February 8, 2008
Subject: Permit No. WQ0032696
AutoBell Full Service Car Wash
Wastewater Collection System Permit
Union County, North Carolina
In accordance with your application received on January 30, 2008, we are forwarding herewith
Permit No. WQ0032696, dated February 8, 2008, to the Union County Public Works for the
construction and operation of the subject wastewater collection system extension. This permit shall be
effective from the date of issuance until rescinded and shall be subject to the conditions and limitations
as specified therein. This cover letter shall be considered a part of this permit and is therefore
incorporated therein by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operatdd and maintained in accordance with 15A NCAC 2T .0403 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable,
unless specifically mentioned herein. Division approval is based on acceptance of the certification
provided by a North Carolina -licensed Professional Engineer in the application. It shall be the
Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria
and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute
§143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection
facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board.
Mooresville Regional Office 610 East Center Ave., Suite 30! Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040
Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748
An Equal OpportunitytAffirmative Action Employer— 50% Recycled/10% Post Consumer Paper
o `
NthCarolina
,Naturally
PrrMs.Putnam
Page 2
February 8, 2008
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to Union County Public Works for the construction and operation of approximately 1,099 linear
feet of 8-inch gravity sewer and the discharge of 2,300 gallons per day of collected domestic
wastewater into the Union County existing sewerage system, pursuant to the application received
November 13, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum
Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and
other supporting data subsequently filed and approved by the Department of Environment and Natural
Resources and considered a part of this permit.
The sewage and wastewater collected by this system shall be treated in the Union County's
Crooked Creek WWTP (NPDES No. NC0069841) prior to being discharged into the receiving stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
if you need additional information concerning this matter, please contact Dee Browder at (704)
663-1699.
S erely,
for Coleen H. Sullins
cc: Mooresville Regional Office, Collection System Permit Files
William B. McAnaliy, Taylor Wiseman & Taylor, Inc.
Surface Water Protection Central Files
PERCS
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T
.0403:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
1
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties 'involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these
permitted facilities, the completed Engineering Certification form attached to this permit shall be
submitted with the required supporting documents to the address provided on the form. A complete
certification is one where the form is fully executed and the supporting documents are provided as
applicable.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H .0500.
11. Noncompliance Notification:
The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than
24 hours or on the next working day, following the occurrence or first knowledge of the occurrence
of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
2
Irr-
Voice mail messages or faxed information is permissible, but shall not be considered as the
initial verbal report. Overflows and spills occurring outside normal business hours may also be
reported to the Division of Emergency Management at telephone number (800) 858-0368 or
(919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by
completing Part I of Form CS-SSO (or the most current Division approved form), within five days
following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most
current Division approved form) can also be completed to show that the SSO was beyond
control.
Permit issued this the 8th day of February, 2008.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for Coleen H. Sullins, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0032696
3
PPP,'
Fast Track Engineering
Permit No. WQ0032696
•February 9, 2008
OwnerNWVrP/WQCS
Ms. Christie Putnam
Union County Public Works
500 N. Main Street, Suite 500
Monroe, NC 28112
Certification
PE
William B. McAnally •
Taylor Wiseman & Taylor, Inc.
700 Forest Pont Circle, Suite 116
Charlotte, NC 28273
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• Supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for any changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
❑ Partial ❑ Final
, as a duly registered Professional Engineer in the State of North Carolina, having been
authorized to observe (D periodically, ❑ weekly, ['full time) the construction of AutoBell Full Service Car Wash, a
Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used
in the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
z
0
0
APPLIC A'TIC N for RA T% S WERS, PUMP S'IAT1ONS, ; Nil FORCE MAIN'S
USE THE TAB KEY TO MOVE FROM FIELD TO FIELD!
Owner:
la. Union County Public Works
Full Legal Name (company, municipality, HOA, utility, etc.)
1b, Christie L. Putnam, Director, Union County Public Works
Application Number:
(to be completed by DWQ)
PAGE 3
Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing offcials!)
The legal entity who will own this system is:
0 Individual 0 Federal 0 Municipality State/County 0 Private Partnership OCorporation 0 Other (specify):
ld. 500 N. Main Street, Suite 500
Mailing Address City
1f. NC 1g. 28112
State Zip Code
1 h. 704-296-4210 1 i. 704-296-4232
Telephone Facsimile E mail
2. Project (Facility) Information:
2a. AutoBell Full Service Car Wash__ 2b, Union
Brief Project Name (permit will refer to this
his name
" 3. Contact Person:
,Q 3a. Mike Garbark, Asst, Director, Union Co, Public Works
Name and Affiliation of Someone Who Can Answer Questions About this Application
3b. 704-296-4239 3c, mikegarbark@a ca.union.nc.us
e. Monroe
•
County Where Project is Located
Phone Number E-mail
1. Project isNew 0 Modification (of an existing permit) If Modification, Permit No.:
For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another
phase, changing line size/length, etc.)„ Only include the modified information in this permit application - do not
duplicate project information in B(7) and B(10-11) that has already been included in the original permit.
2. Owner is } Public (skip to (tern B(3)) 0 Private (go to Item 2(a))
2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one
0 Retaining Ownership (i.e. store, church, single office, etc,) or
0 Leasing units (lots, townhomes, etc, - skip to Item B(3))
0 Selling units (lots, townhomes, etc. - go to item B(2b))
Union Co. Public Works
Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Proje
4a. Crooked Creek
Name of WWTF
LL 5a, _Union Co. Public Works '5b. 8" ® Gravity
Owner of Downstream Sewer Receiving Sewer Size 0 Force Main
6. The origin of this wastewater is (check all that apply):
O Residential Subdivision
0 Apartments/Condominiums
O Mobile Home Park
O School
0 Restaurant
Office
Car Wash
0 Institution
O Hospital
O Church
O Nursing Home
O Other (specify):
0 Public Utility (Instruction ill)
0 Homeowner Assoc./Developer (Instruction IV)
4b. NC0069841
WWTF Permit No.
W Q0020130
Permit Number of Downstream Sewer (if known
100 % Domestic/Commercial
% Industrial
% Other (specify):
Volume of wastewater to be allocated for this particular project: 2300 gallons per day
"Do not include previously permitted allocations
8, If the permitted flow is zero, indicate whys
0 Interceptor Line - Flow will be permitted in subsequent permits that connect to this line
0 Flow has already been allocated in Permit No.
0 Rehabilitation or replacement of existing sewer with no new flow expected
2/03 - Rev, 3 04/05
VPPLICATION
for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE4
W
Z
1=
Z
0
U
Z
0
1-
2
Le
0
IL
Z
de the wastewaterflow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than
that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A
NCAC 2H .0219(I)(3).
Carwash 1,400 gal/day, Restrooms 200 gal/day, Retail Store 700 gallday, Total 2,300 gal/day
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
Size (inches)
8"
•
ENTER TOTAL LINE LENGTH IN MILES
Length (feet)
1,099
0.208
Gravity or Force Main
(use the pull down menu)
Gravity
11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
Location ID ; Power Reliability Option
(self chosen - as shown on Design Flow ! Operational Point 1 (1- dual line feed; 2- permanent generator w1ATS; 3-
plans for cross-reference) _ (MGD) I GPM @ TDH portable -generator wltelemetry; 4-wet well storage)
2 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force
WW Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS
Cli PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
13. Have the following permits/certifications been submitted for approval?
Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A
Sedimentation and Erosion Control Plan? ❑ Yes ® No ❑ N/A
Stormwater? ® Yes ❑ No ❑ N/A
14. Does this project involve aerial lines or siphons? Check if yes: ❑
These lines will be considered. hiah Priority and must be checked onceeverv-sixmonths-
15. Does this project have gravity sewer lines designed at minimum slopes? ❑
Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be
corrected prior to submitting the final engineering certification..
FTA 02/03 - Rev. 3 04/05
PAGE 5
,K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS
1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
(FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as
necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
regional office (see instructions for addresses) OR indicate the following:
0
F.
C. STREAM C
0
Z A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope
waterbody; AND,
A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability
option for any pump station near a Class C down slope waterbody.
Location ID on Map
(self chosen - as shown on
map for cross-reference)
Name of Waterbody Stream Waterbody
Waterbody County River Basin Index Classification
Submit the 8,5" x 11" COLOR topographic map as required in Instruction VI
regardless of whether a classification is provided!
1, Applicant's Certification:
1, Christie L. Putnam , attest that this application for AutoBell Car Wash has been reviewed by me and is
accurate and complete to the best of my knowledge, understand that if all required parts of this application are not
completed and that if all required supporting documentation and attachments are not included, this application package
is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and
143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application
shall fr9uilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to
$2 r violation,
Sgn1fOfficiaI Signature
2. Professional Engineer's Certification:
attest that this application for AutoBell Car Wash has been reviewed by me and is accurate, complete and consistent
with the information in the engineering plans, calculations, and all other supporting documentation to the best of my
knowledge.. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with
the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the!
Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the
watershed classification in accordance with Division guidance. Although certain portions of this submittal package may
have been developed by other professional's, inclusion of these materials under my signature and seal signifies that I have
reviewed this material and have judged it to be consistent with the proposed design. Note!: In accordance with NC
General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any falSestatement, representation, or
certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as
well as civil penalties up to $25,000 per violation,
2a. William B. McAnally, P.E.
Professional Engineer Name
2b. Taylor Wiseman & Taylor, Inc,
Engineering Firm
2c. 700 Forest Point Circle, Ste. 116 5
i
• :
Mailing Address
3 :
2d. Charlotte 2e. NC 2f. 28273
•,....••
''', City State Zip ,-8
2g, 704-527-2535 2h. 704-527-2537 2i, bmcanally@taylorwiseman.com
Telephone Facsimile E-mail Seal, Signature & Date
FTA. 02/03 - Rev. 3 04/05
USGS QUAD MAP: MAI I HEWS
INDIAN TRAIL AUTOBELL
SCALE: 1'" = 2000'
3114/07
•
gyrate or norm uarouna
Department of Environment and Natural Resources
Division of Water Quality
Flow Tracking/Acceptance for Sewer Extension Permit Applications
. _ (FTSE—10/07)
•
Project Applicant Name: G'Alp n,l eoc A7'y ?'V C3 L-I4;' (A) e QK S
Project Name for which flow is being' requested: A ro' it3 mot. .:Poi c . -
More than one FTSE-10/07 may be required for a single project if the owner, of the WWTP is not responsible for all
pump stations along the route of the proposed wastewater flow.. z.
I. Complete this section only if you are the owner of the wastewater treatment plant.: -'
a: WWTP'Facility Name:•'• tZ o oK ets'
• b.'WWTP Facility Permit #:
.,' c. WWTP facility's permitted 'flow .
d. Estimated obligated flow not yet tributary.to the WWTP'.
e: WWTP facility's actual avg. flow
£ Total flow for- this specific request ~ •" '
g. Total actual and obligated flows to the facility,
h. Percent ofperrnitted f•low used - .
1644.
k: -
• II. Complete this section for each pump station you are responsible for along the route of this = ;:
proposed wastewater flow. _ '°t' '. ' •=
List pump stations located between -the project connection point and the WWTP : ,...
Pump Station Name _ Approx: Capactty,lVIGD
(Finn/Design)
•
A•pprox: Current Avg. .
• Daily Flow, MGD
III. Certification Statement: .- • -
. 'I, /-t'2is7it' P. "Fur/km rn , certify that,'to the best of my knowledge, the addition of the
volume of wastewater to be permitted in this project has been evaluated along the route to the receiving
' wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity
related sanitary sewer overflows or overburden any downstream pump station en route to the receiving -
• . treatment plant under normal circumstances: This analysis has been performed in accordance with local
establi ed policies and procedures using the best available data. This certification applies to those items
lis a ove in Sections I an ' II for I am the responsible party. Signature of this form indicates
e of this waste r flo
ring Offtcignature
Date
UNION COUNTY PUBLIC WORKS
500 N. Main Street, Suite 500
Monroe, NC 28112
704/296-4210
Fax 704/296-4232
To: NC Department of Environment and Natural Resources
Mooresville Regional Office
610 East Center Avenue
Suite 301
Mooresville, N.C. 28115
Attention:
TRANSMITTAL
Regarding: Sanitary Sewer to serve AutoBell Full Service Car Wash
We are sending you:
Copies Date
Date: 1/28/08
Copy of Vetter E Plans [J Prints 0 Shop Drawings
Other
Description
07 I Original Non -Discharge Permit Application
3/13/07 I Copy of Non -Discharge Permit Application
1/22/08 3037 Check for $480 00 (Application Fee)
1f28/08
Flow Tracking Form
These are tred as checked belo
NC DENR RO
urfaco 'Water Prof on
For approval 0 For your use Q As requested 0 For review and comments
Remarks:
Signed:
Received by: Date:
Central Files: APS SWP
02/08/08
Permit Number WQ0032696
Permit Tracking Slip
Program Category Status Project Type
Non -discharge Active New Project
Permit Type Fast Track Version Permit Classification
Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 individual
Pr�titPSant$y+eviewer Permit Contact Affiliation
dee.browder
Permitted Flow
2300
Facility
Facility Name Major/Minor Region
Auto Bell Full Service Car Wash Minor Mooresville
Location Address County
Union
Facility Contact Affiliation
Owner
Owner Name
Union County Public Works
Dates/Events
Owner Type
Government - County
Owner Affiliation
Christine Putnam, Director Public Works
500 N Main St Stet00
Monroe NC 281124730
Orlg Issue App Received Draft Initiated Scheduled Public Notice Issue
Issuance
02/08/08 01/30/08 02/08/08 02/08/08
Effective Expiration
Regulated Activities Requested/Received Events
Car wash facility Additional information requested
Office Additional information received
Wastewater collection
Outfall NULL
Waterbody Name Stream Index Number Current Class Subbasin
August 7, 2008
Union County Pubic Works
500 N. Main Street
Suite 500
Monroe, North Carolina 28112
SUBJECT: AutoBell Full Service Car Wash
Permit No. WQ0032696
Wastewater Collection System Extension
Final Engineering Certification
Dear Permittee:
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Coleen Sullins, Director
Division of Water Quality
•
The Division received a final engineering certification for the subject project on July 21, 2008: ''A full.
review of the certification materials may or may not be conducted. It is assumed that receipt of- -
this certification indicates compliance with all regulations, design criteria and the permit. Please be
reminded that the Permittee is responsible for keeping a copy of the final record drawings for the
life of the project. If you have not received a copy, please contact your consultant immediately to
obtain a copy.
You are receiving this letter because the Division has you listed as the responsible party. If this
permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not
automatically transferable. Form PNOCF-S can be downloaded from
http://h2o.enr.state.nc.us/ndpu/ndpuapps.html#Sewer.
If you have'any questions concerning this document or the completion of Form PNOCF-S (if
necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at
dee.browder@ncmail.net.
Sincerely,
Robert Krebs
Surface Water Protection Regional Supervisor
Enclosure
5E-td
Cc: William McAnaily, Taylor Wiseman & Taylor
Surface Water Protection Section Central Fires (certification page only)
North Carolina
Naturally
Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.nc.state.us/ndpu
1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Action Employer
Telephone (919) 733-5083 Fax (919) 733-0059 50% recyced/10% post -consumer paper
Fast Track ..ntljneerin icatiop
M rr ;t 6
PE
Therefore, .ty recomrnr9ded
Fri: v d proof o rec ut by the , W
EtaGir9EER S Ct RT FIC,ATiQ,N
SEND THIS FORM & SUPPORTING OOCUI+IENTATION
WITH UIRED ATTACHMENTS TO THE FALLOWING ADDRESS
'spons.Ve for toads
de t t mt'r, to t ° W.tew°
h.
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
n S received Any
Perr'" to .' taJ aL`}^ro ;<'?cit ,
UNION COUNTY PUBLIC WORKS
500 N. Main Street, Suite 500
Monroe, NC 28112
704/296-4210
Fax 704/296-4232
To: NC Department of Environment & Natural Resources
Mooresville Regional Office
610 East Center Avenue, Suite 301
Mooresville, NC 28115
Attention: Dee Browder
Regarding: Engineer's Certification for Auto Bell Car Wash
TRANSMITTAL
Date: 7/18/08
We are sending you: 1 'Copy of letter * Plans Prints [] Shop Drawings
Other
Copies Date
7/9/08
7/09/08
Description
Record Drawings
Engineer's Certification for Sewer (Permit #
These are transmitted as checked below:
NC N MO
urfece Water Pro ectlen
For approval Z For your use As requested 1 For review and comments
Remarks:
Signed:
Received by: Date: