Loading...
HomeMy WebLinkAboutWQ0032696_Regional Office Historical File Pre 2018OOow A r-RQG -i Ms. Christie Putnam Union County Public Works 500 N. Main Street, Suite 500 Monroe, NC 28112 Dear Ms. Putnam, Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins; Director Division of Water Quality February 8, 2008 Subject: Permit No. WQ0032696 AutoBell Full Service Car Wash Wastewater Collection System Permit Union County, North Carolina In accordance with your application received on January 30, 2008, we are forwarding herewith Permit No. WQ0032696, dated February 8, 2008, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operatdd and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 30! Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal OpportunitytAffirmative Action Employer— 50% Recycled/10% Post Consumer Paper o ` NthCarolina ,Naturally PrrMs.Putnam Page 2 February 8, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 1,099 linear feet of 8-inch gravity sewer and the discharge of 2,300 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received November 13, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's Crooked Creek WWTP (NPDES No. NC0069841) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. if you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. S erely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files William B. McAnaliy, Taylor Wiseman & Taylor, Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties 'involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Irr- Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 8th day of February, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032696 3 PPP,' Fast Track Engineering Permit No. WQ0032696 •February 9, 2008 OwnerNWVrP/WQCS Ms. Christie Putnam Union County Public Works 500 N. Main Street, Suite 500 Monroe, NC 28112 Certification PE William B. McAnally • Taylor Wiseman & Taylor, Inc. 700 Forest Pont Circle, Suite 116 Charlotte, NC 28273 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (D periodically, ❑ weekly, ['full time) the construction of AutoBell Full Service Car Wash, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. z 0 0 APPLIC A'TIC N for RA T% S WERS, PUMP S'IAT1ONS, ; Nil FORCE MAIN'S USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: la. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) 1b, Christie L. Putnam, Director, Union County Public Works Application Number: (to be completed by DWQ) PAGE 3 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing offcials!) The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality State/County 0 Private Partnership OCorporation 0 Other (specify): ld. 500 N. Main Street, Suite 500 Mailing Address City 1f. NC 1g. 28112 State Zip Code 1 h. 704-296-4210 1 i. 704-296-4232 Telephone Facsimile E mail 2. Project (Facility) Information: 2a. AutoBell Full Service Car Wash__ 2b, Union Brief Project Name (permit will refer to this his name " 3. Contact Person: ,Q 3a. Mike Garbark, Asst, Director, Union Co, Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-296-4239 3c, mikegarbark@a ca.union.nc.us e. Monroe • County Where Project is Located Phone Number E-mail 1. Project isNew 0 Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.)„ Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is } Public (skip to (tern B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one 0 Retaining Ownership (i.e. store, church, single office, etc,) or 0 Leasing units (lots, townhomes, etc, - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to item B(2b)) Union Co. Public Works Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Proje 4a. Crooked Creek Name of WWTF LL 5a, _Union Co. Public Works '5b. 8" ® Gravity Owner of Downstream Sewer Receiving Sewer Size 0 Force Main 6. The origin of this wastewater is (check all that apply): O Residential Subdivision 0 Apartments/Condominiums O Mobile Home Park O School 0 Restaurant Office Car Wash 0 Institution O Hospital O Church O Nursing Home O Other (specify): 0 Public Utility (Instruction ill) 0 Homeowner Assoc./Developer (Instruction IV) 4b. NC0069841 WWTF Permit No. W Q0020130 Permit Number of Downstream Sewer (if known 100 % Domestic/Commercial % Industrial % Other (specify): Volume of wastewater to be allocated for this particular project: 2300 gallons per day "Do not include previously permitted allocations 8, If the permitted flow is zero, indicate whys 0 Interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected 2/03 - Rev, 3 04/05 VPPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE4 W Z 1= Z 0 U Z 0 1- 2 Le 0 IL Z de the wastewaterflow calculations used in determining the permitted flow in accordance with 15A NCAC 2H (1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). Carwash 1,400 gal/day, Restrooms 200 gal/day, Retail Store 700 gallday, Total 2,300 gal/day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8" • ENTER TOTAL LINE LENGTH IN MILES Length (feet) 1,099 0.208 Gravity or Force Main (use the pull down menu) Gravity 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID ; Power Reliability Option (self chosen - as shown on Design Flow ! Operational Point 1 (1- dual line feed; 2- permanent generator w1ATS; 3- plans for cross-reference) _ (MGD) I GPM @ TDH portable -generator wltelemetry; 4-wet well storage) 2 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force WW Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS Cli PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ❑ Yes ® No ❑ N/A Stormwater? ® Yes ❑ No ❑ N/A 14. Does this project involve aerial lines or siphons? Check if yes: ❑ These lines will be considered. hiah Priority and must be checked onceeverv-sixmonths- 15. Does this project have gravity sewer lines designed at minimum slopes? ❑ Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 PAGE 5 ,K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 0 F. C. STREAM C 0 Z A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) Name of Waterbody Stream Waterbody Waterbody County River Basin Index Classification Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1, Applicant's Certification: 1, Christie L. Putnam , attest that this application for AutoBell Car Wash has been reviewed by me and is accurate and complete to the best of my knowledge, understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall fr9uilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $2 r violation, Sgn1fOfficiaI Signature 2. Professional Engineer's Certification: attest that this application for AutoBell Car Wash has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge.. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the! Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professional's, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note!: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any falSestatement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. William B. McAnally, P.E. Professional Engineer Name 2b. Taylor Wiseman & Taylor, Inc, Engineering Firm 2c. 700 Forest Point Circle, Ste. 116 5 i • : Mailing Address 3 : 2d. Charlotte 2e. NC 2f. 28273 •,....•• ''', City State Zip ,-8 2g, 704-527-2535 2h. 704-527-2537 2i, bmcanally@taylorwiseman.com Telephone Facsimile E-mail Seal, Signature & Date FTA. 02/03 - Rev. 3 04/05 USGS QUAD MAP: MAI I HEWS INDIAN TRAIL AUTOBELL SCALE: 1'" = 2000' 3114/07 • gyrate or norm uarouna Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications . _ (FTSE—10/07) • Project Applicant Name: G'Alp n,l eoc A7'y ?'V C3 L-I4;' (A) e QK S Project Name for which flow is being' requested: A ro' it3 mot. .:Poi c . - More than one FTSE-10/07 may be required for a single project if the owner, of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow.. z. I. Complete this section only if you are the owner of the wastewater treatment plant.: -' a: WWTP'Facility Name:•'• tZ o oK ets' • b.'WWTP Facility Permit #: .,' c. WWTP facility's permitted 'flow . d. Estimated obligated flow not yet tributary.to the WWTP'. e: WWTP facility's actual avg. flow £ Total flow for- this specific request ~ •" ' g. Total actual and obligated flows to the facility, h. Percent ofperrnitted f•low used - . 1644. k: - • II. Complete this section for each pump station you are responsible for along the route of this = ;: proposed wastewater flow. _ '°t' '. ' •= List pump stations located between -the project connection point and the WWTP : ,... Pump Station Name _ Approx: Capactty,lVIGD (Finn/Design) • A•pprox: Current Avg. . • Daily Flow, MGD III. Certification Statement: .- • - . 'I, /-t'2is7it' P. "Fur/km rn , certify that,'to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving ' wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving - • . treatment plant under normal circumstances: This analysis has been performed in accordance with local establi ed policies and procedures using the best available data. This certification applies to those items lis a ove in Sections I an ' II for I am the responsible party. Signature of this form indicates e of this waste r flo ring Offtcignature Date UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 Attention: TRANSMITTAL Regarding: Sanitary Sewer to serve AutoBell Full Service Car Wash We are sending you: Copies Date Date: 1/28/08 Copy of Vetter E Plans [J Prints 0 Shop Drawings Other Description 07 I Original Non -Discharge Permit Application 3/13/07 I Copy of Non -Discharge Permit Application 1/22/08 3037 Check for $480 00 (Application Fee) 1f28/08 Flow Tracking Form These are tred as checked belo NC DENR RO urfaco 'Water Prof on For approval 0 For your use Q As requested 0 For review and comments Remarks: Signed: Received by: Date: Central Files: APS SWP 02/08/08 Permit Number WQ0032696 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 individual Pr�titPSant$y+eviewer Permit Contact Affiliation dee.browder Permitted Flow 2300 Facility Facility Name Major/Minor Region Auto Bell Full Service Car Wash Minor Mooresville Location Address County Union Facility Contact Affiliation Owner Owner Name Union County Public Works Dates/Events Owner Type Government - County Owner Affiliation Christine Putnam, Director Public Works 500 N Main St Stet00 Monroe NC 281124730 Orlg Issue App Received Draft Initiated Scheduled Public Notice Issue Issuance 02/08/08 01/30/08 02/08/08 02/08/08 Effective Expiration Regulated Activities Requested/Received Events Car wash facility Additional information requested Office Additional information received Wastewater collection Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin August 7, 2008 Union County Pubic Works 500 N. Main Street Suite 500 Monroe, North Carolina 28112 SUBJECT: AutoBell Full Service Car Wash Permit No. WQ0032696 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality • The Division received a final engineering certification for the subject project on July 21, 2008: ''A full. review of the certification materials may or may not be conducted. It is assumed that receipt of- - this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://h2o.enr.state.nc.us/ndpu/ndpuapps.html#Sewer. If you have'any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sincerely, Robert Krebs Surface Water Protection Regional Supervisor Enclosure 5E-td Cc: William McAnaily, Taylor Wiseman & Taylor Surface Water Protection Section Central Fires (certification page only) North Carolina Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.nc.state.us/ndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recyced/10% post -consumer paper Fast Track ..ntljneerin icatiop M rr ;t 6 PE Therefore, .ty recomrnr9ded Fri: v d proof o rec ut by the , W EtaGir9EER S Ct RT FIC,ATiQ,N SEND THIS FORM & SUPPORTING OOCUI+IENTATION WITH UIRED ATTACHMENTS TO THE FALLOWING ADDRESS 'spons.Ve for toads de t t mt'r, to t ° W.tew° h. MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 n S received Any Perr'" to .' taJ aL`}^ro ;<'?cit , UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Attention: Dee Browder Regarding: Engineer's Certification for Auto Bell Car Wash TRANSMITTAL Date: 7/18/08 We are sending you: 1 'Copy of letter * Plans Prints [] Shop Drawings Other Copies Date 7/9/08 7/09/08 Description Record Drawings Engineer's Certification for Sewer (Permit # These are transmitted as checked below: NC N MO urfece Water Pro ectlen For approval Z For your use As requested 1 For review and comments Remarks: Signed: Received by: Date: