Loading...
HomeMy WebLinkAboutWQ0031172_Regional Office Historical File Pre 2018 (2)Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality October 31, 2008 Mr. Mike Garbark, Assistant Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0031172 Modification The Preserve at Brookhaven Union County Public Works Union County, North Carolina Dear Mr. Garbark, In accordance with your application received on October 23, 2008, we are forwarding herewith Permit No. WQ0031172, dated October 31, 2008, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. No `hCarolina 7atura!!y Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper Mr. Garbark Page 2 October 31, 2008 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 3,234 linear feet of 8-inch gravity sewer as part of the of The Preserve at Brookhaven project and the discharge of 4,635 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received December 14, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's 12 Mile Creek VVVVTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works. Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and their collection system permit WQCS00054. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. if you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, 1-Z4/Z-------- for Colleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Danis Simmons, ESP Associates, PA Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at feast three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 31st day of October, 2008. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0031172 Modification 3 Fast Track Engineering Certification Permit No. WQ0031172 Modification October 31, 2008 WWTPIWQCS PE Mark Garbark Danis Simmons Union County Public Works ESP Associates, PA 400 North Church Street PO Box 7030 Monroe, NC 28112 Charlotte, NC 28241 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of The Preserve at Brookhaven, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM HELD TO FIELD! Application Number: (to be completed by DWQ) OwnerlPermittee: la. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) lb. Mike Garbark , Assistant Director Signing Official Name and Title (Please review 15A NCAC 2T .0 06 (b) for authorized lc. The legal entity who will own this system is: Ej Individual 0 Federal 0 Municipality State/County O ld. 500 North Main Street Suite 500 11. Mailing Address — if. North Carolina ning officials) 0 Private Partnership 0 Corporation 0 Other (specify): Z State O 1h. . 704-296-4239 1i, 704-296-4232 Telephone Facsimile 2. Project (Facility) Information: 2a. The Preserve at Brookhaven Brief Project Name (permit will refer to this name) 3. Contact Person: • 3a, Mike Garbark , Assistant Director 1 e Monroe City lg. 28112 Zip Code 1j. plikegarbark co.union.n .us E-mail 2b. Union County Where Project is ocated Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-296-4239 3c, mikegarbark@counionnc.us Phone Number E-mail 1 Project is 0 New Modification (of an existing perrnit) If Modification, Permit No.: WQ 0031172 2. Owner is I4 Public (skip to Item 8(3)) C3 Private (go to Item 2(a)) 2a. lf private, applicant will be: 2b. If sold, facilities owned by a (must choose one El Retaining Ownership (i.e. store, church, single office, etc.) or El Leasing units (lots, townhomes, etc. - skip to item 8(3)) Selling units (lots, townhomes, etc. - go to Item B(2b)) 0 Public Utility (Instruction C) 0 Homeowner Assoc./Developer (Instruction D) 3. Union Coun Public Works Z Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 0 4a, Twelve Mile Creek WWTP 4b. NC0085359 Name of WWTF WWTF Permit No. 5a. Union County Public Works 5b. 8-inch Z Gravity 5c. WQ0022651 Owner of Downstream Sewer Receiving Sewer Size 0 Force Main Permit # of Downstream Sewer (Instruction E) 6, The origin of this wastewater is (check all that apply): i Z • th Residential Subdivision LJ Apartments/Condominiums El Mobile Horne Park El School O Restaurant Cl Office 0 Retail (Stores, shopping centers) 0 Institution O Hospital Church 0 Nursing Home O Other (specify):_ % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 7 Volume of wastewater to be allocated or permitted for this particular project: -2565 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line • Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA12/07 rProvide the wastewater flow calculations used in determining the permitted flow in accordance wth 15A NCAC 2T .0114 for e value in Item B(7) ANDIOR the design flow for line or pump staton sizing if a reduced or zero flow is being requested in em B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use in accordance with 15A NCAC 2T .0114 (f). -9 LOTS x AVG. 3 BEDROOMS PER LOT @ 95 GALIDAYIBEDROOM = -2565 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main a11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) W 0 Pump Station Location ID (self chosen - as shown on plans/map for reference) Z h- Z 0 Design Flow Operational Point (MGD) GPM @TDH Power Reliability Option 1 - permanent generator MATS; Force Main Size 2 - portable generator wlMTS Force Main Length V Z 0 ~ Pump Station Location ID (self chosen - as shown on plans/map for reference) Q 2 Ce 0 LI Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generator wIMTS Force Main Size Force Main Length . Z H wPump Station Location ID (self chosen - as shown on plans/map for reference) W 0- Ca Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length 12. ■ Will Yes the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ►i No If Yes, permit number of 2nd treatment facility (RO - if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes • No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT 7WO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 e the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No Z N/A Sedimentation and Erosion Control Plan? Z Yes ❑ No ❑ N/A Stormwater? Z Yes ❑ No ❑ N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details CI) Z 0 1" a V 4L. 1— IY LLJ V V 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Mike Garbark , attest that this application for The Preserve at Brookhaven has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil)penafties up to $25,000 per violation. ]�. la. kl\WICkl_1 lU —g Signing Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS PPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Danis Simmons , attest that this application for The Preserve at Brookhaven has been reviewed by me and is accurate, complete and consistent with the information in fhe engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Danis Simmons, P.E. �tn `�111 `,4.0 ARID �4 •+ ��••,i�F�G :Q• � 0., • le . �L . 040."Nc_GQ.• _��41 � y i�Eit •''«..•••,4 ,,, � 1 ��/+3�4�1$sM�,,,U NC PE Seal, Signature &`Date Professional Engineer Name 2b. ESP Associates, P.A. Engineering Firm 2c. Po Box 7030 Mailing Address 2d. Charlotte !2e. NC 2f. 28241 City I State Zip 2g. 803-802-2440 2h. 803-802-2515 �2i. dsimmons(�espassociates.com Telephone Facsimile ! E-mail FTA12/07 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resource Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, NPC, 28115 Attention: TRANSMITTAL DWQ-Surface Regarding: Sanitary Sewer to serve The Preserve at Brookhaven We are sending you: Copies Date 10/17/08 10/21/08 10/17/08 Q Copy of letter Z Other No. Description Plans [ Prints Shop Drawings Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application 190203 Check for $480.00 (Application Fee) Flow Tracking Form Stream Classification Form w/Topo These are transmitted as checked below: For approval Lf For your use I l As requested LI Remarks: Signed: ap For review and comments Received by: Date: State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Traeking/Acceptance for Sewer Extension Permit Applications (.FTSE —10107) Project Applicant Name: ounty Project Name for which flow is being requested: The Preset More than one f` 7;SiE-10/07 rntr�= h r c:. yrrlr° pump stations along the route of the propo, Brookhaven single project if the owner 7WT'7' is not responsible far tc water flow I. Complete this section only if you are the owner ofthe wa tewater treatment plant. a. WWTP Fa.cility Name: b. WWTP Facility Permit Twelve Mile Cre NC0085359 c. WWTP facility's permitted flow d. Estimated obligated flow not vet tributary to the WWTP e. W'VTP facility's actual avg, flow f. Total flow for this specific request. g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in Pv1GD 6=0000 1.4600 2.740833 -0.0026 4.20 69.97 IL Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point, and the WWTP Pump Station Name Brookhaven Approx. Capacity,, MCrf) Approx. Current Avg. (Firm/Design) Daily Flow; MGD m & Creed Engineers 1,726.560 MGf) .343 MGD III. Certification Statement: I, Mike Ciarhark certit) that, to the best c fmy knowledge, the addition c f'the volume of wastewater- to be permitted in this project: has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity' related sanitary sewer overflows or overburd.en any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1 and 11 for which I am the responsible party. Signature of this form indicates acceptance of this wstewater Signing t. i Date} RM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name Union County Public Works The Preserve At Brookhaven Professional Engineer Name Engineering Firm Name Danis E. Simmons, P.E. ESP Associates, P.A. Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification 1 W. Fork Trib. 12 Mile Creek Union Catawba 11-138-1 C If unnamed, indicate "unnamed tributary to X", where Xis the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that 1 have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page 1 of 1 Matthews, 7.5 Minute Topographic USGS Map Permit Number WQ0031172 Program Category Non -discharge Central Files: APS_ SWP^ 10/31/08 Permit Tracking Slip Status Active Project Type Major modification Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.20 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Row 4635 Facility Facility Name Major/Minor Region The Preserve at Brookhaven Minor Mooresville Location Address Owner County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Dates/Events Orig Issue 01/03/07 Owner Affiliation Matthew Delk, Director Interim Public Works of App Received Draft Initiated 10/31/08 Scheduled Issuance Public Notice Issue 10/31/08 Effective Expiration 10/31/08 Regulated Activities Reauested/Received Events Subdivision Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin Re: Preserve at Brookhave - WQ0031172 Mod EDIT Subject: Re: Preserve at Brookhave - WQ0031172 Mod EDIT From: MikeGarbark@co.union.nc.us Date: Fri, 14 Nov 2008 12:44:48 -0500 To: MikeGarbark@co.union.nc.us CC: dee.browder@ncmail.net, LarryDavis@co.union.nc.us, PBrown@co.union.nc.us Dee, Have you had a chance to look at this yet? Thanks, Mike Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 Mike Garbark/UnionCounty wrote: To: dee.browder@ncmail.net From: Mike Garbark/UnionCounty Date: 11/03/2008 04:21PM cc: Larry Davis/UnionCounty@UnionCounty, Peter Brown/UnionCounty@UnionCounty Subject: Preserve at Brookhave - WQ0031172 Mod EDIT Dee, Hey it it me again. Actually just wanted to let you know that we received a permit back with an a math error in the discharge. Permit No. WQ0031172 Mod was sent into you about a week ago to subtract (-2565gpd) of flow from the current permit. DWQ approved the permit on 10/31/08 and I just got it in the mail today. Problem is that flow was subtracted from. the original 1 of 2 11/14/2008 2:56 PM Re: Preserve at Brookhave - WQ003I 172 Mod EDTT WQ0031172 discharge from the January 5, 2007 permit of 7200 gpd. This permit was actually modified the 1st time on 11/20/2007 which brought the discharge total to 10,905 gpd. The subtraction of 2565 gpd should have been removed from the 10,905 gpd. This would make the newest permit read 8340gpd instead of the 4635 gpd it now shows. Could you change this and resend? Or if you agree you can send an email letting me know it is okay and I will change our copy. Thanks, Mike Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 2 of 2 11/14/2008 2:56 PM Fast Track Engineering Certification Permit#:WQ0031172 Modification October 31, 2008 WWTP/WQCS PE Mark Garbark Danis Simmons Union County Public Works ESP Associates, PA 400 North Church Street PO Box 7030 Monroe, NC 28112 Charlotte, NC 28241 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final I, Danis Simmons , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (X periodically, [1] weekly, [11 full time) the construction of the Brookhaven Subdivision Phase 4, Union County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS Ili Pelleata. CAR -I' MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 East Center Avenue, Suite 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partia p until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment & Natural Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Attention: Dee Browder Regarding: Engineer's Certification for Brookhaven Phase 4 We are sending you: [] Copy of letter Plans 0 Prints E Shop Drawings Other TRANSMITTAL Date No. Description Record Drawings Date: 7/30/09 Engineer's Certification for Sewer (Permit WO0031172 Mod These are transmitted as checked belo L.3 For approval For your use D As requested For review and comments Remarks: Signed: / Received by: Date: