Loading...
HomeMy WebLinkAboutWQ0030526_Regional Office Historical File Pre 2018• ILE Beverly Eaves Perdue Governor AIrA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Charles Wakild, P. E. Director Union County Public Works Mr. Mike Garbark, P.E., Assistant Director 500 N. Main Street, Suite 500 Monroe, North Carolina 28112 Dear Mr. Garbark: January 24, 2012 of Public Works Dee Freeman Secretary Subject: Permit No. WQ0030526 (Modification) Bonterra III A Wastewater Collection System Extension Union County, North Carolina In accordance with your application received on January 20, 2012, we are forwarding herewith Permit No.WQ0030526, dated January 24, 2012, Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 30I Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-- 50% Recycled/10% Post Consumer Paper No °Carolina ,Naturally Mr, Garbark Page 2 January 24, 2012 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 1,579 linear feet of 8-inch gravity sewer and the discharge of 6,555 gallons per day of collected domestic wastewater (previous permit was issued on July 17, 2006 for approximately 2,713 linear feet and the discharge of 16,560 gallons per day) into Twelve Mile Creek existing sewerage system, pursuant to the application received on January 20, 2012, and in conformity with 1.5A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February -12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit.. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County Public Works. Union County Public Works must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the WQCS00054 permit requirements. The sewage and wastewater collected by this system shall be treated in Twelve Mile Creek Wastewater Treatment plant WWTP (NPDES No.NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and .filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Samar Bou-Ghazale at (704) 663-1699. Sincerely, or Charles Wakild, P.E. cc: Mooresville Regional Office, Collection,. System Permit .File Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT (MODIFICATION) This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. t 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Perrnttee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T, the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215,6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. I Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 24th day of January, 2012. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 15) 6 for Charles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030526 (Modification) 3 Fast Track Engineering Certification Permit No. WQ0030526 (Modification) January 24, 2012 OwnerM/WTP/WQCS Union County Public Works Bonterra III A 500 N. Main St Suite 500 Monroe, NC 28112 John H, Ross, PE Eagle Engineering, Inc. 2013 Van Buren Ave. Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION Ej Partial El Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, El weekly, LI full time) the construction of Bonterra III A, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, E TAB KEY TO MOVE FROM FIELD TO FIELDApplication Number: (to be completed by DWQ) n riPermittee: Unibn County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) lb. Mike Garbark, P,E, Assistant Director of Public works Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) 1 c The legal entity who will own this system is: Individual E] Federal E Municipality State/County Ej Private Partnership E Corporation El Other (specify), ld, 500 N. Main Street, Suite 500 Mailing Address if, North Carolina Z State ih (704) 296-4239 1— Telephone le Monroe City g 28112 Zip Code ECL"'' L-LL 4:Ltir4--04:11 i, (704) 296-.4232 lj. mikegarbark@munion.m sEcTioNL , Facsimile E-mail MOORESVILLE REGIONAL OFFICtE 2. Project "Facility) Information: 2a, Bonterra Ill A 2b. Union o this name) County Where Project is Located Brief Project Name (pe 3. Contact Person: 3a. Mike Garbark, P.E. Assistant Director of Public Works Name and Affiliation of Someone Who Can Answer Questions About this Application 30. C7041296-4239 3c. miktgarbark@couniorLncus er Phone Number E-mail 1. Project is El New Modification (of an existing permit) If Modification, Permit No,: WQ0030526 2, Owner is El Public (skip to Item 8(3)) E] Private (go to Item 2(a)) 2a. It private, applicant will be. 2b. If sold, facilities owned by a (must choose ring E] Retaining Ownership (i.e. store, church, single office, etc.) or El Leasing units (lots, townhomes, etc - skip to item B(3)) jp. Selling units (lots, townhomes, etc. - go to /tern B(2b)) 3. Union County Public Works Owner of Wastewater Treatment Facility (WVVTF) Treating Wastewater From This Project Q 4a, Twelve Mile 4b. NC0085359 1= Name of VVVVTF WVVTF Permit No 5a, Union Count Public Works _15b, 15" ! Gravity 15c. WQ0021447 PERMIT INFO 111 Public Utility (Instruction C) LJ Homeowner Assoc /Developer (Instruction D) Owner of Downstream Sewer Receiving Sewer Size ;0 Force Main Permit # of Downstream Sewer (Instruction 6. The origin of this wastewater is (check all that apply): Z Residential Subdivision El Apartments/Condominiums Ej Mobile Home Park Ei School Ej Restaurant LI Office El Retail (Stores, shopping centers) El Institution 1:i Hospital LI Church Nursing Home [1] Other (specify): 100 DomesticJCommercial % industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) E) % Other (specify): 7, Volume of wastewater to be allocated or permitted for this particular project; -10,005 gpd for a new total of 6,555 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: E] Pump Station, Outfail or Interceptor Line where flow will be permitted in subsequent permits that connect to this line E Flow has already been allocated in Permit No E] Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FIA1.2/07 B. PERMIT INFORMATION (CONTINUED) in determining the permitted flow for line or pump station sizing if a 2T .0114 (b) and (c) must be supported (f). gpd/lot for remaining 23 lots)= -10,005 + (-1,725 gpd) = 6,555 gpd e the wastewater flow calculations used value in Item B(7) AND/OR the design flow Item B(7). Values other than that in 15A NCAC data in accordance with 15A NCAC 2T .0114 (16,560 gpd) + (-23 lots @ 120 gpd X 3BR) + (-75 (16,560 gpd previously permitted) + (-8,250 gpd) (16,560 gpd) — (10,005 gpd) = 6,555 gpd in accordance with 15A NCAC 2T .0114 for reduced or zero flow is being requested in with actual water or wastewater use gpd for a new total of 6,555 gpd; 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Length (feet) r New Gravity . Size (inches) or Additional Force Main 8" -1134 I.f. for a new total of 1,579 I.f. Gravity . 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as (self chosen - as shown on planslmap necessary) Pump Station Location ID for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generator wJMTS Force Main Size Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator MATS; 2 - portable generator wIMTS Force Main Size Force Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w1ATS; 2 - portable generatorw!MTS Force Main Size ' j I Force Main Length 12. Will the wastewater flow in the proposed sewer number of 2nd treatment contact the Central lines or pump stations be able to be directed to another facility treatment facility? • Yes ® No If Yes, permit (RO — if "yes" to B,12 please Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ►� Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 following permits/certifications been submitted for approval for the system or project to be served? 0 1— tland/Stream Crossings - General Permit or 401Certification? . ' • Sedimentation and Erosion Control Plan? Stormwater? El Yes El No Yes LINo LEI Yes E] No .E.e] N/A N/A E] N/A 15. Does this project include any high priority lines, (see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: 0 and provide details 1 a Owner/Permittee's Certification: (Signature of Signing Official and Project Name) I, Mike Garbark, attest that this application for Bonterra PH 3A has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, igning Official Signature ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMI I I AL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC, REFER TO 15A NCAC 02T .0305 2. Professional Engineers Certification: (Signature of Design Engineer and Project Name) 1, John H. Ross, attest that this application for Bonterra, PH, 3A has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-2156B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. John H. Ross Professional Engineer Name 2b, Ea le Engineering, Inc, Engineering Firm 2c, 2013 Van Buren Ave, Mailing Address 2d, lndian Trail City 2g, (704) 882- 0561 2h, 066) 775-0329 Telephone Facsimile 2e, NC 2f 28079 State Zip 2i. jross@eagleonline.ne E-mail ous NC PE Seal, Signature & Date FTA 12/07 UNITED STATES DEPARTMENT OF THE INTERIOR `�- GEOLOGICAL SURVEY 80 ° „a 35 07' 30'° 536 FOR 1 WSCAS-12/07 WATERSHED CLASSCA`l`ION ATTACHMENT FOR SEWER SYSTEMS plicant Name Union County Public Works Professional Engin John H. Ross, P.E, r Name t Name onterra III A Engineering Firm Name Eagle Engineering, Inc. location River Waterbody ID Name of Waterbody1 wCounty_ : Basin Stream Index N SITE U T. TO NORTH FORK UNION ' YADKIN 1:-17.20-1 OROOKETI CREEK If unnamed, indicate "unnamed tributary to X", where Xis the named waterbody to which the unnamed tributary j 1 certify that as a Registered Professional Engineer in the State of North Carolina that 1 have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSC"AS-12f07 **'* Waterbody Classification FORM: WSCAS-12/07 Page 1 of 1 Department of Envrironi State of North Carolina and Natural Resources ivision of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE ----10/07;) Project Applicant Name: Union County Project Name for which tick is being requested: Afore than one FTS.0 1O/O7 rnav he required trr tr srtz project if th armp stations along the route of the proposed wastewater flow. 'her of the iV`)JTP is not responsible/or all I. Complete this section only a. WWTP Facility Name: b. WWTP Facility Permit : are the owner of the was Twelve Mile Cre NC0085359 a er treltme plant. c.. WWT`P facility's pertnitted flown d. Estimated obligated flow not yet tributar; e. WWTP facility's actual. avg,, flow f Total flow for this specific request g. Total actual and obligated flows to the fa h. Percent of pertnitted flow used io the WWTP All flows are in 1v1G I) 6.0000 1,587 3.56 -0.01 5.1370 85,62 11. Complete this section for each pump station y°ou are responsible for along the route of this proposed wastewater flow. Fist pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGI) (Firm/Design) Poplin Poad 3.1.6/Mcl inn & Creed A.pprox.. Current Avg. Daily Flow, MGI) 0.69 arbarl y certify that te> the best of tray" knowledge, the addition of the volume of wastewater to be permitted in this l:aroject lets been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related. sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, This analysis has been perfornned in accordance with local established policies and procedures using the best: available data. This certification applies to those items listed above in Sections 1 and 11 for which l am the responsible party. Signature of this form indicates acceptance of thi Sigac tray Signature Date UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Mooresville, N.C, 28115 Attention: Regarding: Sanitary Sewer to serve Bonterra, Phase 3A We are sending you: [1 Copy of letter El Hans Q Prints D Shop Drawings E Other TRANSMITTAL DMS 1/17/12 1/17/12 No, 521 Description Non -Discharge Permit Application Copy of Non -Discharge Permit Application Flow Tracking Form $48OE00 Check (Application Fee) Stream Cla.ssifcation Form These are transmitted as checked below: Date: '1118/12 For approval P For your use P As requested n For review and comments Remarks: Signed: Received by: Date: Permit Number WQ0030526 Central Files: APS SWP 01/24/12 Permit Tracking Slip Program Category Status Non -discharge Active Project Type Major modification Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.10 Individual Extensions Primary Reviewer Permit Contact Affiliation samar.bou-ghazale Coastal SW Rule Permitted Flow 6555 Facility Facility Name Major/Minor Region Bonterra Phase 11IA Minor Mooresville Location Address County Union Facility Contact Affiliation Owner Owner Name Owner Type Union County Public Works Government - County Dates/Events Owner Affiliation Mark Eugene Tye 500 N Church St Ste 500 Monroe NC 281124730 Orlg Issue App Received 07/12/06 01/20/12 Draft Initiated Scheduled Issuance Public Notice Issue Effective Expiration 01/24/12 01/24/12 Regulated Activities Requested/Received Events Subdivision Wastewater collection Outfall NULL Additional Information received Additional information requested Waterbody Name Stream Index Number Current Class Subbasin