Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031473_Regional Office Historical File Pre 2018
Michael F. Easley, Governor prat'n AND N" 'Ut, ,� � ��' William G *RasS 1r., Secretary North Caroli iatepartment!of Environmept andNNatural Resources r, C - �, r�: Alan—VV.-Klimek, P.E., Director Division of Water Quality March 22, 2007 Christie L. Putnam Union County 400 North Church Street Monroe, NC 28112-4804 1 MAR 2 62007 NITER QUALITYSECTIOp Subject: Permit No. WQ0031473 Union County Elementary School 'H' Gravity Sewer Extension Union County Dear Ms. Putnam: In accordance with your permit application received January 26, 2007, we are forwarding herewith Permit No. WQ0031 473 dated March 22, 2007, to Union County for the construction and continued operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations cis specified therein. Please pay particular attention to Permit Condition 3, which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0400 or any individual system -wide collection system permit issued to the Permittee. Also, note condition 5, which requires the Permittee to demonstrate that capacity exists to treat the waste at the Union County facility or that a Pump and Haul permit has been obtained for the transport of the wastewater to a facility with capacity. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC Chapter 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143- 215.6A through § 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. NorthCarolina Naturally Pretreatment, Emergency Response and Collection Systems Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 733-0059 Internet httpa/h2o.enr.nc.state.us/peres An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper Christie Putnam March 22, 2007 Page 2 All sewer related matters are handled through the Pretreatment, Emergency Response and Collection Systems Unit under the Point Source Branch EXCEPT FOR FAST -TRACK SEWER PERMITTING WHICH CONTINUES TO BE ADMINISTERED THROUGH OUR REGIONAL OFFICES. The Unit is located on the 13th floor of the Archdale building in downtown Raleigh. Please ensure the letterhead information is used for all correspondence to ensure timely delivery. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Deborah Gore at (919) 733-5083 extension 593. cc: Union C , o PERCS Files ith De 14,0,4tV44,5 artment Sincerely Alan W. Klimek, P. E. 2 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO UNION COUNTY UNION COUNTY FOR THE construction of approximately 2,848 linear feet of 8-inch gravity sewer, to serve Union County Elementary School 'H', and the discharge of 11,250 GPD of collected wastewater into the Union County Public Works' existing sewerage system, pursuant to the application received January 26, 2007, and subsequent additional information received by the Division, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations: 1. This permit shall become revocable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC Chapter 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0400: a. The sewer system shall be effectively maintained and operated at all times to preyent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in .15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. 1 d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. This requirement does not apply to pump stations serving a single building associated with a properly permitted pressure sewer system. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute § 143-215.1 C. 4. The sewage and wastewater collected by this system shall be treated in the Union County Public Works Wastewater Treatment Facility (NPDES Permit No. NC0085359) prior to being discharged into the receiving stream. 5. Construction only. No allocation currently exists for the flow represented in this permit at issuance. No flow shall be made tributary to the subject sewer system permitted herein until a permit modification has been submitted to the Division indicating that either the allocation now exists at Twelve Mile Creek WWTP (NC0085359) or that a Pump and Haul permit to a wastewater treatment facility with available capacity has been obtained. 6. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by documentation from the parties involved and other supporting materials as may be appropriate. The approval of this request will be considered on ifs merits and may or may not be approved. 7. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 8. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 9. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC Chapter 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143- 215.6A through §143-215.6C. 11. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 28 .0200 and 15A NCAC 2H .0500. 2 PIPIIIF712. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition 1(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 14. Each pump station shall be clearly and conspicuously posted with the telephone number of the owner/operator of the pressure sewer system and instructions to call the number in the event of high water alarm activation. Permit issued this the 22nd day of March 2007 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Alan W. Klimek, P. E.,•Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031473 3 Permit No. WQ0031473 March 22, 2007 System Description: approximately 2,848 linear feet of 8-inch gravity sewer, to serve Union County Elementary School 'H', Complete and submit this form to the permit issuing office as indicated below with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any chancres resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that fhis certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ['Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC Chapter 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS JEFF POUPART, UNIT SUPERVISOR PRETREATMENT, EMERGENCY RESPONSE & COLLECTION SYSTEMS UNIT 1617 MAIL SERVICE CENTER RALEIGH NC 27699-1617 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 4 Michael F, Easley, Governor Witham G. Ross Jr„ Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality March 22, 2007 Christine L. Putnam, PE Director, Union County Department of Public Works 400 North Church Street Monroe, NC 28112-4804 Subject: Acknowledgement of Application No. WQ0031473 Union County Public Schools: Elementary "H" Wastewater Collection System Extension Union County Dear Ms. Putnam: 6 200'7 The Division of Water Quality (Division) acknowledges receipt of your permit application and supporting materials on December 5, 2005. This application package has been assigned the number listed above and will be reviewed by Jeff Poupart. The reviewer will perform a detailed review and contact you with a request for additional information if necessary. To ensure the maximum efficiency in processing permit applications, the Division requests your assistance in providing a timely and complete response to any additional information requests, Please note at this time, processing permit applications can take as long as 60 - 90 days after receipt of a complete application. To check on the status of an application, please visit hffp:.//h2o.enr.state,nc,us/biros/Reports/reportsPermits.html, The Division has recently reorganized. All sewer related matters are now handled through the Pretreatment, Emergency Response and Collection Systems Unit under the Point Source Branch EXCEPT FOR FAST -TRACK SEWER EXTENSION PERMITTING WHICH CONTINUES TO BE ADMINISTERED THROUGH OUR REGIONAL OFFICES. The Unit is located on the 13th floor of the Archdale building in downtown Raleigh. If you have any questions, please contact Jeff Poupart at 919-733-5083, extension 527, or via e-mail at jeff.poupart@ncmail.net. If the reviewer is unavailable, you may leave a message, and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRIES ON THIS PROJECT. Sincerely, Supervisor cc: Mooresville Regional Office, Surface Water Protection Section Brian J Dey, PE McKim & Creed, 8020 Tower Point Drive, Charlotte, NC 28269 Permit Application File WQ0031473 Pretreatment, Emergency Response and Collection Syst 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 733-0059 s Unit Internet httpi/h2o.enr.nc.state.us/ndpu An Equal Opportunity Action Employer 50 recycled/10% post -consumer paper Permit No. WQ0031473 July 17, 2007 ENGINEER'S CERTIFICATION Partial Final I, Brian J. Dey, PE , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to (E periodically, weekly, full time) observe the construction of the Gravity Sewer to Serve Elementary School H, Union County, North Carolina), for Manholes number 15 & 16, for the Permittee hereby state that, to the best of my abilities, due care and diligence were used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .4200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains adopted June 1, 2000, last amended on. September 1, 2006, as applicable; and other supporting materials. North Carolina Profes n Engineer's seal, signature, and date. SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS: MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVE, SUITE 301 MOORESVILLE, NC 281 15.095© UNION COUNTY PUBLIC WORKS. 400 N. Church Street Monroe, NC 28112-4804 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 919 North Main Street Mooresville, N.C. 28115 Attention: Dee Browder TRANSMITTAL Date: 7/23/07 Regarding: Engineer's Certification for SCHOOL "H"/ WAXHAW-INDIAN TRAIL (Partial Certification) We are sending you: ❑ Copy of letter ❑ Plans ❑ Prints ❑ Shop Drawings ® Other Copies Date No. Description 1 7/17/07 Record Drawings 1 7/17/07 Engineer's Certification for Sewer (Permit # WQ0031473 AND NATURAL nonnif 11DQRESV1LLE {{ r per. - IF;'' JJqq .. _ . " - { 94t 4-7 i These are transmitted as checked below: WATERWAIERQUAWYSECTION ❑ For approval ® For your use ❑ As requested ❑ For review and comments Remarks: Signed: Received by: Date: