HomeMy WebLinkAboutWQ0029254_Regional Office Historical File Pre 2018p v" 5‘S/.5;k49 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality November 13, 2007 Ms. Christie Putnam, P.E., Director of Public Works Union County Public Works 500 North Main Street Monroe, NC 28112 Subject: Permit No. WQ0029254 Modification Sheridan Subdivision -Phase 1 Wastewater Collection System Permit Union County Public Works Union County, North Carolina Dear Ms. Putnam, In accordance with your application received on November 9, 2007, we are forwarding herewith Permit No. WQ0029254, dated November 13, 2007, to the Union County Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycled/10% Post Consumer Paper One Caroli Nna ,Naturally z 0 H 2 0 l.L z z J l 0. APPLICATION for GRAVITY SE `C+RS, PUMP STATIONS, AND FORCE t4`MAINS USE THE TAB KEY TO MOVE FROM FIEL TO FIELD! 1, Owner: 1 a. Union County Public Works Full Legal Name (company, municipality, HOA, utility, etc,) 1b, Christie L. Putnam, P.E. Director of Public Works Application Number: (to be completed by i7WQ) PAGE 3 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) c. The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality State/County 0 Private Partnership 0 Corporation (l Other (specify): Id. 500 N. Main Street, Suite 500 Mailing Address City 1f. NC 1g. 26112 1 e. Monroe State 1 h. (704) 296-421 d Telephone 2. Project (Facili(y) Information. 2a. Sheridan Subdivision - Phase 1 Brief Project Name (permit will refer to this name 3. Contact Person: 3a. Mike Garbark, P.E. A Name and Affiliation o 3b. (704) 296-4239 Phone Number nt erector of Public o Can Answer Qu Zip Code E-mail 1. Project Is L New Mo dification (of an exiisling permit) if Modification, Permit No.: W00029254 here Project is Located For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information In this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is Public (skip to Item 8(3)) 0 Private (go to Item 2(e)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must chi os 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Public Utility (instruction ill) 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Homeowner Assoc./Developer (Instruction IV) 0 0 Selling units (lots, townhomes, etc. - go to Item 8(2b)) Union County Public Works Owner of Wastewater Treatment Faci Twelve Mile Creek. WWTP Name of WWTF Treating Wastewater From This Project Union County Public Works Tb 8" Owner of Downstream Sewer Receiving Sewer Size The origin of this wastewater is (check all that apply): Residential Subdivision © Apartments/Condominiums 0 Mobile Home Park 0 School 0 Restaurant 0 Office Volume of wastewater to be alloca *Do not include previously perms 4b. NG0085359 WWTF Permit No. ►i Gravity c. WQ0023711 0 Force Main Permit Number of Downstream Sewer (if known) © Car Wash 0 Institution 0 Hospital © Church Nursing Home Other (specify): 100 % Domestic/Commercial % industrial % Other (specify): for this particular project: 22,515 . gallons per day-" _...__. d allocations If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted in subsequent pe 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected that connect to this line FTA 02/03 - Rev. 3 04/05 PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 - Pr p Z 1 Z O V11. 0 Qplans 2re 0 1J.. Z H E12. CC W a CO 9. Provide the wastewater Flow .0219(1) for Item B(7) or the that in 15A NCAC 2H .0219(I)(1-2) NCAC 2H .0219(1)(3). 79 single — family units: 285 approved Dec. 1, 2005) 10. Summary of Sewer Lines __ _ __—___. —_ -- -._ - Size (inches) L (No Additional Line)_ calculations design flow for must GPD/unit x Previous to be Permitted - . ._ • - -------- used be 79 (attach in determining the permitted flow in accordance with 15A NCAC 2H line or pump station sizing if zero flow in the space below. Values other than supported with actual water or wastewater use data in accordance with 15A Lots = 22,515 GPD (Note: 159 total lots Permit = 28,800 gpd additional sheets if necessary) T - Length (feet) in Phase 1, 80 lots previously Gravity or Force Main (use the pull down menu) r__ ---- --- ---_- ----- - - _--- --- - - - ENTER TOTAL LINE LENGTH IN MILES Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on for cross-reference) NIA Design Flow (MGD) I Power Reliability Option Operational Point (1- dual line feed; 2- permanent generator wtATS; 3- GPM @ TDH portable generator w/telemetry; 4-wet well storag!) . Does the sewer system comply Mains (latest version), the with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? reference the pertinent minimum design criteria or regulation and indicate why a is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS TO THE VARIANCE WITH YOUR APPLICATION • CI Yes ■ No If no, please variance PERTINENT 14. these 15. i 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? ❑ N/A 1/ Yes • No CI Yes ■ No ■ NIA ■ NIA Installed outside this tolerance should be I Yes ■ No 0 — —_ __ _ slopes? the minimum slope. Lines Does this project involve aerial lines or siphons? Check if yes: Lines will be_considered.hiab crioritvandmust_be. checked_once everv_sixmonths_ Does this project have gravity sewer lines designed at minimum Be aware that the Division will not accept Installed lines more than 10% flatter than corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04/05 VI1CATON for GRAV'I"t"t'' SEWERS. PUMP STATIONS, ANit FORCE MALNS PAGE S visions gudnce document entitled, "°DETERMNING STREAM CLASSIFICATIONS FOR FORM FTA ©2/03 ACK SEWER SYSTEMS)" to collect and record the stream classificaton data below (attach additional sheets as). Ths document is available from our web ste or by contacting the appropriate Division of Water Quality ffice (see instructions for addresses) OR indicate the following: ,..,. 0 A Stream Classification is not needed because sil parts of the project are at least 100 feet away from any down slope waterbody; AND, z A Stream Classification is not needed because the design does not depend on wet option for any pump station near a Class C down slope waterbody, orage as a power reliability Location. ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification SITE Price Mill Creek Trib. Union Catawba 11-138-2-2 C Submit the 8.5"* x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification. I, Christie t., Putnam P.E. Director of Public 1+1I°orks, attest that this application for Sheridan Subdivision Phase 1 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included this application package is subject to being returned as incomplete, Note: In accordance with North Carolina Gen Statutes 143-215, 6A and 143-215, 6B, any person who knowingly makes any false statement, representation, or itln in any application gall be gality of a Class 2 misdemeanor which may include a fine not to exceed $10 000 i vil penalties u $25,000 violation, igning Official Signature Professional Engineer's Certification. /S 0) Date 1 attest that this application for Sheridan Subdivision Phase 1 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215, 68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,O00 per violation, 2a. Wane M. Harris, P,E Professional Engineer Name 2b. Hams Engineering _ Engineering Firrn 2c. 1325 Harding Place Mailing Address 2d. Charlotte City 29.:(704) 334-1325 2h. (704) 334-1330 Telephone Facsimile 2e. NC 2f. 28204 State zip 2i. wharris@harris-engr.com E-mail Seal, Signature & Date FTA 02/03 - Rev. 3 04/O5 Central Files: APS SWP 11/09/07 lirirPermit Number WQ0029254 Permit Tracking Slip Program Category Status Non -discharge Active Project Type Major modification Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.20 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 51315 Facility Facility Name Sheridan Subdivision -Phase 1 Location Address Owne Major/Minor Region Minor Mooresville County Union Facility Contact Affiliation Owner Name Owner Type Union County Public Works Government - County Dates/vents orig Issue App Received Draft Initiated 08/31/05 11/09/07 Regulated Activities Subdivision Wastewater collection Outfall NULL Scheduled Issuance Owner Affiliation Christine Putnam, Director Interim 500 N Main St Ste 500 Monroe NC 281124730 Public Notice Issue 11/13/07 Effective Expiration 11/13/07 $gauested/Received Events Additional information requested Additional information received 10/29/07 11/09/07 Waterbody Name Stream.Index Number Current Class Subbasln Re: Sheridan Subdivision Phase I Subjeet: Re: Sheridan Su vision Phase From: Dee Browder de „ ra wd Date Fri, 0 Nov 200711:31:23 -T Wi11 need to Thanks DEE nfi al Mi e a.rhar, co.union.n wus wrote. Only the flow changes on this. Total Flow should be 51,315 grid Mike Garbark, PE Assistant. Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28112 Dee Browder <dee.1 ine wdert' ne et> Ind sizes ail.net> wrote: To: M keGarbark(co.union.nc.us From: Dee Browder <dee.browder*n Date: 10/29/2007 03:55PM Subject. Sheridan Subdivision. Phase 1. 1 o1'' 2 1 1 /9I 3iI7 1 1:31 AM Sheridan Subdivision Phase I Subject: Sheridan Subdivision Phase 1 From: Dee Browder <dee.browder@ncmail.net> Date: Mon, 29 Oct 2007 15:55:10 -0400 To: MikeGarbark@co.union.nc.us Wq0029254 Need totals Thanks DEE ' ADdv 1 of I 10/29/2007 3:55 PM UNION COUNTY PUBLIC WORKS 500 N. Main Street, Suite 500 Monroe, NC 28112 704/296-4210 Fax 704/296-4232 To: NC Department of Environment and Natural Resources Mooresville Regional Office 610 East Center Avenue Suite 301 Mooresville, N.C. 28115 TRANSMITTAL Attention: Date: 10/19/07 Regarding: Sanitary Sewer to serve Sheridan, Phase 1 Subdivision We are sending you: '[] Copy of letter Ej Plans 0 Prints Shop Drawings 1 Other Copies i Date 10/7/07 10/7/07 10/15/07 No, j Description Original Non -Discharge Permit Application Copy of Non -Discharge Permit Application 006596 ; Check for $480.00 (Application Fee) These are transmitted as checked below: For approval For your use As requested Remarks: Signed: For reviewNC and c©r en DWQ Surface Water Pro on Received by: Date: Re: Sheridan Subdivision Phase 1 Subject: Re: Sheridan Subdivision Phase I From: MikeGarbark co.union.r c.us Date: Fri, 9 Nov 20 711:5 11:50:09 -0 Length change from Modification = 0 f Total Length - 8447 LF of 8" Gravity. Mike Garbark, PE Assistant Engineering Director Union County Public Works 500 N Main Street Monroe, NC 28 112 --Dee < Browder dee.browder@ncrnail.net- wrote: — To: MikeGarbark@coxunion.nc.us From: Dee Browder <dee.browder(ncmail net> Date: 11 /09/2 7 11:31 AM Subject: Re: Sheridan Subdivision Phase 1 Will need to get confirmation of final li.nc lengths and sizes Thanks DEE MikeGar°b< o.union.nc.us wrote: Only the flow changes on this. Total Flow should be 51,315 gpd 1 of 3 1 1 /9/2007 4:03 PM Re: Sheridan Subdivision Phase I Mike Carhark, PE Assistant Engineering Director Union County Public Works 500 N Main. Street Monroe, NC 2811.2 --Dee Browder <dee.browder(cc mail net-, rote: --- To: ilikeGarbark(co.unicn,nc.0 From: Dee Browder de _.browder'a ncrail.n Date: 10/29/2007 03:55 Subject: Sheridan Subdivi ion Phase 1 W 0029254 Need totals Thanks DIE ADdv l ADdv :. 2 of 3 1 1 /9/2007 4:03 PM