Loading...
HomeMy WebLinkAboutWQ0030201_Regional Office Historical File Pre 2018 (2)Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality November 15, 2007 Ms. Christie Putnam, P.E., Director of Public Works Union County Public Works - 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0030201 Modification Garmon's Crossing Wastewater Collection System Permit Union County Public Works Union County, North Carolina Dear Ms. Putnam, In accordance with your application received on November 1, 2007 we are forwarding herewith Permit No. WQ0030201, dated November 15, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave„ Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquaiity.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycledll0% Post Consumer Paper None r hCarolina ,Naturally Pnarn Page 2 November 15, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Union County Public Works for the construction and operation of approximately 3,170 linear feet of 8-inch gravity sewer and the discharge of 18,600 gallons per day of collected domestic wastewater into the Union County existing sewerage system, pursuant to the application received November 1, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County's Twelve Mile Creek WWTP (NPDES No. NC0085359) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, f ill for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Jon Patrick, Eagle Engineering Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. if an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 1 4. This permit shalt not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations dontained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations,'or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 26 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 15th day of November, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION q 4 6 1(____. for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030201 Modification 3 Fast Track Engineering Certification Permit No. WQ0030201 Modification November 15, 2007 OwnerNWVTP/WQCS PE Christie Putnam Jon Patrick Union County Public Works Eagle Engineering 400 North Church Street 2013 Van Buren Ave. Monroe, NC 28112 Indian Trail, NC 28079 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Garmon's Crossing, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. PAGE 3 0 1b. Christie L. Putnam, P.E. Director of Union County Public Works Signing Official Name and Title (Please review 15A NCAC 2H ,0206(b) for authorized signing o The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality X State/County EJ Private Partnership 0 Corporation 0 Other (specify): Street, Ste. 500 le. Monroe 1 d. 500 North Main _.., K AP CATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Numt r: (to be compEeted by DWQ) 0 LL Z 0 1. Owner la. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc.) Mailing Address City North Carolina State 1 h. (704. 296-4210 1 i. (704) 296-4232 Telephone 2. Project (Facility) Information. 2a. Deerstyne (t.K.A.. Garman's Crossing d Brief Project Name (permit will refer to this name Id. [ Contact Person: Via. mMike Garbark, P.E., Assistant Director Union Coin Public Works,,, Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (704) 296-4239 3c. mikegarbark co.union nc.us Facsimile Phone Number E-mail lg. 28112-4730 Zip Code utnam co.unio E-mail 2b, Union County Where Project is Located . Project is New Modification (of an existing permit) If Modification, Permit No.; WQ0030201 For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and BB(10-11) that has already been included in the original permit. 2. Owner is X Public (skip to kiItem B(3)) 0 Private (go to Item 2(a)) 2a. if private, applicant will be: 2b. If sold, facilities owned by a (must choose one 0 Retaining Ownership (i,e, store, church„ single office, etc.) or 0' Leasing units (lots, townhomes, etc, - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 0 Public Utility (Instruction 11I) 0 Homeowner Assoc,/Developer (Instruction IV) Union County Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project Twelve Mile Creek Q . _. W /VTF Name af_..�._�..,_.___...._.___ _....� LL 5a. Union County bb _ Z Owner of Downstream Sewer�eceiving Sewer S M % ize Force Main f Permit Number of Downstream Sewer (if known 0 _ .v E— mThe origin of this wastewater is (check all that apply): X Residential Subdivision Ej Apartments/Condominiums 0 Mobile Home Parts 0 School O Restaurant Office 4b. NC0085359 WWTF Permit No. Gravity Vic. WQ0019071 O Car Wash O institution © Hospital 0 Church El Nursing Home 0 Other (specify): 100 % Domestic/Commercial °I© Industrial % Other (specify): 7, Volume of wastewater to be allocated for this particular project: 11,400 gallons per day Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: 0 interceptor Line - Flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected F"FA 0..103 - Rev. 3 04,'"05 z K AP:PLICATION for GKAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PA4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(l)(3). 40 lots x 95 gpd x 3 bedrooms = 11,400 gpd original Permit = 7,200 gpd 10. Summary of Sewer Lines trs be Permitted (attach additional sheets if necessary) Size (inches) (No Additional lines) ENTER TOTAL LINE LENGTH IN MILES Length (feet) Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on Design Flow Operational Point plans for cross-reference) (MGD) GPM @ TDH Gravity or Force Main use the pull down menu) Power Reliability Option (1- dual line feed; 2- permanent generator w1ATS; 3- portable generator wlte'lemetry;; 4-wet well storage) Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force!, Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable?:', X Yes El No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following permitslcertifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No X NIA Sedimentation and Erosion Control Plan? Stormwater? 14, Does this project involve aerial lines or siphons? Check if yes: 0 These lines will be considered high orionty and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? X Be aware that the Division will not accept installed lines more than 10% flatter than the minimum corrected prior to submitting the final engineering certification.. Yes X No 0 NIA Yes X No 0 N/A d outsid erance should be FTA 02/03 Rev, a 04t05 z 0 ACK APPLICATION for GRAVITY SEWERS, PIU P STATIONS, AND FORCE MAINS PAGE Use the Division's guidance document entitled, "''DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS) to collect and record the stream classification data below (attach additional sheets eI necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, El A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody_ Location ID on Map (self chosen - as shown on map for cross-reference) From Source to Crooked Crppk 1a. Name of Waterbody S Fork r rnnkpri C rppk County Union River Basin Yadkin Waterbody Stream Waterbody Index Classification 17-20-2 C Submit the 8.5" x 11" COLOR topographic map as required in Instruction V1 regardless of whether a classification is provided! Applicant's Certification: 1, Christie L. Putnam, attest that this application for Deerstyne (F.K.A.: Garmon's Crossing) has been reviewed by me and is accurate and complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143- 215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil pe,rfalties' up to $25,000 0 per viblation, Signing Official Signature Professional Engineer's Certification: Date I attest that this application for Deerstyne (F.K.A.: Garmon's Crossing) has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations„ and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement,. representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jon R. Patrick, P.E. Professional Engineer Name 2b. Eagle Engineering Engineering Firm 2c. 2013 Van Buren Ave, Mailing Address 2d. Indian Trail City:.... 2g. (704) 882-4222 2h. 7 482-4232 Telephone Facsimile 2e. NC 2f. 28079 State Zip 2i, jpatrick@eagleonlne_net E-mail Seal, Signature & Date FTA 02/03 - Rev, 3 04/05 80° 42' 0.00" W 080' 41' 0.00" W 080' 41' 0.00" W Copyright (C) 1997 Maptech, Irvc. 080° 40' 0.00" W 080° 39' 0.00" 1 080° 40' 0.00" W z 080° 39' 0.00° 1 UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 TRANSMITTAL Attention: Regarding: Sanitary Sewer to serve Deerstyne (Garmon's Crossing) subdivision We are sending you: Copies Date: 16 30/07 Copy of letter R' Plans Prints Shop Drawings Other No, Description Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application Check for $480 0O (Application F These are transed as checked below: DWQ-Surface rot clion IZ For approval 0 For your use 0 As requested 0 For review and comments Re ks: Signed: Received by: Date: Permit Number WQ0030201 Central Files: APS SWP 11 /15/07 Permit Tracking Slip Program Category Status Non -discharge In review Permit Type Fast Track Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer 8 Extensions Primary Reviewer dee.browder Permitted Flow 7200 Facility Project Type Major modification Permit Classification Individual Permit Contact Affiliation Facility Name MajorlMinor Region Garmon's Crossing Minor Central Location Address Owner County Unknown Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Dates/Events Orig Issue App Received Draft Initiated 05/06/06 11/15/07 Scheduled Issuance Owner Affiliation Christine Putnam, Director Interim 500 N Main St Ste 500 Monroe Public Notice Issue NC 281124730 Effective Expiration Regulated Activities Rearrested/Received Events Subdivision Wastewater collection Outfall NULL Additional information requested Additional information received Waterbody Name Stream Index Number Current Class Subbasin