Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0034240_Regional Office Historical File Pre 2018
Beverly Eaves Perdue Governor Mr. Bruce Bleiman, Manager B&H Holdings, LLC 5960 Fairview Road, Suite 400 Charlotte, NC Dear Mr. Bleiman, ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Dee Freeman Director Secretary July 31, 2009 Subject: Permit No. WQ0034240 Waxhaw Retail Village Wastewater Collection System Extension Union County, North Carolina In accordance with your complete application received on July 27, 2009, we are forwarding herewith Permit No. WQ0034240, dated July 31, 2009, to B&H Holdings, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1-877-623-6748 Internet: www.ncwateroualitv.orq An Focal Onnortunity 1 Affirmative Action Emolover — 50% Recycled/10% Post Consumer eaoer No thCarolina aturall, Mr, Blejrnan Page 2 ,.14 31, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 658 linear feet of 8-gravity sewer and the discharge of 27,500 gallons per day of domestic wastewater into the existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit, The sewage ancf wastewater collected by this system shall be treated in the 12-Mile VVWTP (NPDES No.NC0085359) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and VVVVTP is the complete responsibility of Union County Public Works, Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00054, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this 663-1699. pease contact Dee Browder at (704) Sincerely, for Coeen H. Su ins cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become Voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4, This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116 upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part l of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the probiem does not recur. Part ii of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 31st day of July, 2009. • NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0034240 • 3 ast Track Engineering C Permit No. WQ0034240 July 31, 2009 OwneriWQCS Bruce Bleiman, Manager B&H Holdings, LLC 5960 Fairview Road, Suite 400 Charlotte, NC 28210 ertification WQCSNVWTP Scott Huneycutt Union County 500 North Main St, Suite 500 Monroe, NC 28112 PE James Basinger Stewart Engineering, Inc. 200 S. College Street, Suite 720 Charlotte; NC 28202 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest,past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended . that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professiohal Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Waxhaw Retail Village, a Union County project for the Permitted, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's. seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESViLLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner/P Full Legal Name (cornpan, runicipality, HOA, utility, etc.) lb,.(r� Signing The legal en 0 Individual Mailing Address t ti State. Telephone Protecacill e and Title (P ease review 15A Application Number: (to be completed by DWQ AC 2T .0105 (b vho will own this system is;. Federal 0 Municipality 0 State/County 0 Private P l3rief Project Name Contact Person: Name and Affiliation o 3b. Phone Number Project is XNew Facsimile ation: t! ". mill refer tona Somed'ne 2b el County uthorized signing officials! hip 0 Corporation Other (speci( here Project is Located r Questions About this Application E-mail edification (of an existing permit) Owner is 0 Public (skip to Item 8(3)) 2a. If private, applicant will be: Retaining Ownership (i,e. store, church, single office, etc.) easing units (lots, townhomes, etc. - skip to item B(3)) erring units (lots, townhomes, etc. - go to Item B(2ib)) Owner of Wastewater Trtm rt Facility (W 4a ( { odification, Permit No.: Private (go to item 2(a)) 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction G) 0 Homeowner Assoc./Developer (Instruction D) TF) Treating Wastewater Fr j(j;""` t'v`':)j5b. Gravity 5c Owner of Downstream Se 'Receiving Sewer Size;© Force Main The origin of this wastewater is (check all that apply): 0 Residential Subdivision 0 Apartments/Condominiums 0 Mobile Home Park 0 School Restaurant Office This Project TF Permit No. Perm Retail (Stores, shopping centers) Institution o Hospital 0 Church 0 Nursing Home © Other (specify):_ of Downstream Sewer (Instruction E)1 Domestic/Comrnercia Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) " a Other (specify): Volume of wastewater to be allocated or permitted for this particular project:'` gallons per day `Do not include future flows or previously permitted allocations if the permitted flow is zero, indicate why: Pump Station, ©utfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 12/07 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0 the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being request Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater u data in accordance with 15A NCAC 2T .0114 (f).. 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 1. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets a necessa Pump Station Location ID Design Flow (MGD) Operational Point GPM @TDH chosen - as shown on plans/map for re Power Reliability Option - permanent generator wWATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Loca Design Flow (MGD) Operational Point GPM @TDH (self chosen - as shown on planslmap for reference) Power Reliability Option - permanent generator wWATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID Design Flow (MGD) Operational Poin GPM @TDH (self chosen as shown on plans/map for reference) Power Reliability Option - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 2. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? © Ye (RO f Yes, permit number of 2nd treatment facility yes" to 8,12 please contact the Central Office PERCS Unit) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? Yes 0 No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA t 2/d7 e following permits/certifications been submitted for approval for the system or project to be served? WetlandlStrearn Crossings - General Permit or 401 Certification? © Yes © No N/A. Sedimentation and Erosion Control Plan? Yes [) No 0 N/A Yes ©No O N/A Stormwater? Does this project include any high priority lines, [see 15A NCAC 02T ,0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months heck if Yes: D and provide details Grier/Perittee` Certification: (Signature of Signing Official and Project Name) s�tl�i t 1', attest that this application for r t i �t has been reviewed by me and i accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10.000 as well as civil penalties up tee $25,000 per violation. Signing Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) -"�� 4"! tli" , attest that this application for O► 4 A {-e, kti has been reviewed by me and is acc ate, omptete and consistent with the information in the engineering plans, cal ulations, and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria€ for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: in accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly' makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. ..)I"„... . Telephone Fac NC PE Seas, Signature & Gate FTAI2/07 Courtesy of the USGS Send To Printer Back 'To TerraServer Change to 11)(1? Print Size Show Grid Lines Change to Landscape MUSES 1 km N of Waxhaw, North Carolina, United States 01 'Jul 1993 Image courtesy of the U,S. Geologic& Survey 2004 Microsoft Corporation. Terms of Use Privacy Statement Page 1 of 1 http://terraserver-usa.com/Printimage.aspOT=2&S=1.:2&Z=17&X=653&Y=4832&W.1 (cals=alma+blvd'707„. 8/4/2008 PIPPIPIFF-7/7/2009 12:40 PM USE BREAKDOWN Waxhaw Retail Village Estimated Sanitary Sewer Demand Computations Prepared By: James R. Baysinger II , P.E. Stewart Engineering, Inc. Restaurant Office Retail Square Feet gpoll5 Sq. Ft. gpd Employees gpd/Empl. gpd Square Feet gpd/1000 Sq. Ft. gpd Building 1 1390 40 3700 20 25 490' 4850 130 630 Building 2 830 40 2200 12 25 29D 2850 130 370 Building 3 830 40 2200 12 25 290 2850 130 370 Building 4 1160 40 3100 16 25 410 4000 130 520 Building 5 900 40 2400 13 25 320 3150 130 410 Building 6 1800 40 4800 26 25 650 6460 130 840 Building 7 1010 40 2700 14 25 350 3540 130 460 7920 21100 113 2800 27700 3600 SUMMARY: Restaurant: 7920 Square feet (540 Seats) x 40 gpd per 15 square f eet = 21100 gpd Office: 113 employees x 25 gallons per employee per day = 2800 gpd Retail: 27,700 square fie et x 130 gallons per 1000 square feet per day = 3600 gpd NOTES: TOTAL= 27500 gpd 1. Rates Based on 15A NCAC 2T .1114 Wastewater Design Flow Rates 2. Square Feet of Restaurant and Retail use and number of E mployees are preliminary estimates and are subject to change. The breakdown above presents approximate distribution within the project of the Sewage Flow Allocation provided by Union County as per the letter from Richard P. Black, Interim county Manager, dated January 23, 2008. Sewage Capacity may be redistributed within the project, but the total Sewage Flow from the project shall not exceed 27,500 gpd. 3. Values are estimated and include rounding of v alues to appropriate precision. Square feet of Restaurant and Retail space is rounded to the nearest 10 square feet. Gallon per Day (gpd) Is rounded to the nearest 10 gpd in the breakdown and to the nearest 100 gpd in the summary. James R. Baysinger II, PE Date NC PE: #34628 Q:\PROJECTS120081X8014 Waxhaw Retail Village\CALCSIWater and Sewer Demand Estimation 2009 July 07 SEI Project #X8014.00 State of North. Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension P -rah APppe o (FTSF�-10/07)i Project Applicant Name: Union County .. Project Name for which flow is being requested: Waxhaw Retail Village More than one FTSE-10/07 may be required.for a single project they owner o WWTP is not respons pump stations along the route of"the proposed wastewater I. Complete this section only if you are the owner of the a. WWTP Facility Name: Twelve Mile Creek b. WWTP ,Facility Permit #: NC0085359 c. WWTP .facility's pertnittcd flow d. Estimated obligated flow not yet tributary to the W" VTP e. WWTP facility's actual avg. flow. f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used. All flows are in MGD 6.0000 5324 32 0.0275 4.88 81..33 I. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name None Approx. Capacity, MGD Approx. Current Avg. (Firm./Design) Daily Flow. MGD III Certification Statement: I, Mike Garbark , certify tfrat, to the best ofmv knowledge, the addition of the volume of wastewater to be permitted in this project has been. evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form. indicates acceptance of this,, wastewater flow, b Signing Official Signature Date Permit Number WQ0034240 Central Files: APS SWP 07/31/09 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Coastal SW Rule Permitted Flow 27500 Facility Facility Name Waxhaw Retail Village Location Address Owner MajorlMinor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name B & H Holdings LLC Dates/Events Owner Type Non -Government Owner Affiliation Bruce Bleiman 5960 Fairview Rd Charlotte NC 28210 Orig Issue App Received Draft Initiated 08/01/09 07/27/09 Scheduled issuance Public Notice Issue 08/01/09 Effective Expiration 08/01/09 Regulated Activities Re ' uestedlReceived Events Office Additional information received Restaurant Retail Wastewater collection Outfall NULL Additional information requested Waterbody Name Stream Index Number Current Class Subbasin ON CO TY PUB IC WORKS July 24, 2009 Mr. James R. Baysinger Stewart Engineering, Inc. 200 South College Street Suite 720 Charlotte, N.C. 28202 Re: Sewer Treatment Capacity Private Gravity Sewer to serve Waxhaw Retail Village Dear Mr. Baysinger: Union County Public Works Department can accept the additional discharge of 27,500 gallons per day of domestic wastewater from this project for transmission to the Twelve Mile Wastewater Treatment Plant (NPDES permit number NC0085359) for treatment. This allocation is intended to serve the above mentioned project. If you have any questions please don't hesitate to call. Sincerely: Mike Garbark, P.E. Assistant Director MG/pwb 500 North Main St., Suite 500 • Monroe„ NC 28112-4730 • Phone: (704)296-4210 • Fax: (7d34)296-4232 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C. 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve Waxhaw ReailVillage (Private) We are sending you: Da Di 7/24/09 Copy of letter n Plans D Prints C Shop Drawings Other Copies Date No. Description Original Non -Discharge Permit. Application Copy of Non -Discharge Permit Application 6/30/09 1068 Check for $480.00 (Application Fee) 7/24/09 Flow Tracking Form 7/24/09 Sewer Capacity Letter These are transmitted as checked below: For approval (— For your use As requested D For review and comments Remarks: Signed: Received by: Date: ina Secretary of State Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29622 Raleigh, NC 27626-0622 (919)807-2000 CORPORATIONS Corporations Home Search By Corporate Name Search For New & Dissolved Search By Registered Agent Important Notice Resale of Tickets Online Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Unincorporated Non -Profits Dissolution Reports Non -Profit Reports Verify Certification Online Annual Reports LINKS & LEGISLATION KBBE B2B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Professional Corporations NCSOS Authority to Dissolve Register for E-Procurement Dept. of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division TOOLS Secretary of State Home Secretary of State Site Map Printable Page Date: 7/30/2009 Click here to: View Document Filings l Sign Up for E-Notifications an Annual Report l Print apre-populated Annual Report Form I Annual Report Count l File Corporation Names Name Name Type NC B & H Holdings, LLC Legal Limited Liability Company Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent Agent Name: 0702909 Current -Active 12/15/2003 Domestic NC 01/01/2035 Bleiman, Bruce L Registered Office Address: 5960 Fairview Road, Suite 400 Charlotte NC 28210 Registered Mailing 5960 Fairview Road, Suite 400 Address: Charlotte NC 28210 Principal Office Address: 5960 Fairview Road, Suite 400 Charlotte NC 28210 Principal Mailing Address: 5960 Fairview Road, Suite 400 Charlotte NC 28210 http://www.secretary.state.nc.us/corporations/Corp.aspx?PitemId=6168540 7/30/2009