HomeMy WebLinkAboutWQ0031192_Regional Office Historical File Pre 2018Michael1-
rmr G. Ross Jr, Secretarti
epartnof Environment and Natu rat Resources'
Coleen FY. "Sullins, Director
Division of Water Quality
October 23, 2007
Ms, Christie Putnam, P.E., Director of Public Works
Union County Public Works
500 North Main Street
Monroe, NC 28112
Subject: Permit No. WQ0031192 Modification Li)
Fieldstone Farms Subdivision
Wastewater Collection System Per
Union County Public Works
Union County, North Carolina
Dear Ms, Putnam,
In accordance with your application received on October 9, 2007, we are forwarding herewith
Permit No, WQ0031192, dated October 23, 2007, to the Union County Public Works for the
construction and operation of the subject wastewater collection system extension. This permit shall be
effective from the date of issuance until rescinded and shall be subject to the conditions and limitations
as specified therein. This cover letter shall be considered a part of this permit and is therefore
incorporated therein by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for
the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable,
unless specifically mentioned herein. Division approval is based on acceptance of the certification
provided by a North Carolina -licensed Professional Engineer in the application. It shall be the
Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria
and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute
§143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection
facilities„ and/or referral of the North Carolina -licensed Professional Engineer to the licensing board.
Moores e Regional Office 61.0 East. Center A e , Suite 3t71 MooresvilleInternet: www.ncrnwaterqualibiurg Customer Service: 1-877.623-6741I
An Equal Opportunity/Affirmative Action Employer— 50'/Q Recycled/10% Post Consumer Paper
Phone- (704) 663-1699 Fax (704) 663.6040
One
NorthCarolina
; aturaillf
Putnam
Page 2
October 23, 2007
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to Union County Public Works for the construction and operation of approximately 25,576 linear
feet of 8-inch gravity sewer, approximately 2,761 linear feet of 12-inch gravity sewer, approximately
4,305 linear feet of 6-inch force main and a 350 gallon per minute pump station with duplex pumps, on -
site audible and visual high water alarms, and an on -site generator with automatic transfer switch and
the discharge of 138,510 gallons per day of collected domestic wastewater into the Union County
existing sewerage system, pursuant to the application received October 9, 2007, and in conformity with
15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as
applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and
Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and
approved by the Department of Environment and Natural Resources and considered a part of this
permit. _
The sewage and wastewater collected by this system shall be treated in the Union County's
Twelve Mile Creek VWVfP (NPDES No. NC0085359) prior to being discharged into the receiving
stream.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150E of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
If you need additional information concerning this matter, please contact Dee Browder at (704)
663-1699.
Sincerely,
for Coleen H. Sullins
cc: Mooresville Regional Office, Collection System Permit Files
Jason Sessler, Stantec Consulting Inc.
Surface Water Protection Central Files
PERCS
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance -of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T
.0403:
a. The sewer system shalt be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 21_ .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shall be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
1
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these
permitted facilities, the completed Engineering Certification form attached to this permit shall be
submitted with the required supporting documents to the address provided on the form. A complete
certification is one where the form is fully executed and the supporting documents are provided as
applicable.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10. The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H .0500.
11. Noncompliance Notification:
The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville
Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than
24 hours or on the next working day, following the occurrence or first knowledge of the occurrence
of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
2
Voice mail messages or faxed information is permissible, but shall not be considered as the
initial verbal report. Overflows and spills occurring outside normal business hours may also be
reported to the Division of Emergency Management at telephone number (800) 858-0368 or
(919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by
completing Part I of Form CS-SSO (or the most current Division approved form), within five days
following first knowledge of the occurrence. This report shall outline the actions taken or
proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most
current Division approved form) can also be completed to show that the SSO was beyond
control.
Permit issued this the 23rd day of October, 2007.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for Coleen H. Sullins, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0031192 Modification
3
Fast Track Engineering Certification
Permit No. WQ0031192 Modification
October 23, 2007
Owner/VVWIP/WQCS PE
Christie Putnam Jason Sesler
Union County Public Works Stantec Consulting Inc.
400 North Church Street 2127 Ayrsley Town Blvd, Suite 300
Monroe, NC 28112 Charlotte, NC 28273
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• Supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for any changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
El Partial ❑ Final
I, , as a duly registered Professional Engineer in the State of North Carolina, having been
authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Fieldstone Farms Subdivision, a
Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used
in the observation of the construction such that the construction was observed to be built within substantial
compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design
Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
SURFACE WATER PROTECTION
610 EAST CENTER AVENUE, SUITE 301
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
Central Files: APS SWP
10/22/07
Permit Number WQ0031192 Permit Tracking Slip
Program Category Status Project Type
Non -discharge In review Major modification
Permit Type Fast Track Version Permit Classification
Gravity Sewer Extension, Pump Stations, & Pressure Sewer B individual
Extensions
Primary Reviewer Permit Contact Affiliation
dee.browder
Permitted Flow
138510
Fajlity
Facility Name Major/Minor Region
Fieldstone Farms Subdivision Minor Mooresville
Location Address
Owner
County
Union
Facility Contact Affiliation
Owner Name Owner Type
. Union County Public Works Government - County
Owner Affiliation
Christine Putnam, Director Interim
500 N Main St Ste 500
Monroe
DateslEvents
NC 281124730
Scheduled
Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration
01/09/07 10/22/07 10/23/07 10/23/07
Regulated Activities Rectuested/Received Events
Subdivision
Wastewater collection
Outfall NULL
Additional Information received •
Additional information requested
10/18/07
10/18/07
Waterbody Name Stream Index Number Current Class Subbasin
0 Ib. Christie L. Putnam, PE - Director of Public Works
a Brief Project Name (permit will refer to this name) County Where Project is Located
3. Contact Person:
Q3a. Mike Garbark, PE - Assistant Director of Engineering
Name and Affiliation of Someone Who Can Answer Questions About this Application
3b. 704-296-4239 3c. mikegarbark@co.union.nc.us
Phone Number E-mail
CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3
USE THE TAB KEY TO MOVE FROM FIELD TO FIELD!
Owner:
la. Union County Public Works
Full Legal Name (company, municipality, HOA, utility, etc.)
Application Number: �'1�1
(to be completed by DWQ) l�`l�-�b 3 i ! i a"
F, Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!)
lc. The legal entity who will own this system is:
r El Individual ❑ Federal ❑ Municipality ® StatelCounty ❑ Private Partnership 0 Corporation ❑ Other (specify):
re
0 1d. 500 North Main Street, Suite #500 .1e. Monroe
LL ' Mailing Address # City
1f.- NC lg. 28112
Z Slate Zip Code
,1 h. 704-296-4210 11. 704-296-4232 11 j.
I— Telephone Facsimile E-mail
() 2. Project (Facility) - - ___ __.
_ cility) Information:
J 2a. Fieldstone Farms Subdivision 2b. Union County
1. Project is 0 New ® Modification (of an existing permit) If Modification, Permit No.: WQ 0031192
For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another
phase, changing line sizellength, etc.). Only include the modified information in this permit application - do not
duplicate project information in B(7) and B(10-11) that has already been included in the original permit.
2. Owner is ® Public (skip to Item 8(3)) ❑ Private (go to Item 2(a))
2a. If private, applicant will be: , 2b. If sold, facilities owned by a (must choose one)
❑ Retaining Ownership (i.e. store, church, single office, etc.) or E ❑ Public Utility (Instruction iII)
❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Homeowner Assoc./Developer (Instruction IV)
0 0 Selling units (lots, townhomes, etc. - go to Item B(2b))
B3. Union County
0
Li. 5a. Union County
z
Owner of Wastewater Treatment Facility (WWfF) Treating Wastewater From This Project
4a. Twelve Mile Creek WWTP 4b. NC0085359
Name of WWTF WWTF Permit No.
Owner of Downstream Sewer
5b, 18"
Receiving Sewer Size
® Gravity 15c. WQ0019570 - Crooked Creek Interceptor
❑ Force Main Permit Number of Downstream Sewer (if known)
f-- 6. The origin of this wastewater is (check all that apply):
® Residential Subdivision ❑ Car Wash
W❑ Apartments/Condominiums ElInstitution
Q.
El Mobile Home Park 0 Hospital
['School 0 Church
m ❑ Restaurant 0 Nursing Home
❑ Office ❑ Other (specify):
100 % Domestic/Commercial
Industrial
Other (specify):
Volume of wastewater to be allocated for this particular project: 138,510 gallons per day
'Do not include previously permitted allocations
8. If the permitted flow is zero, indicate why:
❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit No. WQ 0031192
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Flows for an additional 254 lots will be permitted at a future date. Sewer for these areas are for construction only.
FTA 02/03 - Rev. 3 04i05
rAPPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4
pri
. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
.0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than
1 that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A
NCAC 2H .0219(1)(3).
t-
(486 lots) (285 gpd) = 138,510 gpd
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
Size (inches)
Length (feet)
Gravity or Force Main
(use the pull down menu)
•••••••r
Q ENTER TOTAL LINE LENGTH IN MILES
" ,11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
0 i Location ID 1 7 Power Reliability Option
(self chosen - as shown on I Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3-
_plans for cross_reference) I (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage)
B. PERMIT
12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force
Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a
variance is requested. SUBMIT Two COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS
PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
113. Have the following permits/certifications been submitted for approval?
Wetland/Stream Crossings - General Permit or 401 Certification? Z Yes ❑ No ❑ N/A
Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A
Stormwater? ® Yes ❑ No El N/A
)4. Does this project involve aerial lines or siphons? Check if yes: ❑
These lines will be considered high priority and must be checked once every six months
Does this project have gravity sewer lines design at minimum slopes? ❑
Be aware that the division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be
corrected prior to submitting the final engineering certification.
FTA 02/03 - Rev. 3 04/05
K APPLICATION for GIA 'ITY SEWES, PUMP STATIONS, AN ID FORCE I IATNS PAGE 5
se the Division's guidance document entitled, "'DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as
ecessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
egional office (see instructions for addresses) CAR indicate the following:
0 * A Stream Classification is not needed because all parts of the project are at Ieat 100 feet away from any down slope
waterbody: AND,
A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability
option for any pump station near a Class C down slope waterbody,
Location ID on Map
self chosen - as shown on Name of Waterbody Stream Waterbody
map for cross-reference) ! Waterbody County River Basin Index. Classification
Submit the 8.5" x 11" COLOR topographic map as required in instruction Vi
Iassification is provided!.
regardless of whether
Applicant`s Certification:
I, Christie L. Putnam, P.E., attest that this application for Fieldstone Farms Subdivision has been reviewed by me and
is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not
completed and that if all required supporting documentation and attachments are not included, this application package
is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and
143- 6.6B, any person who knowingly makes any false statement, representation, or certification in any application
s !l ber' guilty of a Class 2 sderra0a r which may include a fine not to exceed $10,000 as well as civil penalties up to
25,00 J' per violation.
ng Official Siflature
Professional Engineer's Certification:
lO 5 O I
Date
1, Jason Sesler, P.E., attest that this application for Fieldstone Farms Subdivision has been reviewed by me and is
accurate, complete and consistent with the information in the engineering plans, calculations, and al! other supporting
documentation to the best of my knowledge. ! further attest that to the best of my knowledge the proposed design has
been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers
adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain
portions of this submittal package may have been developed by other professionals, inclusion of these materials under my
signature and seal signifies that 1 have reviewed this material and have judged ft to be consistent with the proposed design.
Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false
statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a
fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
!2a. Jason Sesler, P.E.
Professional Engineer Name
2b, Stantec Consulting Inc.
Engineering Firm
2c. 2127 Ayrlsley Town Blvd., Suite 300
Mailing Address
2d. Charlotte
2e. NC 2f. 2827
City State Zip
2g. 980-297-7684 2h, 704-39090
Telephone Fac
2i, Jason.sesler@stantec.com
E-mail
Seat, S'ygna'ture & Date
PTA 02/03 - Rev. 3 04/05
Fieldstone Farms Subdivision
Scale: 1:24000
Bakers, NC Quad Map
Map No. 4854
Re: FieldstWn.e
Subject: Re: Fieldstone
From: Dee Browder <dee.browder@ncln il,net>
Date: Fri, 19 Oct 2007 08:48:39 -0400
To:, MikeiG
Noticed the FM
Is there a pump station associated with this project
And
Of course I would have this same question for any other pent
Thanks
DEE
Mikeaflaakunion. n. us wrote:
Dee,
I am getting ready to respond to all your emails.
Original Permit:
5400 gpd
2761 LF 12" SS
25576 LF - 8" SS
43051F-6"'F'M
Modified Permit (Add)
138510 gpd
0 LF Length
Totals : 143,910 gpd
2761 LF 12" SS
25576 LF - 8" SS
4305 LF - 6" FM
gments
is is the first. Let me know if you don't get what you need.
10 9/2007 8:4 AM
Re: F is dstone
138510 gpd
0 LF Length.
Totals : 143,910 gpd
2761 LF - 1.2" SS
25576 1 F - 8" SS
4305LF-6"FM.
Mike Garbark, P1
Assistant Engineering Director
Union County Public Works
500 N Main Street
Monroe, NC 28112
--Dee Browderdc.e.browder (rrnc:r
To: ntikear°ba
From: Dee Browd
Date: 10/18/2007
Subject: Fieldstone
ua°tion.nc
<dee.browder
:O1AM
"rote: -
i 1. net>
WQ0031.192
Fieldstone Far_ i.s Subdivision
Please list total volumes and line lengths for this project.
Want to make sure that this modification comes out the way
DEE
ADdvw.
10/22/2007 2: t9 PM
Re: Fieldstone
Subject: : Re: Fieldstone
From: MikeGarhark@coamionmcms
Date: Fri, 19 Oct 2007 09:10:44 0400
To: dee:browd r@n rr ail
stet
Yes this can be included with this project. We have it in.
Mike
Mike Garbark, PE
Assistant Engineering Director
Union County Public. Works
500 N Main Street
Monroe, NC 28112
-----Dee Browder <deeAbrowder( ;ncnail.net wrote: -
`i"o: MikeGarbark@co.union:nc.us
From: Dee Browder <dee.browder ct.ncrxrail.net>
Date: 10/19/2007 09:04AM
Subject: Re: Fieldstone
e
ith Fieldstone.
So
1 know that sometime the purrrp station could be with another project
So
Do you want this pump station included with this pen t description?
Thanks
DEE
MikeC
is a 350 gprn station to
Mike
on of the development.
10/22/2007 2:19 PM
Re: Fieldstone
Mike Garbark, PE
Assistant Engineering Director
Union County Public Works
500 N Maier Street
Monroe, NC 228112.
--Dee Browder <dee,bro
To: MikeGarbark(c.o.unio:n.
From: Dee Browder <dee.bro
Date: 10/ 19'1`200.7 08:48AM
Subject: Re: Fieldstone
ote: --
Noticed the FM
Is there a pump station associated with this project.
And
Of course I would have this same question for any other permits with FM segments
Thanks
DEE
Mi_kea barkkr,o.rniun.nc.us wrote:
Dee,
f am getting ready to respond to all your emails. This is the first, f..et me know if you don't get what you
need.
Original Permit:
5400 gpd
2761 LF - 12" SS
25576 LF - 8" SS
4305 LF 6" FM
Modified Permit (Add)
10/22/2007 2:19 PM
Re: Fieldstone
Mike Garbark, PE
Assistant Engineering Director
Union County Public Works
500 N Main Street.
Monroe, NC 28112
--Dee Browder
ebrowdet e . tcra ail.rtet wrote:.,
To: mikegarbark%aco,uniounc.us
From: Dee Browder <dee.rowder`incmail.net>
Date: 1018/2007 11:01 Al
Subject: Fieldstone
WQ0031192
Fieldstone Fartns Subdivision
Please list total volumes and line lengths for this pr a ect,
Want to make sure that this modification comes out the way you wa
DEE
ADdv D
10/ 19/2007 8:49 AM
Re: Fieldstone
Subject: Re: Fieldstone
From: MikeGarbark@co.union.nc.us
Date: Thu, 18 Oct 2007 17:28:28 -0400
To: dee.browder@ncmail.net
Dee,
1 am getting ready to respond to all your emails. This is the first. Let me know if you don't get what you need.
Original Permit:
5400 gpd
2761LF-12"SS
25576LF-8"SS
4305 LF - 6" FM
Modified Permit (Add)
138510 gpd
0 LF Length
Totals : 143,910 gpd
2761 LF - 12" SS
25576LF-8" SS
4305 LF - 6" FM
Mike Garbark, PE
Assistant Engineering Director
Union County Public Works
500 N Main Street
Monroe, NC 28112
----Dee Browder <dee.browder@ncmail.net> wrote:
10/19/2007 8:45 AM
Fieldstone
Subject: Fieldstone
From: Dee Browder <dee.browder@ncmail.net>
Dater Thu, 18 Oct 2007 1 1:01:56 -0400
To: mikegarbark@co.union.nc.us
WQ0031192
Fieldstone Farms Subdivision
Please list total volumes and line lengths for this project.
Want to make sure that this modification comes out the way you want it
DEE
ADdv
10/18/2007 11:02 AM
UNION COUNTY PUBLIC WORKS
500 N. Main Street, Suite 500
Monroe, NC 28112
704/296-4210
Fax 704/296-4232
To: NC Department of Environment and Natural Resources
Mooresville Regional Office
610 East Center Avenue
Suite 301
Mooresville, N.C, 28115
Attention:
Regarding: Sanitary Sewer to serve Fieldstone Farms Subdivision
We are sending you:
TRANSMITTAL
Date: 10/5/07
Copy of letter Ej Plans Q Prints Shop Drawings
Other
Description
Original Non -Discharge Permit Application
Copy of Non -Discharge Permit Application
Check for $480,00 (Appli
These are transmitted as checked below:
For approval 1 For your use
Remarks:
Signed:
Received by:
N MR0
DWQ-Surfac Water Protection
As requested For review and comments
Date: