HomeMy WebLinkAboutWQ0031192_Regional Office Historical File Pre 2018Michael1- rmr G. Ross Jr, Secretarti epartnof Environment and Natu rat Resources' Coleen FY. "Sullins, Director Division of Water Quality October 23, 2007 Ms, Christie Putnam, P.E., Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0031192 Modification Li) Fieldstone Farms Subdivision Wastewater Collection System Per Union County Public Works Union County, North Carolina Dear Ms, Putnam, In accordance with your application received on October 9, 2007, we are forwarding herewith Permit No, WQ0031192, dated October 23, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities„ and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Moores e Regional Office 61.0 East. Center A e , Suite 3t71 MooresvilleInternet: www.ncrnwaterqualibiurg Customer Service: 1-877.623-6741I An Equal Opportunity/Affirmative Action Employer— 50'/Q Recycled/10% Post Consumer Paper Phone- (704) 663-1699 Fax (704) 663.6040 One NorthCarolina ; aturaillf Putnam Page 2 October 23, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 25,576 linear feet of 8-inch gravity sewer, approximately 2,761 linear feet of 12-inch gravity sewer, approximately 4,305 linear feet of 6-inch force main and a 350 gallon per minute pump station with duplex pumps, on - site audible and visual high water alarms, and an on -site generator with automatic transfer switch and the discharge of 138,510 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received October 9, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. _ The sewage and wastewater collected by this system shall be treated in the Union County's Twelve Mile Creek VWVfP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Jason Sessler, Stantec Consulting Inc. Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance -of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shalt be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21_ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 23rd day of October, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031192 Modification 3 Fast Track Engineering Certification Permit No. WQ0031192 Modification October 23, 2007 Owner/VVWIP/WQCS PE Christie Putnam Jason Sesler Union County Public Works Stantec Consulting Inc. 400 North Church Street 2127 Ayrsley Town Blvd, Suite 300 Monroe, NC 28112 Charlotte, NC 28273 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Fieldstone Farms Subdivision, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Central Files: APS SWP 10/22/07 Permit Number WQ0031192 Permit Tracking Slip Program Category Status Project Type Non -discharge In review Major modification Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer B individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 138510 Fajlity Facility Name Major/Minor Region Fieldstone Farms Subdivision Minor Mooresville Location Address Owner County Union Facility Contact Affiliation Owner Name Owner Type . Union County Public Works Government - County Owner Affiliation Christine Putnam, Director Interim 500 N Main St Ste 500 Monroe DateslEvents NC 281124730 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 01/09/07 10/22/07 10/23/07 10/23/07 Regulated Activities Rectuested/Received Events Subdivision Wastewater collection Outfall NULL Additional Information received • Additional information requested 10/18/07 10/18/07 Waterbody Name Stream Index Number Current Class Subbasin 0 Ib. Christie L. Putnam, PE - Director of Public Works a Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: Q3a. Mike Garbark, PE - Assistant Director of Engineering Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-296-4239 3c. mikegarbark@co.union.nc.us Phone Number E-mail CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: la. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) Application Number: �'1�1 (to be completed by DWQ) l�`l�-�b 3 i ! i a" F, Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc. The legal entity who will own this system is: r El Individual ❑ Federal ❑ Municipality ® StatelCounty ❑ Private Partnership 0 Corporation ❑ Other (specify): re 0 1d. 500 North Main Street, Suite #500 .1e. Monroe LL ' Mailing Address # City 1f.- NC lg. 28112 Z Slate Zip Code ,1 h. 704-296-4210 11. 704-296-4232 11 j. I— Telephone Facsimile E-mail () 2. Project (Facility) - - ___ __. _ cility) Information: J 2a. Fieldstone Farms Subdivision 2b. Union County 1. Project is 0 New ® Modification (of an existing permit) If Modification, Permit No.: WQ 0031192 For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line sizellength, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ® Public (skip to Item 8(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: , 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.e. store, church, single office, etc.) or E ❑ Public Utility (Instruction iII) ❑ Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Homeowner Assoc./Developer (Instruction IV) 0 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) B3. Union County 0 Li. 5a. Union County z Owner of Wastewater Treatment Facility (WWfF) Treating Wastewater From This Project 4a. Twelve Mile Creek WWTP 4b. NC0085359 Name of WWTF WWTF Permit No. Owner of Downstream Sewer 5b, 18" Receiving Sewer Size ® Gravity 15c. WQ0019570 - Crooked Creek Interceptor ❑ Force Main Permit Number of Downstream Sewer (if known) f-- 6. The origin of this wastewater is (check all that apply): ® Residential Subdivision ❑ Car Wash W❑ Apartments/Condominiums ElInstitution Q. El Mobile Home Park 0 Hospital ['School 0 Church m ❑ Restaurant 0 Nursing Home ❑ Office ❑ Other (specify): 100 % Domestic/Commercial Industrial Other (specify): Volume of wastewater to be allocated for this particular project: 138,510 gallons per day 'Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. WQ 0031192 ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Flows for an additional 254 lots will be permitted at a future date. Sewer for these areas are for construction only. FTA 02/03 - Rev. 3 04i05 rAPPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 pri . Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than 1 that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3). t- (486 lots) (285 gpd) = 138,510 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) •••••••r Q ENTER TOTAL LINE LENGTH IN MILES " ,11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) 0 i Location ID 1 7 Power Reliability Option (self chosen - as shown on I Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- _plans for cross_reference) I (MGD) GPM @ TDH portable generator wltelemetry; 4-wet well storage) B. PERMIT 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT Two COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 113. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Z Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No El N/A )4. Does this project involve aerial lines or siphons? Check if yes: ❑ These lines will be considered high priority and must be checked once every six months Does this project have gravity sewer lines design at minimum slopes? ❑ Be aware that the division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification. FTA 02/03 - Rev. 3 04/05 K APPLICATION for GIA 'ITY SEWES, PUMP STATIONS, AN ID FORCE I IATNS PAGE 5 se the Division's guidance document entitled, "'DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as ecessary). This document is available from our web site or by contacting the appropriate Division of Water Quality egional office (see instructions for addresses) CAR indicate the following: 0 * A Stream Classification is not needed because all parts of the project are at Ieat 100 feet away from any down slope waterbody: AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody, Location ID on Map self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) ! Waterbody County River Basin Index. Classification Submit the 8.5" x 11" COLOR topographic map as required in instruction Vi Iassification is provided!. regardless of whether Applicant`s Certification: I, Christie L. Putnam, P.E., attest that this application for Fieldstone Farms Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143- 6.6B, any person who knowingly makes any false statement, representation, or certification in any application s !l ber' guilty of a Class 2 sderra0a r which may include a fine not to exceed $10,000 as well as civil penalties up to 25,00 J' per violation. ng Official Siflature Professional Engineer's Certification: lO 5 O I Date 1, Jason Sesler, P.E., attest that this application for Fieldstone Farms Subdivision has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and al! other supporting documentation to the best of my knowledge. ! further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged ft to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. !2a. Jason Sesler, P.E. Professional Engineer Name 2b, Stantec Consulting Inc. Engineering Firm 2c. 2127 Ayrlsley Town Blvd., Suite 300 Mailing Address 2d. Charlotte 2e. NC 2f. 2827 City State Zip 2g. 980-297-7684 2h, 704-39090 Telephone Fac 2i, Jason.sesler@stantec.com E-mail Seat, S'ygna'ture & Date PTA 02/03 - Rev. 3 04/05 Fieldstone Farms Subdivision Scale: 1:24000 Bakers, NC Quad Map Map No. 4854 Re: FieldstWn.e Subject: Re: Fieldstone From: Dee Browder <dee.browder@ncln il,net> Date: Fri, 19 Oct 2007 08:48:39 -0400 To:, MikeiG Noticed the FM Is there a pump station associated with this project And Of course I would have this same question for any other pent Thanks DEE Mikeaflaakunion. n. us wrote: Dee, I am getting ready to respond to all your emails. Original Permit: 5400 gpd 2761 LF 12" SS 25576 LF - 8" SS 43051F-6"'F'M Modified Permit (Add) 138510 gpd 0 LF Length Totals : 143,910 gpd 2761 LF 12" SS 25576 LF - 8" SS 4305 LF - 6" FM gments is is the first. Let me know if you don't get what you need. 10 9/2007 8:4 AM Re: F is dstone 138510 gpd 0 LF Length. Totals : 143,910 gpd 2761 LF - 1.2" SS 25576 1 F - 8" SS 4305LF-6"FM. Mike Garbark, P1 Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 --Dee Browderdc.e.browder (rrnc:r To: ntikear°ba From: Dee Browd Date: 10/18/2007 Subject: Fieldstone ua°tion.nc <dee.browder :O1AM "rote: - i 1. net> WQ0031.192 Fieldstone Far_ i.s Subdivision Please list total volumes and line lengths for this project. Want to make sure that this modification comes out the way DEE ADdvw. 10/22/2007 2: t9 PM Re: Fieldstone Subject: : Re: Fieldstone From: MikeGarhark@coamionmcms Date: Fri, 19 Oct 2007 09:10:44 0400 To: dee:browd r@n rr ail stet Yes this can be included with this project. We have it in. Mike Mike Garbark, PE Assistant Engineering Director Union County Public. Works 500 N Main Street Monroe, NC 28112 -----Dee Browder <deeAbrowder( ;ncnail.net wrote: - `i"o: MikeGarbark@co.union:nc.us From: Dee Browder <dee.browder ct.ncrxrail.net> Date: 10/19/2007 09:04AM Subject: Re: Fieldstone e ith Fieldstone. So 1 know that sometime the purrrp station could be with another project So Do you want this pump station included with this pen t description? Thanks DEE MikeC is a 350 gprn station to Mike on of the development. 10/22/2007 2:19 PM Re: Fieldstone Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Maier Street Monroe, NC 228112. --Dee Browder <dee,bro To: MikeGarbark(c.o.unio:n. From: Dee Browder <dee.bro Date: 10/ 19'1`200.7 08:48AM Subject: Re: Fieldstone ote: -- Noticed the FM Is there a pump station associated with this project. And Of course I would have this same question for any other permits with FM segments Thanks DEE Mi_kea barkkr,o.rniun.nc.us wrote: Dee, f am getting ready to respond to all your emails. This is the first, f..et me know if you don't get what you need. Original Permit: 5400 gpd 2761 LF - 12" SS 25576 LF - 8" SS 4305 LF 6" FM Modified Permit (Add) 10/22/2007 2:19 PM Re: Fieldstone Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street. Monroe, NC 28112 --Dee Browder ebrowdet e . tcra ail.rtet wrote:., To: mikegarbark%aco,uniounc.us From: Dee Browder <dee.rowder`incmail.net> Date: 1018/2007 11:01 Al Subject: Fieldstone WQ0031192 Fieldstone Fartns Subdivision Please list total volumes and line lengths for this pr a ect, Want to make sure that this modification comes out the way you wa DEE ADdv D 10/ 19/2007 8:49 AM Re: Fieldstone Subject: Re: Fieldstone From: MikeGarbark@co.union.nc.us Date: Thu, 18 Oct 2007 17:28:28 -0400 To: dee.browder@ncmail.net Dee, 1 am getting ready to respond to all your emails. This is the first. Let me know if you don't get what you need. Original Permit: 5400 gpd 2761LF-12"SS 25576LF-8"SS 4305 LF - 6" FM Modified Permit (Add) 138510 gpd 0 LF Length Totals : 143,910 gpd 2761 LF - 12" SS 25576LF-8" SS 4305 LF - 6" FM Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 ----Dee Browder <dee.browder@ncmail.net> wrote: 10/19/2007 8:45 AM Fieldstone Subject: Fieldstone From: Dee Browder <dee.browder@ncmail.net> Dater Thu, 18 Oct 2007 1 1:01:56 -0400 To: mikegarbark@co.union.nc.us WQ0031192 Fieldstone Farms Subdivision Please list total volumes and line lengths for this project. Want to make sure that this modification comes out the way you want it DEE ADdv 10/18/2007 11:02 AM UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C, 28115 Attention: Regarding: Sanitary Sewer to serve Fieldstone Farms Subdivision We are sending you: TRANSMITTAL Date: 10/5/07 Copy of letter Ej Plans Q Prints Shop Drawings Other Description Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application Check for $480,00 (Appli These are transmitted as checked below: For approval 1 For your use Remarks: Signed: Received by: N MR0 DWQ-Surfac Water Protection As requested For review and comments Date: