T .0114 (f). 10 Summary of Sewer Lines to be Permitted (attach additional' sheets if necessary) Size (inches) 8 Length (feet) 63.65 _. ......................... New Gravity or Additional Force Main Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID Design Flow (MGD) Operational Poln GPM @TDH If chosen - as shown on plans/map for reference) Power Reliability Option - permanent generator MATS; 2 - portable generator w/MTS Force Main Size Force Main Length; p Station Location ID (self chosen - as shown on plan Design Flow (MGD) Operational Point Power Reliability Option GPM @TDH - permanent generator w/ATS; ' Force Main Size Force Main Length 2 - portable generator w/MTS map dr reference p Station Location ll l (self chosen - as shown on plant Design Flow Power Reliability Option (MGD) Operational Point; 1 - permanent generator w/ATS; Force Main Size GPM @TDH 2 - portable generator w/MTS p for Force Main Length; Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? Yes No If Yes, permit number of 2`i° treatment facility i(RO — if eyes" to 6,12 please contact the Central Office PERCS Unit) 3. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? E Yes No If No, please reference the pertinent minimum design crrteria or regulation and indicate why a variance is requested, SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12'07 Have the following permits certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? n Yes Z No Q N/A Sedimentation and Erosion Control Plan? • Yes No © N/A Stormwater2 El Yes ® No 'Li[ N/A Does this project include any high priority lines, [see 15A NCAC 02T .0402(2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: Eland provide details Owner/Permittee°s Cectifi nature of Signing Official and Project Name) I, Mike Garber* , attest that this application for Richard Wray Keziah Sanitary Sewer Extr ion has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included,, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation„ or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed' $10 000 as w 11 as civil penalties up to$25,000 per violation. Signing ignature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY °TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T .0305 Date Professional Engineer's Certification; (Signature of Design Engineer and Project Name) I, Clinton D, Lawrence attest that this application for Richard Wray Keziah Sanitary Sewer Extension has been reviewed by! me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Critena for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal ,signifies that I have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215.6A and 143-215, 68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. a. Clinton D. Lawrence Professional Engineer Na ence .Associates, PA Engineering Finn 2c, PAD. Box 1014 Mailing Address d, Monroe 2e.. NC City�.. _.��..._e�e..._�..�_... State 2f. 28111 Zip 704.289-1013 2h, 704-283-9035 2i clint'c@�lavrrencesurveyin€ ,com Telephone Facsimile E-mail NC PE Seal sjgnature ©ate FTA12 07 * ) *0 N *00 OP .00 *9C.0 N *00 OZ. vt0 *St° N „00 0 IZO *SSO „-* *0" rwp:ov. ' ! 0 0 0000 4** Aortat.e*rn 4 . ,:*,,,,:::' :: . : : 1 i N 400'0* ,C0 .0E0: ' ' : ' ' 'N *0004 .,:e0 AE0' ' ' N 1.000 «CO' *9E0 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit ,A‘riplications (FTSF, 10/07) Project Applicant Name: Union County Project Name for which Ilow is being requested: Richard Wray Keziah Sanitary Sewer f:xtension fore than one FTSE-10'07 ThJ f required for 4, single prOjeCI 1/ the OlVtler o/ the WIFTP is nor responsible tor all primp siations along the r(inte thC propoced W,.:ISIcWaler flow I. Complete this section only itvOU are the owner of the Wastewater treatment plant, a. WWII) Facility Name: Twelve Mile Creek h. ww-rp Facility Permit #: NC00853.59 c. WWII) facility"s permitted flow All tlow,s are in IVIGD 6,0000 d. Estimated obligated flow not et tributary to the W 1.56 e. WWII) facility's actual avg, How 17. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 3,55 0.0003 5, 85.17 IL Complete this section for each pump station goatare responsible for along the route of this proposed wastewater flow. List pump stations located betv,.'een the project connection point and the W-WIP Pump Station Name None .Approx. Capacity, NIGL) Approx. Current Avg. (Firm/Design) Daily Flow. MGD III. Certification Statement: 1, Mike Garbark eertifY that, to the best of my knowledge, the addition of the volume of wtistewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated 1,0 Cause any capacity related sanitary' sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, This analysis has been perfOrmed in accordance with local established policies and procedures using the best available data, 'Fhis certification applies to those items listed above in Sections I and 11 tOr which I am the responsible party, Signature of this form indicates acceptance of this atei n v reial Sigattu UNION COUNTY PUBLIC ORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: Regarding: Sanitary Sewer to serve Richard Wray Keziah Sanitary Sewer Extension We are sending you: r Copy of letter 1 Plans Prints Shop Drawings frA Other Date: 8/6/10 Copies Date No. Description 1 7/29/10 -------- Non-Discahrge Permit Application 1 1 7/29/10 Copy of Non -Discharge Permit Application 8/5/1 0 Sewer Flow Tracking Form 7/28/10 10 11 $480,00 Check (Application Fee) These are transmitted as checked below: For approval Remarks: Signed: For your use As requested For review and comments Received by: Date: Permit Number WQ0034930 Central Files: APS SWP_ 08/16/10 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Coastal SW Rule Permitted Flow 286 Facility Facility Name Richard Wray Keziah Sanitary Sewer Extension Location Address Owner Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Dates/Events Orig Issue App Received Draft Initiated 08/13/10 08/09/10 Scheduled Issuance Owner Affiliation Mark Eugene Tye 500 N Church St Ste 500 Monroe Public Notice Issue 08/13/10 NC 281124730 Effective Expiration 08/13/10 Regulated Activities Re • uested!Received Events Private residence, single family Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin Fast Track Engneerin Ce Permit No. WQ0 34 3 sAugust. 13; 2010 Owneril Wi 0S3W/TP Mark Garbork Union County 5U0 North Mo r St; Sustw 5 C Monroe., NC 2tt "I 1 cation PE Clinton Lawrence Lawrence Asr,cciates, PA PO kscx 101 ,, Monroe; NC 28 ? 1 1 Crurnoplete and subm0 ,his fora to the per* ilr sung One copy of the project retort drawings (plans system extension Supporting design calculations ed pumps, syst generators) or storage greater' than rgest past t.hre stations permitted as part of this pray Changes to the project should be clearly Identified on t modrfycat)t rrs are required for anLchanges resultiugiri inrpum desgr ciao ta, ,al office with the following views • sev'r lines m curve, operating point, available storage if portable year outage reliability option selected) for .any pump record drawings or in written summary form, Fermis n_cpm,Zliance vit this _permit, re3ulations or This pro cot shall not be considered co nplete nor allowed to operate until this Engineers Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, authcrlred to observe d p County project for the Perm observation of the constructi this permit; 15A NCAC 2T; the February 12i, 1996 as applic,abie, Stations and Force Mains adopte North Carolina Professional Er seal, signature, and date. ENGINEER'S CERTIFICATION Li Partial Vrnal as a duly r egistered Profes iodically, L } nerekly; [1 full tir d, hereby state that, to the ces h that the construction was Engineer in the 4ta'le of North Carolina, having been the construction of Richard Wray Kezi ah, a Union my abilities, due care and diligence was used in the bserved to be built within substantial compliance of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted Division's Minimum Design Criteria for the Fast -Track Permitting of Pump ne 1, 2000 as applicable; and other supporting materials. eer`ss SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 Tne Permittee Is responsible for tracking all parts; eertifr,,ations up until a final certification is erei ° wastewater flow made tributary- to the water collection systcio extensi ail prior to completion sn Engineer's Certification shall be considered a violation of the permit and shall subject the Perm€ttee enforcement actions. d_ Any this to appro UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 OFFICE TRANSMITTAL Attention: Dee Browder Regarding: Engineer's Certification for Richard Keziah - Sewer Extension We are sending you: Q Copy of letter Other Date No, [ Description Plans E Record Drawings Engineer's Certification for Sewe 3nl/cva li a ,, n A Date: 12/2 /10 Prints [1 Shop Drawings These are transmitted as checked below: D For approval Remarks: Signed: Received by: Permit # WQ0034930 For your use 0 As requested 0 For review and comments Date: